Tender For Repair/Replacement Of Internal Wiring Alongwith Replacement Of Various Light Fittings , Ceiling Lights And Other Connected Works At A Park And Old Park Area Of Cafvd Under Age E/M-Ii In Ge (Central) Khadki.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
7 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Internal Wiring Alongwith Replacement Of Various Light Fittings , Ceiling Lights And Other Connected Works At A Park And Old Park Area Of Cafvd Under Age E/M-Ii In Ge (Central) Khadki.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc . |
| 2 | Material and labour for point wiring in light/fan/exhaust fan point controlled by one switch in casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with suitable thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge. |
| 3 | Description all as per Srl item No 2 above but point wiring for bell/buzzer point controlled by one switch. |
| 4 | Description all as per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 5 | Description all as per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 6 | Description all as per Srl item No 2 above but for 2.5 sqmm point wiring for 5 pin switch socket outlet 15 Amps on independent board controlled by one switch. |
| 7 | Material and labour for point wiring in light/fan/exhaust fan point controlled by one switch in pvc conduit/concealed of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and as directed . |
| 8 | Description all as per Srl item No 7 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 9 | Description all as per Srl item No 7 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 10 | Description all as per Srl item No 7 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit/concelaed. |
| 11 | Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arragements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, incld material all as specified and as directed. |
| 12 | Description all as per Srl item No 11 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 13 | Description all as per Srl item No 7 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 14 | Material and labour for point wiring complete as specified with 1100 V grade 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FR grade, conforming to relevant IS drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover including 4 Sqmm single core PVC insulated and unsheathed copper conductor cable FR grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and as directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch. |
| 15 | Description all as per Srl item No 7 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in steel conduit. |
| 16 | Description all as per Srl item No 7 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit/concealed. |
| 17 | Supply and fix switch piano flush type single pole, one way 5 Amp. |
| 18 | Supplying & fixing switch flush type, 5 Amps, Bell push , flush type , 230 volts AC circuit complete all as specified and as directed. |
| 19 | Supply and fix single socket outlet 3 pin 6A ,one way flush type complete all as specified and as directed. |
| 20 | Supply and fix switch piano flush type single pole, one way 16 Amp complete all as specified and as directed. |
| 21 | Supply and fix single socket outlet 2 in 1, 3 pin 6 &16 A , one way flush type complete all as specified and as directed. |
| 22 | Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed . |
| 23 | Supply and fixing in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and as directed. |
| 24 | Supply and fix bell Ding Dong AC, 230 volts, single pole all as specified and as directed. |
| 25 | Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material complete all as specified and as directed. |
| 26 | Material and labour for sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm PVC conduit/concealed and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and as directed. |
| 27 | Description all as per Srl item No 26 above but for casing & capping |
| 28 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC conduit/concealed 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and as directed. |
| 29 | Description all as per Srl item No 28 above but for casing & capping |
| 30 | Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including including New PVC conduit/concealed 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed. |
| 31 | Description all as per Srl item No 30 above but for casing & capping |
| 32 | Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type,10.0 Sqmm, 1100 volts grade, drawn through and including including New PVC conduit/concealed 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type,10.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and as directed. |
| 33 | Description all as per Srl item No 32 above but for casing & capping |
| 34 | Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and as directed. |
| 35 | Material and labour for sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. |
| 36 | Material and labour for sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. |
| 37 | Material and Labour for sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. (Note for item No 35 to 37) :- (a) Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length. |
| 38 | Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge. |
| 39 | Supply and fix, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed .NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 40 | Supply and fix, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 41 | Supply and fix, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed . NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 42 | Supply and fix, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed . |
| 43 | Supply and fix, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed . |
| 44 | Supply and fix, connecting & testing SPN DBs of 4 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. |
| 45 | Supply and fix, Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and as directed. |
| 46 | Supply and fix, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and as directed . |
| 47 | Supply and fix, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and as directed. |
| 48 | Supplying & fixing MCB 40 to 63 Amps, TPN \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 49 | Supplying & fixing MCB 40 to 63 Amps, TP \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 50 | Supplying & fixing MCB 6 to 32 Amps, single pole and neutral, \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 51 | Supplying & fixing MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and as directed. |
| 52 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and as directed. |
| 53 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 32 Amps and supplied with neutral links complete all as specified and as directed. |
| 54 | Dismantling and Taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge. |
| 55 | Supply & fixing, LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 56 | Supply & fixing, CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 57 | Supply & fixing, 36W 2X2 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 58 | Supply & fixing, 36W 2X2 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 59 | Supply & fixing, 1X18W,4 Feet LED Ceiling suspended light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 60 | Supply & fixing, 40W,1x4 Feet LED recess light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 61 | Supply & fixing, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. Please Enable Macros to View BoQ information |
| 62 | Supply & fixing, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer