Tender For Provn Of Work Services For Renovation Of Kitchen In Nc(E)S Block And Mes Qtrs(Ph-Ii) & special Reapair To Toilets At Gt Ground At 4Afsb Under Ge(Af) Gorakhpur.
Tender Value
43.60 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
6 days left
EMD
87200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Work Services For Renovation Of Kitchen In Nc(E)S Block And Mes Qtrs(Ph-Ii) & special Reapair To Toilets At Gt Ground At 4Afsb Under Ge(Af) Gorakhpur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: PROVN OF WORK SERVICES FOR RENOVATION OF KITCHEN IN NC(E)s BLOCK AND MES QTRs(Ph-II) & SPL REAPAIR TO TOILETS AT GT GROUND AT 4AFSB UNDER GE(AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-62 OF 2026-27 File No. 9512/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Descripion of items Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engr-in-charge. |
| 3 | Supply and fixing factory made UPVC white colour three track panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of frame 110x 45mm & sash 40 x 62 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/double glazing bead of approproate dimension comprising of UPVC multi chambered frame. with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 + 0.2 mm thick galanized mild steelsectin made form roll forming process of required length ( shape & size according to UPVC profile) , appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy ( white powder coated) touch locks with hook , zinc alloy body with single nylon rollers (weight bearin capacity to be 40 kg) G.I fasteners 100x 8 mm size for fixing frame to finished wall and necessry stainless steel screws etc. Profile frame & sash sall be mitred cut and fusion weled at al corners, including drilling of holes for fixong hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality. complete all as specified and directed by Engineer- in Charge . Note -1. Glazed shutters float glass thickness not less than 5.00 mm and wiremes shutter with Stainless steel wire mesh 0.36 mm dia with aparture 1.4 mm shall also be deemed included in quoted rates and No extra payment will be made separately. 2. for UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 4 | S & F Mild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 5 | M & L for preparation painting new steel surfaces of any description over 10cm width or girth not other wise described with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed . |
| 6 | M&L for preparation of old decorated surface of ceiling and applying one coats of whites wash complete all as specified. |
| 7 | M&l for complete removal of existing treatment and applying two coats of oil bound distemper including roller mat finishing on wall surfaces complete all as specified and directed. |
| 8 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete and applying two or more coats acrylic smooth exterior paint of required shade on old existing cement base paint surface @ 1.67 ltr/10 sqm complete all as specified. |
| 9 | Dismantling of floor,wall tiles incl cement mortar bedding but not backing removing serviciable tiles to stores complete all as specified. |
| 10 | Material & labour for non skid ceramic coloured tiles 7mm to 8mm thick (Square/rectangular) area of each tile exc 0.11sqm but n.exc 0.18sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed by the Engr-in-Charge. |
| 11 | M&L for glazed ceremic coloured tiled in vertical surfaces 450x300x8/600x300x9 mm thick(as approved by Engr-in-Charge) set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and directed. |
| 12 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15 mm dia. complete all as specified and directed. |
| 13 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 20 mm dia complete all as specified and directed. |
| 14 | S & F 15 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 15 | S & F 20 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 16 | Dismantling of PVC water storage tank exc 250 and not exc 500 ltrs capacity and removing to store. |
| 17 | S&F 500 ltrs capacity Rotational moulded polythene water storage tanks in three layers (cylindrical vertical with close top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed. |
| 18 | S&F as in repairs 20/25mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwedfor iron pipe fixed complete all as specified and directed. |
| 19 | M&L in repairs, 75mm dia PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete as specified and directed. |
| 20 | Demolition of brick work built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings etc. |
| 21 | M&L brick work with sub class 'B' bricks,straight or curved on plan exc 6m mean radius built in cm 1:6. complete all as specified and directed. |
| 22 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 23 | S & F in repair stainless steel kitchen sink with drainage board of over all size 915 mm X 460 mm and bowl size 410 mm X 330 mm X 160 mm, 1 mm thick with plug washers and wastes ; including bedding in CM to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed. |
| 24 | Providing and fixing C.P. brass long nose bib cock 15mm bore of approved quality conforming to IS standards and weighing not less than 810 gms complete all as specified. |
| 25 | Providing and fixing magnetic catcher triple strip vertical type of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete all as specified and directed. |
| 26 | Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). |
| 27 | Providing and fixing 200mm stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 28 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 29 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. |
| 30 | Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) |
| 31 | S&F SS dust bin 14ltrs code -IHISG 2154,Make sleek and equivalent as approved by GE complete all as specified and directed. |
| 32 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position. |
| 33 | Use & waste of form work for fair finished flat surface to soffit of suspended slabs such as roof slabs, floor slabs, landing and similar work n.exc 200mm thick (horizontal or sloping) complete all as specified. |
| 34 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape, required, including cranking, bending sprially for hoping for cols, hooking ends and binding with MS and including wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 35 | M&L for reinforcement cement concrete (1:2:4) type B-1 (nominal mix) using 20mm graded crushed stone aggregate as in roof slab supported on walls, beams and columns, in floors, roofs, landings, balconies etc and in shelves and the like all as specified & directed. |
| 36 | Providing and laying flamed finish Granite stone slab jet black ,cherry red ,elite brown,cat eye or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 37 | Taking down cement plaster from brick or stone walls any description including raking out joints, hacking for key, scrubbing down with water to receive plaster removal of rubbish off the premises etc. |
| 38 | M&L for rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in CM (1:4) finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 39 | M&L for rendering 15m thick cement plaster on other than fair faces of brick work or concrete surfaces CM (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 40 | M&L for rendering 5mm thick cement plaster on ceiling surfaces on brick or concrete surfaces in CM (1:3) with 1mm thick wall care putty complete all as specified. |
| 41 | M&L for preparation of new plaster of wall and applying two coats of white wash on ceiling surfaces complete all as specified. |
| 42 | M&L for preparation of new plaster of wall and applying two coats of oil bound distemper over chalk whiting primer on plaster surfaces icluding 1mm thick wall care putty complete all as specified. |
| 43 | M&L Finishing walls with Acrylic Smooth exterior paint of required shade applying Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) on external wall surfaces including 1mm thick wall care putty complete all as specified. |
| 44 | Complete removal of existing treatment and applying two coats of oil bound distemper over 1mm thick wall care putty complete all as directed by Engineer-in-Charge. |
| 45 | M&L for preparation of old surfaces by complete removal of existing treatment and applying two coats of weather coats exterior emulsion paints over a coat of exterior grade water proof wall care putty 2 mm thick and a coat of primer complete all as specified and directed. |
| 46 | S&F casement window and ventilators with net and grill single or multi shutters turn window and made out of upvc multi-cavity frame sections of 60x60x2.5mm suitable reinforced and double multi shutters division are made by using shash mullion having 50x64x2.5mm multi cavity upvc section ,suitable and reinforced and GI and shutters are made out of 50x85x2.5mm upvc section,reinforced and welded in corner with EDPM gasket provision for glass and for air tightat frames and outer side of shutter with single glazed window and adjusting suitable glass bead with perfect hardware like hinges,handles,stays etc complete mosquito mesh shutters is made out of UPVC extuded section of 61x27x2mm with GI channel of 1.20mm thick welded in corner mosquito net of GI is fitted in shutters with proper required accessarry like,hinge MS grill of 12mm round pipe are insertedin main frame and inserted in main frame and screw by hidden screwing system with powder coating etc complete all as specified and directed.Note:Glazed shutters glass thickness not less than 3.00mm and wire mess shutters with SS wire mesh as approved by Engr-in-Charge is also included no payment will be seperately. |
| 47 | M&L screed bed or bedding layer of mortar (1:6) 15mm thick for laying floor finises of tiles complete all as specified and directed. |
| 48 | M&L for rendering 10mm thick in cm 1:4 on verticle surfaces of wall for fixing of wall tiles complete all as specified and directed. |
| 49 | Demolition of concrete of any description and in any position. |
| 50 | Materials and Labour for 75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in sub-base of floors, plinth protection finished the surface of concrete fair and even complete all as specified and directed. |
| 51 | Providing and fixing factory made extruded section profile size 42x50mm uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge. |
| 52 | Providing and fixing 30 mm thick factory made Polyvinyl Chloride (UPVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. |
| 53 | M & L for Roughning and cleaning to existing RCC roof surface/Roof treatiment and removing rubbish off the premises, cleaning surfaces of entire roof area, removing all dust ,loose particle and grease with a wire brush or scrubber and preparing to receive new roof treatment. Supply and Application of 5 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation. The surface is then to be tested for water tightness with a ponding test for min. 2 days and then top-coated with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only.The guarantee for treatment shall be given by the contracyor in writing for a period of 5 year and security deposit @ 2.5 % of total cost of treatment shall be given for 5 year from the date of completion of work. |
| 54 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.Make ;Jaquar or equivqlent |
| 55 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.Make ;Jaquar or equivqlent |
| 56 | Supply & fix in repair Vitreous China Table top Wash hand basin snow white/ white minimum size 495mmX395mmX150mm fixed in granite slab including chromium plated single lever mixure with 150 mm extension body swinging spout without popup waste (Table mounted), with braided hoses suitable for basin mixure, angular stop cock (valve) complete all as specified. Make:- (i) Wash Hand Basin cat part No- JDS-WHT-25909, Braided hose code ALD-CHR-801B, Chromium plated single lever Sink mixture Code-OPP-CHR-15005BPM and angular stop cock code No FUS-CHR-29053 of Jaquar or equivalent model of make specified in Appendix'B' of particular specification. (ii) Granite slab shall be measured and paid for separately under respective item of this schedule of work. Complete all as specified and directed.Make ;Jaquar or equivqlent |
| 57 | Supply & Fix in repair 5 to 6 mm thick selected quality mirror glass, mounted on 6mm thick commercial plywood and fixed to walls with wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 58 | Providing and fixing C.P. brass long nose 15mm bore bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 59 | Supply and fix in repairs Brass chromium plated tubular towel rail with hook, 20 mm dia, D type, 60 cm long between flanges, complete all as specified and directed. |
| 60 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 61 | Providing and fixing 15mm bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 complete all as specified and directed. |
| 62 | S&F in repairs Soap Dispenser with glass bottle fixed with necessary Cadmium plated screws. Make:- Jaquar code No-CAN-CHR-1135N or equivalent model of make specified in appendix 'B' to particular specification. |
| 63 | S&F in repair urinal wall partition toughned glass frosted 08 mm thick, with stainless steel fitting, rectangular shaped,chrome finish etc. Size 900X450mm complete all as directed by Engineer-in- Charge. Note:- All exposed edge of glass shall be bevelled/rounded. Make:- Jaquar Code No- JSE-CHR-810US450X |
| 64 | Supply & Fix in repair hand Dryer Flash touch-free infrared '. Note:- Code: HDR-SSF-AK2807 of Jaquar or equivalent model of make specified in Appendix'B' of particular specification. |
| 65 | Supply & Fix in repair corner glass shelf (with bracket) fixed with necessary Cadmium palted crews. Make:- Jaquar Cat part No ACN-CHR-1173 or equivalent model of make specified in appendix 'B' to particular specification. |
| 66 | Providing and fixing CP brass toilet paper holder complete all as specified |
| 67 | Dismantling/demolition of breaking up drain pipes of and 100mm dia PVC (SWR),salt glazed ware ,AC pipes set in cement morter or clamps in floor,wall etc complete all as specified. |
| 68 | ditto as avove but 75mm bore. |
| 69 | S&F 110mm bore PVC (SWR) rain water,soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified. |
| 70 | S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 71 | S&F 75mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified. |
| 72 | S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 73 | Taking down carefully copper / aluminium point wiring (light, fan, switch,socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose,sketch light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed. |
| 74 | Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed. |
| 75 | Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 76 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling and paneling on this PVC conduit/casing caping on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. |
| 77 | All as per above but one 5 Amps socket out let point controlled by one switch on same board with other switches. |
| 78 | All as per above but one 5 Amps socket out let point on independent board controlled by one switch. |
| 79 | All as per above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG. |
| 80 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 81 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 82 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 83 | S & F for Modular Switch Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 84 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 85 | Supply and fixing for batten/angular fittings complete all as specified and directed. |
| 86 | Supply and fix LED Lamp 7/8 watt complete all as specified and directed. |
| 87 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 88 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 89 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 90 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 91 | Supply and fixing in repair LED tube light batten box type with decorative end caps suitable single tube 1x 18/20 watt type complete internally pre wired and fixed to wall/ceiling incl fittings accessories connecting up with twin core twisted flexible copper conductor cable suitable size all as specified. |
| 92 | Taking down old unserviceable exhaust fan and deposited to MES Store complete all as specified and as directed. Note:- Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 93 | Supply and fix exhaust fan, Steel body AC single Phase. 230V of size 230 mm sweep with, blades, and frame and grouting with nut , bolts & Fastenar on the wall and making the hole in existing wall of specified size also make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper wire upto ceiling rose complete all as specified and directed .Make: Crompton/ Bajaj/Havells/Usha. |
| 94 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical/ horizontal type as required with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 95 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 96 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 97 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 98 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 99 | Supply and fixing LED bulk head 10 watt fittings environmental friendly ultra modern energy saving surface mounted decorataive bulk head fitting with electronic driver and prewired and necessary electric connection with PVC insulated twin twisted flexible copper wire of size 0.75 Sqmm complete all as specified and as directed. Make: Crompton/Bajaj/Havells. |
| 100 | Supply and fix exhaust fan, Engineering plastic body AC single Phase. 230V of size 230 mm sweep with, blades, and frame and grouting with nut , bolts & Fastenar on the wall/windows and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper wire upto ceiling rose complete all as specified and directed .Make: Crompton/ Bajaj/Havells/Usha. |
| 101 | Supply and fix electric water heater( Geyser) , storage type steel body with steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 102 | Supply and fixing of Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 Metres below ground level connected with earthing lead of 4mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion including excavation in any type of soil,returning filling, disposal of soil, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. |
| 103 | Supply , laying & testing for XLPE underground cable insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 4.0 core.Make: Havell's/Polycab/KEI/Gloster |
| 104 | M & L for Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. |
| 105 | M & L dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation of thickness of sand 18 cm all as specified and directed by Engr - in - Charge. Note :- Sand thickness shall be measured 18 cm only . |
| 106 | M&L for bricks cover of old size bricks sub class 'B' with width equal to the length of the brick laid dry & flet abutted with with each other with gap between adjacent bricks n.exc 10 mm over UG cable for protection complete all as specified and directed. |
| 107 | M & L for Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 108 | Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete all as specified and directed. |
| 109 | M & L for Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender