Tender For Repair And Maintenance Of External Water Supply Pipe Line Network, Including Connected Works At North C Us Under Ge Ima Dehradun.
Tender Overview
Project Description
Tender for Repair And Maintenance Of External Water Supply Pipe Line Network, Including Connected Works At North C Us Under Ge Ima Dehradun.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying, joint, testing and commissioning of DI pipes 100 mm bore Centrifugally cast, internal cement mortar lining, external zinc coating with finishing layer of bitumen, pressure pipe socket and spigot end, confirming to IS 8329-2000 with ISI marked K-7 in standard length including necessary rubber gasket, tyton jointings, jointing materials including taking down old unsv CI/DI pipe complete all as specified. |
| 2 | All as per item No. 1 here in above but 150 mm bore complete all as specified & directed. |
| 3 | All as per item No. 1 here in above but 200 mm bore complete all as specified & directed. |
| 4 | M&L for construction of brick masonry with full brick wall chamber size of 1500x1500x1500mm internal diemension with earth work on any type of soil , PCC M-10 type C-2 as in foundation , brick work in CM1:4, 15mm thick plaster in CM1:4 internaly and externally , flush pointed in same mortar as work proceeds , 75mm thick PCC coping all around (M-15 with 20mm aggregate ) , flooring shall 40mm thick PCC M-15 (Nominal Mix ) laid over 75mm thick hard core. Top cover shall be made out of 3mm thick MS sheet fixed in angle iron frame made out of angle iron size 40x40x6mm with two numbers of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed including demolition of old existing abandoned valve pits complete all as specified & directed. |
| 5 | All as per item No. 4 here in above but size 1200x1200x1200 mm complete all as specified & directed. |
| 6 | All as per item No. 4 here in above but size 1000x1000x1000 mm complete all as specified & directed. |
| 7 | All as per item No. 4 here in above but size 900x900x900 mm complete all as specified & directed. |
| 8 | All as per item No. 4 here in above but size 750x750x750 mm complete all as specified & directed. |
| 9 | M&L for preparation of outer surfaces of OHR of capacity 1 LG, height 17-25 mtr from ground including staging and connected items such as inlet, outlet, overflow pipes, sluice valves, NRV, Air valves, gate valves, MS other articles such as bracing/ brackets etc, ladders, grills, and all other connected items within the fencing of OHR and painting of OHR with two coats of exterior emulsion paint including staging and two coats of synthetic enamel paint to all the MS/CI/DI articles such as inlet/outlet, overflow pipes and connected valves brackets etc. Note:- Preperation includes rubbing, scrapping, filling of putty and repaire to minor cracks/ joints with cement plaster. Required T&P shall be contractor's own arrangement. Note: Contract shall take all necessary safety precautions for labours at site. |
| 10 | All as per item No 9 here in before but capacity 0.5 lakh Gallons complete all as specified & directed. |
| 11 | M&L for drain out water/dewatering the tank with portable submersible pump from Over Head Reservior (OHR) of capacity 1 lakh Gallons at 21 mtr height from ground and cleaning of wall, ceiling and floor by high pressure water jet and remove the sludge / mud thoroughly, clean inner surface of the tank and wash out by flushing with clean water and drain out complete all as directed by Engr-in-Charge. |
| 12 | All as per item No 11 here in before but capacity 0.5 lakh Gallons at 21 mtr height complete all as specified & directed. |
| 13 | M&L in repair joint with rubbers or rubber rings incl nut, bolts, washers, and mineral oil of size 100 mm bore flanged pipe complete all as specified. |
| 14 | All as per item No. 13 here in above but 150 mm bore complete all as specified & directed. |
| 15 | All as per item No. 13 here in above but 200 mm bore complete all as specified & directed. |
| 16 | M&L CI/DI/MS fittings as per IS for water pressure pipe, flanged one ends such as tail pieces, tapers, tee bend, bell mouth pieces etc up to 200 mm bore size complete all as specified & directed. |
| 17 | M&L for cast iron Machanical collar suitable for 80 mm bore CI /DI pipe with suitable push on type tyton joints nuts, bolts and washer complete including necessary earth work complete all as specified & directed. |
| 18 | All as per item No. 17 here in above but 100 mm bore complete all as specified & directed. |
| 19 | All as per item No. 17 here in above but 150 mm bore complete all as specified & directed. |
| 20 | All as per item No. 17 here in above but 200 mm bore complete all as specified & directed. |
| 21 | M&L in repair for Drilling and tapping cast iron water mains (in position) for branch connection of 20/25/40/50 mm dia including clamps , nut, bolts and rubber packing as required where directed by Engineer-in-Charge complete all as specified & directed. |
| 22 | M&L in repair for taking down/Relaying/ refixing of old steel tubing of size 15 mm bore and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc all as directed by the Engineer-in-Charge complete all as specified & directed. |
| 23 | All as per item No. 22 here in above but 20 mm bore complete all as specified & directed. |
| 24 | All as per item No. 22 here in above but 25 mm bore complete all as specified & directed. |
| 25 | All as per item No. 22 here in above but 40 mm bore complete all as specified & directed. |
| 26 | All as per item No. 22 here in above but 50 mm bore complete all as specified & directed. |
| 27 | All as per item No. 22 here in above but 80 mm bore complete all as specified & directed. |
| 28 | M&L for supply and lay in trenches GI tubing medium grade with necessary fittings such as bend, tee,elbow etc complete of size 15 mm bore including taking down old unserviceable GI tubing complete all as specified and directed by Engineer-in-Charge. Make- complete all as specified & directed. |
| 29 | All as per item No. 28 here in above but 20 mm bore complete all as specified & directed. |
| 30 | All as per item No. 28 here in above but 25 mm bore complete all as specified & directed. |
| 31 | All as per item No. 28 here in above but 40 mm bore complete all as specified & directed. |
| 32 | All as per item No. 28 here in above but 50 mm bore complete all as specified & directed. |
| 33 | All as per item No. 28 here in above but 80 mm bore complete all as specified & directed. |
| 34 | M&L steel tubing medium grade galvanized with all fitting of size 15 mm bore laying on walls and ceilings or laying in floors including cutting through walls and making good to surfaces after laying of pipe complete all as specified and directed. |
| 35 | All as per item No. 34 here in above but 20 mm bore complete all as specified & directed. |
| 36 | All as per item No. 34 here in above but 25 mm bore complete all as specified & directed. |
| 37 | Supply and fix in repair of gun metal gate valve with crutch or butterfly handle screwed both end for iron pipe of 15 mm bore including old unserviceable gate valve complete all as specified and directed by Engineer-in-Charge |
| 38 | All as per item No. 37 here in above but 20 mm bore |
| 39 | All as per item No. 37 here in above but 25 mm bore |
| 40 | All as per item No. 37 here in above but 40 mm bore |
| 41 | All as per item No. 37 here in above but 50 mm bore |
| 42 | S&F in repairs bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in 15 mm bore pipe complete all as specified & directed. |
| 43 | All as per item No. 42 here in above but 20 mm bore complete all as specified & directed. |
| 44 | S&F sluice valve cast iron body, double flanged and drilled, 80 mm bore as per IS- 14846, class PN-1.6, long body type with SS spindle etc with all fittings, jointing materials etc including taking down old unserviceable sluice valve complete all as specified and directed. |
| 45 | All as per item No. 44 here in above but 100 mm bore complete all as specified and directed. |
| 46 | All as per item No. 44 here in above but 150 mm bore complete all as specified and directed. |
| 47 | All as per item No. 44 here in above but 200 mm bore complete all as specified and directed. |
| 48 | S&F non return valve cast iron flanged both end installed on 150 mm dia CI pipes including taking down old unsv non return valve complete all as specified and approved by Engineer-in-Charge |
| 49 | S &F installed CI air release valve double ball fixed on 150 mm dia CI pipe including taking down old unsv air release valve as specified and approved by Engineer-in-Charge. |
| 50 | M&L for lead wool joints including jointing materials such as spun yarn etc in position including taking out damaged lead joins from the existing CI mains of size 80 mm bore complete all as specified and directed. |
| 51 | All as per item No. 50 here in above but 100 mm bore complete all as specified and directed. |
| 52 | All as per item No. 50 here in above but 150 mm bore complete all as specified and directed. |
| 53 | All as per item No. 50 here in above but 200 mm bore complete all as specified and directed. |
| 54 | M&L for repacking or stuffing box of sluice valve spindle of size 80 mm bore including taking apart and re-assembling in valve pit chamber/on open line complete all as specified and directed. |
| 55 | All as per item No. 54 here in above but 100 mm bore complete all as specified & directed. |
| 56 | All as per item No. 54 here in above but 150 mm bore complete all as specified & directed. |
| 57 | All as per item No. 54 here in above but 200 mm bore complete all as specified & directed. |
| 58 | M&L UPVC pipes of size 20mm dia SCH 80 having thermal stability for hot & cold water supply including all fittings such as coller, union, tee, elbow, end cap, etc laid in trenches complete all as specified and as directed |
| 59 | All as per item No. 58 here in above but size 25 mm bore Please Enable Macros to View BoQ information |
| 60 | All as per item No. 58 here in above but size 25 mm bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender