Tender For Repair And Maintenance Of Ats Panels And Changeover Panels For Dg Set At Map Accn, Old Mh And Other Locations Under Ge (U) Udh Ur.
Tender Overview
Project Description
Tender for Repair And Maintenance Of Ats Panels And Changeover Panels For Dg Set At Map Accn, Old Mh And Other Locations Under Ge (U) Udh Ur.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Oct-2026 | BOQ REVISED | BOQ | 06-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair and Maint of ATS Panels and changeover panels for DG set at MAP accn, Old MH and other locations under GE (U) Udhampur. Contract No: GE/U-109/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Supply and fix in replacement of electronic ATS with double break contact system suitable for aluminium termination providing protection against UV/OV, phase sequence and frequency deviation of rating 125 Amps (including all working accessories), 415V, 50/60Hz, l closing=3A/230V, l tripping=0.5A/230v, Complete all specified and directed by Engineer-in-Charge. |
| 3 | Supply and fix in replacement of electronic ATS with double break contact system suitable for aluminium termination providing protection against UV/OV, phase sequence and frequency deviation of rating 100 Amps (including all working accessories), 415V, 50/60Hz, l closing=3A/230V, l tripping=0.5A/230v.,Complete all specified and directed by Engineer-in-Charge. |
| 4 | Supply and fix in replacement of On Load Change-over switches including terminal shrouds, source separaters and phase barriers suitable for both vertical and horizontal mounting in a sheet steel enclosure of capacity 415V, 250 Amps, 4 pole.Complete all specified and directed by Engineer-in-Charge. |
| 5 | Supply and fix MCCB 4 Pole, Ics = 100% Icu, breaking capacity of 25 KA, 415 Volts, 125 Amps, with thermal adjustable and adjustable magnetic setting, having line load reversibility, with spreder terminal supplied by the OEM of MCCB as main panel incomer, Complete all specified and directed by Engineer-in-Charge. |
| 6 | Supply and fix MCCB 3 Pole, Ics = 100% Icu, breaking capacity of 25 KA, 415 Volts, 100 Amps, with thermal adjustable and adjustable magnetic setting, having line load reversibility, with spreder terminal supplied by the OEM of MCCB. Complete all specified and directed by Engineer-in-Charge. |
| 7 | Supply and fix MCCB 3 Pole, Ics = 100% Icu, breaking capacity of 25 KA, 415 Volts, 63 Amps, with thermal adjustable and adjustable magnetic setting, having line load reversibility, with spreder terminal supplied by the OEM of MCCB. Complete all specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix SMF lead-acid battery of 12V 180 AH for DG Set of Lifts/Elevators as specified and directed by Engg-in-charge. Make- Exide/Amaron/ Luminious |
| 9 | Supply and fix spreader and rear terminals for MCCB connections and aluminium bus-bars of rating 690V 125A 50 Hz ,Complete all specified and directed by Engineer-in-Charge. |
| 10 | Supply and fix connecting alley cables for termination of MCCBs and TPN Switches of medium grade each of 5 mtr length,Complete all specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix ELCB/RCCB for distribution panels of rating 40 Amps 415V 50Hz 4 Pole, providing 3-in-1 protection against overload, short circuit and earth leakage.Complete all specified and directed by Engineer-in-Charge. |
| 12 | Supply and fix TPN for distribution panels of rating 40 Amps 415V 50Hz 4 Pole, providing 3-in-1 protection against overload, short circuit and earth leakage, Complete all specified and directed by Engineer-in-Charge. |
| 13 | Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system of size 4 core X 25 Sqmm and laid in trenches/ducts/pipe or on poles Complete all specified and directed by Engineer-in-Charge. |
| 14 | Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system of size 4 core X 10 Sqmm and laid in trenches/ducts/pipe or on poles Complete all specified and directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of 3000VA, 230V, 50Hz, 14A UPS System alongwith connected accessories, connection cables, ports, plug and socket, overload module, controller drive, etc. complete all as specified by directed by Engr-in-charge. |
| 16 | Supply and fix in replacement of 1000VA, 230V, 50Hz, 6A UPS System alongwith connected accessories, connection cables, ports, plug and socket, overload module, controller drive, etc. complete all as specified by directed by Engr-in-charge. |
| 17 | Supply & Fix in replacement of electronic CTU card of lift, make as per sample complete all as specified and directed by Engr-in-charge. Make- Omega/TKE/KONE |
| 18 | Supply & Fix in replacement of Main Circuit Board (MCU) of lift for UPS Panel, make as per sample complete all as specified and directed by Engr-in-charge. Make- Omega/TKE/KONE |
| 19 | Supply & Fix in replacement of Push button of lift for cabin display, make as per sample complete all as specified and directed by Engineer-in-Charge.Make- Omega/TKE/KONE |
| 20 | Supply & Fix in replacement of Push button of lift for landing operating unit, make as per sample complete all as specified and directed by Engineer-in-Charge.Make- Omega/TKE/KONE |
| 21 | Supply & Fix in replacement of Cabin Display of lift for landing operating unit, make as per sample complete all as specified and directed by Engineer-in-Charge.Make- Omega/TKE/KONE |
| 22 | Supply & Fix in replacement of electronic CCU card of lift, make as per sample complete all as specified and directed by Engr-in-charge.Make- Omega/TKE/KONE |
| 23 | Supply and fix single phase preventer with phase sequence detection of rating 415V, 50Hz +/-20%, 3VA for protection against single phasing with phase unbalance trip of 40V +/- 6V, time delay of 3.5 sec and automatic resetting mode complete all specified and directed by Engr-in-charge.Make- Minilec/Rapid Controls |
| 24 | Supply & Fix in replacement of Landing circuit Unit (LCU) of lift, make as per sample complete all as specified and directed by Engr-in-charge |
| 25 | Supply & Fix in replacement of Landing circuit Unit (LCU) Display of lift, make as per sample complete all as specified and directed by Engr-in-charge. |
| 26 | Supply and fix in replacement of twin harness connector cable for landing circuit unit of lifts display, make as per sample complete all as specified and directed by Engr-in-charge. |
| 27 | Supply & Fix in replacement of interlock limit switch of lift, make as per sample complete all as specified and directed by Engr-in-charge. |
| 28 | Supply and fix in replacement of inverter VFD main drive for 13 Passenger lift, make as per sample complete all as specified and directed by Engr-in-charge.Make- Omega/TKE/KONE |
| 29 | Supply and fix in replacement of inverter VFD main drive for 08 Passenger lift, make as per sample complete all as specified and directed by Engr-in-charge. Make- Omega/TKE/KONE Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender