Heavy Industries and Public Enterprises Government Departments Closing in 25 days TDR #58095911

Tender For Internal Water Supply Arrangements By Providing 350Mm D.I Pumping Main From Stp, Tharuvaikulam To M/S.Zetsol In Industrial Park, Thoothukudi.

Issued by Government Departments · Tuticorin, Tamil Nadu
Tender Value
8.52 Crore
Estimated cost
Bid Submission
17 Nov 2026
25 days left
EMD
4.36 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Internal Water Supply Arrangements By Providing 350Mm D.I Pumping Main From Stp, Tharuvaikulam To M/S.Zetsol In Industrial Park, Thoothukudi.

BOQ

Name of Work:- Internal Water supply arrangements by providing 350mm D.I Pumping Main from STP, Tharuvaikulam to M/s.Zetsol in Industrial Park, Thoothukudi.
Sl. No. Item Description
1(PART A) - Providing 350mm dia D.I and 400mm dia OPVC pumping main.
2Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils and including refilling the trenches with excavated sand etc., complete complying with standard specification and as directed by SIPCOT Officers.
3STP to Zestol for 350mm D.I pipe
4STP to Zestol for 400mm O-PVC pipe
5Supply and delivery of following dia D.I K7 pipes and OPVC Pipes etc., complete complying with standard specification and as directed by SIPCOT Officers.
6STP to Zestol 400mm O-PVC pipe (PN 12.5 class 500)
7Lowering of following size of D.I. pipes and specials in the trenches and laying to proper grade and alignement etc., complete complying with standard specification and as directed by SIPCOT Officers.
8STP to Zestol for 350mm D.I pipe
9STP to Zestol for 400mm O-PVC pipe (PN 12.5 class 500)
10Jointing of following D.I pipes with rubber gaskets (tyton joint) including cost of lubricants, testing to the required pressure with water (including cost of jointing materials etc., complete complying with standard specification and as directed by SIPCOT Officers.
11STP to Zestol 350mm D.I pipe
12Supply delivery and fixing of following CI D/F sluice valve with cap/ wheel as per IS 14846/2000 PN 1.0 with ISI marking and with 5 years warranty etc., complete complying with standard specification and as directed by SIPCOT Officers.
13350 mm CI Sluice Valve
14400 mm CI Sluice Valve
15200 mm CI Sluice Valve
16Supply Delivery and Fixing of 100mm Kinetic Air Valves for Handling More Volumes Of Air In Pumping Main, Double Orifice Kinetic Air Valve Confirming To Is 14845 TamperProof Design (Pn-1) And With 5 Years Warranty etc., complete complying with standard specification and as directed by SIPCOT Officers.
17Supply delivery and fixing of following D.I. specials etc., complete complying with standard specification and as directed by SIPCOT Officers.
18a. 350mm dia tail piece flanged /sipgot for valve
19b. 350mm dia 90 degree D.I bend
20c. 350 dia 90 degree Duckfoot bend
21d. 350mm dia 45 degree bend
22e. 350x350x200 \\"T\\"
23f. 350x350x100 \\"T\\"
24g. 400x400x200 \\"T\\"
25h. 200mm 90 degree bend flanged for scour
26i. 350mm dia tail piece flanged /spigot for 350 mm to 300mm reducer
27j. 350mm dia tail piece flanged spigot for 400 mm to 350mm reducer
28Supply delivery and fixing of following O-PVC specials etc., complete complying with standard specification and as directed by SIPCOT Officers.
29400mm dia 45 degree bend
30400mm dia 90 degree elbow
31400mm dia tail piece flanged/spigot for valve
32400x400x100 \\"T\\"
33400mm tail piece flanged/spigot for valve 400mm to 315mm reducer
34Supply delivery and fixing Ductile iron class PN10 200mm tail piece 2mtr length flanged pipes as per IS 8329/2000 etc. complete complying with standard specification and as directed by the SIPCOT Officers..
35Supply delivery and fixing Ductile iron class PN10 200mm tail piece 1mtr length flanged pipes as per IS 8329/2000 etc. complete complying with standard specification and as directed by the SIPCOT Officers.
36Supply and fixing 300mm dia water meter with dirt box of Woltman model with removal Mechanism water meters, (no domestic use) conforming to ISO 4064 part I,II,III Class B and IS-2373 with life cycle test certificate from FCRI/NABL accridated lab. The watre meter shall have amgnetic drivers or mechanical drivers and shall be versatile for installatio in any position. The meters shall be hydrodynamically, hydrostatically balanced. The runer, runner chamber, pointers of the meter shall be as per ISO 4064 specification.Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climates etc complete complying with standard specification and as directed by the SIPCOT Officers.
37Construction of masonry valve pit size of 1.50 m X 1.50 m for sluice valves, for fixing the valves including earth work excavation refilling wherever necessary cement concrete 1:4:8 using 40mm HBG metal for levelling course brick work in CM 1:5 for side wall, plastering with CM 1:5, 12mm thick RCC 1:2:4 using 20mm HBG stone jelly for cover slabs providing cut stones in CM 1:3 including supply, fabricating and placing in position of RTS grill including centering shuttering change and fixing surface box, refilling the sides of the pits etc complete complying with standard specification and as directed by the SIPCOT Officers.
38Construction of masonry valve pit size of 1.20 m X 0.90 m for sluice valves, for fixing the valves including earth work excavation refilling wherever necessary cement concrete 1:4:8 using 40mm HBG metal for levelling course brick work in CM 1:5 for side wall, plastering with CM 1:5, 12mm thick RCC 1:2:4 using 20mm HBG stone jelly for cover slabs providing cut stones in CM 1:3 including supply, fabricating and placing in position of RTS grill including centering shuttering change and fixing surface box, refilling the sides of the pits etc complete complying with standard specification and as directed by the SIPCOT Officers.
39Conveyance charges for 350mm dia DI pipes (9339m) from Cuddalore SIPCOT Industrial Park to SIPCOT Industrial Park Thoothukudi
40(PART-B) Providing Pumpset Arrangements
41Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel,M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings including MS base plate, flexible tyre coupling and bolts etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM (4000 LPM x30m head) etc complete complying with standard specification and as directed by the SIPCOT Officers.
42Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confirming to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation with continuous S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP (above 20 HP). The motor offered should be of energy efficient motors including handling charges (55Kw, 75 HP) etc complete complying with standard specification and as directed by the SIPCOT Officers.
43Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V (+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button (38 to 75 Kw) etc complete complying with standard specification and as directed by the SIPCOT Officers..
44Supply and delivery of 150mm dia pressure gauge and Vaccum guage including all accessories as per specification (For Suction and Delivery to be mounted on wall on Teak Wood Board) suitable for above pumpset on delivery side to be erected 2 Nos before and 1No after the valves including required specials and ringstop levelcock etc complete complying with standard specification and as directed by the SIPCOT Officers.
45Supply, delivery of floor mounting cubical type vermin, weather and dust proof powder coated factory made M.V Panel board fabricated with frame enclosed with M.S.Sheet of 16 gauge with hinged front door and railway type lock and key arrangements suitable for 75 KW/100 H.P etc complete complying with standard specification and as directed by the SIPCOT Officers.
46Incoming
47400 Amps, 440V, 3 phase TPN switch L & T (FN type) with HRC fuses to receive supply from TNEB-1 No and Genset - 1 No and suitable Change over switch - 1 No.
48Suitable ammeter with phase selector switch - 1 set
49Suitable Voltmeter with Phase selector switch-1 set
50RYB indication lamps of LED ON/OFF type-1 Set
51Out going
52250 Amps T.P switch L & T (FN type) with HRC fuses for controlling the HSC Centrifugal Pumpsets with two lock one key mechanical interlocking arrangements - 2 Nos
5363 Amps T.P.N Switch with HRC fuses for Vacum Pumpset - 2 Nos.
54100 Amps T.P.N Switch L & T (FN type) with HRC Fuses for controlling the capacitor - 1 No
5563 Amps T.P Switch with HRC fuses for lighting and 400 Amps TPN Switch.
5663 Amps T.P.N Switch L & T (FN type) with HRC fuses for lighting.
57Additional out going 250 Amps 440 V 3 phase TPN Switch L & T (FN type) with HRC fuse - 1 No.
58The design of switch board should facilitate easy operation of all switches and cable connection instruments should be located above or below the busbar. The swichboard shall confirm to IE rules in all respects and should be complete with all internal wiring etc. complete complying with standard specification and as directed by the SIPCOT Officers.
59Supply and delivery of 1.1KV grade steel armoured aluminium conductor U.G. cable as per relevent E.B Pole to metering box and metering box to cubical panel board I.S.S etc. complete complying with standard specification and as directed by the SIPCOT Officers.
6031/2 core 185 sq.mm. PVC Armoured UG Cable
61Laying the 3.5 core 185 sq.mm above cables from EB to MV panel Board through LT metering as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers.
62Jointing the 3.5 core 185 Sq.mm cables including the cost of jointing materials as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers.
63Supply and delivery of L.T. cables 3 core 1.1 KV grade armoured aluminum conductor cross Linked Poly Ethylene Insulated PVC sheathed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI marking for connecting Mortor and M.C Panel through starter etc. complete complying with standard specification and as directed by the SIPCOT Officers.
643 core 150 sq.mm
65Laying the 3 core 150 sqmm cables for connecting CF motors and MV Panel Board through starter etc complete complying with standard specification and as directed by the SIPCOT Officers.
66Jointing the 3 core 150 sqmm cables including the cost of jointing materials as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers.
67AEE's DIVINE Automatic Power Factor Corrector Panel to maintain the power factor upto 0.85 Capacity : KVAR : 30 Stage : 5 suitable for 75 HP etc. complete complying with standard specification and as directed by the SIPCOT Officers.
68Supply and delivery of 1.1KV grade 3.5 core 50 sq.mm steel armoured aluminium conductor cable as per relevent I.S.S [Panel Board to Power Factor corrected Panel] etc. complete complying with standard specification and as directed by the SIPCOT Officers.
693 1/2 core 50 sq.mm. PVC Armoured UG Cable
70Laying the 3.5 core 50 sq.mm cables from EB to MV panel Board through LT metering as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers.
71Jointing the 3.5 core 50 Sq.mm cables including the cost of jointing materials as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers.
72Supply and delivery of 1.1KV grade 3 core 50 sq.mm LT cables armoured aluminium conductor cable cross Linked Poly Ethylene Insulated PVC sheathed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI marking as per relevent I.S.S [Panel Board to Vacum Pump] etc. complete complying with standard specification and as directed by the SIPCOT Officers
733 core 50 sq.mm. PVC Armoured UG Cable
74Laying the 3 core 50 sq.mm cables from panel board to capacitor / Vacum Pump as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers
75Jointing the 3 core 50 sq.mm cables including the cost of jointing materials as per IE rules etc. complete complying with standard specification and as directed by the SIPCOT Officers
76Supply and delivery of 350mm dia DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate valves(Sluice Valves) with body Bonnet of Ductile cast iron of rade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years warrenty etc complete complying with standard specification and as directed by the SIPCOT Officers
77Supply & delivery of 350mm C.I. D/F Reflux Valve as per I.S. 5312/2004/ part I/ 84 PN 1.0 with bye-pass arrangements with ISI marking and with 5 years warranty etc complete complying with standard specification and as directed by the SIPCOT Officers.
78Providing twin CI Earthing the pumproom and MV panel board starter & other installations as per IE rules including construction of earth pit and RCC cover slab for the earth pit providing RCC cover slab above 60 HP-150 HP as per IS 3043/1987 Latest amendments and etc complete complying with standard specification and as directed by the SIPCOT Officers
79Supply and delivery of the following standard tools etc complete complying with standard specification and as directed by the SIPCOT Officers
806” Chain wrench best India make or equivalent
818”Chain Wrench Best India Make or equivalent
82Connector Screw Driver 901 Taparia Make orequivalent
83200mm Screw Driver 825 Taparia Make or equivalent
84300mm Screw Driver 829 Taparia Make or equivalent
85400mm Screw Driver 930 Taparia Make or equivalent
86200mm Cutting Plier Taparia Make or equivalent
87800mm Ball Pane Hammer with Handle Taparia Make
88Digital Tong Tester CE Make or equivalent
89Digital Multi Meter CE Make or equivalent
9015” Screw Spanner Taparia Make or equivalent
9112” Bearing Puller
92Lever Type Grease Gun
9312”Screw Spanner
94Crow Bar 5”
951” Cold Chisel
96Hacksaw Frame with Blade
97Electrical Air Blower
98Digital Tachometer
99Hand Crimpling Tool 8”
100DE Spanner set 6 to 32 Jhalani Make or equivalent
101Rings spanner set 6 to 32 Jhalani Make or equivalent
102Pipe Wrench 24” Jhalani Make or equivalent
103Pipe Wrench 14” Jhalani Make or equivalent
10412” Flat rough File Scissors Jhalani Make or equivalent
10512” Flat smooth File Scissors Jhalani Make orequivalent
10612”Round File Rough Scissors Jhalani Make orequivalent
10712” Round File Smooth Scissors Jhalani Make orequivalent
10812”Half Round File Rough Scissors Jhalani Make orequivalent
10912”Half Round File Smooth Scissors Jhalani Make orequivalent
110Supply and delivery of LT metering board to install 75HP-150HP/56-112KW (which includes LTCT meter panel board, 6Nos. Suitable fuse carriers and 3 nos. CT coil) etc complete complying with standard specification and as directed by the SIPCOT Officers
111Supply and delivery of safety appliances as detailed below for main pump house and control room 100 HP/ 75 KW etc complete complying with standard specification and as directed by the SIPCOT Officers
112Electrical gloves tested to 11KV/2KV with wooden box dusted with french chalk powder
113Electrical quality 6mm thick rubber mat
1145 KG capacity ISI marked dry chemical powder fire extinguisher
115Fire bucket three numbers hooked to MS Stand
116Laminated shock treatment chart
117Woodern first Aid box
118Rechargable emergency lamp (600mm Flaurescant lamp)
119Supply , delivery and erection of 5HP Model/ Rotary type vaccum pump set with (Pumpset + GI Pipes + fittings + Starters + Valves +100L Tank) including Transportation, handling charges etc complete complying with standard specification and as directed by the SIPCOT Officers
120Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities ( above 70 HP to 80 HP) etc complete complying with standard specification and as directed by the SIPCOT Officers
121Pipe Connection for Inlet and Outlet assembly to the Pumpset etc complete complying with standard specification and as directed by the SIPCOT Officers.
122Suction
123350 mm X 1.0 M C.I. D/F PIPE(NON-STD) - 10 Nos
124350 mm X 2 M C.I. D/F PIPE(NON-STD) - 2 No
125350 mm C.I.D/F 90 DEG BEND - 2 Nos
126350 mm X 200 mm C.I.D/F TAPER - 2 Nos
127Delivery
128350 mm X 200 mm C.I.D/F TAPER - 2 Nos
129350 mm C.I.D/F 90 DEG BEND - 1 Nos
130350 mm X 350 mm X 350 mm C.I.A/F TEE - 1 Nos
131350 mm X 1.0 M C.I. D/F PIPE(NON-STD) - 2 Nos
132350 mm CI D/F pipe 2.0 m to the Pumping Main size 1 No
133350 mm X 2.75 M C.I. D/F PIPE(STD) -1 Nos
134350 mm X 1.0 M C.I. D/F PIPE(STD) -1 Nos
135350 mm C.I.DUCK FOOT BEND - 1 No
136350 mm Flg /Socket Tail Piece 1 No
137400 mm X 350 mm C.I.D/F TAPER - 2 Nos
138Jointing of the above pipes and specials with the Bolt& Nuts and RI Sheet jointing materials etc complete.Jointing of the above pipes and specials with the Bolt& Nuts and RI Sheet jointing materials etc complete.
139350 mm C.I /D.I pipe
140(PART C) - Providing Pump room arrangements
141Earthwork excavation and deposting on bank with an initial lead of 10 m and lift of 2 m in head stiff clay blcak cotton, hard red earth, shales, murram, ordinary gravel, stoney earth and earth mixed with small size boulders for fountadion SS 20B etc., complete complying with standred specification and as directed by SIPCOT Officers.
142Levelling course with P.C.C 1:4:8 (one cement, four M sand and eight course aggregate) using 40 mm H.B.G stone including mixing concrete etc., complete and as directed by the SIPCOT Board officers.
143Brick work in CM 1:5 (one cement and five M sand) using Fly Ash bricks of size 230 x 110 x 70mm including cost of all materiala, labour charges, curing etc., complete and as directed by SIPCOT officers.
144Ground Floor
145First Floor
146Reinforced cement concrete 1:1/2:3 ) using 20mm size hard blue granite stone (machine crushed) for foundation, column, beam and roof slab excluding cost of reinforcement, fabrication and placing the grills in position and centering etc., complete and as directed by SIPCOT officers.
147Foundation and basement
148Ground floor
149First Floor
150Centering for sides and soffits of R.C.C slab of plane surface for R.C.C floor slab including strutting upto 3.3mt height using MS sheets of size 90cm x 60cm and stiffend with welded MS angle for size 25m x25mmx3mm laid over silver oak (country wood) joist etc., complete complying with the standard specificaiton. and as directed by SIPCOT officers.
151Below Plinth (Plane surface)
152Below Plinth ( FOR SQUARE COLUMN)
153Above Plinth ( FOR Plane surface)
154Above Plinth ( FOR SQUARE COLUMN)
155Plastering with CM 1:5 (one cement and five M sand) 12mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by SIPCOT Officers
156Supplying, fabricating and placing in position of Fe 500 Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc., complete complying with standard specification and as directed by SIPCOT officers. (Contractor has to make his own arrangements for the supply of steel and binding wire)
157Floor finishing with Granolithic finishing 40mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by SIPCOT Officers.
158Special ceiling plastering with CM 1:3 (one cement and three sand) 10mm thick including labour charges for fixing, finishing, curing etc., complete and as directed by SIPCOT Officers
159Supply and painting with two coats with cement paint approved quality over one coat primer over plastering surface including the cost of materials, labour charges, cleaning and preparation of the surface and curingetc., complete and as directed by SIPCOT Officers.
160Supplying and fixing of steel Windows two leaves including all cost, with fitting etc complete as directed by SIPCOT Officers (the design should be got approved by the SIPCOT Officers before supply & fixing) 1.20x1.90m
161Supply and fixing of steel door two leaves including all cost with fittings etc., complete complying with standard specification and as directed by SIPCOT officers [1.20m x 2.10]
162Weathering course with broken brick jelly 20mm size in pure slaked lime the proportion of brick jelly to lime being 32:12 1/2 % by volume of well beaten with wooden beaters so as to get on average thickness of 8 cm and to get the required slope of 6 to 30mm etc., complete complying with standard specification and as directed by SIPCOT officers
163Finishing the top of roof with one course of machine pressed tiles of 23 x 23 x 2 cm thick with C.M 1:3 mixed with crude oil 10% by weight of cement used and top pointed with same oiled mortor etc., complete and as directed by SIPCOT Officers
164Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete and as directed by SIPCOT Officers.
165Wiring with 2 x 1.5 sq.mm. (22/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) etc. complete and as directed by SIPCOT Officers.
166Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point etc. complete and as directed by SIPCOT Officers.
167Supply and Fixing of 20W 4 Feet LED Fitting with LED (Higher end) etc complete and as directed by SIPCOT Officers.
168Supply and Fixing of 60W LED Street Light Fitting with LED (lower end) etc complete and as directed by SIPCOT Officers.
169Supply and Fixing of AC Ceiling Fan complete 1200 mm (48\\") Sweep with 300mm down rod etc complete and as directed by SIPCOT Officers.
170Sub Total of Total Amount in Column BA (ie. Qty x Unit Rate)
171Added GST of 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58095911
AUTHORITY Government Departments
TENDER VALUE 8.52 Crore
LAST DATE 17-11-2026
Authority
Authority Name State Industries Promotion Corporation Of Tamilnadu Limited
Work Description Tender for Internal Water Supply Arrangements By Providing 350Mm D.I Pumping Main From Stp, Tharuvaikulam To M/S.Zetsol In Industrial Park, Thoothukudi.
Basic Detail
Tender No NIT.No.37/CD/T.No.37/2026-27
Bidding Type Tender
Location
City Tuticorin
State Tamil Nadu
Key Dates
Publish Date 16 Oct 2026
Submission Date 17 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 8.52 Crore
Tender Fee Ref. Documents
EMD 4.36 Lakhs
Exemption Not Available
Document List
788ac20d-4fb1-48f0-a7fb-d7db3c22fdee.html
AnnexureI.pdf
AnnexureII.pdf
BOQ_859446.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

788ac20d-4fb1-48f0-a7fb-d7db3c22fdee.html

pdf

AnnexureI.pdf

pdf

AnnexureII.pdf

xls

BOQ_859446.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender