Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58095821

Tender For Working Estimate For Providing Medical Gas Arrangements And Filling Low Lying Area In Government Hospital At Kanniyakumari In Kanniyakumari District.

Issued by Government Departments · Kanniyakumari, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Nov 2026
13 days left
EMD
7500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanniyakumari → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Working Estimate For Providing Medical Gas Arrangements And Filling Low Lying Area In Government Hospital At Kanniyakumari In Kanniyakumari District.

BOQ

Name of Work:- Working Estimate for Providing Medical Gas arrangements and filling low lying area in Government Hospital at Kanniyakumari in Kanniyakumari District.
Sl. No. Item Description
1Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
215mm OD 0.90mm Thick Copper Pipe
310mm OD 0.90mm thick copper pipe
422mm OD 0.90mm Thick Copper Pipe
528mm OD 0.90mm Thick Copper Pipe
6DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter-changeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers
7Oxygen manifold arrangements of 2 2 banks 2 cylinder each wing with semi-automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system.1) Manifold top frame with provision for connecting 4 cylinders on right bank and 4 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non-return valve, fasteners and cylinder support middle angle frame for claping 4 x 4 cylinders and related fasteners. The O2 manifold should withstand a pressure of 140 kg. / CM2) The installation is commissioned testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
8Oxygen manifold arrangements of 1 banks x 1 cylinder each wing with semi-automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system.1) Manifold top frame with provision for connecting 1 cylinders on right bank and 1 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder support middle angle frame for claping 1 x 1 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg/ CM2) The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827/ 1989 & ISO 7396 / 1987 Specification.
9Supplying and Fixing 4'' dial gauge adapter etc., complete, as per standard specification and as directed by the Departmental Officers .
10Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. 15mm Isolation Valve
11Supplying, fabricating and fixing Oxygen Boyles Kit for Operation Theatre with following specification: The Boyles Kit Hose is made of silicon and of white colour as per standard suitable adoptor fixed on higher end of hose to connect outlet unit and Boyles Machine. The adopter must be made of SS of superior quality. The rate includes cost of all materials and labour charges for fixing in proper position etc. complete and complying with standard specification.
12Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
13Supplying and fixing 3HP FRANK make compressed AIR cooled AIR compressor model and dry air etc., complete, as per standard specification and as directed by the Departmental Officers .
14GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58095821
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Working Estimate For Providing Medical Gas Arrangements And Filling Low Lying Area In Government Hospital At Kanniyakumari In Kanniyakumari District.
Basic Detail
Tender No e-Tender Notice No 12 / C.8-1 / 383M / 2026-27 Dt 15.10.2026
Bidding Type Tender
Location
City Kanniyakumari
State Tamil Nadu
Key Dates
Publish Date 16 Oct 2026
Submission Date 02 Nov 2026
Open Date 02 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7500
Exemption Not Available
Document List
7496335f-531a-4f2a-bc7f-12612081ff45.html
BOQ_859397.xls
TD_MedicalGas_GH_750.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

7496335f-531a-4f2a-bc7f-12612081ff45.html

xls

BOQ_859397.xls

pdf

TD_MedicalGas_GH_750.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender