Tender For Providing Fire Fighting Arrangements, Smoke Detection And Fire Alarm System At Newly Constructing College Of Arulmigu Palaniandavar Arts And Science College For Women, Oddanchatram C Us, Dindigul District
Tender Value
44.60 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
14 days left
EMD
32500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dindigul → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Fire Fighting Arrangements, Smoke Detection And Fire Alarm System At Newly Constructing College Of Arulmigu Palaniandavar Arts And Science College For Women, Oddanchatram C Us, Dindigul District
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Erection, Testing and Commissioning of FireFighting Application Monoblock Motor Pumpset of 450 LPM at 20 metres head to develop 2.0 kg/sq.cm at the highest and farthest hydrant point to make 10m water jet at the time of fire fighting emergency circumstances, coupled with 3.75 KW / 5 HP rated three phase 415 volts, 50 Hz, 2880 rpm electrical motor, the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia, including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the Departmental Officers |
| 2 | Supplying, Erection, Testing and Commissioning of Fire Fighting Electrical Control Panel of 10HP, 415V, 50Hz rating Wall Mounted Type fabricated using CRCA sheet, hinged lockable door, dust and vermin proof with following provisions.a. 50 Amps, 4 Pole MCB-Incomer, 6 Amps, 2 Pole MCB for Control Circuit-1 setb. R, Y, B Phase Indication Lamp, Voltmeter (0-500V),Ammeter (0-50A), Voltmeter Selector Switch-1setc. 32 Amps Power Contactor with 230V Coil, 14-23 Amps Over Load Relay-1 setd. Single Phase Preventer-1 No.e. Indication Lamp for Motor On/Off Push Button-1 setf. Auto / Manual Selector Switch, On / Off Push Button-1 setg. Add On Block, Terminal Block, Power Wiring, Control Wiring, Connectors, Cable Lugs, Slotted Cable Cover. The above panel mounted on wall using anchor fastners, bolts, plugs, incoming and outgoing cable connection and all works carried out as per standard specifications and as directed by the Departmental Officers. |
| 3 | Supply and laying of following sizes of Armoured Aluminium / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. a) 2 core 1.5 sq.mm armoured multi strand aluminium cable |
| 4 | Supply, Erection, Testing and Commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg./sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. a) 100 mm |
| 5 | B) 80 mm |
| 6 | C) 25 mm |
| 7 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. |
| 8 | Supply, Erection, Testing and Commissioning of cast iron body and gun metal or stainless steel Internal Non-Return Valve of size of 80mm dia to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers |
| 9 | Supply and Fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63 mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table E,bolts & nuts with washer as per IS 5290 at ringmain around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. |
| 10 | Supply, Installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20 mm dia braided thermo plastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20 mm dia ball valve and open and close spray nozzle,warmclip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers |
| 11 | Supply, Erection, Testing and Commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 12 | Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. |
| 13 | Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specificationand as directed by the Departmental Officers. |
| 14 | Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 15 | Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 16 | Priming Tank mounted with the supporting arrangement fabricated using MS angle for the height of 3 metres from the floor level, inlet, outlet, and drain arrangements inside the fire fighting pump room, as directed by the Departmental Officers |
| 17 | Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 18 | Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. |
| 19 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc.,complete as per standard specification and as directed by the Departmental Officers. a) 100 mm Dia |
| 20 | Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers. |
| 21 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. |
| 22 | Supply and Fixing of Addressable Fire Alarm Control Panel consists of display board which will have 160 Character Display with Touch key pad, Mother board 32 Bit Processor, In-built RS-485 Networking Circuit for peer to peer networking, In-built USB 2.0 Port, Loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring Approval: UL Listed a) 4 Loop Panel |
| 23 | Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications |
| 24 | Supply, Installation, Testing and Commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 25 | Supply, Installation, Testing and Commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers |
| 26 | Supply and fixing of Multi Sensor - Heat cum Smoke Detector |
| 27 | Power supply : 24 V DC Power Supply with 5 Amp rating, having LED indications for Power Supply ON, Battery Fail, Battery Charging, Battery Back Up etc., |
| 28 | Supply and fixing of loop card which will have 254 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both class A and Class B wiring. Shall have an LED indication for FIRE, Normal and Redundancy conditions Approval: UL Listed, (Make: Ravel/Equivalent) |
| 29 | Supply and fixing of 4\\" Dia Junction Box Made up of Metal/ABS Material |
| 30 | Providing & Fixing of Strainer 100 mm |
| 31 | Packing & Forwarding Charges |
| 32 | Transportation Charges |
| 33 | Unloading Charges |
| 34 | Sub Total |
| 35 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender