Tender for Supplying, Fixing, Testing And Commissioning Of 30 Kva Diesel Generator And Allied Works For Department Of Mathematics, University Of Kashmir (Advertised Cost Rs. 13.30 Lac) , Supplying, Installation, Testing And Commissioning Of Silent Diesel Generator Set 30 Kva, 1 Phase, 50 Hz Silent Dg Set With, Comprising Of Diesel Engine & Alternator As Per Standards, 1 Phase, 230, 50 Hz Both Mounted And Aligned On A Common Ms Base Frame Complete With Inbuilt Standard Panel, Mccb, Fuel Tank, Residential Exhaust Silencer, Battery Set As Required, Avm Pads, Battery Lead What So Ever Required Fitted In Sound Proof Acoustic Enclosure Approved By Cpcb Iv + Normes, Including 1St Fill Lube Oil, In All Respects As Required.Cold Starting Kit Is Mandatory Keeing In View Temperature Conditions In Srinagar. Including Two Years Comprehensive annual maintenance contract Note: The Company Should Have An Established Service Center In The Valley From Last 5 Years With Satisfactory Performance. , Supplying And Laying Of Isi Marked Aluminium Conductor Xlpe Insulated Cable As Per Is 7098, Un Armoured, Served, Sheathed 1100 Volts Grade. 70 Sqmm 2 Core I/C Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required , Supplying And Making End Termination With Brass Compression Glands Of Following Sizes Of 1.1. Kv Grade Multicore Aluminium Conductor Pvc Insulated And Pvc Sheathed 3½ X 70 Sq. Mm , Supply Of Advance Maintenance Free Chemical Gel Earthing Of Dual Pipe Technology (Gi) Of 3 Mtrs Long 80 Mm Dia Of Outer Shell (Ms) With The 50 Mm Dia Of Inner Shell (Ms) Of 80-100 Microns Galvanized Chemrode Filled With Highly Conducting Metallic Compounds With The Permenant Sealings At Both The Ends With The Lead Terminal Of 50X10mm Size At The Top. The Electrode Shall Be Duly Tested And Certified By Cpri (Central Power Research Institute), Govt Of India For A Peak Short Circuit Withstanding Capacity Of 60 Ka. Including Supply/ Fixing Of Environment Friendly Rust Proof Heavy Duty Weather Proof Polyplastic Earth Pit Chamber , Supplying And Laying 25 Mm X 5 Mm G.I. Strip At 0.50M. Below Ground Level As Strip Earth Electrode, Including Soldering Etc. As Required. , Providing And Constructing Reinforced Cement Concrete Foundation For 30 Kva Dg Set Of Approximate Size 6-0 × 10-0 And As Per Approved Drawings By Engineer-In-Charge, Including Excavation In Ordinary Soil To Required Depth Of Approximately 2-0, Dressing And Levelling Of Foundation Bed, Disposal Of Surplus Excavated Earth, Providing And Laying 150 Mm Thick Stone Soling In Foundation Bed And Intermediate/Mid Portion, 75 Mm Thick Plain Cement Concrete In Foundation Trench And Below The Grade Slab, 230 Mm Thick Reinforced Cement Concrete Raft And 150 Mm Thick Reinforced Cement Concrete Slab In 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Including Mixing, Laying, Vibrating, Compacting And Curing; Providing And Constructing 300 Mm Wide Foundation Block In 1:2:4 Concrete Mix, Extending Approximately 0-6 Below Ground Level And 2-0 Above Ground Level Or As Required At Site; Including Reinforcement Steel Of Approved Grade As Per Structural Design, Taken At Approximately 105Kg/Cum Of Rcc, Including Cutting, Straightening, Bending, Placing And Binding, Necessary Cover Blocks And Spacers; Necessary Centering And Shuttering; Anchor Bolts, Pockets, Sleeves, Recesses And Grouting Arrangements Required For Installation Of Dg Set; Anti-Vibration/Foundation Arrangements As Recommended By Dg Manufacturer; 6-12 Mm Thick Cement Plaster In 1:3 Cement Mortar On All Exposed Exterior Surfaces; Including All Materials, Labour, Tools, Plant, Machinery, Transportation, Loading/Unloading, Curing And All Incidental Works, I/C Suitable Fencing Around Foundation With Paint And Suitable Door I/C Locking Arrangement Complete In All Respects As Per Approved Drawings, Manufacturers Recommendations And Directions Of Engineer-In-Charge. , Change Over Panel. Supply, Installation, Testing And Commissioning Of Lt. Change Over Panel Totally Enclosed ,Indoor Type, Free Standing Type (1 Meter Stand Height), Dust, Damp And Vermin Proof Main Distribution Board Complete With Busbars, Lt. Danger Notice Plate,Multifunction Meter Indicating Lamps, Cts, Interconnections, With Suitable Capacity Aluminium Leads / Solid Aluminium Strips / Rods, Connection Of Incoming And Outgoing Cables With Thimbles, Stove Enamelled Painted And Having Following Incoming And Outgoing Mccb & Mcbs Complete As Required. 1No.160 annual periodical maintenance Tpn Mccb Release Of 36Ka Adjutable. 1 No.250 annual periodical maintenance Tpn Busbar 1 No. 160A, 3Phase Change-Over Front Panel Mount On Load Type1 Set Volt Meters And 3 Phqse Selector Switches 1 Set Led Phase Indicating Lamp With Mcb Protection.Suitable Ratting Busbars For Each Segment , Connecting /Setrighting Of Internal Cabling, Wiring And Terminations Of Existing Setup, With Dg Setup Per Site Requirements, Removal/ Dismantallling Of Old Wiring, Armoured Cables, Changing Of Circuits From Mains From Genset And Vice-Versa In Various Classrooms, Faculty Rooms, Shifting Of Lighting Points On Genset/Invertor/Ups Whereever Required As Per Site Requirement In Order To Make The System Functional In All Respects , Supply, Laying, Fixing Of Isi Marked Aluminium Conductor Xlpe Insulated Cable As Per Is 7098, Armoured, Served, Sheathed 1100 Volts Grade. 50 Sqmm 3 1/2 Core , Wiring For Circuit (Raw Power)/ Submain Wiring Along With Earth Wire With The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed In Class Heavy Duty Pvc Conduit As Required Note :Rates Of Suitable Pvc Conduit Included In Above Description For The Follwing Items , 2 X 10 Sq.Mm + 1 X 10 Sq.Mm Earth Wire For Sub Main Wiring , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing and Commissioning of Silent Diesel Generator Set 30 kVA, 1 Phase, 50 Hz Silent DG Set with, comprising of Diesel Engine & Alternator as per standards, 1 Phase, 230, 50 Hz both mounted and aligned on a common MS base frame complete with inbuilt Standard panel, MCCB, fuel tank, Residential Exhaust Silencer, battery set as required, AVM Pads, Battery lead what so ever required fitted in Sound Proof acoustic enclosure approved by CPCB IV + normes, including 1st fill lube oil, in all respects as required.Cold Starting kit is mandatory keeing in view temperature conditions in Srinagar. including two years Comprehensive AMC Note: The company should have an established service center in the valley from last 5 years with satisfactory performance. |
| 2 | Supplying and laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 70 sqmm 2 core i/c direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 3 | Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 70 sq. mm |
| 4 | Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber |
| 5 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required. |
| 6 | Providing and constructing RCC foundation for 30 KVA DG Set of approximate size 6'-0\\" × 10'-0\\" and as per approved drawings by Engineer-in-Charge, including excavation in ordinary soil to required depth of approximately 2'-0\\", dressing and levelling of foundation bed, disposal of surplus excavated earth, providing and laying 150 mm thick stone soling in foundation bed and intermediate/mid portion, 75 mm thick PCC in foundation trench and below the grade slab, 230 mm thick RCC raft and 150 mm thick RCC slab in 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including mixing, laying, vibrating, compacting and curing; providing and constructing 300 mm wide foundation block in 1:2:4 concrete mix, extending approximately 0'-6\\" below ground level and 2'-0\\" above ground level or as required at site; including reinforcement steel of approved grade as per structural design, taken at approximately 105kg/cum of RCC, including cutting, straightening, bending, placing and binding, necessary cover blocks and spacers; necessary centering and shuttering; anchor bolts, pockets, sleeves, recesses and grouting arrangements required for installation of DG set; anti-vibration/foundation arrangements as recommended by DG manufacturer; 6-12 mm thick cement plaster in 1:3 cement mortar on all exposed exterior surfaces; including all materials, labour, tools, plant, machinery, transportation, loading/unloading, curing and all incidental works, i/c suitable fencing around foundation with paint and suitable door i/c locking arrangement complete in all respects as per approved drawings, manufacturer's recommendations and directions of Engineer-in-Charge. |
| 7 | Change Over Panel.Supply, installation, testing and commissioning of LT. Change OVER Panel totally enclosed ,indoor type, free standing type (1 meter stand height), dust, damp and vermin proof Main Distribution Board complete with busbars, LT. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required.1No.160 Amp TPN MCCB release of 36kA adjutable.1 No.250 Amp TPN Busbar1 No. 160A, 3phase Change-Over front panel Mount on load type1 set Volt meters and 3 phqse selector switches 1 set LED phase indicating lamp with MCB protection.suitable ratting BUSBARS for each segment |
| 8 | Connecting /setrighting of internal Cabling, wiring and terminations of Existing setup, with DG setup per site requirements, removal/ dismantallling of old wiring, armoured cables, changing of circuits from mains from genset and vice-versa in various classrooms, faculty rooms, shifting of lighting points on genset/invertor/ups whereever required as per site requirement in order to make the system functional in all respects |
| 9 | Supply, laying, fixing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 50 sqmm 3 1/2 core |
| 10 | Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note :Rates of Suitable PVC conduit included in above description for the follwing items |
| 11 | 2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring |
| 12 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Please Enable Macros to View BoQ information |
| 13 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender