Tender For Overhauling And De-Scaling Of Central Heating System And Other Allied Works At High Court Of Jammu & Kashmir And Ladakh At Srinagar And Engineering Complex Rajbagh For The Winter Season 2026-27.
Tender Value
14.72 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Overhauling And De-Scaling Of Central Heating System And Other Allied Works At High Court Of Jammu & Kashmir And Ladakh At Srinagar And Engineering Complex Rajbagh For The Winter Season 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Opening of 600 WA (HSD Boiler) for taking out steel water heating coil with chain pulley block and refitting of the same after descaling and repairs, including cost of the Baskets, washers etc complets job |
| 2 | Descaling of 600 WA (HSD Boiler) with chemicals. pumping out deposits on the surface of steel coils and pipes of hot water circulation (about 20kg of sulphuric acid powder used for dscalling) |
| 3 | Opening of 200WA (HSD Boiler) for taking out steel water heating coil with chain pulley block and refitting of the same after descaling and repairs, including cost of gaskets, washers etc cumplete job |
| 4 | Descaling of 200WA (HSD Boiler) with chamicals, pumping out desposits on the suface of steel coils and pipes of hot water circulations |
| 5 | Providing and fixing of refectory cement at the back of HSD 600 WA Boiler completes job |
| 6 | Providing and fixing of refectory cement at the back of HSD 200 WA Boiler completes job |
| 7 | General check up and cleaning of Air Handling units for free flow of air by opening of radiators/blowers including chemical washing of coils and cleaning of shafts, greasing to bearings including carriage of coils to work shop after descaling back to site of work including fitting of bearing shaft complete job. including replacement of AHU bearings of reputed make if required |
| 8 | AHU with 6 no. coiles |
| 9 | AHU with 5 no. coiles |
| 10 | AHU with single coil of size 5'x4' |
| 11 | Providing and fixing of contactors and overloads of approved make. |
| 12 | A Contactor |
| 13 | 6-10 Amp (for HSD 200WA of approved make) |
| 14 | 16 Amp with relny (for 600 WA HSD boiler of approved make |
| 15 | ML - 1 (L .D .O Boiler ) |
| 16 | B: Overload |
| 17 | 35 Amp |
| 18 | 20 - 25 Amp ( for 600 WA Boilers of approved make) |
| 19 | Opening and cleaning of radiator with blowing air and with biocorbonate solution for checking of any leakage. replacement of gaskets if needed etc and connecting back with system |
| 20 | Replacement of MCB TPN of approved Quality |
| 21 | 100 Amp |
| 22 | 63 Amp |
| 23 | 32 Amp |
| 24 | Providing and fixing of polythene to windows and ventilators of entire High Court Complex to prevent heat loss during running of central Heating system and removing of the same after conclusion of winter season to windows/ ventilators |
| 25 | Providing of Wooden beading for fixing of polythiene to all window / ventilators and door blankets |
| 26 | (3'/4') |
| 27 | 1*1/4 |
| 28 | Providing and fixing of blankets of standard quality for doors to prevent heat loss including removal of the same after conclusion of winter season |
| 29 | Refixing of old blankets including washing for doors to prevent heat loss including removal of the same after conclusion of winter season |
| 30 | Rewinding of burnt out motors of different capacities including dismantling of necessary connections, rewinding by way of replacing damaged copper wiring by suitable guage copper wire including providing and fitting of lathoride sheets, varnishing compound and other consumable items incl. shifting to workshop by mechanical transport and back to site and installing the same and checking the performance of same in full and idle load |
| 31 | 3/3.5 HP Capacity Motor. |
| 32 | 7.5 HP Capacity Motor. |
| 33 | 15/20 HP Capacity Motor. |
| 34 | Upgradationof starter delta pannels AHU's by way of chaning complete wirring / replacing of indicators / on-off push button / HRC fuse / connectors complete |
| 35 | Providing / Fixing of Belt type Air Release Valve of approved quality and make complete |
| 36 | Providing Fixing of Return Valve( raidiator) of approved quality and make complete. |
| 37 | Replacement of AHU belt of approved make of various sizes |
| 38 | Providing and fixing of Nozzel (8.5mm) of standard quality and approved by engineer in charge. |
| 39 | Providing and fixing of Photo cell 600 WA boiller of standard quality/200 WA HSD Boiler complete. |
| 40 | Providing and fixing of water pressure meter of standard quality/make as approved by EIC |
| 41 | Providing and fixing of Temperature Guage of standard quality/make as approved by engineer incharge. |
| 42 | Providing and fixing of Relay Contactor for Assembely lavato 230V /50 -60 hz DG 0910A of standard quality N make as approved by engineer incharge. |
| 43 | Providing and fixing of starter (32amp) of approved make includinf testing of same and dismentalling of de-funct starter complete. |
| 44 | Providing and fixing of 75 mm MS pipe Type-C for supply hot water to AHU in place of damaged one including dismentalling and re welded with main pipe including flanges with all carriages from source to site of work |
| 45 | Supply ,installation , testing and commissioning of 7.5 HP water lifiting motor pump set including all necessary fittings labour charges / dismentalling of old one with all carriages complete. |
| 46 | Providing Fixing of Aluminium cladding 26 gauge including glass wool and chicken mesh for hot water tank of capacity 12000 litre of approved quality and make complete |
| 47 | Providing and fixing of Aluminium cladding 26 gauge of pipes with glass wool/chicken mesh for 100mm/75mm pipe complete |
| 48 | Supply installation balancing and commissioning of factory/Fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter, hangers supports etc as per directions of EIC following sheet thickness complete required 0.63 mm sheet |
| 49 | General check up rolling shutters including greasing to make it work smoothly |
| 50 | Providing and fixing of 7.5HP Star Delta Starter PanelLT Panel Enclosure Indoor Type (Wall Mounted) measuring 24\\"(h) x 18\\"(w) x 8\\"(d) made out of 1.6mm thick CRC sheet duly powder coated comprising of:Incomer:MCB 63A FP 10kA C Curve L&T -1No. Motor Protection Relay Veritek with CT's and RYB Lamps -1SetOutgoings:Main,Delta & Star Power Contactors 25A(AC3) TP Type MNX 25 with add on contact block (L&T Make) -3No.Star-Delta Timer L&T/GIC -1No.Thermal Overload Relays ML 2 (6-10A) (L&T Make) -1No.Push Buttons with Elements -1PairOn/Off/Trip Indication Lamps -3No.Terminal Blocks, Wiring and other Panel Accessories as Requirement complete job. |
| 51 | Providing and fixing of Lever type On/Off Switch |
| 52 | Providing and fixing of in position industrial type Pressure Gauges with gunmetal/brass valves complete as required (0-10 kg/cm2 ) |
| 53 | Providing and fixing of brass ball valve of size 20mm |
| 54 | Providing and fixing of brass gate valve of size 50mm |
| 55 | Providing and fixing of nut bolts with washers of various sizes wherever required |
| 56 | Engagement of welding machine (electric/gas welding) including technician and carriage of machine from source to site of work including welding material complete job. |
| 57 | Providing and fixing of ball bearing SKF (No.6302,6303,6305) to the motors of water supply system in basement including taking out old damaged bearings including greasing oiling complete job. |
| 58 | Hot water Radiators: steel panel heating radiators with working pressure ranging from 10-13 bar having working temperature at 110 c complete with top grilles and side covers as standard along with inlet valve, outlet valve air purge valve and threaded pluf as per OFM. inlet water temp. 75 degree C outlet water temp 65 c Room temp 22 C 3000 Kcal /Hr (Double panel 2 Radiators) |
| 59 | Hot water Radiators: steel panel heating radiators with working pressure ranging from 10-13 bar having working temperature at 110 c complete with top grilles and side covers as standard along with inlet valve, outlet valve air purge valve and threaded pluf as per OFM. inlet water temp. 75 degree C outlet water temp 65 c Room temp 22 C 1500 Kcal /Hr (Double panel 2 Radiators) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender