Agriculture Government Departments Closing in 19 days TDR #58094374

Tender For Upgradation And Capacity Enhancement Of Weigh Bridge 50 To 60 Ton: Dismantling Of Existing 02 Nos. 50 Ton Weigh Bridge And Supply, Installation, Testing and Commissioning Of Replaced Weigh Bridge Members Including Girder, Plate Etc And Rel

Issued by Government Departments · Gorakhpur, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Nov 2026
19 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation And Capacity Enhancement Of Weigh Bridge 50 To 60 Ton: Dismantling Of Existing 02 Nos. 50 Ton Weigh Bridge And Supply, Installation, Testing and Commissioning Of Replaced Weigh Bridge Members Including Girder, Plate Etc And Related Work & Height Increase Of Existing 50 Mt Electronic Weigh Bridge Upto 12 Inch.02 Nos Wb At At Nmy Colonelganj

BOQ

Name of Work:- Upgradation and capacity enhancement of weigh bridge 50 to 60 Ton: Dismantling of existing 02 Nos. 50 Ton weigh bridge and S/I/T/C of replaced weigh bridge members including girder, plate etc and related work & Height increase of existing 50 MT electronic weigh bridge upto 12 inch.02 nos WB At At NMY Colonelganj
Sl. No. Item Description
1Dismentling of steel work in single section including dismembering and stacking of dismantled materials as directed by Engineer in charge with in distance of 50 m lead In:Channels,angles,tees and Flats. ISMB 250 X 125 mm 'I' shape Girder
2Ms or iron work in heavy sizes such as trusses,built up gates,door frames,record racks roof work,gates etc wroght to required form including drilling holes rivetting or welding where necessary and also including supply bolts, nuts etc. and there fixing required for proper completion of work .(SI No 503) Hardoi ISMB 300 X 140 mm 'I' shape Girder
3Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
4Dismantling of old plaster or skirting, raking out surface for plaster including disposal of rubbish to joints and cleaning the dumping ground within 50 m lead
5Supplying Installation Testing Commissioning of Client PC System comprising of PC Hardware with minimum11th Gen Intel® I7 processor CPU E5-2640x64 (or better), compatible with dual and quad core processors minimum 3.1 Ghz and 8GB or higher RAM, Hard Drive Space of 256 GB SSD or better, Video card and monitor capable of 1920 x 1080 pixel resolution or better with Ethernet adapter (10/100/1000 Mbps with RJ-45 connector) with 2 GB or higher Graphics card suitable for BMS Systemcomplete etc. as required.
6Supplying Installation Testing Commissioning of LaserJet printer having printing resolution 1200 x 1200 dpi, (dot/inch) or better, 21 to 30 ppm printing speed (LaserJet) complete etc. as required
7S/F of Digitizer suitable for 60 MT Computerised weigh bridge
8S/I/T/C of 2KVA capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port openprotocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnectingcopper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
9Providing and laying inposition cement concrete of specified grade excluding the cost of centering and shuttering with 1:2:4 (1 cement 2 coarse sandderived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources)
10Cement plaster 12mm thick with 1:4 cement and coarse sand complete in all respects
11Painting of wall with two coats of acrylic emulsion paint of approved brand
12Painting with black anti corrosive bitumastic paint of approved brand and manufacturer for even shade Two or more coats on new work
13S/F of ISI marked flush door shutters conforming to IS 2202 non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35mm thickness with stainless steel hinges and required screws
14Demolishing of RCC work manually/by mechanical means including stacking steel bars and disposal of unsevicable material within 50m lead complete in all respect.
15Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor level, excluding the cost of centering and shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 grade stone aggregate 20 mm nomial size derived from natural sources)
16Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold Twisted bars
17Centering and shuttering including strutting, propping, etc and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilever
18Providing and laying inposition cement concrete of specified grade excluding the cost of centering and shuttering with 1:2:4 (1 cement 2 coarse sandderived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources)
19Structural steel work revited, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer all complete.
20Deduct for Scrap formed after dismentling of old existing girder & plates Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58094374
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-11-2026
Authority
Authority Name Rajya Krishi Utpadan Mandi Parishad
Work Description Tender for Upgradation And Capacity Enhancement Of Weigh Bridge 50 To 60 Ton: Dismantling Of Existing 02 Nos. 50 Ton Weigh Bridge And Supply, Installation, Testing and Commissioning Of Replaced Weigh Bridge Members Including Girder, Plate Etc And Related Work & Height Increase Of Existing 50 Mt Electronic Weigh Bridge Upto 12 Inch.02 Nos Wb At At Nmy Colonelganj
Basic Detail
Tender No 2026/WB/Colonelganj/02
Bidding Type Tender
Location
City Gorakhpur
State Uttar Pradesh
Key Dates
Publish Date 17 Oct 2026
Submission Date 06 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 2500
EMD 1.38 Lakhs
Exemption Not Available
Document List
aae2d119-d43e-48f8-a911-5fe7ecbc8d82.html
BOQ_2263552.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

aae2d119-d43e-48f8-a911-5fe7ecbc8d82.html

xls

BOQ_2263552.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender