Tender For B.O.Q For Construction Of School Building At Govt. Middle School Pindobal Vailoo B.W.O Electric Work
Tender Value
5.13 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
19 days left
EMD
10279
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Construction Of School Building At Govt. Middle School Pindobal Vailoo B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. ( Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) incl. cost of conduit. |
| 2 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) incl. cost of conduit |
| 3 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (SSK/ Anchor/ ABB/Schneider or equivalent) |
| 4 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. ( SSK/ Anchor/ ABB/Schneider or eq.) |
| 5 | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. ( SSK/ Anchor/ ABB/Schneider or eq.) i.3 pin 5A - 10A socket. |
| 6 | ii. indicator. |
| 7 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) incl. cost of conduit |
| 8 | Supply, installation, testing and commissioning of 12 Watt LED recessed/ mounted (round or square) Down lighters , minimum 80lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. |
| 9 | Providing, fixing, testing and commissioning of 9 Watt LED lamp (B22 cap), BEE/ISI approved, 230 V, cool daylight (6500 K), minimum efficacy 100 lm/W, complete with heavy-duty brass batten holder, including all fixing accessories, making electrical connections, testing and commissioning as required at site. (Wipro/Philips/Crompton/Bajaj or equivalent) |
| 10 | Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 11 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd. |
| 12 | Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton). |
| 13 | Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required. |
| 14 | Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, incl. cost of conduits( Polycab/ Finolex/ Anchor/KEI/RR or equivalent). |
| 15 | 2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire |
| 16 | 2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire |
| 17 | 2 x 4 sq.mm + 1x 4 sq. mm earth wire |
| 18 | 2 x 10 sq.mm + 1x 6 sq. mm earth wire |
| 19 | Supply and fixing of 16 way Double door surface/ recess mounting , Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. . |
| 20 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 21 | Supply, installation, testing and commissioning of 32 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 22 | Supply, installation, testing and commissioning of 40 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 23 | Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. |
| 24 | Supply, laying, connecting and commissioning of 50 sq. mm 2 core PVC insulated and PVC sheathed power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. |
| 25 | Supply, installation, testing and commissioning of 1625VA Power Inverter (Pure Sine Wave type) having generator compatible & provided and fitted with 2 no. 12V, 200 Ah, tall tubular batteries of Exide/Luminus make and PVC trolley for resting/ housing of batteries. The job also includes terminal connections of batteries, input/ output leads of required size and length, carriage and applicable taxes. |
| 26 | Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs. |
| 27 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 28 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 29 | Normal INCOMING: |
| 30 | 63A DP MCCB, 10kA, Legrand/ Shinider/Semiens/ABB make. |
| 31 | b) 2 No. of Aluminium Bus Bar of 100 Amp. |
| 32 | c)Digital meters and phase indicators -1 set. |
| 33 | d) onload Change over switch 63 Amp for generator.Front operated. |
| 34 | e) 2 No. of Aluminium Bus Bar of 100 Amp. |
| 35 | c)Digital meters and phase indicators -1 set. |
| 36 | OUTGOING: |
| 37 | c) 32-40amp DP MCB c curve 10 K Legrand/ Shinider acti-9/ABB make, sample to be approved before installation.. |
| 38 | c) space for 10 way MCB's Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender