Tender For Provn Of Chlorination Plant At Various Pump Houses Alongwith Air Conditioners For Afnet Eqpt Room, Ops Room At 308 Tru And Ups And Connected Items For Partial Hq Building At Af Stn Bhuj
Tender Value
31.36 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
8 days left
EMD
62720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Chlorination Plant At Various Pump Houses Alongwith Air Conditioners For Afnet Eqpt Room, Ops Room At 308 Tru And Ups And Connected Items For Partial Hq Building At Af Stn Bhuj
BOQ
| Sl. No. | Item Description |
| 1 | S & F of Panel mounted Gas Chlorination Plant Gravity Feed type – 100 gms/Hr to 3000 gms/Hr. (standard capacity) Manufacturing supply of PVC type Gas Chlorination Plant complete with M.S. Primary Filter, PVC regulating needle valve, PVC U Tube between primary filter to secondary filter, PVC secondary filter with glass non-return valve and glass moisture tap tube with PVC nut, PVC gas bend between secondary filter to mixing chamber completed fitted with glass non-return valve, mixing chamber assembly complete fitted with big outer glass having top and bottom plate fixed with nuts and PVC NRV complete, PVC water bend fitted with Nuts and Nipple between mixing chamber to solutionizer, PVC T Set fitted with ½” valve with PVC Nuts and Nipple. All above accessories fitted on Bakelite sheet and fixed on wall with Anchor fasteners. |
| 2 | Supply only filled Chlorine Cylinder having storage capacity of 100 kg supported with test certificate issued by Chief Controller of Explosive Dept., Nagpur ll as specified and directed by Engr-in-charge. |
| 3 | Supply and laying Heavy duty UPVC pipes with all fittings and fixtures fixed to walls or laid in floor of size 20mm dia all as specified and directed by Engr-in-charge. |
| 4 | Supply and fixing UPVC gate valves, screwed/plain both ends for pvc pipe of size 20mm dia ll as specified and directed by Engr-in-charge. |
| 5 | S & F Heavy duty rubber hose pipe 2 layer wire braded having 15mm NB for chlorine outlet water ll as specified and directed by Engr-in-charge. |
| 6 | Supply only following spare parts for two year maintenace of gaseous chlorination plant and use after expire of warranty of the plant.(a) M.S. Primary Filter / Filled with Glass wool & suitable Glass moisture Trape with P.V.C. Nut complete for connection of Chlorine Gas -02 Each (b) Do- Primary Filter prepared from Corrosion proof Rigid P.V.C. Rod for long duration -02 Each(c) Glass Moisture Trap (Tube) -02 Each (d) P.V.C. Moisture Trap Nut -02 Each (e) Chlorine adjusting Needle Valve (I.S.I.) Make No. 3224 -02 Each (f) 4 inch dia Diaphgram type pressure Gauge with ½” connection for Director Mounting suitable for Chlorine gas best quality -02 Each (g) P.V.C. Pipe (‘U’ Shape) Fitted between primary & secondary filters complete -02 Each(h) 3/8” Teflon Flexible hose pipe for Cylinder to plant S.S. Wire Braided with S.S. Nut complete (h) (i)Size : 2 Meter long -02 Each (h) (ii) Size : 3 Meter long -02 Each (i) Electroplated Copper pipe with nuts & nipple connected between primary & secondary Filters as well as primary to gas Cylinder also -02 Each (j) P.V.C. Chlorine secondary filter with Glass Non Return Valve & Glass Moisture trape tube with Plastic Nuts complete -02 Each (k) P.V.C. Gas Bend with P.V.C. Nut & Glass N.R.V. complete -02 Each (l) Glass Non Return Valve -02 Each (m) Nut Plug P.V.C. for Glass N.R.V. -02 Each (n) P.V.C. Regulating Needle Valve with Backelite Wheel fitted to PVC Spindel etc. -02 Each |
| 7 | (o)Plastic mixing chamber with two Rubber Ring fitted to outer Glass tube, Orifice Glass tube and Plastic Nuts complete. -02 Each(p) Orifice Glass tube for Gas Passing -02 Each (q) Mixing chamber big outer Glass tube -02 Each(r) Mixing chamber Rubber Ring fitted on Glass tube -02 Each(s) Rubber Washer for Orifice Glass Tube -02 Each(t) Scale Patti attached on Mixing chamber -02 Each (u) P.V.C. Top Plate for mixing chamber -02 Each (v) P.V.C. Bottom Plate for mixing chamber -02 Each(w) Chlorine Solutionizer PVC complete upto 4 kg Cap. from 5 kg to 10 kg. cap.-02 Each (x) PVC Nut with Pipe for Chlorine water (outlet) (Gravity Feed) (Pressure Feed)-02 Each (y) PVC Water bend connecting Nut complete upto 4 kg. Cap. from 3 kg to 20 kg Cap.-02 Each (z)½” PVC fitting for water supply and drainage complete with valve and adaptors etc.-02 Each (aa) Do- but size 1 : Dia -02 Each(ab) ½” PVC fitting for water supply and Drainage complete with Valve & Adaptors etc. -02 Each (ac) P.V.C. Adaptor ½” -02 Each(ad) Do- but size 1” dia -02 Each (ae) ½” PVC Diaphgragm type Valve best quality -02 Each (af)Do- but size 1” dia -02 Each(ag)Washer : Lead, PVC & Rubber -02 Each (ah) PVC Injector for Pressure Feed type Chlorinator Unit -02 Each (ai)Cylinder Clamp -02 Each |
| 8 | (aj) Brass Nipple for Cylinder Clamp -02 Each (ak) Cylinder Key -02 Each Chlorine Testing Kit -02 Each (al) Teflon Tape -02 Each(am) ¾” Non-Return PVC Valve direct on line-02 Each (an)Teflon Rope 1/8” size (10 meters) -02 Each(ao) ¾” Non-Return PVC Valve direct on line -02 Each |
| 9 | Supply, install & testing air cooled split unit Air Conditioner 100% Copper condenser & copper evaporator electric driven single Phase of capacity of 2.0 TR indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating (as per 2019 BEE rating) including MS stand for outdoor unit, suction and delivery line copper material of suitable length as per site requirement complete including flexible copper cable 3 core 2.5 Sqmm appx 5 M, PVC drain pipe 20mm dia approx 15 RM of including making holes to existing wall to draw cable and pipes to connect the indoor unit to the out door unit & copper tube 10 M length including outdoor unit stand etc and making good the disturbed surfaces all as specified anf directed by Engineer In Charge. |
| 10 | Supply, install & testing air cooled split unit Air Conditioner 100% Copper condenser & copper evaporator electric driven single Phase of capacity of 1.5 TR indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating (as per 2019 BEE rating) including MS stand for outdoor unit, suction and delivery line copper material of suitable length as per site requirement complete including flexible copper cable 3 core 2.5 Sqmm appx 5 M, PVC drain pipe 20mm dia approx 15 RM of including making holes to existing wall to draw cable and pipes to connect the indoor unit to the out door unit & copper tube 10 M length including outdoor unit stand etc and making good the disturbed surfaces all as specified anf directed by Engineer In Charge |
| 11 | Supply and fix Voltage stabilizer for automatic operation, wall mounted type single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with low and high cutoff facility including under and over current protection with accuracy of ± 2.5% and of capacity 5 KVA |
| 12 | S&F sheet metal enclosure double door type (CRCA sheet) dust and vermin proof for DB's , IP 43 protection, 240 volt , fixed on wall complete and making all connections for the following capacities all as specified directed |
| 13 | MCB DB SPN 4 Way 240 Volts with 200 Amp busbar |
| 14 | S&F isolators/ MCBs,. In distribution board of the following rating and capacities. |
| 15 | MCB TPN 415 volts 63 Amps Capacity, 10 KA |
| 16 | MCB SPN 240 volts 32 Amps Capacity, 10 KA |
| 17 | S & F metal encosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 'C' series complete all as specified. |
| 18 | Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed. |
| 19 | 25 Sqmm 3.5 core |
| 20 | 10 Sqmm 2.0 core |
| 21 | M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through PVC Casing Capping and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directedNote: Two runs of conductor with one run of earth wire and one run of casing caping will be measured & paid as one unit |
| 22 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil soil complete all as specified and directed by Engineer-in-Charge. |
| 23 | Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed. |
| 24 | Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all specified and directed. |
| 25 | M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified.Note:- Punned thickness of sand shall be measured for payment. |
| 26 | M & L unreinforced precast concrete cable covers type II, flat size 300 x 180 x 40 mm laid transverse to cable. |
| 27 | M&L earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : -(a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 28 | M & L for GI strip along with flexible conduit of size 25x4 alongwith insulator complete all as specified as directed. |
| 29 | Supply & Fix Online UPS System, Microprocessor controlled IGBT based high switching frequency advance VFI inverter with isolation transformer incl input single phase AC input voltage 220/230/240 V -15%, Output single phase AC 220/230/240 V +-1% with 30 min back up of capacity 5 KVA incl Pack of 15 Nos of Battries of 180V, 30 AH Lithium-ion and incoming MCCB, incl steel rack (painted with thick enamel black paint) for 15 Nos of battries complete all as specified and directed by Engineer-in-Charge. |
| 30 | M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 6 Sqmm drawn through in and including Casing-caping of suitable size fix on surface of wall / ceiling with all accessories with 6.0 Sqmm PVC FRLSH insulated unsheathed copper conductor as earth wire, connected to common earth dolly.Note: Two runs of conductor with one run of earth wire and one run of casing caping will be measured & paid as one unit |
| 31 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing with the help of seperator, Copper strip of size 20 x 3.00 mm |
| 32 | M&L for earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground vertically to depth not less than 2.25mtr below ground level with top edge of earth plate at a depth not less than 1.5mtr below normal ground level connected to and including copper strip of 20x3mm as earth lead upto 7.5mtr long fixed by means of bolts, nuts, check nuts and washers etc. of brass including provn of GI protection pipe light grade of 32mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch 40, wire mesh and lugs, test point etc. complete. Note: copper strip exceeding 7.5m long shall be measured & paid separately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender