| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-(As per TSR 2021, Sl- 201) |
| 2 | Short point:- |
| 3 | Medium point:- |
| 4 | Long point:- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-(As per TSR 2021, Sl- 203) |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- (As per TSR 2021, Sl- 204) |
| 7 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- (As per TSR 2021 Sl- 205) |
| 8 | 2 x 1.5 sq.mm |
| 9 | 2 x 2.5 sq.mm |
| 10 | 2 x 4 sq.mm |
| 11 | 4 x 6 sq.mm |
| 12 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- - (As per TSR 2021, Sl- 503) |
| 13 | 1 x 1.5 sq.mm |
| 14 | 1 x 2.5 sq mm |
| 15 | 1 x 4 sq.mm |
| 16 | 1 x 6 sq.mm |
| 17 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required (As per TSR 2021, Sl- 1301) |
| 18 | 3 core 4 Sq mm |
| 19 | Drawing of armoured/un-armoured cable with proper saddling etc as required:-(As per TSR 2021 Item no-1511) |
| 20 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :-(As per TSR 2021 Sl- 1510) |
| 21 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- (As per TSR 2021, Sl- 717) |
| 22 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. (As per TSR 2021, Sl- 712) |
| 23 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - (As per TSR 2021, Sl- 802) |
| 24 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.:-(As per TSR 2021, Sl- 609) |
| 25 | 5 step fan regulator (2M):- |
| 26 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:- (As per TSR 2021, Sl- 811) |
| 27 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021, Sl- 1101) |
| 28 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 29 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021, Sl-1103) |
| 30 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 31 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 32 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021 Sl- 1102) |
| 33 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 34 | 9 watt/10 watt LED Bollard light with high quality polycarbonate diffuser (IP 65):- |
| 35 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
| 36 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(As per TSR 2021, Sl- 1208) |
| 37 | 2 way SPN MCB DB (single door):- |
| 38 | 4 way SPN MCB DB (double door):- |
| 39 | (2+6) / 8 way SPN MCB DB (double door):- |
| 40 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-(As per TSR 2021, Sl- 1215) |
| 41 | 6 to 32 amps SP MCB:- |
| 42 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-(As per TSR 2021, Sl- 1217) |
| 43 | 40 amps DP isolator:- |
| 44 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:-(As per TSR 2021, Sl- 1216) |
| 45 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 40 KA (1P+N) :- |
| 46 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 40 KA (3P+N) :- |
| 47 | Catridge for Surge Protection Device (SPD) (Type-2) with Imax 40 KA (1P+N) :- |
| 48 | Catridge for Surge Protection Device (SPD) (Type-2) with Imax 40 KA (3P+N) :- |
| 49 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021, Sl- 604) |
| 50 | Ding dong call bell: - |
| 51 | 32 amps DP kit kat switch:- |
| 52 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.As per TSR 2021, Sl- 605) |
| 53 | 300mm x 380mm (12\\" X 15\\") : |
| 54 | 203mm x 300mm (8\\" X 12\\") :- |
| 55 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, Sl- 1502) |
| 56 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):--(As per TSR 2021, Sl- 1519) |
| 57 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2021, Sl- 1501) |
| 58 | 40mm dia |
| 59 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:--(As per TSR 2021 Sl- 1602) |
| 60 | 900VA, 12V DC, 1 Ph input/1 Ph output inverter (Sine wave technology):- |
| 61 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:-(As per TSR 2021 Sl- 1603) |
| 62 | 12 V/ 150AH tall tubular/ flat plate Battery:- |
| 63 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.(As per TSR 2021 Sl- 609) |
| 64 | 20/25 amps single phase motor starter switch (2M):- |
| 65 | Supplying and installation of secure zone 4 kg ABC powder fire Extinguisher gross weight 6.38 kg, empty weight 2.38 kg, can height 372 mm, diameter 150 mm, discharge time minimum 13 seconds , discharge mechanism - squeeze grip type range minimum 2 meters applicable on class A,B,C and electrically started fire, A rating- 2A, raring-55B, can contrast- mig welded,valve construction- forging & machining, external coating of can..epoxy polyester powder coating, sheet metal thickness. 1.60mm, conforms to BIS standards, 5 years warranty(make. ceasefire/secure/fireshield) (Rate as per agreement no 74/EE/IED/AMB/2020-21):- Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender