Tender For Providing Annual Maintenance Contract (Amc) Of Internal Electrification Works In Teliamura Sub- Divisional Hospital, Khowai Tripura For The Financial Year 2026-27.
Tender Value
4.31 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
4 days left
EMD
8632
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Annual Maintenance Contract (Amc) Of Internal Electrification Works In Teliamura Sub- Divisional Hospital, Khowai Tripura For The Financial Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x 1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required.(TSR (IE)2021 SL.No.201) |
| 2 | Short point |
| 3 | Medium point |
| 4 | Long point |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required. (TSR (IE)2021 SL.No.203) |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required.(TSR (IE)2021 SL.No. 204) |
| 7 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required. (TSR (IE)2021 SL.No.205) |
| 8 | 2 x 1.5 sq mm |
| 9 | 2 x 2.5 sq mm |
| 10 | 2 x 6 sq mm |
| 11 | Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required. (TSR (IE)2021 SL.No. 503) |
| 12 | 1 x 1.5 sq mm |
| 13 | 1 x 4 sq.mm |
| 14 | 4 x 16 sq.mm |
| 15 | 4 x 35 sq mm |
| 16 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR-2021, Sl-1501) |
| 17 | 40 mm dia |
| 18 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-(As per TSR-2021, Sl-1502) |
| 19 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required:- (As per TSR-2021, Sl-1505) |
| 20 | Supplying and fixing of powder coated sheet steel enclosure on surface/ recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/ SPN/ DP/ TP/ TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(TSR (IE)2021 SL.No.1208) |
| 21 | 2 way SPN MCB DB (single door) |
| 22 | 4 way MCB DB (single door) |
| 23 | 2+6 / 8 way MCB DB (single door) |
| 24 | 2+10 / 12 way MCB DB (single door) |
| 25 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required. (TSR (IE)2021 SL.No.1215) |
| 26 | 6 to 32 amps SP MCB |
| 27 | 40/50/63 amps TP MCB |
| 28 | 40/50/63 amps FP MCB |
| 29 | Supplying & fixing of following ratings isolator in the existing MCB DB including connection etc as required. (TSR (IE)2021 SL.No.1217) |
| 30 | 40 amps DP isolator |
| 31 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-(As per TSR-2021, Sl-1219) |
| 32 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 33 | 250 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 34 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt) (TSR (IE)2021 SL.No.1101) |
| 35 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser |
| 36 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 37 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR-2021, Sl-1102) |
| 38 | 60 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 39 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):-- |
| 40 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR-2021, SL-1103) |
| 41 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 42 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. (TSR (IE)2021 SL.No.607) |
| 43 | 3 module plastic switch board |
| 44 | 6 module plastic switch board |
| 45 | 8 module plastic switch board |
| 46 | 12 module plastic switch board |
| 47 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. (TSR (IE)2021 SL.No.607) |
| 48 | 3 module |
| 49 | 6 module |
| 50 | 8 module |
| 51 | 12 module |
| 52 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required.(TSR (IE)2021 SL.No.601) |
| 53 | 25 x 12mm |
| 54 | 32 x 12mm |
| 55 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. (TSR (IE)2021 SL.No.602) |
| 56 | 25 mm dia |
| 57 | 32 mm dia |
| 58 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.(TSR (IE)2021 SL.No.609) |
| 59 | 6/10 amps one way SP switch (1M) |
| 60 | 16/20 amps one way SP switch (1M) |
| 61 | 3 pin 6/10 amps socket outlet (2M) |
| 62 | 3/6 pin 16/20 amps socket outlet (2M) |
| 63 | 5 step fan regulator (2M) |
| 64 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(TSR (IE)2021 SL.No.604) |
| 65 | Angle/batten/pandent holder |
| 66 | Ceiling rose |
| 67 | 2.5 mfd fan capacitor |
| 68 | 20/25 amps single phase motor starter switch (2M) |
| 69 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2 x 1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3 /min /W) (TSR (IE)2021 SL.No.802) |
| 70 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length (up to 30 cm) etc. as required.(TSR (IE)2021 S.L No.829) |
| 71 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:-(As per TSR-2021, Sl-810) |
| 72 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes.(TSR(IE)2021 SL.No.1402) |
| 73 | 2.5 sq mm |
| 74 | 4 sq mm |
| 75 | 6 sq mm |
| 76 | 16 sq mm |
| 77 | 35 sq mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender