Tender For Repairs To Cooling Appliances (Water Coolers, Desert Coolers, Split/Window Acs, Deep Freezers And Refrigerators) Under Age E/M (N) Of Ge (N) Secunderabad.
Tender Value
40 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
11 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Medchal Malkajgiri → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Cooling Appliances (Water Coolers, Desert Coolers, Split/Window Acs, Deep Freezers And Refrigerators) Under Age E/M (N) Of Ge (N) Secunderabad.
BOQ
| Sl. No. | Item Description |
| 1 | M&L Cleaning and servicing of Split Type 1.5 Ton/2.0 Ton AC including repair of all loose electrical connections, abnormal noise in indoor/outdoor unit, foundation, power contactor etc including TOP UP of suitable gas complete all as specified and directed by Engg in charge. Note: Replacement of any spares will be measured and paid separtely |
| 2 | M&L Cleaning and servicing of cassette type 4 Ton AC including repair of all loose electrical connections, abnormal noise in indoor/outdoor unit, foundation, power contactor etc including TOP UP complete all as specified and directed by Engg in charge. Note: Replacement of any spares will be measured and paid separtely |
| 3 | M&L Checking the leakage of Split type 1.5 Ton/2.0 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied on the unit complete all as specified and directed by Engg in charge. Note: Replacement of capillary tube will be paid and measured seperately |
| 4 | M&L Checking the leakage of cassette type 4 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied on the unit complete all as specified and directed by Engg in charge. Note: Replacement of capillary tube will be paid and measured seperately |
| 5 | S&F in replacement of 1/2 inch copper pipe along with insulation material suitable forr Split AC 1.5 Ton/2 Ton of suitable make as per sample complete all as specified directed by Engg in Charge. |
| 6 | All as per Item No. 5 above,but 1/4 inch copper pipe along with insulation material |
| 7 | All as per Item No. 5 above,but 5/8 inch copper pipe along with insulation material |
| 8 | All as per Item No. 5 above,but Capacitor 45+/- 2 mfd |
| 9 | All as per Item No. 5 above,but Capacitor 60+/-6 mfd |
| 10 | All as per Item No. 5 above,but Capacitor 2.5 mfd |
| 11 | All as per Item No. 5 above,but Capacitor 4 mfd |
| 12 | All as per Item No. 5 above,but Capacitor 6 mfd |
| 13 | All as per Item No. 5 above,but Panel Board of suitable make as per sample |
| 14 | All as per Item No. 5 above,but Fan blade |
| 15 | All as per Item No. 5 above,but Fan motor |
| 16 | All as per Item No. 5 above,but Condenser coil unit complete |
| 17 | All as per Item No. 5 above,but valve of 1/2 or 1/4 or 5/8 |
| 18 | All as per Item No. 5 above,but Flarry nut 1/4, 3/8, 5/8 and 1/2 |
| 19 | All as per Item No. 5 above,but Evaporator Coil |
| 20 | All as per Item No. 5 above,but Indoor motor |
| 21 | All as per Item No. 5 above,but Swing motor complete of suitable size as per sample |
| 22 | All as per Item No. 5 above,but swing blade |
| 23 | All as per Item No. 5 above,but Room sensor |
| 24 | All as per Item No. 5 above,but Coil sensor |
| 25 | All as per Item No. 5 above,but Dead plug of Brass Type |
| 26 | All as per Item No. 5 above,but Complete Rewiring of Outdoor Split AC |
| 27 | All as per Item No. 5 above,but Universal Remote |
| 28 | S&F in Replacement of Indoor Unit capacity 2 Ton complete set as per Sample and Existing Make complete all as specified directed by Engg in Charge. |
| 29 | S&F in Replacement of Outdoor Unit capacity 2 Ton complete set as per sample and Existing Make complete all as specified directed by Engg in Charge. |
| 30 | S&F in Replacement of Heavy duty compressor terminal Pin as per sample complete all as specified directed by Engg in Charge. |
| 31 | S&F in Replacement of Inlet water PVC pipe 20mm dia along with clamps complete all as specified directed by Engg in Charge. |
| 32 | S&F in Replacement of Flexible PVC pipe of 20mm dia as per sample complete all as specified directed by Eng- in- Charge. |
| 33 | S&F in replacement of Copper pipe along with insulation suitable for Cassette AC 4 Ton capacity of suitable make as per sample complete all as specified and directed by Eng- in- Charge. |
| 34 | All as per Item No.33 above,but Capacitor 80-100 mfd |
| 35 | All as per Item No. 33 above,but Blower Motor |
| 36 | All as per Item No. 33 above,but Blower |
| 37 | All as per Item No. 33 above,but Cooling Coil |
| 38 | All as per Item No. 33 above,but Drain Motor |
| 39 | All as per Item No. 33 above,but PCB Board for indoor |
| 40 | All as per Item No. 33 above,but Swing Motor |
| 41 | All as per Item No. 33 above,but Drain Motor Sensor |
| 42 | All as per Item No. 33 above Room Sensor |
| 43 | All as per Item No. 33 above Coil Sensor for indoor |
| 44 | All as per Item No. 33 above Drain Tray |
| 45 | All as per Item No. 33 above PCB Board for outdoor |
| 46 | All as per Item No. 33 above Fan motor |
| 47 | All as per Item No. 33 above Fan Blade |
| 48 | All as per Item No. 33 above Coil sensor for outdoor |
| 49 | All as per Item No. 33 above HP/LP Sensor |
| 50 | All as per Item No. 33 above Capacitor 10mfd |
| 51 | All as per Item No. 33 above Contactor |
| 52 | All as per Item No. 33 above Condenser Coil |
| 53 | All as per Item No. 33 above Single Phase Preventor |
| 54 | All as per Item No. 33 above valve |
| 55 | All as per Item No. 33 above Connectors |
| 56 | S&F in replacement of Outdoor unit Stand for fixing in wall complete all as specified and directed by Engg in Charge. |
| 57 | Disconnecting the Electrical connection, removing the copper line, discharge line of Split AC 1.5/2.0 Ton/2 Ton/Casette AC 4 Ton capacity including indoor and outdoor units and all accessories and shifting/re-installing and testing the whole unit of Split AC/Casette AC in the same location and checking the leakage of Split type 1.5/2.0 Ton AC/2 Ton/Casette AC 4 Ton with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied in suitable size and length of copper pipe and making the holes in wall complete all as specfied and directed by Engg in Charge |
| 58 | S&F in replacement of Factory made hermatically sealed compressor for Split Type AC 1.5 Ton capacity of any make including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc including necessary transport from units to work shop and back to units after repairs complete all as specified and directed by Eng- in- Charge.Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and back.Note 2: Rates deemed to be included for the gas required for charging |
| 59 | All as per Item No.58 above,but Split Type AC 2.0 Ton capacity |
| 60 | All as per Item No.58 above,but Cassette type AC 4.0 Ton Capacity |
| 61 | Taking down existing Indoor & Outdoor unit of cassette type of make : Voltas and S & F the Indoor & Outdoor unit complete Make: Voltas of capacity 4 Ton Model: 4 TR Venture Cassette and charge the N2 Gas to check the leakage and charge the suitable refrigerant upto required level as specified on the unit and test the complete AC for all the safety devices incorporated complete all as specified and directed by Eng-In- Charge. |
| 62 | S&F in replacement of Modular Sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 230 Volts of 25-32 Amps complete all as specified and as directed. |
| 63 | S&F in replacement of Plug Tops of 16 Amps all as specified and directed by Engg-in-Charge |
| 64 | M&L Repairs of Split/cassette AC i.e water drain leakage problem detection and refitting the same in entire system including testing and commissioning complete serviceable for Split AC 1.5/2.0 Ton and Cassette type AC 4.0 Ton complete all as specified and directed by Engg in Charge. |
| 65 | Water cooler servicing and including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of water coolers of 40/80 ltrs capacity complete all as specified and as directed. |
| 66 | S&F in replacement of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs of Water Coolers 40/80 LtrsNote 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and backNote 2: Rates deemed to be included for the gas required for charging |
| 67 | S&F in replacement of Relay package assembly as per Existing Model suitable for Water coolers of 40/80 Ltrs capacity complete al as specified and directed by Eng-in-charge. |
| 68 | All as per Item No.67 above,but Thermostat/cooling sensor complete unit |
| 69 | All as per Item No.67 above,but Capillary tube including filter/stainer |
| 70 | All as per Item No.67 above,but Condenser fan motor 1/16 HP 230 volts including blades complete |
| 71 | All as per Item No.67 above,but PVC Ball valve high pressure with polythene float and fly nut complete for iron pipe 15mm dia |
| 72 | All as per Item No.67 above,but Magnetic door gasket for complete unit |
| 73 | All as per Item No.67 above,but GI/Stainless steel water drain tray |
| 74 | All as per Item No.67 above,but Self closing taps, cast copper alloy, chromium plated serewed for iron pipe 15mm dia |
| 75 | All as per Item No.67 above,but Timer switch |
| 76 | All as per Item No.67 above,but PCB as per sample |
| 77 | All as per Item No.67 above,but OLP as per sample |
| 78 | All as per Item No.67 above,but Fan motor |
| 79 | All as per Item No.67 above,but Fan blade |
| 80 | All as per Item No.67 above,but Capacitor 10-15 mfd |
| 81 | All as per Item No.67 above,but Blower as per sample |
| 82 | M&L Denting and Spray painting with two coats of synthetic enamel paint over a coat of red oxide primer including repairs of legs for water coolers complete all as specified and directed by Eng-In- Charge. |
| 83 | S&F in replacement of Water circulating pump 1/70 HP capacity single phase 230 Volts 1340 RPM 1.5 Mtr Head suitable for Desert Cooler of any make and size complete all as specified and directed by Eng-in-charge. |
| 84 | All as per Item No.83 above,but Khas-Khas screen complete set for Each Cooler |
| 85 | All as per Item No.83 above,but Float valve suitable for any type of desert coolers 230 volts 50 Hz |
| 86 | All as per Item No.83 above,but PVC Pipe suitable for any type desert cooler 230 volts 50 Hz |
| 87 | All as per Item No.83 above,but Fan motor variable speed 230 volts 50 Hz 1/13 HP complete set |
| 88 | All as per Item No.83 above,but Swing Motor |
| 89 | All as per Item No.83 above,but Swing Blade |
| 90 | All as per Item No.83 above,but Fan Blade |
| 91 | All as per Item No.83 above,but Selector Switch heavy duty |
| 92 | All as per Item No.83 above,but opening shutter for desert cooler |
| 93 | All as per Item No.83 above,but Distributor complete set |
| 94 | All as per Item No.83 above,but Metallic front grill for Desert cooler |
| 95 | All as per Item No.83 above,but PVC front grill for desert cooler |
| 96 | S&F 15mm dia bore Steel water tubing of medium grade duly ISI marked galvanised of including all fittings such as tees, bends and elbow reducer, unions, clamps including cutting the existing line of 20/25 mm dia and connecting complete all as specified. |
| 97 | Refrigerator servicing, testing and commissioning of Refrigerator of 260 to 310 ltrs capacity including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, complete all as specified and as directed. |
| 98 | S&F in replacement of Factory made hermatically sealed compressor for Refrigerator of 260 to 310 ltrs capacity of any make including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc including necessary transport from units to work shop and back to units after repairs complete all as specified and directed by Eng-in-charge.Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and back.Note 2: Rates deemed to be included for the gas required for charging |
| 99 | S&F in replacement of Relay package assembly as per Existing Model suitable for Refrigerator of 260 to 310 ltrs capacity complete all as specified and directed by Eng- in- Charge. |
| 100 | All as per Item No.99 above,but Thermostat/cooling sensor |
| 101 | All as per Item No.99 above,but Capillary tube including filter/stainer |
| 102 | All as per Item No.99 above,but Condenser fan motor 1/16 HP 230 volts including blades complete |
| 103 | All as per Item No.99 above,but PVC Ball valve high pressure with polythene float and fly nut complete for iron pipe 15mm dia |
| 104 | All as per Item No.99 above,but Magnetic door gasket for complete unit |
| 105 | All as per Item No.99 above,but PVC body tray |
| 106 | All as per Item No.99 above,but Fan Blade |
| 107 | All as per Item No.99 above,but cooling coil/freezer |
| 108 | All as per Item No.99 above,but condenser |
| 109 | All as per Item No.99 above,but Bulb |
| 110 | All as per Item No.99 above,but Biometer Fuse |
| 111 | All as per Item No.99 above,but Heater |
| 112 | All as per Item No.99 above,but Timer |
| 113 | All as per Item No.99 above,but Time delay |
| 114 | All as per Item No.99 above,but Door lock with Key |
| 115 | S&F in replacement of Rectifier unit as per sample suitable for voltage stabilizer of single phase upto 4/5 KVA capaicty complete all as specified directed by Eng- in- Charge. |
| 116 | All as per Item No. 115 above,but Relay unit as per sample |
| 117 | All as per Item No. 115 above,but Indication lamp set |
| 118 | All as per Item No. 115 above,but Volt meter 0-250 Volts,AC,single phase |
| 119 | All as per Item No. 115 above,but Power supply control card |
| 120 | All as per Item No. 115 above,but Low cut High cut Time delay card |
| 121 | All as per Item No. 115 above,but 9-0-9/12-0-12 Transformer |
| 122 | All as per Item No. 115 above,but Power connectors |
| 123 | All as per Item No. 115 above,but Main Transformer Circuit |
| 124 | Deep Freezer servicing, testing and commissioning of Deep Freezer of 320 to 400 ltrs capacity including supply and charging of refrigerant R-22 or any type gas including cost of welding, leak detection, making good the defects in entire system,complete all as specified and directed. |
| 125 | S&F in replacement of Factory made hermatically sealed compressor for Deep Freezer of 320 to 400 ltrs capacity of any make including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc including necessary transport from units to work shop and back to units after repairs complete all as specified and directed by Eng-in-charge.Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and back.Note 2: Rates deemed to be included for the gas required for charging |
| 126 | S&F in replacement of Relay package assembly as per existing model and make suitable for Deep Freezer of capacity 320 to 400 Ltrs complete all as specified and directed by Eng- in- Charge. |
| 127 | All as per Item No.126 above,but Thermostat/cooling sensor |
| 128 | All as per Item No.126 above,but capillary tube including filter/strainer |
| 129 | All as per Item No.126 above,but condensor fan motor 1/16 HP 230V including blades complete |
| 130 | All as per Item No.126 above,but Magnetic door gasket for complete unit |
| 131 | All as per Item No.126 above,but Cooling coil/Freezer |
| 132 | All as per Item No.126 above,but Condensor |
| 133 | All as per Item No.126 above,but Biometer Fuse |
| 134 | All as per Item No.126 above,but Heater |
| 135 | All as per Item No.126 above,but Timer |
| 136 | All as per Item No.126 above,but Time delay |
| 137 | All as per Item No.126 above,but Codensor motor Please Enable Macros to View BoQ information |
| 138 | All as per Item No.126 above,but Codensor motor Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender