Tourism Government Departments Closing in 33 days TDR #58086773

Tender For Village Infrastructure Upgradation And Facilities Development At Khola, Kangsali, Sandana, Dharkot, Mandan Negi

Issued by Government Departments · Tehri Garhwal, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Nov 2026
33 days left
EMD
1.10 Crore
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tehri Garhwal → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Village Infrastructure Upgradation And Facilities Development At Khola, Kangsali, Sandana, Dharkot, Mandan Negi

BOQ

Name of Work:- Village infrastructure upgradation and facilities development at Khola, Kangsali, Sandana, Dharkot, Mandan Negi
Sl. No. Item Description
1Sandana Village
2Entrance Gate
3Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
61:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
7Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
8Concrete of M25 grade with minimum cement content of 330 kg /cum
9Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
10Concrete of M25 grade with minimum cement content of 330 kg /cum
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
12Thermo-Mechanically Treated bars of grade Fe-500D or more.
13Centering and shuttering including strutting, propping etc. and removal of form for
14Foundations, footings, bases of columns, etc. for mass concrete
15Lintels, beams, plinth beams, girders, bressummers and cantilevers
16Columns, Pillars, Piers, Abutments, Posts and Struts
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
18Cement Plaster in (Fine Sand)
1912 mm cement plaster :1:6 (1 cement : 6 Fine sand)
20Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
218 mm thick, Raj nagar plain white marble/ Udaipur green marble/ Zebra black marble
22Supply and Installation of Shingles of Approved make, design and sizes and as per instrcution of Engineer-in-charge.
23Providing and fixing exterior decorative WPC Panels as per approved design and make and as per direction of Engineer-in-charge.
24Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
25Pathway Upgradation
26Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
27Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
28Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
29Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
30Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
31Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
32Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
33Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
34Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
35Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
36For Grading I Material
37Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
38PCC Grade M15
39Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
40Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
41PCC M15 for Kerb base
42PCC M20 for Kerb (Cast in Situ)
43Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
44Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
45Plaster & Painting on Village Walls
46Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
47Cement Plaster in (Coarse Sand)
4820 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
49New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
50Renovation of Panchayat Bhavan
51Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge.
52Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
53Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
54In cement mortar
55Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
56Of area 3 sq. metres and below
57Of area beyond 3 sq. Metres
58Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
5912 mm cement plaster of mix ( in coarse sand)
601:4 (1 cement: 4 coarse sand)
61Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
62With cement mortar 1:4 (1cement: 4 coarse sand)
63Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
64Door chowkhats
65Window chowkhats
66Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
67For thickness of tiles 10 mm to 25 mm
68Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
69Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
70Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet Complete.
71Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
72110 mm diameter
73Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
74Coupler, 110 mm
75Bend 87.5°, 110 mm bend
76Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.
77110 mm diameter
78Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
79Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
80Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
81Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
82Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
83Open Air Theatre
84Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
85Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
86Ordinary soil, up to 3m depth
87Ordinary rock (not requiring blasting) up to 3 m depth
88Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
89Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
90Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
91Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
92Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
931:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
94Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
95Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
96Cement Plaster in (Coarse Sand)
9712 mm cement plaster :1:6 (1 cement : 6 Fine sand)
98Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
99Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
100Random Rubble Masonry in 1:3 cement mortar
101Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
102Random Rubble Masonry in 1:3 cement mortar
103Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
104Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
105Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
106Providing and laying Lime stone river finish flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
107Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
108Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
109Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
110For Grading I Material
111Providing and laying 75 x 75 x 18 mm thick Phylitte Tumbled stone for flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
112Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever Required.
1130.80 mm thick with zinc coating not less than 275 gm/m?
114Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
1150.80 mm thick with zinc coating not less than 275 gm/m?
116Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
117Community Area Development & Other Misc Utilities
118Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
119Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
120Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
121Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m in ordinary rock.
122Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
123Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
124Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
125Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :
126Screened through sieve of I.S. designation 16 mm
127Fine dressing of the ground.
128Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
129Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
130Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408, using concrete mixer
131PCC M15 for Kerb base
132PCC M20 for Kerb (Cast in Situ)
133Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
1341:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
135Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
136Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
137For Grading I Material
138Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504
139Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
140Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
141Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bag of size 20 cm as per direction of the Officer-in-charge.
142Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
143Supplying & Stacking of Selection No.1 grass turf at site fresh & free from weeds having proper roots, lush green including loading, unloading, carriage and all taxes paid etc. and as per direction of the officer-in-charge.
144Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).
145In rows 5 cm apart in both directions
146Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for Separately)
147Holes 1.2 m dia and 1.2 m deep
148Holes 60 cm dia, and 60 cm deep
149Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
150Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water).
151Trees plant
152Shrubs Plant
153Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
154Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
155Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
156Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
157Supply of materials and installation of Gazebos of approved make and design and as per instructions of Engineer-in-charge.
158Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
159Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
160Construction of Recharge Pits as per drawing and instruction of Engineer-in-charge.
161Chain Link Fencing
162Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
163Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
164Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
1651:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
166Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
167Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
168Concrete of M25 grade with minimum cement content of 330 kg /cum
169Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
170Concrete of M25 grade with minimum cement content of 330 kg /cum
171Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
172Thermo-Mechanically Treated bars of grade Fe-500D or more.
173Centering and shuttering including strutting, propping etc. and removal of form for
174Foundations, footings, bases of columns, etc. for mass concrete
175Columns, Pillars, Piers, Abutments, Posts and Struts
176Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
177Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
178Cement Plaster in (Coarse Sand)
17912 mm cement plaster :1:4 (1 cement : 4 coarse sand)
180Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
181Finishing walls with textured exterior paint of required shade :
182New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
183Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
184PHE Works
185Drainage System Works
186Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
187Pipes, cables etc, not exceeding 80 mm dia.
188Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
189Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
190Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
191Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
192100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
193Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
194150 mm dia. R.C.C. pipe
195250 mm dia. R.C.C. pipe
196Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
197Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
198Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
199Extra for depth for manholes
200Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
201Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
202Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
203With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
204Water Supply Works
205Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20615 mm nominal dia Pipes
20720 mm nominal dia Pipes
20825 mm nominal dia Pipes
209Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
21015 mm nominal dia Pipes
21120 mm nominal dia Pipes
21225 mm nominal dia Pipes
213Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
21415 mm dia nominal bore
21520 mm dia nominal bore
21625 mm dia nominal bore
21780 mm dia nominal bore
218Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
21925 to 40 mm nominal bore
220Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
221Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
22220 mm nominal bore
22325 mm nominal bore
22480 mm nominal bore
225Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
22615 mm nominal bore
22720 mm nominal bore
22825 mm nominal bore
229Providing and fixing gun metal non- return valve of approved quality (screwed end) :
23025 mm nominal bore Horizontal
23180 mm nominal bore Horizontal
232Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
23325 mm nominal bore
234Providing and fixing uplasticised PVC connection pipe with brass unions :
23530 cm length, 15 mm nominal bore
236Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
237With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
238Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
239Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
24015 mm nominal bore
241Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
24215 mm nominal bore
243Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
24415 mm nominal bore
245Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
24680 mm nominal bore
247Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
248Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
249Sanitary Works
250Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
251W.C. pan with ISI marked white solid plastic seat and lid
252Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
253White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
254Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
255Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
256Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
25732 mm dia
258Providing and fixing 100 mm sand cast Iron grating for gully trap.
259Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
260Rectangular shape 1500x450 mm
261Providing and fixing toilet paper holder :
262C.P. brass
263100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
26475 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
265Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
266For 100 mm dia pipe
267For 75 mm dia pipe
268Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
269For 100 mm dia, Sand cast iron S&S as per IS – 3989
270For 75 mm dia, Sand cast iron S&S as per IS - 3989
271Providing and fixing bend of required degree .
272100mm dia, Sand cast iron S&S as per IS - 3989
273For 75 mm dia, Sand cast iron S&S as per IS - 3989
274Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
275100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
276100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
277Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
278Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
279Supply of Bio-digestor tank of 2000 litre capacity with bacteria, material - Fibre reinforced plastic (FRP) with inliet and outlet pipe and gas pipe- Size of rectangular tank - 1460 mm (length) x 1360 mm (width) x 1000 mm (Height). Wall thickness of tank - 5 mm, Top and bottom thickness - 7 mm. Outlet water parameters shall be in accordance with the waster water norms.
280Electrical Works
281ROAD LIGHTNING
282Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
283Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629
284OPEN AIR THEATER
285Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
286Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
287Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
28840Watt, Color Temp 3000-5700k as required
289Supply,Installation, Testing, Commissioning of 12W LED Garden spike light fixture, well-designedmodern and rugged Garden Spike is a great addition to highlight your garden spaces. COB integratedlighting keeps the product high on light dispersion and efficiency. Key features are 80% energy savings,outdoor ambient lighting , protection against dust & jet of water from any direction, IP65 fixture ideal foroutdoor & wet areas, housing made with aluminium with black finish, LED integrated, IP65 protection,system wattage: 12W at system lumens of 675lm, CCT: 3000K, product dimension: 131mm x 89mm x243mm (±10%), Similar to Signify or Philip Cat. Ref no: Spike light 12W (Model no: 800139) orEquivalent as per meeting Tender Specs.
290Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
291Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
292Supply,Installation, Testing, Commissioning of 5W surface mounted LED Step light fixture, The neatly designed modern and minimal step light melds into the background settings and provides just the right ambient illumination to create an interesting setting. Key features are: LED light with beautiful light pattern, Highlight the outdoors, Endurance meets contemporary style, Clean lines, sleek design, warm white light, Robust finish, Long life LED source, housing made with aluminium & Anthracite grey finish, LED integrated, IP44, system wattage of 5W with system lumen of 165lm @ 3000K, product dimension of (L x W x H): 201mm x 91mm x 35mm, Similar to Signify or Philip Cat. Ref no: 31436 or Equivalent as per meeting Tender Specs.
293PANCHAYAT BHAWAN
294Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
295Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
296Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
297Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
298Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2992x2.5 sq. mm + 1x2.5 sq. mm earth wire
3002x4 sq. mm + 1x4 sq. mm earth wire
301Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
3024x4 Sqmm +2x4 sqmm earth wire
303Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
304Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3054C X 25 Sq.mm Aluminium cable
306Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
307Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
308Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
3091 or 2 Module (75 mm x 75 mm)
3103 Module (100 mm x 75 mm)
3116 Module (200 mm x 75 mm)
31212 Module( 200 mm x 150mm)
313Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
314Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
315Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
316Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
317Bell push
318Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
3199- 10 watt
320Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
3211200mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
322Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
3236 way, Double door
324Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
3256 way (4 + 18), Double door
326Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
327Single pole
328Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32963 Amp
330Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
331Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
332Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
333COMMUNITY AREA DEVELOPMENT
334Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
335Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
336Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
337Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
338Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
3392x2.5 sq. mm + 1x2.5 sq. mm earth wire
3402x4 sq. mm + 1x4 sq. mm earth wire
3412x10 sq. mm + 1x6 sq. mm earth wire
3422x16 sq. mm + 1x6 sq. mm earth wire
343Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
3444x4 Sqmm +2x4 sqmm earth wire
345Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
346Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3474C X 25 Sq.mm Aluminium cable
348Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
349Upto 35 sq. mm
350Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
351Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
3521 or 2 Module (75 mm x 75 mm)
3533 Module (100 mm x 75 mm)
3546 Module (200 mm x 75 mm)
35512 Module( 200 mm x 150mm)
356Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
357Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
358Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
359Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
360Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
3619- 10 watt
362Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
3636 way, Double door
364Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
3656 way (4 + 18), Double door
366Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required.
367For 6 way, Double door SPN MCBDB
368Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
369Single pole
370Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
37163 Amp
372Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
373Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
374Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
375Providing & Fixing of Double ball Bearing copper wounded capacitor start single phase metallic blade fresh air fan in existing opening including cost of hardware flexible 3 core copper making connection testing etc.300mm Sweep
376Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
377Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
37840Watt, Color Temp 3000-5700k as required
379Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
380SOLAR PV PLANT
381Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
382Khola Village
383Pathway Upgradation
384Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
385Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
386Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
387Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
388Carriage of dismantled materials up to a lead of 5 km
389Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
390Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
391Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
392Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
393Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
394Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
395For Grading I Material
396Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
397PCC Grade M15
398Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
399Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
400PCC M15 for Kerb base
401PCC M20 for Kerb (Cast in Situ)
402Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
403Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
404Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
405Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.
406Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects.
407Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects.
408Plaster & Painting on Village Walls
409Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
410Cement Plaster in (Coarse Sand)
41120 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
412New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
413Renovation of Panchayat Bhavan
414Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge.
415Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
416Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
417Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
418In cement mortar
419Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
420Of area 3 sq. metres and below
421Of area beyond 3 sq. Metres
422Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
423Concrete of M25 grade with minimum cement content of 330 kg /cum
424Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
425Thermo-Mechanically Treated bars of grade Fe-500D or more.
426Centering and shuttering including strutting, propping etc. and removal of form for
427Suspended floors, roofs, landings, balconies and access platform
428Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
42912 mm cement plaster of mix ( in coarse sand)
4301:4 (1 cement: 4 coarse sand)
431Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
432With cement mortar 1:4 (1cement: 4 coarse sand)
433Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
434Door chowkhats
435Window chowkhats
436Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
437For thickness of tiles 10 mm to 25 mm
438Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
439Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
440Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
441Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
442Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
443Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
444Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
445Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet Complete.
446Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
447110 mm diameter
448Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
449Coupler, 110 mm
450Single tee with door, 1100mm x 110 mm x 110 mm
451Bend 87.5°, 110 mm bend
452Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.
453110 mm diameter
454Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
455Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
456School Repair & Rehabilitation
457Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
458Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
459Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
460Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
461Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
462For Grading I Material
463Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
464PCC Grade M15
465Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
466Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
467PCC M15 for Kerb base
468PCC M20 for Kerb (Cast in Situ)
469Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
470With cement mortar 1:4 (1cement: 4 coarse sand)
471Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
472Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
473Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
474Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
475Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
476Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
477W.C. pan with ISI marked white solid plastic seat and lid
478Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
479Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
480Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
481White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
482Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
483Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
48410 litre (full flush) capacity-white
485Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
486Flexible pipe, 32 mm dia
487Providing and fixing 100 mm sand cast Iron grating for gully trap.
488Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
489Rectangular shape 1500x450 mm
490Providing and fixing toilet paper holder :
491C.P. brass
492100 mm dia Sand cast iron S&S pipe as per IS: 1729
49375 mm dia Sand cast iron S&S pipe as per IS: 1729
494Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
49575 mm dia pipe
496100 mm dia pipe
497Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
498For 100 mm dia pipe
499For 75 mm dia pipe
500Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
501100 mm diameter pipe
50275 mm diameter pipe
503Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
504Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
505Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
506450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
507Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge for Concealed work, including cutting chases and making good the walls etc.
50815 mm nominal outer dia Pipes
50920 mm nominal outer dia Pipes
51032 mm nominal outer dia Pipes
511Providing and fixing brass bib cock of approved quality :
51215 mm nominal bore
51320 mm nominal bore
514Providing and fixing brass stop cock of approved quality :
51515 mm nominal bore
51620 mm nominal bore
517Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
51825 mm nominal bore
51932 mm nominal bore
520Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
52120 mm nominal bore
52225 mm nominal bore
523Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately
524Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
525Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
526Construction of Vat Chamber as per drawing & all required civil works and as per direction of Engineer-in-charge.
527Supply and Installation of WATER ATM of approbed make and design and as per the direction of the Engineer-in-charge.
528Open Air Theatre
529Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
530Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
531Ordinary soil, up to 3m depth
532Ordinary rock (not requiring blasting) up to 3 m depth
533Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
534Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
535Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
536Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
537Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
5381:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
539Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
540Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
541Cement Plaster in (Coarse Sand)
54212 mm cement plaster :1:6 (1 cement : 6 Fine sand)
543Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
544Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
545Random Rubble Masonry in 1:3 cement mortar
546Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
547Random Rubble Masonry in 1:3 cement mortar
548Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
549Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
550Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
551Providing and laying Lime stone river finish flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
552Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
553Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
554Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
555For Grading I Material
556Providing and laying 75 x 75 x 18 mm thick Phylitte Tumbled stone for flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
557Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever Required.
5580.80 mm thick with zinc coating not less than 275 gm/m?
559Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
5600.80 mm thick with zinc coating not less than 275 gm/m?
561Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
562Community Area Development & Other Misc Utilities
563Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
564Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
565Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
566Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m in ordinary rock.
567Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
568Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
569Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
570Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :
571Screened through sieve of I.S. designation 16 mm
572Fine dressing of the ground.
573Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
574Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
575Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408, using concrete mixer
576PCC M15 for Kerb base
577PCC M20 for Kerb (Cast in Situ)
578Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
5791:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
580Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
581Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
582For Grading I Material
583Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504
584Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
585Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
586Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bag of size 20 cm as per direction of the Officer-in-charge.
587Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
588Supplying & Stacking of Selection No.1 grass turf at site fresh & free from weeds having proper roots, lush green including loading, unloading, carriage and all taxes paid etc. and as per direction of the officer-in-charge.
589Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).
590In rows 5 cm apart in both directions
591Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for Separately)
592Holes 1.2 m dia and 1.2 m deep
593Holes 60 cm dia, and 60 cm deep
594Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
595Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water).
596Trees plant
597Shrubs Plant
598Construction of View Point as per drawing and as per instruction of Engineer in charge inclusive of all civil works.
599Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
600Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
601Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
602Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
603Supply of materials and installation of Gazebos of approved make and design and as per instructions of Engineer-in-charge.
604Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
605Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
606Chain Link Fencing
607Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
608Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
609Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
6101:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
611Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
612Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
613Concrete of M25 grade with minimum cement content of 330 kg /cum
614Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
615Concrete of M25 grade with minimum cement content of 330 kg /cum
616Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
617Thermo-Mechanically Treated bars of grade Fe-500D or more.
618Centering and shuttering including strutting, propping etc. and removal of form for
619Foundations, footings, bases of columns, etc. for mass concrete
620Columns, Pillars, Piers, Abutments, Posts and Struts
621Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
622Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
623Cement Plaster in (Coarse Sand)
62412 mm cement plaster :1:4 (1 cement : 4 coarse sand)
625Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
626Finishing walls with textured exterior paint of required shade :
627New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
628Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
629PHE Works
630Drainage System Works
631Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
632Pipes, cables etc, not exceeding 80 mm dia.
633Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
634Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
635Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
636Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
637100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
638Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
639150 mm dia. R.C.C. pipe
640250 mm dia. R.C.C. pipe
641Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
642Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
643Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
644Extra for depth for manholes
645Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
646Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
647Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
648With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
649Water Supply Works
650Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
65115 mm nominal dia Pipes
65220 mm nominal dia Pipes
65325 mm nominal dia Pipes
654Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
65515 mm nominal dia Pipes
65620 mm nominal dia Pipes
65725 mm nominal dia Pipes
658Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
65915 mm dia nominal bore
66020 mm dia nominal bore
66125 mm dia nominal bore
66280 mm dia nominal bore
663Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
66425 to 40 mm nominal bore
665Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
666Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
66720 mm nominal bore
66825 mm nominal bore
66980 mm nominal bore
670Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
67115 mm nominal bore
67220 mm nominal bore
67325 mm nominal bore
674Providing and fixing gun metal non- return valve of approved quality (screwed end) :
67525 mm nominal bore Horizontal
67680 mm nominal bore Horizontal
677Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
67825 mm nominal bore
679Providing and fixing uplasticised PVC connection pipe with brass unions :
68030 cm length, 15 mm nominal bore
681Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
682With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
683Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
684Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
68515 mm nominal bore
686Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
68715 mm nominal bore
688Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
68915 mm nominal bore
690Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
69180 mm nominal bore
692Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
693Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
694Sanitary Works
695Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
696W.C. pan with ISI marked white solid plastic seat and lid
697Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
698White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
699Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
700Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
701Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
70232 mm dia
703Providing and fixing 100 mm sand cast Iron grating for gully trap.
704Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
705Rectangular shape 1500x450 mm
706Providing and fixing toilet paper holder :
707C.P. brass
708100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
70975 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
710Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
711For 100 mm dia pipe
712For 75 mm dia pipe
713Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
714For 100 mm dia, Sand cast iron S&S as per IS – 3989
715For 75 mm dia, Sand cast iron S&S as per IS - 3989
716Providing and fixing bend of required degree .
717100mm dia, Sand cast iron S&S as per IS - 3989
718For 75 mm dia, Sand cast iron S&S as per IS - 3989
719Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
720100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
721100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
722Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
723Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
724ROAD LIGHTNING
725Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
726Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
727PANCHAYAT BHAWAN
728Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
729Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
730Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
731Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
732Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
7332x2.5 sq. mm + 1x2.5 sq. mm earth wire
7342x4 sq. mm + 1x4 sq. mm earth wire
735Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
7364x4 Sqmm +2x4 sqmm earth wire
737Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
738Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7394C X 25 Sq.mm Aluminium cable
740Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
741Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
742Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
7431 or 2 Module (75 mm x 75 mm)
7443 Module (100 mm x 75 mm)
7456 Module (200 mm x 75 mm)
74612 Module( 200 mm x 150mm)
747Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
748Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
749Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
750Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
751Bell push
752Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
7539- 10 watt
754Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
7551200mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
756Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
7576 way, Double door
758Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
7596 way (4 + 18), Double door
760Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
761Single pole
762Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
76363 Amp
764Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
765Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
766Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
767SCHOOL RENOVATION
768Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
769Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
770Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
771Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
772Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
7732x2.5 sq. mm + 1x2.5 sq. mm earth wire
7742x4 sq. mm + 1x4 sq. mm earth wire
775Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
7764x4 Sqmm +2x4 sqmm earth wire
777Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
778Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7794C X 25 Sq.mm Aluminium cable
780Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
781Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
782Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
7831 or 2 Module (75 mm x 75 mm)
7843 Module (100 mm x 75 mm)
7856 Module (200 mm x 75 mm)
78612 Module( 200 mm x 150mm)
787Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
788Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
789Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
790Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
791Bell push
792Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
7939- 10 watt
794Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
7951200mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
796Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
7976 way, Double door
798Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
7996 way (4 + 18), Double door
800Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
801Single pole
802Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
80363 Amp
804Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
805Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
806Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
807OPEN AIR THEATER
808Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
809Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
810Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
81140Watt, Color Temp 3000-5700k as required
812Supply,Installation, Testing, Commissioning of 12W LED Garden spike light fixture, well-designedmodern and rugged Garden Spike is a great addition to highlight your garden spaces. COB integratedlighting keeps the product high on light dispersion and efficiency. Key features are 80% energy savings,outdoor ambient lighting , protection against dust & jet of water from any direction, IP65 fixture ideal foroutdoor & wet areas, housing made with aluminium with black finish, LED integrated, IP65 protection,system wattage: 12W at system lumens of 675lm, CCT: 3000K, product dimension: 131mm x 89mm x243mm (±10%), Similar to Signify or Philip Cat. Ref no: Spike light 12W (Model no: 800139) orEquivalent as per meeting Tender Specs.
813Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
814Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
815Supply,Installation, Testing, Commissioning of 5W surface mounted LED Step light fixture, The neatly designed modern and minimal step light melds into the background settings and provides just the right ambient illumination to create an interesting setting. Key features are: LED light with beautiful light pattern, Highlight the outdoors, Endurance meets contemporary style, Clean lines, sleek design, warm white light, Robust finish, Long life LED source, housing made with aluminium & Anthracite grey finish, LED integrated, IP44, system wattage of 5W with system lumen of 165lm @ 3000K, product dimension of (L x W x H): 201mm x 91mm x 35mm, Similar to Signify or Philip Cat. Ref no: 31436 or Equivalent as per meeting Tender Specs.
816COMMUNITY AREA DEVELOPMENT
817Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
818Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
819Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
820Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
821Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
8222x2.5 sq. mm + 1x2.5 sq. mm earth wire
8232x4 sq. mm + 1x4 sq. mm earth wire
8242x10 sq. mm + 1x6 sq. mm earth wire
8252x16 sq. mm + 1x6 sq. mm earth wire
826Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
8274x4 Sqmm +2x4 sqmm earth wire
828Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
829Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
8304C X 25 Sq.mm Aluminium cable
831Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
832Upto 35 sq. mm
833Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
834Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
8351 or 2 Module (75 mm x 75 mm)
8363 Module (100 mm x 75 mm)
8376 Module (200 mm x 75 mm)
83812 Module( 200 mm x 150mm)
839Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
840Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
841Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
842Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
843Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
8449- 10 watt
845Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
8466 way, Double door
847Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8486 way (4 + 18), Double door
849Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required.
850For 6 way, Double door SPN MCBDB
851Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
852Single pole
853Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
85463 Amp
855Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
856Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
857Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
858Providing & Fixing of Double ball Bearing copper wounded capacitor start single phase metallic blade fresh air fan in existing opening including cost of hardware flexible 3 core copper making connection testing etc.300mm Sweep
859Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
860Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
86140Watt, Color Temp 3000-5700k as required
862Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
863SOLAR PV PLANT
864Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
865Kangsali Village
866Pathway Upgradation
867Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
868Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
869Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
870Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
871Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
872Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
873Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
874Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
875Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
876Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
877For Grading I Material
878Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
879PCC Grade M15
880Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
881Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
882PCC M15 for Kerb base
883PCC M20 for Kerb (Cast in Situ)
884Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
885Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
886Plaster & Painting on Village Walls
887Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
888Cement Plaster in (Coarse Sand)
88920 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
890New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
891Renovation of Schools & MDM Center
892Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge.
893Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
894Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
895Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
896In cement mortar
897Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
898Of area 3 sq. metres and below
899Of area beyond 3 sq. Metres
900Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
901Concrete of M25 grade with minimum cement content of 330 kg /cum
902Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
903Thermo-Mechanically Treated bars of grade Fe-500D or more.
904Centering and shuttering including strutting, propping etc. and removal of form for
905Suspended floors, roofs, landings, balconies and access platform
906Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
90712 mm cement plaster of mix ( in coarse sand)
9081:4 (1 cement: 4 coarse sand)
909Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
910With cement mortar 1:4 (1cement: 4 coarse sand)
911Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
912Door chowkhats
913Window chowkhats
914Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
915For thickness of tiles 10 mm to 25 mm
916Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
917Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
918Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
919Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
920Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
921Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
922Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
923Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet Complete.
924Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
925110 mm diameter
926Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
927Coupler, 110 mm
928Single tee with door, 1100mm x 110 mm x 110 mm
929Bend 87.5°, 110 mm bend
930Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.
931110 mm diameter
932Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
933Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
934Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
935Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
936Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
937Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
938Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
939For Grading I Material
940Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
941PCC Grade M15
942Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
943Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
944PCC M15 for Kerb base
945PCC M20 for Kerb (Cast in Situ)
946Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
947W.C. pan with ISI marked white solid plastic seat and lid
948Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
949Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
950Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
951White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
952Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
953Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
95410 litre (full flush) capacity-white
955Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
956Flexible pipe, 32 mm dia
957Providing and fixing 100 mm sand cast Iron grating for gully trap.
958Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
959Rectangular shape 1500x450 mm
960Providing and fixing toilet paper holder :
961C.P. brass
962100 mm dia Sand cast iron S&S pipe as per IS: 1729
96375 mm dia Sand cast iron S&S pipe as per IS: 1729
964Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
96575 mm dia pipe
966100 mm dia pipe
967Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
968For 100 mm dia pipe
969For 75 mm dia pipe
970Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
971100 mm diameter pipe
97275 mm diameter pipe
973Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
974Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
975Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
976450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
977Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge for Concealed work, including cutting chases and making good the walls etc.
97815 mm nominal outer dia Pipes
97920 mm nominal outer dia Pipes
98032 mm nominal outer dia Pipes
981Providing and fixing brass bib cock of approved quality :
98215 mm nominal bore
98320 mm nominal bore
984Providing and fixing brass stop cock of approved quality :
98515 mm nominal bore
98620 mm nominal bore
987Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
98825 mm nominal bore
98932 mm nominal bore
990Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
99120 mm nominal bore
99225 mm nominal bore
993Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately
994Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
995Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
996Construction of Vat Chamber as per drawing & all required civil works and as per direction of Engineer-in-charge.
997Supply and Installation of WATER ATM of approbed make and design and as per the direction of the Engineer-in-charge.
998Open Air Theatre
999Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
1000Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
1001Ordinary soil, up to 3m depth
1002Ordinary rock (not requiring blasting) up to 3 m depth
1003Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
1004Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
1005Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1006Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1007Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
10081:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1009Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1010Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
1011Cement Plaster in (Coarse Sand)
101212 mm cement plaster :1:6 (1 cement : 6 Fine sand)
1013Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
1014Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
1015Random Rubble Masonry in 1:3 cement mortar
1016Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
1017Random Rubble Masonry in 1:3 cement mortar
1018Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
1019Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
1020Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
1021Providing and laying Lime stone river finish flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
1022Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
1023Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
1024Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1025For Grading I Material
1026Providing and laying 75 x 75 x 18 mm thick Phylitte Tumbled stone for flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
1027Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever Required.
10280.80 mm thick with zinc coating not less than 275 gm/m?
1029Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
10300.80 mm thick with zinc coating not less than 275 gm/m?
1031Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1032Community Area Development & Other Misc Utilities
1033Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1034Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
1035Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
1036Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1037Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
1038Construction of Recharge Pits as per drawing and instruction of Engineer-in-charge.
1039Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
1040Chain Link Fencing
1041Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
1042Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
1043Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
10441:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1045Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
1046Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
1047Concrete of M25 grade with minimum cement content of 330 kg /cum
1048Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1049Concrete of M25 grade with minimum cement content of 330 kg /cum
1050Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1051Thermo-Mechanically Treated bars of grade Fe-500D or more.
1052Centering and shuttering including strutting, propping etc. and removal of form for
1053Foundations, footings, bases of columns, etc. for mass concrete
1054Columns, Pillars, Piers, Abutments, Posts and Struts
1055Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1056Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1057Cement Plaster in (Coarse Sand)
105812 mm cement plaster :1:4 (1 cement : 4 coarse sand)
1059Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
1060Finishing walls with textured exterior paint of required shade :
1061New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
1062Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
1063PHE Works
1064Drainage System Works
1065Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
1066Pipes, cables etc, not exceeding 80 mm dia.
1067Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
1068Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1069Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
1070Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1071100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1072Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1073150 mm dia. R.C.C. pipe
1074250 mm dia. R.C.C. pipe
1075Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
1076Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1077Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1078Extra for depth for manholes
1079Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1080Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1081Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
1082With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1083Water Supply Works
1084Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
108515 mm nominal dia Pipes
108620 mm nominal dia Pipes
108725 mm nominal dia Pipes
1088Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
108915 mm nominal dia Pipes
109020 mm nominal dia Pipes
109125 mm nominal dia Pipes
1092Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
109315 mm dia nominal bore
109420 mm dia nominal bore
109525 mm dia nominal bore
109680 mm dia nominal bore
1097Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
109825 to 40 mm nominal bore
1099Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
1100Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
110120 mm nominal bore
110225 mm nominal bore
110380 mm nominal bore
1104Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
110515 mm nominal bore
110620 mm nominal bore
110725 mm nominal bore
1108Providing and fixing gun metal non- return valve of approved quality (screwed end) :
110925 mm nominal bore Horizontal
111080 mm nominal bore Horizontal
1111Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
111225 mm nominal bore
1113Providing and fixing uplasticised PVC connection pipe with brass unions :
111430 cm length, 15 mm nominal bore
1115Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1116With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1117Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1118Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
111915 mm nominal bore
1120Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
112115 mm nominal bore
1122Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
112315 mm nominal bore
1124Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
112580 mm nominal bore
1126Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
1127Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
1128Sanitary Works
1129Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
1130W.C. pan with ISI marked white solid plastic seat and lid
1131Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1132White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1133Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
1134Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
1135Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
113632 mm dia
1137Providing and fixing 100 mm sand cast Iron grating for gully trap.
1138Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
1139Rectangular shape 1500x450 mm
1140Providing and fixing toilet paper holder :
1141C.P. brass
1142100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
114375 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
1144Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
1145For 100 mm dia pipe
1146For 75 mm dia pipe
1147Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
1148For 100 mm dia, Sand cast iron S&S as per IS – 3989
1149For 75 mm dia, Sand cast iron S&S as per IS - 3989
1150Providing and fixing bend of required degree .
1151100mm dia, Sand cast iron S&S as per IS - 3989
1152For 75 mm dia, Sand cast iron S&S as per IS - 3989
1153Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
1154100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
1155100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
1156Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1157Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
1158ROAD LIGHTNING
1159Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1160Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
1161SCHOOL RENOVATION
1162Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1163Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1164Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1165Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
1166Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
11672x2.5 sq. mm + 1x2.5 sq. mm earth wire
11682x4 sq. mm + 1x4 sq. mm earth wire
1169Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
11704x4 Sqmm +2x4 sqmm earth wire
1171Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1172Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
11734C X 25 Sq.mm Aluminium cable
1174Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1175Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1176Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
11771 or 2 Module (75 mm x 75 mm)
11783 Module (100 mm x 75 mm)
11796 Module (200 mm x 75 mm)
118012 Module( 200 mm x 150mm)
1181Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1182Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1183Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1184Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1185Bell push
1186Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
11879- 10 watt
1188Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
11891050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1190Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
11916 way, Double door
1192Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
11936 way (4 + 18), Double door
1194Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
1195Single pole
1196Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
119763 Amp
1198Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1199Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1200Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1201OPEN AIR THEATER
1202Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1203Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
1204Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
120540Watt, Color Temp 3000-5700k as required
1206Supply,Installation, Testing, Commissioning of 12W LED Garden spike light fixture, well-designedmodern and rugged Garden Spike is a great addition to highlight your garden spaces. COB integratedlighting keeps the product high on light dispersion and efficiency. Key features are 80% energy savings,outdoor ambient lighting , protection against dust & jet of water from any direction, IP65 fixture ideal foroutdoor & wet areas, housing made with aluminium with black finish, LED integrated, IP65 protection,system wattage: 12W at system lumens of 675lm, CCT: 3000K, product dimension: 131mm x 89mm x243mm (±10%), Similar to Signify or Philip Cat. Ref no: Spike light 12W (Model no: 800139) orEquivalent as per meeting Tender Specs.
1207Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1208Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1209Supply,Installation, Testing, Commissioning of 5W surface mounted LED Step light fixture, The neatly designed modern and minimal step light melds into the background settings and provides just the right ambient illumination to create an interesting setting. Key features are: LED light with beautiful light pattern, Highlight the outdoors, Endurance meets contemporary style, Clean lines, sleek design, warm white light, Robust finish, Long life LED source, housing made with aluminium & Anthracite grey finish, LED integrated, IP44, system wattage of 5W with system lumen of 165lm @ 3000K, product dimension of (L x W x H): 201mm x 91mm x 35mm, Similar to Signify or Philip Cat. Ref no: 31436 or Equivalent as per meeting Tender Specs.
1210SOLAR PV PLANT
1211Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
1212Dharkot Village
1213Parking Area
1214Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
1215Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1216For Grading I Material
1217Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1218PCC Grade M15
1219Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
1220Pathway Upgradation
1221Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
1222Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
1223Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
1224Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
1225Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
1226Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
1227Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
1228Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
1229Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
1230Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1231For Grading I Material
1232Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1233PCC Grade M15
1234Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
1235Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
1236PCC M15 for Kerb base
1237PCC M20 for Kerb (Cast in Situ)
1238Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
1239Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
1240Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
1241Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 1.2-1.5 kg/sqm using mechanical means as per Technical Specification Clause 502.
1242Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.
1243Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects.
1244Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects.
1245Plaster & Painting on Village Walls
1246Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
1247Cement Plaster in (Coarse Sand)
124820 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
1249New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
1250Renovation of Panchayat Bhavan
1251Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge.
1252Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
1253Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1254Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
1255In cement mortar
1256Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
1257Of area 3 sq. metres and below
1258Of area beyond 3 sq. Metres
1259Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1260Concrete of M25 grade with minimum cement content of 330 kg /cum
1261Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1262Thermo-Mechanically Treated bars of grade Fe-500D or more.
1263Centering and shuttering including strutting, propping etc. and removal of form for
1264Suspended floors, roofs, landings, balconies and access platform
1265Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
126612 mm cement plaster of mix ( in coarse sand)
12671:4 (1 cement: 4 coarse sand)
1268Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
1269With cement mortar 1:4 (1cement: 4 coarse sand)
1270Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
1271Door chowkhats
1272Window chowkhats
1273Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
1274For thickness of tiles 10 mm to 25 mm
1275Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
1276Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1277Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
1278Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1279Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
1280Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
1281Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
1282Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet Complete.
1283Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
1284110 mm diameter
1285Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1286Coupler, 110 mm
1287Single tee with door, 1100mm x 110 mm x 110 mm
1288Bend 87.5°, 110 mm bend
1289Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.
1290110 mm diameter
1291Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
1292Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1293School Repair & Rehabilitation
1294Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
1295Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
1296Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
1297Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
1298Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1299For Grading I Material
1300Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1301PCC Grade M15
1302Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
1303Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
1304PCC M15 for Kerb base
1305PCC M20 for Kerb (Cast in Situ)
1306Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
1307With cement mortar 1:4 (1cement: 4 coarse sand)
1308Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1309Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1310Concrete of M25 grade with minimum cement content of 330 kg /cum
1311Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1312Thermo-Mechanically Treated bars of grade Fe-500D or more.
1313Centering and shuttering including strutting, propping etc. and removal of form for
1314Suspended floors, roofs, landings, balconies and access platform
1315Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
1316For fixed portion with Powder coated aluminium (minimum thickness of powder coating 50 micron)
1317For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required .
1318Powder coated aluminium (minimum thickness of powder coating 50 micron)
1319Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
1320With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
1321Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm cic, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
132212.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks)
1323Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever Required.
13240.80 mm thick with zinc coating not less than 275 gm/m?
1325Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
13260.80 mm thick with zinc coating not less than 275 gm/m?
1327Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1328Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
1329Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1330Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
1331Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1332Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
1333Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
1334W.C. pan with ISI marked white solid plastic seat and lid
1335Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
1336Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
1337Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1338White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1339Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
1340Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
134110 litre (full flush) capacity-white
1342Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
1343Flexible pipe, 32 mm dia
1344Providing and fixing 100 mm sand cast Iron grating for gully trap.
1345Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
1346Rectangular shape 1500x450 mm
1347Providing and fixing toilet paper holder :
1348C.P. brass
1349100 mm dia Sand cast iron S&S pipe as per IS: 1729
135075 mm dia Sand cast iron S&S pipe as per IS: 1729
1351Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
135275 mm dia pipe
1353100 mm dia pipe
1354Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
1355For 100 mm dia pipe
1356For 75 mm dia pipe
1357Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
1358100 mm diameter pipe
135975 mm diameter pipe
1360Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
1361Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1362Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
1363450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
1364Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge for Concealed work, including cutting chases and making good the walls etc.
136515 mm nominal outer dia Pipes
136620 mm nominal outer dia Pipes
136732 mm nominal outer dia Pipes
1368Providing and fixing brass bib cock of approved quality :
136915 mm nominal bore
137020 mm nominal bore
1371Providing and fixing brass stop cock of approved quality :
137215 mm nominal bore
137320 mm nominal bore
1374Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
137525 mm nominal bore
137632 mm nominal bore
1377Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
137820 mm nominal bore
137925 mm nominal bore
1380Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately
1381Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
1382Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1383Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1384Construction of Vat Chamber as per drawing & all required civil works and as per direction of Engineer-in-charge.
1385Supply and Installation of WATER ATM of approbed make and design and as per the direction of the Engineer-in-charge.
1386Smart Classroom
1387DLP Projector
1388Multimedia PC
1389Desktop Computer for Lab
1390Server
1391Furniture with workstation and chairs for Desktop Computer
1392Leased Line Connectivity 10 MBPS
1393Infrared Interactive Board 75 Inches with Green Board
1394Bio-Metric for classroom
1395CCTV Camera (IP Based) with NVR 8 & 16 Channel
1396Gigabit Fast Ethernet Switch 16 /24 Port)
1397Gigabit Fast Ethernet Switch 48 Port
1398UTP CAT 6 Cable (305 Mtr)
1399Information Outlet (I/O) Cat 6 with face plate
1400Patch Cord Cat 6 UTP (1 Mtr)
1401Patch Cord Cat 6 UTP (2 Mtr)
1402Patch Panel 24 port
14039U wall mount Network Rack for School
140427U wall mount Network Rack for School
1405Online UPS 10 KVA (60 Min Backup)
1406Air Conditioner 1.5 Ton with Installation
1407Display 55 Inch
1408All in One Printer
1409E – Content (Text Book basedEducational Software from 6th to 12th standard. E- Library etc.
1410Antivirus for Servers
1411Any other Equipment’s / Solutions if required for completion of the scope of work. (PC Cabinet / Rack), Computer Lab Electrical work & Lab Partation
1412Open Air Theatre
1413Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
1414Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
1415Ordinary soil, up to 3m depth
1416Ordinary rock (not requiring blasting) up to 3 m depth
1417Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
1418Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
1419Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1420Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1421Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
14221:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1423Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1424Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
1425Cement Plaster in (Coarse Sand)
142612 mm cement plaster :1:6 (1 cement : 6 Fine sand)
1427Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
1428Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
1429Random Rubble Masonry in 1:3 cement mortar
1430Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
1431Random Rubble Masonry in 1:3 cement mortar
1432Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
1433Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
1434Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
1435Providing and laying Lime stone river finish flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
1436Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
1437Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
1438Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1439For Grading I Material
1440Providing and laying 75 x 75 x 18 mm thick Phylitte Tumbled stone for flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
1441Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever Required.
14420.80 mm thick with zinc coating not less than 275 gm/m?
1443Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
14440.80 mm thick with zinc coating not less than 275 gm/m?
1445Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1446Community Area Development & Other Misc Utilities
1447Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
1448Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
1449Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
1450Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m in ordinary rock.
1451Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1452Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
1453Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
1454Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :
1455Screened through sieve of I.S. designation 16 mm
1456Fine dressing of the ground.
1457Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
1458Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
1459Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408, using concrete mixer
1460PCC M15 for Kerb base
1461PCC M20 for Kerb (Cast in Situ)
1462Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
14631:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1464Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1465Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1466For Grading I Material
1467Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504
1468Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
1469Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
1470Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bag of size 20 cm as per direction of the Officer-in-charge.
1471Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
1472Supplying & Stacking of Selection No.1 grass turf at site fresh & free from weeds having proper roots, lush green including loading, unloading, carriage and all taxes paid etc. and as per direction of the officer-in-charge.
1473Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).
1474In rows 5 cm apart in both directions
1475Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for Separately)
1476Holes 1.2 m dia and 1.2 m deep
1477Holes 60 cm dia, and 60 cm deep
1478Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
1479Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water).
1480Trees plant
1481Shrubs Plant
1482Construction of View Point as per drawing and as per instruction of Engineer in charge inclusive of all civil works.
1483Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1484Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
1485Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
1486Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1487Supply of materials and installation of Gazebos of approved make and design and as per instructions of Engineer-in-charge.
1488Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
1489Construction of Recharge Pits as per drawing and instruction of Engineer-in-charge.
1490Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
1491Chain Link Fencing
1492Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
1493Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
1494Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
14951:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1496Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
1497Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
1498Concrete of M25 grade with minimum cement content of 330 kg /cum
1499Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1500Concrete of M25 grade with minimum cement content of 330 kg /cum
1501Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1502Thermo-Mechanically Treated bars of grade Fe-500D or more.
1503Centering and shuttering including strutting, propping etc. and removal of form for
1504Foundations, footings, bases of columns, etc. for mass concrete
1505Columns, Pillars, Piers, Abutments, Posts and Struts
1506Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1507Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1508Cement Plaster in (Coarse Sand)
150912 mm cement plaster :1:4 (1 cement : 4 coarse sand)
1510Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
1511Finishing walls with textured exterior paint of required shade :
1512New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
1513Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
1514PHE Works
1515Drainage System Works
1516Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
1517Pipes, cables etc, not exceeding 80 mm dia.
1518Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
1519Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1520Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
1521Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1522100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1523Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1524150 mm dia. R.C.C. pipe
1525250 mm dia. R.C.C. pipe
1526Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
1527Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1528Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1529Extra for depth for manholes
1530Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1531Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1532Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
1533With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1534Water Supply Works
1535Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
153615 mm nominal dia Pipes
153720 mm nominal dia Pipes
153825 mm nominal dia Pipes
1539Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
154015 mm nominal dia Pipes
154120 mm nominal dia Pipes
154225 mm nominal dia Pipes
1543Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
154415 mm dia nominal bore
154520 mm dia nominal bore
154625 mm dia nominal bore
154780 mm dia nominal bore
1548Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
154925 to 40 mm nominal bore
1550Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
1551Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
155220 mm nominal bore
155325 mm nominal bore
155480 mm nominal bore
1555Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
155615 mm nominal bore
155720 mm nominal bore
155825 mm nominal bore
1559Providing and fixing gun metal non- return valve of approved quality (screwed end) :
156025 mm nominal bore Horizontal
156180 mm nominal bore Horizontal
1562Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
156325 mm nominal bore
1564Providing and fixing uplasticised PVC connection pipe with brass unions :
156530 cm length, 15 mm nominal bore
1566Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1567With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1568Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1569Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
157015 mm nominal bore
1571Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
157215 mm nominal bore
1573Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
157415 mm nominal bore
1575Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
157680 mm nominal bore
1577Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
1578Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
1579Sanitary Works
1580Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
1581W.C. pan with ISI marked white solid plastic seat and lid
1582Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1583White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1584Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
1585Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
1586Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
158732 mm dia
1588Providing and fixing 100 mm sand cast Iron grating for gully trap.
1589Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
1590Rectangular shape 1500x450 mm
1591Providing and fixing toilet paper holder :
1592C.P. brass
1593100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
159475 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
1595Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
1596For 100 mm dia pipe
1597For 75 mm dia pipe
1598Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
1599For 100 mm dia, Sand cast iron S&S as per IS – 3989
1600For 75 mm dia, Sand cast iron S&S as per IS - 3989
1601Providing and fixing bend of required degree .
1602100mm dia, Sand cast iron S&S as per IS - 3989
1603For 75 mm dia, Sand cast iron S&S as per IS - 3989
1604Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
1605100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
1606100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
1607Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1608Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
1609Camping Area
1610Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
1611Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
1612Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
1613Providing and fixing 10 x 10 x 7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in pathways etc. laid over 50mm thick sand bed with joints 10mm wide filled with sand etc. complete as per direction of engineer-in-charge.
1614Providing concrete for plain/ reinforced concrete in Floors complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1615PCC Grade M15
1616PARKING LIGHTNING
1617Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1618Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4/5 Mtr.
1619Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1620Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1621ROAD LIGHTNING
1622Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1623Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
1624PANCHAYAT BHAWAN
1625Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1626Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1627Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1628Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
1629Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
16302x2.5 sq. mm + 1x2.5 sq. mm earth wire
16312x4 sq. mm + 1x4 sq. mm earth wire
1632Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
16334x4 Sqmm +2x4 sqmm earth wire
1634Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1635Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
16364C X 25 Sq.mm Aluminium cable
1637Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1638Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1639Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
16401 or 2 Module (75 mm x 75 mm)
16413 Module (100 mm x 75 mm)
16426 Module (200 mm x 75 mm)
164312 Module( 200 mm x 150mm)
1644Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1645Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1646Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1647Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1648Bell push
1649Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
16509- 10 watt
1651Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
16521050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1653Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
16546 way, Double door
1655Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
16566 way (4 + 18), Double door
1657Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
1658Single pole
1659Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
166063 Amp
1661Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1662Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1663Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1664SCHOOL RENOVATION
1665Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1666Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1667Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1668Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
1669Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
16702x2.5 sq. mm + 1x2.5 sq. mm earth wire
16712x4 sq. mm + 1x4 sq. mm earth wire
1672Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
16734x4 Sqmm +2x4 sqmm earth wire
1674Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1675Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
16764C X 25 Sq.mm Aluminium cable
1677Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1678Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1679Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
16801 or 2 Module (75 mm x 75 mm)
16813 Module (100 mm x 75 mm)
16826 Module (200 mm x 75 mm)
168312 Module( 200 mm x 150mm)
1684Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1685Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1686Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1687Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1688Bell push
1689Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
16909- 10 watt
1691Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
16921050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1693Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
16946 way, Double door
1695Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
16966 way (4 + 18), Double door
1697Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
1698Single pole
1699Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
170063 Amp
1701Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1702Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1703Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1704OPEN AIR THEATER
1705Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1706Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
1707Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
170840Watt, Color Temp 3000-5700k as required
1709Supply,Installation, Testing, Commissioning of 12W LED Garden spike light fixture, well-designedmodern and rugged Garden Spike is a great addition to highlight your garden spaces. COB integratedlighting keeps the product high on light dispersion and efficiency. Key features are 80% energy savings,outdoor ambient lighting , protection against dust & jet of water from any direction, IP65 fixture ideal foroutdoor & wet areas, housing made with aluminium with black finish, LED integrated, IP65 protection,system wattage: 12W at system lumens of 675lm, CCT: 3000K, product dimension: 131mm x 89mm x243mm (±10%), Similar to Signify or Philip Cat. Ref no: Spike light 12W (Model no: 800139) orEquivalent as per meeting Tender Specs.
1710Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1711Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1712Supply,Installation, Testing, Commissioning of 5W surface mounted LED Step light fixture, The neatly designed modern and minimal step light melds into the background settings and provides just the right ambient illumination to create an interesting setting. Key features are: LED light with beautiful light pattern, Highlight the outdoors, Endurance meets contemporary style, Clean lines, sleek design, warm white light, Robust finish, Long life LED source, housing made with aluminium & Anthracite grey finish, LED integrated, IP44, system wattage of 5W with system lumen of 165lm @ 3000K, product dimension of (L x W x H): 201mm x 91mm x 35mm, Similar to Signify or Philip Cat. Ref no: 31436 or Equivalent as per meeting Tender Specs.
1713COMMUNITY AREA DEVELOPMENT
1714Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1715Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1716Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1717Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
1718Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
17192x2.5 sq. mm + 1x2.5 sq. mm earth wire
17202x4 sq. mm + 1x4 sq. mm earth wire
17212x10 sq. mm + 1x6 sq. mm earth wire
17222x16 sq. mm + 1x6 sq. mm earth wire
1723Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
17244x4 Sqmm +2x4 sqmm earth wire
1725Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1726Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
17274C X 25 Sq.mm Aluminium cable
1728Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
1729Upto 35 sq. mm
1730Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1731Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
17321 or 2 Module (75 mm x 75 mm)
17333 Module (100 mm x 75 mm)
17346 Module (200 mm x 75 mm)
173512 Module( 200 mm x 150mm)
1736Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1737Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1738Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1739Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1740Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
17419- 10 watt
1742Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
17436 way, Double door
1744Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
17456 way (4 + 18), Double door
1746Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required.
1747For 6 way, Double door SPN MCBDB
1748Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
1749Single pole
1750Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
175163 Amp
1752Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1753Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1754Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1755Providing & Fixing of Double ball Bearing copper wounded capacitor start single phase metallic blade fresh air fan in existing opening including cost of hardware flexible 3 core copper making connection testing etc.300mm Sweep
1756Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1757Supply integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
175840Watt, Color Temp 3000-5700k as required
1759Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294/5 Mtr.
1760SOLAR PV PLANT
1761Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
1762VIEW POINT
1763Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1764Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4/5 Mtr.
1765NATURE ZONE
1766Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1767Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5 Mtr.
1768Jalwal Gaon Talla
1769Pathway Upgradation
1770Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
1771Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
1772Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
1773Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
1774Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
1775Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
1776Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
1777Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
1778Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
1779Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
1780For Grading I Material
1781Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1782PCC Grade M15
1783Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
1784Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
1785PCC M15 for Kerb base
1786PCC M20 for Kerb (Cast in Situ)
1787Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
1788Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
1789Plaster & Painting on Village Walls
1790Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
1791Cement Plaster in (Coarse Sand)
179220 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
1793New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
1794Renovation of Panchayat Bhavan
1795Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge.
1796Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
1797Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1798Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
1799In cement mortar
1800Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
1801Of area 3 sq. metres and below
1802Of area beyond 3 sq. Metres
1803Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1804Concrete of M25 grade with minimum cement content of 330 kg /cum
1805Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1806Thermo-Mechanically Treated bars of grade Fe-500D or more.
1807Centering and shuttering including strutting, propping etc. and removal of form for
1808Suspended floors, roofs, landings, balconies and access platform
1809Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
181012 mm cement plaster of mix ( in coarse sand)
18111:4 (1 cement: 4 coarse sand)
1812Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
1813With cement mortar 1:4 (1cement: 4 coarse sand)
1814Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
1815Door chowkhats
1816Window chowkhats
1817Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
1818For thickness of tiles 10 mm to 25 mm
1819Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
1820Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1821Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
1822Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1823Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
1824Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
1825Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
1826Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet Complete.
1827Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
1828110 mm diameter
1829Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
1830Coupler, 110 mm
1831Single tee with door, 1100mm x 110 mm x 110 mm
1832Bend 87.5°, 110 mm bend
1833Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.
1834110 mm diameter
1835Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
1836Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1837Community Area Development & Other Misc Utilities
1838Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
1839Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
1840Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
1841Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1842Supply of materials and installation of Gazebos of approved make and design and as per instructions of Engineer-in-charge.
1843Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
1844Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
1845Chain Link Fencing
1846Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
1847Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
1848Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
18491:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1850Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
1851Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
1852Concrete of M25 grade with minimum cement content of 330 kg /cum
1853Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
1854Concrete of M25 grade with minimum cement content of 330 kg /cum
1855Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
1856Thermo-Mechanically Treated bars of grade Fe-500D or more.
1857Centering and shuttering including strutting, propping etc. and removal of form for
1858Foundations, footings, bases of columns, etc. for mass concrete
1859Columns, Pillars, Piers, Abutments, Posts and Struts
1860Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1861Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1862Cement Plaster in (Coarse Sand)
186312 mm cement plaster :1:4 (1 cement : 4 coarse sand)
1864Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
1865Finishing walls with textured exterior paint of required shade :
1866New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
1867Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
1868PHE Works
1869Drainage System Works
1870Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
1871Pipes, cables etc, not exceeding 80 mm dia.
1872Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
1873Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1874Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
1875Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1876100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1877Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1878150 mm dia. R.C.C. pipe
1879250 mm dia. R.C.C. pipe
1880Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
1881Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1882Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1883Extra for depth for manholes
1884Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1885Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
1886Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
1887With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1888Water Supply Works
1889Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
189015 mm nominal dia Pipes
189120 mm nominal dia Pipes
189225 mm nominal dia Pipes
1893Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
189415 mm nominal dia Pipes
189520 mm nominal dia Pipes
189625 mm nominal dia Pipes
1897Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
189815 mm dia nominal bore
189920 mm dia nominal bore
190025 mm dia nominal bore
190180 mm dia nominal bore
1902Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
190325 to 40 mm nominal bore
1904Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
1905Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
190620 mm nominal bore
190725 mm nominal bore
190880 mm nominal bore
1909Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
191015 mm nominal bore
191120 mm nominal bore
191225 mm nominal bore
1913Providing and fixing gun metal non- return valve of approved quality (screwed end) :
191425 mm nominal bore Horizontal
191580 mm nominal bore Horizontal
1916Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
191725 mm nominal bore
1918Providing and fixing uplasticised PVC connection pipe with brass unions :
191930 cm length, 15 mm nominal bore
1920Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1921With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1922Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1923Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
192415 mm nominal bore
1925Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
192615 mm nominal bore
1927Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
192815 mm nominal bore
1929Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
193080 mm nominal bore
1931Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
1932Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
1933Sanitary Works
1934Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
1935W.C. pan with ISI marked white solid plastic seat and lid
1936Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1937White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1938Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
1939Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
1940Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
194132 mm dia
1942Providing and fixing 100 mm sand cast Iron grating for gully trap.
1943Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
1944Rectangular shape 1500x450 mm
1945Providing and fixing toilet paper holder :
1946C.P. brass
1947100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
194875 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
1949Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
1950For 100 mm dia pipe
1951For 75 mm dia pipe
1952Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
1953For 100 mm dia, Sand cast iron S&S as per IS – 3989
1954For 75 mm dia, Sand cast iron S&S as per IS - 3989
1955Providing and fixing bend of required degree .
1956100mm dia, Sand cast iron S&S as per IS - 3989
1957For 75 mm dia, Sand cast iron S&S as per IS - 3989
1958Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
1959100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
1960100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
1961Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1962Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
1963ROAD LIGHTNING
1964Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
1965Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
1966PANCHAYAT BHAWAN
1967Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1968Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1969Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
1970Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
1971Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
19722x2.5 sq. mm + 1x2.5 sq. mm earth wire
19732x4 sq. mm + 1x4 sq. mm earth wire
1974Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
19754x4 Sqmm +2x4 sqmm earth wire
1976Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1977Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
19784C X 25 Sq.mm Aluminium cable
1979Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1980Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1981Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
19821 or 2 Module (75 mm x 75 mm)
19833 Module (100 mm x 75 mm)
19846 Module (200 mm x 75 mm)
198512 Module( 200 mm x 150mm)
1986Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1987Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1988Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1989Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1990Bell push
1991Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
19929- 10 watt
1993Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
19941050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1995Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
19966 way, Double door
1997Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
19986 way (4 + 18), Double door
1999Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2000Single pole
2001Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
200263 Amp
2003Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2004Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2005Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2006SOLAR PV PLANT
2007Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
2008VIEW POINT
2009Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
2010Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
2011Jalwal Gaon Malla
2012Pathway Upgradation
2013Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
2014Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914
2015Cutting of shrubs from the road way or with in R.O.W and disposal of shrubs to suitable locations as per technical specifications Clause 1914
2016Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
2017Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
2018Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
2019Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.
2020Excavation in Ordinary Rock with Dozer with lead upto 100 m Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
2021Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
2022Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
2023For Grading I Material
2024Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
2025PCC Grade M15
2026Providing and fixing 20x20x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
2027Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
2028PCC M15 for Kerb base
2029PCC M20 for Kerb (Cast in Situ)
2030Construction of CC Toe Wall of Height 450 mm at road edges with PCC base as per drawing and direction of Engineer-in-Charge
2031Construction of MS Handrail of approved design and applying primer & paint of approved colour and as per direction of Engineer-in-charge.
2032Plaster & Painting on Village Walls
2033Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
2034Cement Plaster in (Coarse Sand)
203520 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
2036Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
2037School Repair & Rehabilitation
2038Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By manual means in area of non-thorny jungle.
2039Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
2040Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
2041Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
2042Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
2043For Grading I Material
2044Providing concrete for plain/ reinforced concrete in pathways complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
2045PCC Grade M15
2046Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
2047Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
2048PCC M15 for Kerb base
2049PCC M20 for Kerb (Cast in Situ)
2050Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
2051With cement mortar 1:4 (1cement: 4 coarse sand)
2052Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
2053Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
2054Providing and laying matt finished vitrified tile of size 100x100x16 mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20 mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.
2055Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
2056For fixed portion with Powder coated aluminium (minimum thickness of powder coating 50 micron)
2057For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required .
2058Powder coated aluminium (minimum thickness of powder coating 50 micron)
2059Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
2060With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
2061Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm cic, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
206212.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks)
2063Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
2064Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
2065Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
2066Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
2067W.C. pan with ISI marked white solid plastic seat and lid
2068Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
2069Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
2070Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
2071White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2072Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
2073Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
207410 litre (full flush) capacity-white
2075Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
2076Flexible pipe, 32 mm dia
2077Providing and fixing 100 mm sand cast Iron grating for gully trap.
2078Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
2079Rectangular shape 1500x450 mm
2080Providing and fixing toilet paper holder :
2081C.P. brass
2082100 mm dia Sand cast iron S&S pipe as per IS: 1729
208375 mm dia Sand cast iron S&S pipe as per IS: 1729
2084Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
208575 mm dia pipe
2086100 mm dia pipe
2087Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
2088For 100 mm dia pipe
2089For 75 mm dia pipe
2090Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
2091100 mm diameter pipe
209275 mm diameter pipe
2093Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
2094Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
2095Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
2096450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
2097Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge for Concealed work, including cutting chases and making good the walls etc.
209815 mm nominal outer dia Pipes
209920 mm nominal outer dia Pipes
210032 mm nominal outer dia Pipes
2101Providing and fixing brass bib cock of approved quality :
210215 mm nominal bore
210320 mm nominal bore
2104Providing and fixing brass stop cock of approved quality :
210515 mm nominal bore
210620 mm nominal bore
2107Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
210825 mm nominal bore
210932 mm nominal bore
2110Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
211120 mm nominal bore
211225 mm nominal bore
2113Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately
2114Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
2115Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
2116Smart Classroom
2117DLP Projector
2118Multimedia PC
2119Desktop Computer for Lab
2120Server
2121Furniture with workstation and chairs for Desktop Computer
2122Leased Line Connectivity 10 MBPS
2123Infrared Interactive Board 75 Inches with Green Board
2124Bio-Metric for classroom
2125CCTV Camera (IP Based) with NVR 8 & 16 Channel
2126Gigabit Fast Ethernet Switch 16 /24 Port)
2127Gigabit Fast Ethernet Switch 48 Port
2128UTP CAT 6 Cable (305 Mtr)
2129Information Outlet (I/O) Cat 6 with face plate
2130Patch Cord Cat 6 UTP (1 Mtr)
2131Patch Cord Cat 6 UTP (2 Mtr)
2132Patch Panel 24 port
21339U wall mount Network Rack for School
213427U wall mount Network Rack for School
2135Online UPS 10 KVA (60 Min Backup)
2136Air Conditioner 1.5 Ton with Installation
2137Display 55 Inch
2138All in One Printer
2139E – Content (Text Book based Educational Software from 6th to 12th standard. E- Library etc.
2140Antivirus for Servers
2141Any other Equipment’s / Solutions if required for completion of the scope of work. (PC Cabinet / Rack), Computer Lab Electrical work & Lab Partation
2142Construction of Vat Chamber as per drawing & all required civil works and as per direction of Engineer-in-charge.
2143Supply and Installation of WATER ATM of approbed make and design and as per the direction of the Engineer-in-charge.
2144Community Area Development & Other Misc Utilities
2145Construction of Boundary Wall as per drawing & all required civil works and as per direction of Engineer-in-charge.
2146Construction of Toilet as per Design & Drawing including all civil, electrical and mechanical works and as per instruction of Engineer-in-charge.
2147Construction of Septic Tank as per Design & Drawing including all civil works and as per the instruction of Engineer in Charge.
2148Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
2149Supply of materials and installation of Dry and Wet Dustbins of approved make and design and as per instructions of Engineer-in-charge.
2150Supply of materials and installation of Benches of approved make and design and as per instructions of Engineer-in-charge.
2151Construction of Recharge Pits as per drawing and instruction of Engineer-in-charge.
2152Chain Link Fencing
2153Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge in all kinds of soil.
2154Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge in Ordinary Rock.
2155Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for all work up to plinth level :
21561:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2157Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
2158Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works up to Plinth Level.
2159Concrete of M25 grade with minimum cement content of 330 kg /cum
2160Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete for all works above plinth level upto floor V level.
2161Concrete of M25 grade with minimum cement content of 330 kg /cum
2162Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels.
2163Thermo-Mechanically Treated bars of grade Fe-500D or more.
2164Centering and shuttering including strutting, propping etc. and removal of form for
2165Foundations, footings, bases of columns, etc. for mass concrete
2166Columns, Pillars, Piers, Abutments, Posts and Struts
2167Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2168Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
2169Cement Plaster in (Coarse Sand)
217012 mm cement plaster :1:4 (1 cement : 4 coarse sand)
2171Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete. (On steel work)
2172Finishing walls with textured exterior paint of required shade :
2173New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
2174Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
2175PHE Works
2176Drainage System Works
2177Excavating trenches by Mechanical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for All kinds of soil
2178Pipes, cables etc, not exceeding 80 mm dia.
2179Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
2180Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
2181Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
2182Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
2183100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
2184Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
2185150 mm dia. R.C.C. pipe
2186250 mm dia. R.C.C. pipe
2187Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand). RCC top slab in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
2188Inside size 90cm X 80cm and 45cm deep including C.I. Cover with frame(light duty) 455X610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) , With common burnt clay F.P.S (non modular) bricks of class designation 7.5
2189Inside size 120X90cm and 90cm deep including C.I. cover with frame(heavy duty) 500mm internal diameter total weight of cover and frame to be not less than 116 kg (weight to cover 58 kg and weight of frame 58 kg), With common burnt clay F.P.S (non modular) bricks of class designation 7.5
2190Extra for depth for manholes
2191Size 90 X 80 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
2192Size 120 X 90 cm, With common burnt clay F.P.S (non modular) bricks of class designation 7.5
2193Making soakpit 2.5m Diameter 3.0 meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drainpipe of 100 mm diameter and 1.8 m long complete as per the standard design.
2194With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
2195Water Supply Works
2196Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
219715 mm nominal dia Pipes
219820 mm nominal dia Pipes
219925 mm nominal dia Pipes
2200Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
220115 mm nominal dia Pipes
220220 mm nominal dia Pipes
220325 mm nominal dia Pipes
2204Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
220515 mm dia nominal bore
220620 mm dia nominal bore
220725 mm dia nominal bore
220880 mm dia nominal bore
2209Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
221025 to 40 mm nominal bore
2211Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
2212Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
221320 mm nominal bore
221425 mm nominal bore
221580 mm nominal bore
2216Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
221715 mm nominal bore
221820 mm nominal bore
221925 mm nominal bore
2220Providing and fixing gun metal non- return valve of approved quality (screwed end) :
222125 mm nominal bore Horizontal
222280 mm nominal bore Horizontal
2223Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
222425 mm nominal bore
2225Providing and fixing uplasticised PVC connection pipe with brass unions :
222630 cm length, 15 mm nominal bore
2227Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
2228With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
2229Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
2230Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
223115 mm nominal bore
2232Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
223315 mm nominal bore
2234Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
223515 mm nominal bore
2236Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
223780 mm nominal bore
2238Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
2239Centrifugal Monoblock Pump set (Single Stage), 3.7 KW (5.0 HP)
2240Sanitary Works
2241Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
2242W.C. pan with ISI marked white solid plastic seat and lid
2243Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
2244White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2245Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
2246Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
2247Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe
224832 mm dia
2249Providing and fixing 100 mm sand cast Iron grating for gully trap.
2250Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
2251Rectangular shape 1500x450 mm
2252Providing and fixing toilet paper holder :
2253C.P. brass
2254100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
225575 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
2256Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
2257For 100 mm dia pipe
2258For 75 mm dia pipe
2259Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
2260For 100 mm dia, Sand cast iron S&S as per IS – 3989
2261For 75 mm dia, Sand cast iron S&S as per IS - 3989
2262Providing and fixing bend of required degree .
2263100mm dia, Sand cast iron S&S as per IS - 3989
2264For 75 mm dia, Sand cast iron S&S as per IS - 3989
2265Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
2266100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS - 3989
2267100 mm inlet and 75 mm outlet, Sand cast iron S&S as per IS - 3989
2268Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
2269Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
2270Sateswar Temple Rehabilitation
2271Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2272Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
2273Ordinary soil, up to 3m depth
2274Ordinary rock (not requiring blasting) up to 3 m depth
2275Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
2276Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
22771:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2278Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
2279Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
2280Cement Plaster in (Coarse Sand)
228112 mm cement plaster :1:4 (1 cement : 4 coarse sand)
2282Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
2283Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
2284Random Rubble Masonry in 1:3 cement mortar
2285Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
2286Random Rubble Masonry in 1:3 cement mortar
2287Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
2288Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
2289Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
2290Providing and laying matt finished vitrified tile of size 100x100x16 mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20 mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.
2291Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of Engineer-in-charge.
2292Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
2293Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
2294For fixed portion with Powder coated aluminium (minimum thickness of powder coating 50 micron)
2295Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
2296With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
2297Parking for Temple
2298Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: For all kinds of soil
2299Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
2300Ordinary soil, up to 3m depth
2301Ordinary rock (not requiring blasting) up to 3 m depth
2302Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth Level :
23031:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2304Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
2305Random Rubble Masonry in 1:3 cement mortar
2306Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
2307Random Rubble Masonry in 1:3 cement mortar
2308Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
2309Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material.
2310Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
2311Granular Sub-base with Well Graded Material (Table 400.1), By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
2312For Grading I Material
2313Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
2314Spice Production Center
2315Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2316Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
2317Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m in ordinary rock.
2318Carriage of Excavated Earth up to a lead of 5km
2319Carriage of Excavated Rock up to a lead of 5 km
2320Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
2321Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2322Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
23231:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2324Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
2325Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
2326Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
2327Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:
2328All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum
2329All works above plinth level upto floor V level, Concrete of M25 grade with minimum cement content of 330 kg /cum
2330Centering and shuttering including strutting, propping etc. and removal of form for :
2331Foundations, footings, bases of columns, etc. for mass concrete
2332Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
2333Suspended floors, roofs, landings, balconies and access platform
2334Lintels, beams, plinth beams, girders, bressummers and cantilevers
2335Columns, Pillars, Piers, Abutments, Posts and Struts
2336Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
2337Thermo-Mechanically Treated bars of grade Fe-500D or more
2338Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
2339Thermo-Mechanically Treated bars of grade Fe-500D or more.
2340Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
2341Cement mortar 1:4 (1 cement : 4 coarse sand)
2342Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
2343Cement mortar 1:4 (1 cement :4 coarse sand)
2344Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
2345Sal wood
2346Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
234735 mm thick shutters
2348Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
2349For fixed portion with Powder coated aluminium (minimum thickness of powder coating 50 micron)
2350For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required .
2351Powder coated aluminium (minimum thickness of powder coating 50 micron)
2352Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge
2353Pre-laminated particle board with decorative lamination on both sides
2354Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
2355With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
2356Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge
2357Extruded section profile size 48x40 mm
2358Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers et
2359Hot finished welded type tubes
2360Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
2361Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
2362Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
236320 mm cement plaster of mix :
23641:4 (1 cement: 4 fine sand)
236512 mm cement plaster of mix :
23661:4 (1 cement: 4 coarse sand)
2367Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
2368Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
2369New work (two or more coats) over and including water thinnable priming coat with cement primer
2370Finishing walls with Acrylic Smooth exterior paint of required shade :
2371New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
2372Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
23731.00 mm thick with zinc coating not less than 275 gm/m2
2374Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
2375Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
2376W.C. pan with ISI marked white solid plastic seat and lid
2377Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
2378Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
2379Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
2380White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2381Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
2382Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.
238310 litre (full flush) capacity-white
2384Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
2385Flexible pipe, 32 mm dia
2386Providing and fixing 100 mm sand cast Iron grating for gully trap.
2387Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
2388Rectangular shape 1500x450 mm
2389Providing and fixing toilet paper holder :
2390C.P. brass
2391Providing and fixing soil, waste and vent pipes :
2392100 mm dia Sand cast iron S&S pipe as per IS: 1729
239375 mm diameter Sand cast iron S&S pipe as per IS: 1729
2394Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
239575 mm dia pipe
2396100 mm dia pipe
2397Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
2398For 100 mm dia pipe
2399For 75 mm dia pipe
2400Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
2401100 mm diameter pipe
240275 mm diameter pipe
2403Providing and fixing PTMT Bottle Trap for Wash basin and sink.
2404Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
2405Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
2406Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
2407450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
2408Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge for Concealed work, including cutting chases and making good the walls etc.
240915 mm nominal outer dia Pipes
241020 mm nominal outer dia Pipes
241132 mm nominal outer dia Pipes
2412Providing and fixing brass bib cock of approved quality :
241315 mm nominal bore
241420 mm nominal bore
2415Providing and fixing brass stop cock of approved quality :
241615 mm nominal bore
241720 mm nominal bore
2418Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
241925 mm nominal bore
242032 mm nominal bore
2421Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
242220 mm nominal bore
242325 mm nominal bore
2424Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
2425Supplying, Installation, Testing & Commissioning of 2000kg Machine room less (MRL) goods lift withregenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amendedupto date, serving different floors in the lift shaft as perdetailed specifications enclosed and as under including all other equipment and accessories complete as required :-(i) Speed - 0.5 MPS(ii) Floors - 5(G+4)(iii) Travel - 17 metres(approx)(iv) Stops & opening : 5 stops and 5 openings(v) Controller: A.C. variable voltage & variable frequency(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.(x) The car flooring should be strong to take the rated load without any deformation or damage and antiskid as approved by engineer-in-charge.(xi) Type of doors:-(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (MoonRock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel inthe lift car.(xiii) Voice announcement system in the car to announce the position of the elevator in the hoist wayas the car passes or stops at floor served by theelevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control,Landing doors 2 hours Fire rated, Overloaddetection and protection, Overspeed Governer, DotMatrix LED D & P Indicators In Car & Landings,BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift cardoor, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVRand HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switchwith battery backup for fan and light fitting for1 hour, pit ladder.(xv) In case of failure of ARD or other electronic
24262000 kg
2427PARKING LIGHTNING
2428Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
2429Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4/5 Mtr.
2430Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2431Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2432ROAD LIGHTNING
2433Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
2434Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS2629.4 /5Mtr.
2435SCHOOL RENOVATION
2436Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2437Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2438Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2439Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
2440Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
24412x2.5 sq. mm + 1x2.5 sq. mm earth wire
24422x4 sq. mm + 1x4 sq. mm earth wire
2443Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
24444x4 Sqmm +2x4 sqmm earth wire
2445Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2446Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
24474C X 25 Sq.mm Aluminium cable
2448Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2449Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
2450Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
24511 or 2 Module (75 mm x 75 mm)
24523 Module (100 mm x 75 mm)
24536 Module (200 mm x 75 mm)
245412 Module( 200 mm x 150mm)
2455Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
2456Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2457Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
2458Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2459Bell push
2460Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
24619- 10 watt
2462Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
24631050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
2464Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
24656 way, Double door
2466Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
24676 way (4 + 18), Double door
2468Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2469Single pole
2470Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
247163 Amp
2472Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2473Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2474Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2475SOLAR PV PLANT
2476Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant including 5 years AMC conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required.a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.f) Lightning, surge voltage protection, earthing protection and grid islanding.g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. including 5 years AMC
2477SATTESWAR MAHADEV TEMPLE
2478Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2479Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2480Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2481Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
2482Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
24832x2.5 sq. mm + 1x2.5 sq. mm earth wire
24842x4 sq. mm + 1x4 sq. mm earth wire
24852x10 sq. mm + 1x6 sq. mm earth wire
24862x16 sq. mm + 1x6 sq. mm earth wire
2487Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
24884x4 Sqmm +2x4 sqmm earth wire
2489Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2490Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
24914C X 25 Sq.mm Aluminium cable
2492Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
2493Upto 35 sq. mm
2494Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
2495Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
24961 or 2 Module (75 mm x 75 mm)
24973 Module (100 mm x 75 mm)
24986 Module (200 mm x 75 mm)
249912 Module( 200 mm x 150mm)
2500Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
2501Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2502Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
2503Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2504Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
25059- 10 watt
250614- 15 watt
2507Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
250836 Watt
2509Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
25106 way, Double door
2511Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
25126 way (4 + 18), Double door
2513Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required.
2514For 6 way, Double door SPN MCBDB
2515Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2516Single pole
2517Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
251863 Amp
2519Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2520Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2521Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2522Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
25231050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
2524Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2525Providing & Fixing of Double ball Bearing copper wounded capacitor start single phase metallic blade fresh air fan in existing opening including cost of hardware flexible 3 core copper making connection testing etc.300mm Sweep
2526Supply,Installation, Testing, Commissioning of 5W surface mounted LED Step light fixture, The neatly designed modern and minimal step light melds into the background settings and provides just the right ambient illumination to create an interesting setting. Key features are: LED light with beautiful light pattern, Highlight the outdoors, Endurance meets contemporary style, Clean lines, sleek design, warm white light, Robust finish, Long life LED source, housing made with aluminium & Anthracite grey finish, LED integrated, IP44, system wattage of 5W with system lumen of 165lm @ 3000K, product dimension of (L x W x H): 201mm x 91mm x 35mm, Similar to Signify or Philip Cat. Ref no: 31436 or Equivalent as per meeting Tender Specs.
2527Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
2528Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294 /5Mtr.
2529SPICE PRODUCTION CENTRE
2530Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2531Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2532Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2533Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
2534Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
25352x2.5 sq. mm + 1x2.5 sq. mm earth wire
25362x4 sq. mm + 1x4 sq. mm earth wire
25372x10 sq. mm + 1x6 sq. mm earth wire
25382x16 sq. mm + 1x6 sq. mm earth wire
2539Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
25404x4 Sqmm +2x4 sqmm earth wire
2541Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2542Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
25434C X 25 Sq.mm Aluminium cable
2544above 185 sqmm and upto 400 sqmm
2545Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
2546Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
2547Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
2548Upto 35 sq. mm
2549Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
25503½ X 25 sq. mm (28mm)
2551Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
2552Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
2553100 mm dia
2554Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2555Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
2556Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
25571 or 2 Module (75 mm x 75 mm)
25583 Module (100 mm x 75 mm)
25596 Module (200 mm x 75 mm)
256012 Module( 200 mm x 150mm)
2561Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
2562Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2563Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
2564Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
2565Telephone/Data Socket Outlet
2566TV antena Socket Outlet
2567Bell push
2568Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
25691 Pair
25702 Pair
2571Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2572Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
25739- 10 watt
257414- 15 watt
2575Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
257636 Watt
2577Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
25781050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
2579Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
25806 way, Double door
2581Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
25826 way (4 + 18), Double door
25838 way (4 + 24), Double door
2584Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required.
2585For 6 way, Double door SPN MCBDB
2586Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2587Single pole
2588Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
258940 Amp
2590Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
259140 Amp
259263 Amp
2593Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2594Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel LevelC) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH,PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
259550 KVA
2596Solar Street Light All in One Supply Installation, testing and commissioning of IP65/IK09, 30 Watt Smart integrated Solar Street Light (LED based) mono perk consist of white LED luminaire ( LED + Driver) and including battery Li-FEPo 4 , necessary control electronics, interconnecting wires / cables, module mounting structures, according to standard EN 60529 and EN 62262 ,complience with standard IEC 68-2-6 ,intelligent LED Street Luminaire should be made of Heavy-duty die-cast aluminum (EN AC-46100) and for extremely corrosive environments, surface treatment should be Anti-UV thermosetting polyester / 80 micron epoxy primer + Anti-UV thermosetting polyester.Available in all TYPEll(T201) TYPElll(T301) TYPElV(T401) V(T501) distrubution type ,30W Min efficacy to 154 lm/W,delivered lumens min 22100lm for streetlight application with Dimmable driver and integrated SLC , including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.Luminaire and built in idriver must meet follow paramenters:MPPT charge Controller and PIR Sensor with Colour Temprature 6000-6500K-DriverEficiency:>86%~>93%;Maximum Current:AC0.22A(max)~AC2.5A(max)-High eficiency driver:PF>0.98,driver eficiency>92%.Autonomy-2 dyas with Diming Profile30 Watt (System lumen efficacy >120 lm/Watt)
2597Supply and erection of M.S galvanized Octagonal pole (as per BSEN 40-3-3: 2023/BSEN 10025/IS 2062/IS:875-Part-1 2015/for MS plate for base flange) of Following Length and dimension with base plate on Cement concrete foundation of M-20 grade 1:1.5.3) as per IS-456/IS-2911 with the Help of anchor bolts of 6.8(IS: 1367 P III).Octagonal MS Pole made of S-355JO grade Steel sheet folded length wise to obtained OCtagonal shape having longtitudal seam welded and hot diped galvanized internally and externally in accordance with IS26294 /5 Mtr.
2598Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2599Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2600Environmental Monitoring
2601Air Quality /Monitoring
2602Water Quality Monitoring
2603Noise Level Monitoring Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58086773
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-11-2026
Authority
Authority Name Uttarakhand Tourism Development Board
Work Description Tender for Village Infrastructure Upgradation And Facilities Development At Khola, Kangsali, Sandana, Dharkot, Mandan Negi
Basic Detail
Tender No SICRTD/OCB-N/CW-01 dated 16/10/2026
Bidding Type Tender
Location
City Tehri Garhwal
State Uttarakhand
Key Dates
Publish Date 16 Oct 2026
Submission Date 18 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 11800
EMD 1.10 Crore
Exemption Not Available
Document List
9856870f-7d2b-4e96-95e7-0a3b0bb571ae.html
AdditionalDocuments.pdf
BOQ_119405.xls
TechnicalbidvillageinfraCW01.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 33 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 33 days

Tender Documents

Download All (ZIP) ↓
html

9856870f-7d2b-4e96-95e7-0a3b0bb571ae.html

pdf

AdditionalDocuments.pdf

xls

BOQ_119405.xls

pdf

TechnicalbidvillageinfraCW01.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender