Project Description

Tender for Balance Civil Work At Directorate Office ( By Way Of Construction Of Directorate Sheep Husbandary Leh.

BOQ

Name of Work:- Balance Civil work at Directorate Office ( By way of Construction of Directorate Sheep Husbandary Leh.
Sl. No. Item Description
1Providing and fixing 12mm thick pre laminated flooring of approved brand as per the direction of engineer incharge,complete job AC-4 including carriage.
2Providing and fixing traditionally carved wood work (Shingstak) over doors andwindows including all accessories as per the direction of the Engineer in-charge,complete with; 2nd class kail wood
3Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622(thickness to be specified by the manufacturer ) of approved make in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shade complete.
4Providing and fixing 100mm pine wood planking, tongued and grooved , including fixing in exposed surface , including necessary screws and priming coat on exposed surface.
5Providing joist(karries) including hoisting, fixing in position and applying woodpreservative on unexposed surface etc. complete with : Sal wood
6Providing fixing thermal insulation of ceiling (under deck insulation) with ResinBonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick,wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats(50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for topmost ceiling of building.
7Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
8Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
9Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
112 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
124 X 16 sq. mm + 2 X 6 sq. mm earth wire
132 X 10 sq. mm + 1 X 6 sq. mm earth wire
14Supplying and drawing co axial TV cable RG - grade , 0.7mm solid copper conductor PE insulated, shieded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel/ PVC conduit as required
15Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as require 25 mm
1640 mm
17Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
18Supplying and fixing following modular Blanking plate on the existing modular plate & switch box including connection but excludig modular plate etc as required
19Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
2015/16 A switch
213 pin 5/6 A socket outlet
226 pin 15/16 A socket outlet
23Telephone socket outlet
24TV antenna socket outlet
25Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2 Module
263 Module
274 Module
286 Module
298 Module
30Providing , installation of exhaust fan in the existing opening , including making good the damage , connection, testing , commissioning etc as required Up to 450 mm sweep.
31Extra for fixing the louvers/ shutters complete with frame for a exhaustfan of all sizes.
32Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) 6 way (4 + 18), Double door
338 way , Double door
34Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. Single pole
35Triple pole
36Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioningetc. as required. 63 A
37Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side asrequired.
38Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
39Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty ,48\\" Sweep 5 Star (1200 mm)
40Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @50/60Hz & Power factor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W)
41Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per W, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W-20W (T8)
42Sypply Installation and commissioning of 3.5 core 95 Sq. Mm. Aluminium armoured cable Along with necessary accessories for clamping and routing.
43Supply, installing and fixing ISI markded street light decorative out door lighting pole ( 3 mtr upto 70 watt ) made up of mild steel dual arm with complete wiring from nearest source with required MCB, switch, socket all complete job. As per instruction of Engineer Incharge
44Supply and installation of electric convector heater of heavy voltage with two heat output settings 1400 watts x 2 =2800 watts, over heat protection, thermostatically controlled
45Supply, installation, testing and commissioning of Sub LT panel. cubicle type totally enclosed out doortype,wall mount type, dust, damp and vermin proof Main Distribution Board complete with busbars, LT. danger notice plate,, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB /MCB'smeters , complete as required.1 No.160 Amp TPN MCCB thermo magnitic of 25kA adjustable.1 set. Timedelay circuit through 4P 125 A contactor including low- high cut alongwith single phase and phase reverse protection 1set BUSBARS 4 pole 125A3 nos. RCCB 40- 63A TPN 300 mA6 no DP MCB c-curveR,Y,B LED phase indicating lamp with MCB protectionThe Contractor will have to submit his test certificates i.e (MV test 1.5KV for 1Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and freeservice. ( for ODU panel .)
46Design, Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow Super Multi Modular System R410a refrigerant suitable for 415±10%, 3 phase , 50 Hz AC power supply. The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : AIR COOLED VRF/ VRV OUTDOOR UNITSSupply, Installation, Testing and Commissioning Modular type outdoor units equipped with highly efficient inverter compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit having COP at AHRI conditions , 50% load to be more than 5.0 , & shall be suitable to operate within an ambient temperature range of 5 Deg C to 46 Deg C in cooling mode & -20 Deg C or higher to 25 Deg C in heating mode of following capacitite . ODU- 16 HP
47ODU- 12 HP
48INDOOR UnitsSupply, Installation, Testing and Commissioning of following wall mounted type units Air Conditioners with cordless/corded remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete , 220 volt, 1 phase, 50 Hz, power lead as per OEM . Hi wall Type Indoor units (0.75Tr )
49Hi wall Type Indoor units (1.0 Tr )
50Hi wall Type Indoor units (1.5Tr)
51Hi wall Type Indoor units (2.0Tr)
52Hi wall Type Indoor units (2.5Tr)
53Supplying, installing, testing and commissioning of Refnet Y Joints of all types with insulation.
54Design, Supply, Installation, Testing and Commissioning of piping, control and power connections with following items and requirements:A) interconnecting copper refrigerant pipe Gas/Liquid VRV Standard work duly insulated with elastomeric nitrile rubber for piping. The piping shall be supported with proper MS Supportings at regular distances, Joints shall be covered with nitrile rubber tape complete as required B) Drain Piping: Providing and fixing of PVC Rigid drain water piping with complete fittings 25 mm dia ID C) Communication Cabling: 2C x 1.5 Sq. mm shieldedCopper control cables in properPVC conduits/bends for connections to equipment etc. complete as required.D) Power connections with 3Cx2.5 core shielded Copper cablesE) Netrogen testing and VacuumizationE) Additional refrigerant Gas R410.F) MS steel foundation for Outdoor units
55Supply, installation, testing and commissioning of Sub LT panel. cubicle type totally enclosed out doortype,wall mount type, dust, damp and vermin proof Main Distribution Board complete with busbars, LT. danger notice plate,, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB /MCB's meters , complete as required.1 No.160 Amp TPN MCCB thermo magnitic of 25kA adjustable.1 set. Timedelay circuit through 4P 125 A contactor including low- high cut along with single phase and phase reverse protection 1set BUSBARS 4 pole 125A3 nos. RCCB 40- 63A TPN 300 mA6 no DP MCB c-curveR,Y,B LED phase indicating lamp with MCB protection. The Contractor will have to submit his test certificates i.e (MV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service. ( for ODU panel .)
56Supply , laying , fxing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 70 sqmm 3 1/2 corefrom main panel to VRV panel
57Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
58Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
59Structural steelworkriveted,boltedorweldedinbuiltupsections, trussesandframed work, including
60ProvidingcorrugatedG.S. sheetroofingincludingvertical /curvedsurfacefixedwithpolymercoatedJorLhooks,boltsandnuts8mmdiametrewithbitumenandG.I. limpetwashers orwithG.I. limpetwashers filledwithwhite lead,includingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheetscomplete(uptoanypitchinhorizontal/verticalorcurvedsurfaces),excludingthecostofpurlins,raftersandtrussesandincludingcuttingto size and shape wherever required.0.63 MM Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58082873
AUTHORITY Government Departments
TENDER VALUE 1.43 Crore
LAST DATE 20-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Balance Civil Work At Directorate Office ( By Way Of Construction Of Directorate Sheep Husbandary Leh.
Basic Detail
Tender No E Tender 88 of R and B Division Leh
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 16 Oct 2026
Submission Date 20 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 1.43 Crore
Tender Fee 1440
EMD 2.86 Lakhs
Exemption Not Available
Document List
39dc19f3-b82f-42b8-94ee-70d6b8064f40.html
BOQ_46613.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

39dc19f3-b82f-42b8-94ee-70d6b8064f40.html

xls

BOQ_46613.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender