Tender For Balance Civil Work At Directorate Office ( By Way Of Construction Of Directorate Sheep Husbandary Leh.
Tender Value
1.43 Crore
Estimated cost
Bid Submission
20 Oct 2026
1 days left
EMD
2.86 Lakhs
Bank guarantee accepted
Document Fee
1440
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Balance Civil Work At Directorate Office ( By Way Of Construction Of Directorate Sheep Husbandary Leh.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing 12mm thick pre laminated flooring of approved brand as per the direction of engineer incharge,complete job AC-4 including carriage. |
| 2 | Providing and fixing traditionally carved wood work (Shingstak) over doors andwindows including all accessories as per the direction of the Engineer in-charge,complete with; 2nd class kail wood |
| 3 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622(thickness to be specified by the manufacturer ) of approved make in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shade complete. |
| 4 | Providing and fixing 100mm pine wood planking, tongued and grooved , including fixing in exposed surface , including necessary screws and priming coat on exposed surface. |
| 5 | Providing joist(karries) including hoisting, fixing in position and applying woodpreservative on unexposed surface etc. complete with : Sal wood |
| 6 | Providing fixing thermal insulation of ceiling (under deck insulation) with ResinBonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick,wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats(50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for topmost ceiling of building. |
| 7 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 8 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 9 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 12 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 13 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 14 | Supplying and drawing co axial TV cable RG - grade , 0.7mm solid copper conductor PE insulated, shieded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel/ PVC conduit as required |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as require 25 mm |
| 16 | 40 mm |
| 17 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 18 | Supplying and fixing following modular Blanking plate on the existing modular plate & switch box including connection but excludig modular plate etc as required |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 20 | 15/16 A switch |
| 21 | 3 pin 5/6 A socket outlet |
| 22 | 6 pin 15/16 A socket outlet |
| 23 | Telephone socket outlet |
| 24 | TV antenna socket outlet |
| 25 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2 Module |
| 26 | 3 Module |
| 27 | 4 Module |
| 28 | 6 Module |
| 29 | 8 Module |
| 30 | Providing , installation of exhaust fan in the existing opening , including making good the damage , connection, testing , commissioning etc as required Up to 450 mm sweep. |
| 31 | Extra for fixing the louvers/ shutters complete with frame for a exhaustfan of all sizes. |
| 32 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 33 | 8 way , Double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. Single pole |
| 35 | Triple pole |
| 36 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioningetc. as required. 63 A |
| 37 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side asrequired. |
| 38 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 39 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty ,48\\" Sweep 5 Star (1200 mm) |
| 40 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @50/60Hz & Power factor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W) |
| 41 | Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per W, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W-20W (T8) |
| 42 | Sypply Installation and commissioning of 3.5 core 95 Sq. Mm. Aluminium armoured cable Along with necessary accessories for clamping and routing. |
| 43 | Supply, installing and fixing ISI markded street light decorative out door lighting pole ( 3 mtr upto 70 watt ) made up of mild steel dual arm with complete wiring from nearest source with required MCB, switch, socket all complete job. As per instruction of Engineer Incharge |
| 44 | Supply and installation of electric convector heater of heavy voltage with two heat output settings 1400 watts x 2 =2800 watts, over heat protection, thermostatically controlled |
| 45 | Supply, installation, testing and commissioning of Sub LT panel. cubicle type totally enclosed out doortype,wall mount type, dust, damp and vermin proof Main Distribution Board complete with busbars, LT. danger notice plate,, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB /MCB'smeters , complete as required.1 No.160 Amp TPN MCCB thermo magnitic of 25kA adjustable.1 set. Timedelay circuit through 4P 125 A contactor including low- high cut alongwith single phase and phase reverse protection 1set BUSBARS 4 pole 125A3 nos. RCCB 40- 63A TPN 300 mA6 no DP MCB c-curveR,Y,B LED phase indicating lamp with MCB protectionThe Contractor will have to submit his test certificates i.e (MV test 1.5KV for 1Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and freeservice. ( for ODU panel .) |
| 46 | Design, Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow Super Multi Modular System R410a refrigerant suitable for 415±10%, 3 phase , 50 Hz AC power supply. The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : AIR COOLED VRF/ VRV OUTDOOR UNITSSupply, Installation, Testing and Commissioning Modular type outdoor units equipped with highly efficient inverter compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit having COP at AHRI conditions , 50% load to be more than 5.0 , & shall be suitable to operate within an ambient temperature range of 5 Deg C to 46 Deg C in cooling mode & -20 Deg C or higher to 25 Deg C in heating mode of following capacitite . ODU- 16 HP |
| 47 | ODU- 12 HP |
| 48 | INDOOR UnitsSupply, Installation, Testing and Commissioning of following wall mounted type units Air Conditioners with cordless/corded remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete , 220 volt, 1 phase, 50 Hz, power lead as per OEM . Hi wall Type Indoor units (0.75Tr ) |
| 49 | Hi wall Type Indoor units (1.0 Tr ) |
| 50 | Hi wall Type Indoor units (1.5Tr) |
| 51 | Hi wall Type Indoor units (2.0Tr) |
| 52 | Hi wall Type Indoor units (2.5Tr) |
| 53 | Supplying, installing, testing and commissioning of Refnet Y Joints of all types with insulation. |
| 54 | Design, Supply, Installation, Testing and Commissioning of piping, control and power connections with following items and requirements:A) interconnecting copper refrigerant pipe Gas/Liquid VRV Standard work duly insulated with elastomeric nitrile rubber for piping. The piping shall be supported with proper MS Supportings at regular distances, Joints shall be covered with nitrile rubber tape complete as required B) Drain Piping: Providing and fixing of PVC Rigid drain water piping with complete fittings 25 mm dia ID C) Communication Cabling: 2C x 1.5 Sq. mm shieldedCopper control cables in properPVC conduits/bends for connections to equipment etc. complete as required.D) Power connections with 3Cx2.5 core shielded Copper cablesE) Netrogen testing and VacuumizationE) Additional refrigerant Gas R410.F) MS steel foundation for Outdoor units |
| 55 | Supply, installation, testing and commissioning of Sub LT panel. cubicle type totally enclosed out doortype,wall mount type, dust, damp and vermin proof Main Distribution Board complete with busbars, LT. danger notice plate,, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB /MCB's meters , complete as required.1 No.160 Amp TPN MCCB thermo magnitic of 25kA adjustable.1 set. Timedelay circuit through 4P 125 A contactor including low- high cut along with single phase and phase reverse protection 1set BUSBARS 4 pole 125A3 nos. RCCB 40- 63A TPN 300 mA6 no DP MCB c-curveR,Y,B LED phase indicating lamp with MCB protection. The Contractor will have to submit his test certificates i.e (MV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service. ( for ODU panel .) |
| 56 | Supply , laying , fxing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 70 sqmm 3 1/2 corefrom main panel to VRV panel |
| 57 | Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc. |
| 58 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required. |
| 59 | Structural steelworkriveted,boltedorweldedinbuiltupsections, trussesandframed work, including |
| 60 | ProvidingcorrugatedG.S. sheetroofingincludingvertical /curvedsurfacefixedwithpolymercoatedJorLhooks,boltsandnuts8mmdiametrewithbitumenandG.I. limpetwashers orwithG.I. limpetwashers filledwithwhite lead,includingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheetscomplete(uptoanypitchinhorizontal/verticalorcurvedsurfaces),excludingthecostofpurlins,raftersandtrussesandincludingcuttingto size and shape wherever required.0.63 MM Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender