Tender For Construction Of Office Building Of Assistant Labour Officer At Koida Block

Issued by Government Departments · Sundargarh, Odisha
Tender Value
1.94 Crore
Estimated cost
Bid Submission
02 Nov 2026
14 days left
EMD
1.94 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Office Building Of Assistant Labour Officer At Koida Block

BOQ

Name of Work:- Construction of Office building of Assistant Labour Officer at Koida Block
Sl. No. Item Description
1CIVIL WORK
2Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment) including cost of all materials, labour, T&P etc complete in all respect and as per direction of the Engineer-in-charge.
3Ground Floor
4Watchman Shed
5Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.
6Ground Floor
7Compound wall
8Watchman Shed
9Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
10Ground Floor
11Compound wall
12Watchman Shed
13Cement Concrete (1:3:6) using 40mm size hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C.
14Ground Floor
15Compound wall
16Watchman Shed
17Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.
18Ground Floor
19Compound wall
20Watchman Shed
21Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge
22Ground Floor
23Compound wall
24Watchman Shed
25Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
26Ground Floor
27First Floor
28Head Room
29Compound wall
30Watchman Shed
31Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
32Ground Floor
33First Floor
34Watchman Shed
35R.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement.
36Ground Floor
37Footing
38Column
39Plinth Beam
40Lintel
41Roof Beam
42Roof Slab
43Chajja
44StairCase
45Shelves
46First Floor
47Column
48Lintel
49Roof Beam
50Roof Slab
51Chajja
52StairCase
53Head Room
54Column
55Chajja
56Roof Slab
57Watchman Shed
58Footing
59Column
60Plinth Beam
61Lintel
62Roof Beam
63Roof Slab
64Chajja
65Shelves
66Compound wall
67Footing
68Column
69Plinth Beam
70Roof Beam
71Providing 25 mm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips using 2% water proofing cement compound (Make -sika/fosroc/Equivalent) on new work
72Ground Floor
73First Floor
74Head Room
75Watchman Shed
76Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect.
77Ground Floor
78First Floor
79Head Room
80Compound wall
81Watchman Shed
8212mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.
83Ground Floor
84First Floor
85Head Room
86Compound wall
87Watchman Shed
8816mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C.
89Ground Floor
90First Floor
91Head Room
92Watchman Shed
936 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment including watering, curing cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.
94Ground Floor
95First Floor
96Head Room
97Watchman Shed
98Supplying, fitting and fixing Vitrified tile in floors of approved make confirmating to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C.
99Ground Floor
100First Floor
101Watchman Shed
102Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.
103Ground Floor
104First Floor
105Watchman Shed
106Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge
107Ground floor
108First Floor
109Watchman Shed
110Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
111Ground Floor
112Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge
113Ground Floor
114First Floor
115Watchman Shed
116Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete.
117Ground Floor
118First Floor
119External Wall
120Internal Wall
121Head Room
122External Wall
123Internal Wall
124Watchman Shed
125Compound wall
126Wall Painting two coats with approved Plastic Emulsion Paint including all labour, materials etc. complete.
127Ground Floor
128First Floor
129Head Room
130Watchman Shed
131Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C.
132Ground Floor
133First Floor
134Head Room
135Watchman Shed
136Compound wall
137Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge
138Ground floor
139First Floor
140Head Room
141Watchman Shed
142Compound wall
143Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
144Ground Floor
145First Floor
146Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primer & labour to give an even shade etc. complete.
147Ground Floor
148First Floor
149Head Room
150Watchman Shed
151Compound wall
152Painting two coats with approved enamel paints of approved colour, shade including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C.
153Ground Floor
154First Floor
155Head Room
156Watchman Shed
157Compound wall
158Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete
159Ground Floor
160First Floor
161Watchman Shed
162Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows & ventilabours
163Ground Floor
164First Floor
165Watchman Shed
166Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD) Ventilator/ Top Hung 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.-
167Ground Floor
168First Floor
169Watchman Shed
170Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
171Ground Floor
172First Floor
173Watchman Shed
174Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.
175Ground Floor
176First Floor
177Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 5000 m as per Technical Specification Clause 301.5 and as per the direction of EIC.
178Ground Floor
179Construction of Granular Sub-base by providing coarsed graded materials,spreading in uniform layer by mortar grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the density, complete as per Clause - 401.
180Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with pave (AR, P-166/42)
181Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
182Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.
183G.P.H:-Supplying all materials,labour,T&P and fitting&fixing of 4.0kgf/cm2 U-PVC soil waste ventilating pipes and fitting of the following O.D conforming to ISI No. 13592/1992 to walls with nails bobbins and wooden plugs or earth work in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C.
184110mm dia PVC pipe S Trap to DB=2x0.90m+2x0.90m=3.60mP Trap to DB=2x0.60m+2x0.60m=2.40mDB to Tee=2x2.00m+2x2.00m=8.00mDB to DB=2x2.00m=4.00mP trap to DB=2x0.60m=1.20m 2x2.00m= 4.00mDB to SP=4x2.00m=8.00mTee to I/C=2x2.00m=4.00mVent Pipe=2x7.00m=14.00mP Trap to DB=1x0.60m+2.30m=2.90mDB to Tee=2x3.60m=7.20m 2x2.00m=4.00mS Trap to DB=2x0.90m=1.80mDB to DB=1x2.00m=2.00mVent Pipe=1x7.00m=7.00m
185110mm dia PVC P trap
186110mm dia PVC Door Tee
187110mm dia PVC D/J/D
188110mm dia PVC Door Bend
189110mm dia PVC Plain bend
190110mm dia PVC offset
191110mm dia PVC cowl
192125mm dia CP Grating
193Supplying all materials,labour,T&P and cutting holes through brick/stone masonry walls for taking PVC pipes and fittings including making good the damages etc all complete as per the PH specification and direction of E.I.C.
194375mm thick wall
195250mm thick wall
196Roof cutting
197Supplying all materials labour T&P and fixing wash down water closet(Anglo Indian water closet)with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cm(1:1) etc. all complete as per specification and direction of E.I.C.
198EIWC with S Trap with sheet cover(make-Parryware,Hindware)
199Supplying all materials,labour,T&P and fixing Wall Mounted Grab Bar including all complete as per specification and direction of the E.I.C.
200Wall Mounted Grab Bar 600m long
201Supplying all materials,labour,T&P and fixing wash basin with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc.all complete as per PH specification and direction of E.I.C.
202550mmx400mm WHB with 32mm dia cp west,west pipe,brackets and connection pipe(make- parryware)
203Pedestrial for basin(make- parryware)
204Supplying all materials,labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixing to wooden plugs with CP screws and washers complete as per PH specification and direction of E.I.C.
205600mmx450mm BE Mirror
206Supplying all materials,labour T&P and fixing standard size glass shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.
207(125x600)mm size glass-shelf with CP Guard rail(make -Parryware)
208Supplying all materials,labour T&P and fixing standard size CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.
209CP towel ring(make -Parryware)
210Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per P.H. specification and direction of E.I.C.
211CP Soap holder
212Supplying all materials labour T&P and fixing Ciramic tiles/marble tiles/kota tiles/ kodapa tiles/chequered tiles in floors,threads,landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and directiof E.I.C.
213In GF
214In FF
215Supplying all materials labour T&P and fixing porcelain glazed tiles/marble tiles/ Kota tiles/Kodapa tiles in dados skirting and risers of steps on 12mm thick CP(1:3)jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C.
216In GF
217In FF
218Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member,9201 as top,9200 as bottom and middle member with frame section as 9221with tapered clip no 4660 & frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board.and as per direction of the E.I.C.
219Earth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C.
220Initial lift upto 1.50m
221From 1.50m to 3.00m depth
222Supplying all materials labour T&P and filling foundation & plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royality,taxes etc. all complete as per the direction of E.I.C.
223Supplying all materials labour T&P and providing cc(1:3:6)using 4cm hg metal including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc.all complete as per specification and direction of E.I.C.
224Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
225Supplying all materials labour T&P and providing Flyash brickwork in cm(1:4) F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8%including watering,curing conveyance all material to worksite payment of royality taxes etc.all complete as per specification direction of E.I.C.
226Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
227Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
228Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips for RCC works including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
229Supplying all materials,labour T&P and providing 12mm thicks CP(1:3)with punning on brick/stone work including watering,curing conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
230Supplying all materials labour T&P and fixing MS step iron in 12mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6)all complete as per PH specification and direction E.I.C.
231Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C.
232Supplying all materials,labour,T&P and providing fitting&fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C.(a)110mmx110mmx110mm PVC Tee
233Supplying all materials labour T&P and Providing cement flush pointing(1:3)to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C.
234Supplying all materials labour T&P and providing 500x500x100mm thick RCC precast MH cover in cc(1:1.5:3)using 12mm hg chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C.
235Filling in F&P with excavated materials including watering and ramming as per direction of E.I.C.
236Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB brickwork in cm(1:6)moulding&shaping the channel inside&benching with cc(1: 1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside, cement flush pointing(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size hg chips with RCC manhole cover,e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.
237Inside size 760mmx760mmx460mm
238Supplying all materials labour T&P and laying PVC pipe sewer line Grade-A of the following internal dia in trenches(to level or slope)and jointing with gasket & stiff mixture or cm(1:1),cc(1:3:6)with 40mm size hg metal on bed of the trench and hunching or allround concrete encasing with cc(1:4:8)using 40mm size hg metal including curing,conveyance to worksite,payment of royality,taxes etc and testing all complete as per approved drawing,specification and direction of E.I.C.
239110mm dia PVC pipe with allround Hunch top
240Supplying all labour T&P and constructing soakwaypit of the following sizes with dry brick walling from bottom upto invert of inlet pipe & 1st class KB brick work in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside & outside over masonary brickwork,gravel packing in the rear of well steining RCC coverslab in cc(1:1.5:3)using 12mm size hg chips fitted handles including ew in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron work,watering,curing,conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing specification and direction of E.I.C.
24120m dia x 2.00m deep
242Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brickwork in cm(1:6)of 0.46mtr height in staging,12mm CP in cm(1:6),RCC beam of 0.25mx0.30mx2.60m in cc(1:1.5:3)using 12mm size HG chips including centering,shuttering,bending and binding of rod etc watering,curring,conveyance of all materials to work site,payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
243Stagging for 2000ltr. Storage Tank (1st Floor)
244Supplying all materials,labour,T&P and Fitting&Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.(a)2000ltr water storage tank(1st Floor)
245Supplying all materials,labour,T&P and fitting&fixing 10ltr capacity low level flushing cystern with a pair of cast iron or ms brackets complete with fittings such as syphonic arrangements 15mm nominal size brass/PVC ball valve with polythene float,CP brass handle,union and couplings for connection with inlet, outlet and overflow pipes,32mm dia c.p. flush bend,15mm dia. PVC inlet connection pipe including cutting holes and making good the same and connecting the flushbend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C.
24610Ltr.Capacity low level cistern
247Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89(sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C.
24832mm dia C-PVC pipe
24925mm dia C-PVC pipe
25020mm dia C-PVC pipe
251Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C.
252In GF
253In FF
254Supplying all materials,labour,T&P cutting holes in RCC floors,roofs etc.up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3)including finishing so as to make it leak proof as per direction of E.I.C.
255Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of E.I.C.
256In GF
257In FF
258Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.(make-Jaguar)
25915mm dia CP(SB)Bib cock
26015mm dia CP Two way Bib cock
26115mm dia CP Pillar cock swan neck
26215mm dia CP Angle Stop cock
26315mm dia Health Faucet & 1.0m long Flexible pipe
26425mm dia PVC FWV
26515mm dia CP Flange
26615mm dia CP Extension piece
2671.00HP Single Phase Submersible Pump Set
268Supplying of ISI mark 1.00HP single phase vertical submersible pump set with discharge of 900-1000ltr/hour and a head of 55-70m of reputed make like KSB/ Texmo & equivalent including all cost,conveyance and taxes etc all complete as per direction of E.I.C.
269Supplying all labour,T&P and fitting and fixing of 1.00HP single phase vetrical submersible pump set with commissioning and testing etc.all complete as per direction of E.I.C.
270Supplying fitting & fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per direction of the E.I.C.
271Supplying all materials labour T&Pand fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C.
272Supplying fitting and fixing of plastic rope MS Well cover,MS Clamp,Stainless steel short piece,bend & socket including all cost,taxes etc all complete as per direction of the E.I.C.
273Supplying fitting and fixing of HDPE Pipes & pipe fittings with making connection to pump set including all cost conveyance and taxes etc all complete as per direction of the E.I.C.
274200mmx150mm Size Bore WellL Through DTH Method:-
275Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below GL through consolidated & uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(600cfm/200psi) as required to suit the site conditions as per the direction of E.I.C.including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 200mm dia PVC/GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft,medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and with drawing after complete of tube well.(Tube well-1No)
276Drilling of 200mm. dia. Bore-0.00mtr to 44.40mtr
277Drilling 150mm dia. Bore-44.40mtr to 200.00mtr
278Lowering the following GI/PVC pipe with or without soltted pipes as per necessity from GL upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tubewell to prevent entry of foreign materials from above(PVC/ GI)supplied by the contractor(including cost of pipe)
279Lowring of 200mm dia pipes-0.00mtr to 44.40mtr
280Cost of 200mm dia PVC casing pipes-0.00m to 45.00m
281Cleaning & developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C.
282INTERNAL ELECTRICA WORK
283MAIN DB Supply & fixing of 63A TPN Panel board 1. 63A 4P 30KA MCCB with Spreader(Make- Legrand/Seimens/L&T/C&S)-1 No 2.63A Change over(Manual) (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-1 No 3. 63A COPPER bus bar- 2set 4.40A 4P MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-5Nos. 5.SPD(Type1+2,50kA,3P+N) (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-1No 6.40A DP MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand- 4 nos 7.6-32 C Series SP MCB-4 Nos 8. Digital Volt meter & Ameter three phase-2Nos 9. All accesories & Connection (Rating & Danger borad)
284Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1)
285-do- .... Group B (1.1.2)
286-do- .... Group C (1.1.3)
287S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2)
2884 Modular box with base & cover (1.24.3)
2896 Modular box with base & cover (1.24.4)
2908 Modular box with base & cover (1.24.5)
29112 Modular box with base & cover (1.24.6)
292S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
293S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE
294S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX
295S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator
296Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 )
297-do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 )
298-do- 2x4sqmm +1x1.5sqmm ( 1.8.3 )
299-do- 4x4sqmm +2x2.5sqmm ( 1.8.9 )
300S/Fof 'c' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1)
301S/F of 4 way (4+12) TPN MCB DB double door (2.5.5)
302S/F of 40A FOUR POLE MCB C Type( Make - HAVELLS /Anchor/Greatwhite/L&T)
303S/F of 63A FOUR POLE MCB C Type ( Make - HAVELLS /Anchor/Greatwhite/L&T)
304S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30)
305S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28)
306Earthing with G.I. earth pipe 3 metre long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.(3.2)
307Supply and laying 6 SWG G.I wire in recess for loop earthing as required ( 3.17)
308SITC of 1200 mm sweep A.C Ceiling fan (1 Star) copper winding with Aluminum blades having air delivery 225 m /min without fan regulator (Make: Usha-Striker Neo/Crompton-HS/Havells-Samrat ES/Anchor-Turbo Speed Star/Orient-Summer Breeze Pro/Great White-ALDOUS/Polycab-Vital HS) including wiring, the down rod of standard length (upto 30cm) with 1.5 sq. mm PVC insulated single core multistrand copper conductor etc. as required as per direction of Engineer-in-charge, Replacement Warranty will be two years.
309S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.38)
310S/F of Fan hok S'type made of 16mm MS rod as per specificationn
311S/F of 45-48 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection ( Make- Crompton/Phillips/HPL/Polycab/Havells )
312S/F of 18-25 watt LED Tube light fitting compoete with all connection. including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL)
313Supply & fixing of 12W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories.
314Supply & fixing of 15W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories.
315Supply of instalation, Testing commissioning of 12 Watt. LED bulb(Make: Havels / Phillps / Crompton / Polycab / HPL)
316S/F of 15A modular socket on 2 Modular Metal box for A.C
317S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL)
318S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand)
319S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
320S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS- OWH/ Orient-Wall43/ Great White-WYNO WF )
321S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide)
322wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm)
323Supply of 3.5core 35sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable)
324Laying of 35sq mm. 3½ Core cable on surface(5.5.2)
325Laying of 35sq mm. 3½ Core cable in ground(5.1.2)
326Supplying and making end termination with brass compression gland and aluminum lugs for 35sq mm. 3½ Core cable(5.8.21)
327SITC of 1.5 Ton 5 star BEE Rating Inverter type split A.C. M/C with all accessories and connections and installation (Make - LG/ O General/Daikin)
328S/F of 4KVA Voltage stabilizer(110-300) upto 1.5 Ton AC(Make-Microtech/V-Guard)
329Air Terminal System
330Provision of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of (IS/IEC 62561).Minimum cross sectional area should be 50 Sqmm for Al. Round ,complied as per IS/IEC 62561-2. i) Electrical resistivity-0.034 ii) Lighting impluse current of 100 kA for 10/350 iii) Tensile strength-178 mpa or N/mm2(Make: OBO/DEHN/ABB/Cape )
331Provision of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder at every 1 meter distance. Complied as per IS/IEC 62305-3 & tested as per IEC 62561-2 (Make: OBO/DEHN/ABB/Cape)
332Provision of Polyamide roof cable holder for flat roof: (frost-resistant concrete). Sleeve from polyethylene, black Conductor holder at every 1 meter distance & Complied as per IS/IEC 62305-3 & tested as per IEC 62561(Make: OBO/DEHN/ABB/Cape)
333Provision of 4 Mtr Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 . Nominal size Ø10/16 mm aluminium rod: 4 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to IEC-62305 & IEC-62561) Suitable for high wind load. Providing of Stand for Fang Fix system 16/17 kg with base ,made up of frost resistant concrete, stainless steel clamp, tested for 100KA lightning current, complied as per IS/IEC 62305-3, tested as per IEC 62561-1 . 3 nos 16kG concrete Base should be provided for 4 Mtr Airterminal. air termination rod of 4 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with supporting concrete block and fixing accessories .Test Parameter for 4 mtr vertical air terminala)ELectrical Resistivityb) Tensile Strengthc) Condition of Salt Mist (Make: OBO/DEHN/ABB/Cape)Tested as per IEC-62561
334Provision of T-cross / parallel connectors made of Stainless steel 304 grade .installation using hexagonal bolt M10X30 high grade stainless steel. Tested for 100kA lightning current.Tested for 100 KA lightning current as per IEC 62561-1 / Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be considered at every 20 mtr length of straight horizontal air termination andconnected at both the end with use of straight connector conductor(Make: OBO/DEHN/ABB/Cape)
335Down Conductor
336Provision of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of (IS/IEC 62561).Minimum cross sectional area should be 50 Sqmm for Al. Round ,complied as per IS/IEC 62561-2. i) Electrical resistivity-0.034 ii) Lighting impluse current of 100 kA for 10/350 iii) Tensile strength-178 mpa or N/mm2(Make: OBO/DEHN/ABB/Cape )
337Provision of Roof conductor holder/Polyamide holder with stainless steel base(V2A) bottom section with Ø8.5mm slot conductor holder@1 mtr distance & Complied as per IS/IEC 62305-3 & tested as per IEC 62561-2 / Stainless steel SS 304 Grade Conductor Holder for fixing the 8mm dia round conductor on the side wall .Test Parameter:Tested as per IEC 62561 (Make: OBO/DEHN/ABB/Cape)
338Provision of Test Joint (Folding Clamp) made of Stainless Steel suitable to connect 8mm round conductor and max by 30x3/25x6 mm GI strip as specified in drawing and directed by Engineer provided by The cable junction boxes can be mounted on mounting plates with sheet metal screws 3.5 x 9.5 in openings on the floor. Internal dimensions: 100x100x48 mm ,Cover with labeling field and sealable.Internal dimensions: 100x100x48 mm.Degree of protection IP66; Degree of protection IK-Code IK07 / Stainless Steel Test Joint with enclosure (IP-65) to interconnect between 8 mm Al. round conductor to Flat conductor( 30x3mm)Test Parameter:Salt Spray Test for test joint plate -No sign of CorrosionTested as per IEC 62561-1 (Make: OBO/DEHN/ABB/Cape)
339Ring & Vertical earthing system
340Provision of Galvanised Steel Flat 30X3 mm of thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized., Zinc Coatingthickness- Avg. 70 microns. , as per IEC 62561-2.,(Make: OBO/DEHN/ABB/Cape) or reputed.
341Provision of Stainless steel Cross Connector for flat conductor at cross junction.Test ParameterSalt Spray Test ( IEC 62561-1) - No sign of Corrosion. Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of bolt. (Make: OBO/DEHN/ABB/Cape)
342Provision of of Stainless Steel Conductor Holder for fixing the flat conductor on the side wall.Test Parameter:Salt Spray Test - No Sign of CorrosionTested as per IEC 62561-1 /flat conductor holder,With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot dip galvanised steel, Bottom section from polyamide, black (Make: OBO/DEHN/ABB/Cape)
343Provision of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm of length 5 mtr. Made of petrolatum- coated chemical fibre fabric to meet the requirement of IS/IIEC-62305 (Make: OBO/DEHN/ABB/Cape)
344Provision of (A)UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17 mm with copper coating thickness of 250micron tested as per IEC 62561-2. The rod should have been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467.-1 NO.(B)Universal clamp made of SS to connect rod with flat conductor -1 NO (C)Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. (D) The above arrangements shall be provided with Heavy duty earth champer of 6000kg load bearing capacity to ensure the safety of earthing system .Earth Electrode Shall be tested as per IEC 62561-2.1) Copper Coting Thickness- Minimum 250Micron.2) Electrical Resistivity Test : Maximum electrical resistivity should be 0.25 Micro Ohm Meter for Copper coated steel.3) Electrical resistance Test before and after salt mist test.4) Tensile Test.5) Bend Test6) Adhesion Test.The Earth Enhancing Mineral Compound shall be tested as per IEC 62561-7.1. Sulphur Content: Less than 2%2. Resistivity 0.2 ohm m.3. The Compound shall be tested and passed Toxicity Leaching Characteristic Leaching Properties.4. Corrosion resistance : The Value observed under dry and wetCondition is greater than 4 ohm meter square.5. The Earth Enhancing Mineral compound is non-hazardous in nature.(Make: OBO/DEHN/ABB/Cape)
345Provision of CLASS 1 +2 SPD, for power line protection, 4P ( 3PHASE +NEUTRAL), Impulse Discharge Current/POLE (10/350 s) (L -N) /(N - PE) imp,12.5 kA ( As per NBC),Nominal AC Voltage (50/60Hz) Uo / Un 240 V,Maximum Continuous Operating Voltage 300 V, Nominal Discharge Current (8/20 s) (L - N) / (N - PE) In-20KA/50 KA, Maximum Discharge Current (8/20 s) (L - N) / (N - PE) Imax -50 kA / 100 kA, Impulse Discharge Current (10/350 s) (L - N) /(N - PE) imp,12.5 kA / 50 kA, Location of Use: Main Distribution Boards Network Systems: TT, TN-S,Mode of Protection: L-N,N-PE,IEC/EN/UL Category: Class I+II / Type 1+2 / Type 1CA,Open Type 1 SPD Listed,Housing: Pluggable Design, Compliance:NBC-2016, NEC-2023,IS/IEC-62305, IEC 61643-11:2011,EN 61643-11:2012 +A11:2018,UL 1449 5th Edition . 'along with allaccesories connecting cables, lugs etc.(Make: OBO/DEHN/ABB/Cape)
346Supply and laying of 16sqmm single core copper cable for SPD To earthing(Make_Polycab/Havells/Greatwhite/Anchor)
347Installation Charges for the LA Sysytem as per EIC of approved make Including with all materials accessories ( Screw Grip, Saddle, anchor) which is required for the complete Installation. Massage on wall (Refere to Estimate)
34815 KVA DG
349S.I.T.C of 15 kVA Single Phase DG Set; Engine( Make Mahindra, EngineModel M2155G1/Equivalent model of Jackson/Kilosqure), Liquid Cooled, Natural Aspirated developing Required BHP, 2 Cylinder, Battery and with AMF panel. (Meeting Latest Emission Norms i.e., CPCB IV+) Installation of DG Set -PCC Foundation as per OEM standard, 4 Nos. Earthing connected to DG by 25x3mm GI earth strip as per OEM standard, Initial fill of Diesel 100 Ltrs.,Power Cable 3.5cx25sqmm Al armoured XLPE cable upto length 75 mtrs, Changeover switch 4P 63Amps with box of reputed make with stand inside DG shed, DG Shed with MS heavy square bar and TATA/JINDAL zinc aluminium colour coated GI sheet so that the shed covers DG more than 2 ft on all sides from DG body, square bars to be concreted in ground for adequate strength and all required accessories and connections as per OEM standard and as per direction of engineer in charge, Testing and commissioning is to be done by OEM and commissioning certificate to be signed by engineer-in-charge, gurantee card to be handed over to engineer-in-charge.
350FIRE FIGHTING
351SIGNAGE:- Providing and installing in position the following type of sign boards \\"FIRE, FIRE EXIT, FIRE EXTINGUISHER, FIRE HYDRANT & HOSE REEL, MAIN FIRE ALARM PANEL, FIRE PUMP ROOM, ASSEMBLY POINT, LIFT, STAIRCASE, FLOORS, etc\\" as per direction of Engineer-In-charge, made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over 3mm thivk cast acrylic from front side with 6mm thick acrylic, -20 to +80 deg C, Suitable for indoor use, greenish yellow, glow visible upto 4-6 hrs in total darkness. Make-Prolite/Bajaj
352SITC of conventional type Single ZONE IP55 Fire Alarm Control Panel made out of 18 Gauge (1.22mm) CRCA sheet with powder-coated finish. Compatible to all type of Conventional Detectors. with 12V & 7A two nos of Battery backup shall be sufficient for 24 hours for normal condition and 15 mins of Full Load Alarmed operation. Panel should be EN listed. Make-GST/Bosch/Cooper/AGNI
353Supply, installation, connecting, testing and commissioning of conventional type heat cum Photoelectric Smoke Detector With Remote Indicator Output and Magnetic Test Function, With Base (Certified by LPCB).Make-GST/Bosch/Cooper/AGNI
354Supply, installation, connecting, testing and commissioning of conventional Hooters min. 95 db output Make-GST/Bosch/Cooper
355Supply, installation, connecting, testing and commissioningof Conventional Manual Call Point in ABS plastic as required complete.Make-GST/Bosch/Cooper/AGNI
356Looping Cable Supplying, installing, testing and commissioning of Fire Survival armoured cable,Fibre glass tape wrapped, ZH inner, outer sheath 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specificationsMake-GST/Bosch/Cooper/AGNI.
357FIRE EXTINGUISHERS :Providing & fixing ABC type (Dry powder type ) extinguishers. Including all accessories as per IS specification (IS :15683) Consisting of welded MS cylindrical body with discharge hose ,discharge valve ,suspension brackets,initial filling etc. complete as required., initial filling etc complete as required. Capacity - 6 kg . Make : Fireshiled/ Kanex/ Safex/AGNI
358Providing & fixing Water based Carbon-di-oxide 4.5 ltrs. fire extinguishers as per IS specification consisting of welded MS cylindrical body ,squeeze lever discharge valve fitted with internal discharge tube ,30 cm long high pressure discharge hose ,discharge nozzle,suspension brackets,finished exteranally with red enemel paint and fixed to wall with brackets with rawl plug/dash fastners complete with initial charging. Make : Fireshield/Kanex/ Safex/ AGNI
35910 PASSENGER LIFT WITH WIRRING(1.1) Supply installation testing & commissioning of 10 passenger lift Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58082716
AUTHORITY Government Departments
TENDER VALUE 1.94 Crore
LAST DATE 02-11-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of Office Building Of Assistant Labour Officer At Koida Block
Basic Detail
Tender No RWCCESNG-32 of 2026-27
Bidding Type Tender
Location
City Sundargarh
State Odisha
Key Dates
Publish Date 16 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 1.94 Crore
Tender Fee 10000
EMD 1.94 Lakhs
Exemption Available
Document List
b492f04a-6a59-47a4-b787-fe6be0a72180.html
BOQ_614523.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

b492f04a-6a59-47a4-b787-fe6be0a72180.html

xls

BOQ_614523.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender