Tender For Renovation Of Urban Phc At Jajpur As Per Ama Hospital Standard For The Year 2025-26
Tender Value
43.09 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
5 days left
EMD
43098
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jajapur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Urban Phc At Jajpur As Per Ama Hospital Standard For The Year 2025-26
BOQ
| Sl. No. | Item Description |
| 1 | Civil ItemsDismantling brick or stone masonry in lime or cement mortar under 3m height including stacking the useful materials for reuse and removing the debris within 50m lead etc complete. |
| 2 | Fly ash brick 25mx12cmx8cm masonry in cement mortar(1:6) after immersing bricks for six hours in water before use in F&P with all necessary projections using Bricks of 10 size having a crushing strength of not less than 75Kgs/Sqcm. Including splays cutting, circular moulding, chamfering, corbelling and similar such types of works with all necessary projections watering and curing. complete including cost and conveyance, royality & taxes of all materials and labour with T&P required for the work with all etc. complete in all all respect in all floors with all other specifications as per the direction of Engineer-in-charge. |
| 3 | 12mm.(1/2) thick cement plaster (1:6) finished smooth to inside/ outside brick walls after raking out the joint including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalties etc. complete in all respect in all floors as per the direction of the Engineer-in-charge.Civil & Boundary wall |
| 4 | Wall Painting 2 (Two) coat with any approved plastic emulsion paint with brush to outside wall surface after cleaning surface including cost of paint watering and curing cost conveyance and taxes of all materials and labour with T&P required for the work etc. complete |
| 5 | RCC Work of M-20 grade using 12mm to 20mm (1/2 to 3/4 size (20mm not to be exceed 25%) hard black crusher broken granite stone chips of approved quality and from approved quarry including hosting lowering, laying concrete and compacting by using vibrators watering for 4 weeks including centring shuttering and finishing the exposed surface and providing grooves or beads where necessary including cost, conveyance, taxes and royalties of all materials and labour with T&P required for the work etc. Complete in all respect but including cost of M.S rod or tor steel and biding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, biding wires and tying the grills and placing in proper position including all other specifications as per the direction of the Engineer-in-charge.a) Lintel |
| 6 | b) Column Base (Boundary Wall) |
| 7 | c) Plinth Band (Boundary Wall) |
| 8 | d) Column (Boundary Wall) |
| 9 | Supplying ,Cutting, Bending, Binding, Straightening, Placing HYSD bars confirming to grade I.S.1786-1985 (Fe-500) in CD works, retaining/toe wall and other structures as per drawing and technical specification and as per Section.900, 1000, 1600, 2100, 2200 & 2300 of specifications for Road and Bridge works of Ministry of Road Transport & Highways (5th Revision) & including cost of all materials, labour, T&P, taxes, royalty etc complete in all respect and as per direction of the Engineer-in-charge.Civil & Boundary wall |
| 10 | Supplying fitting and fixing vitrified tile(Plain Ivory) in dadoes skirtings and risers if step of size 600mm x 600m of approved make confirming to US 13755 laid on 12mm thick CM(1:3) and filling joints with white cement of approved quality including cost of all materials labour T&P etc required for the work all complete. |
| 11 | Providing fitting and fixing of Cup Board made up with 19mm thick BWR Ply, 2 Nos of selves & INo of Partition outside pasting with 4mm thick veener with inside pasting Imm thick sunmica including cost, conveyance and taxes of all materials and cost of all labour, sundries and T&P etc. required for the work complete as directed by the Engineer-in-charge. |
| 12 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost,conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 13 | Iron work wrought and put up in trusses including labour and cost etc complete as per the direction of the Engineer-in-charge |
| 14 | Labour for fixing Blue Coloured Durashine Sheet in roof drilling holes in wind ties including fixing of ridges valleys, wind ties and cost of sheet etc complete. |
| 15 | Supplying fitting fixing MS grill in position including cutting to size, grading and welding fitting and fixing with cement concrete (1:2:4) as per approved size and approved design including cost, conveyance, royality, taxes of all materials etc complete as per direction of the Engineer-in-Charge (Design of grill and the size of materials approved by the Engineer-in-Charge before making and theweight will be taken for payment of finished materials before fixing)Civil & Boundary Wall |
| 16 | Earth work excavation in hard soil within 50m lead and 1.5m lift including rough dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and T&P and dewatering if required for the work etc. complete and as directed by the Engineer-in-charge. |
| 17 | Supplying, filling sand of approved specification on compacted surface filling in foundation and plinth proper thickness including surface dressing, watering and ramming with the conveyance royalties, taxes of the materials and labour with T&P required for the work etc. complete. |
| 18 | Cement concrete (1:3:6) in foundation and floors using 4cm size down graded crusher broken clean hard black broken granite stone metal in desied thickness of approved quality and from approved quarry including hoisting, lowering. complete including cost and conveyance of all materials with all taxes and royalties and all labour with T&P required for the work etc. complete, including dewatering if required as per direction of the Engineer-in-charge. |
| 19 | Fly ash brick 25mx12cmx8cm masonry in cement mortar(1:6) after immersing bricks for six hours in water before use in Superstructure with all necessary projections using Bricks of 10 size having a crushing strength of not less than 75Kgs/Sqcm. Including splays cutting, circular moulding, chamfering, corbelling and similar such types of works with all necessary projections watering and curing. complete including cost and conveyance, royality & taxes of all materials and labour with T&P required for the work with all etc. complete in all all respect in all floors with all other specifications as per the direction of Engineer-in-charge.Boundary wall |
| 20 | 16mm.(5/8) thick cement plaster (1:6) finished smooth to inside surface of 9/10 thick brick walls after raking out the joint including watering and curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalties etc. complete in all respect in all floors as per the direction of the Engineer-in-charge.Boundary wall |
| 21 | Finishing wall surface with cement based wall putty (water based) of approved make and finished smooth to bring a even surface to receive painting including cost of putty etc. conveyance, royalties and taxes of distemper and all other materials and labour with T&P required for the work as per the direction of the Engineer-in-charge. Boundary wall |
| 22 | Finishing Wall 2 (Two) coats with any approved Weather Coat paint with brush to outside wall surface after cleaning surface including cost of paint, watering and curing cost conveyance and taxes of all materials and labour with T&P required for the work etc. complete.Boundary wall |
| 23 | Painting 2 (Two) coats with any approved Enamel paint with brush to outside wall surface after cleaning surface including cost of paint, watering and curing cost conveyance and taxes of all materials and labour with T&P required for the work etc. complete. |
| 24 | E.I ItemsSupply & Installation of Wall Speaker Unit with wiring and all accessories and connection as per the Engineer in charge |
| 25 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point.GROUP-A(QTRS) |
| 26 | GROUP-B(QTRS) |
| 27 | GROUP-C(COMMON ARAE) |
| 28 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 29 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 30 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 31 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable or equievalant) in recessed PVC conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge.. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 32 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 33 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 34 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 35 | Supplying and fixing of following sizes of heavy class FRLS PVC conduit (Make-AKG/Polycab/precision/norpack/sudhakar) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .(For TV/Internet cable /Fire detection only)20 MM |
| 36 | Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/Hagar/ABB/C&S /Panasonic) |
| 37 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 38 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge . |
| 39 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 40 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Make-Havells/Bajaj/Usha/Crompton |
| 41 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . |
| 42 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required. panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 43 | SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holder as required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient |
| 44 | Supplying ,installation ,testing & commissioning of 1 KVA ,240V UPS with all required accessories & suitable nos 12v battery,220Ah tubular type,battery rack as per the direction of Engineer in Charges.Make-V-guard/Microtech/Luminous . (only for common area) |
| 45 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required |
| 46 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required |
| 47 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB SB 200. Model of ABB/LK/Hager/C&S/Havells/Panasonic. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. . |
| 48 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years. |
| 49 | S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years |
| 50 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 51 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 52 | Supply Tasting Commissioning of RGB LED Base Billboard at Government Polytechnic Balangir.Size Of Billboard 8 Feet X 6 Feet.Cabinet Size 600X600 Items 12 No (2X2)FeetScanning Mode 1/8%Pixel Pitch 10 NoModule Resolution 32X32Module Size(mm) 192X192Pixel Density 27777Brightness(sd/m^2) 4200Module Weight (kg) 0.35Max Current (A) 7.75Screen Power Consumption (W/M^2) 946Optimum Viewing Distance(m) 6LED Encapsulation SMD2525Driving IC PWM-SS ICRefresh Rate(HZ) 3840Optimum Viewing Angle(X) Horizantal 140*, Vertical 130*Gray Scale(Bit) 14-16Attenuation 15%MTBF 10000 HoursDefective Rate <0.0003 Before deliveryIP Grade IP (Front Side) |
| 53 | Video Processor Y2I / USB Drive for Use Pendrive |
| 54 | LAN Card for the use Video Automatic processing by Internet |
| 55 | Frame Structure for Sign Board: Supply and Fixing of Steel Frame Structure for Supporting of LED Sign Board made out of 40x40mm, including required Fabrication, 2 cots Gray Painting Asian Paint M.S.Pipe:- 12X12 Inch hallow square M.S.Pipe framed fixing of Individual Letter.(Tata, Jindal, SAIL Steel). |
| 56 | Installation, testing, Commissioning, Transporting, Labouur charges on signboard. |
| 57 | Supply & Fixing of 43\\" LED TV Unit(Make- SONY/LG/SAMSUNG) |
| 58 | Supply, Installation, Testing & Commissioning of Queue Management System |
| 59 | Supply & Installation of 2-5MP CCTV Cameras , Casing & Caping of CCTV Cables as per direction of Engineer in Charge |
| 60 | Supply of 1.5 TR high wall 3 star invetrer type split A.C. Make-Hitachi/carrier/Voltas /Daikin |
| 61 | Supply and Fixing of 4 KVA Stabilizer.(Make-V-Guard,Mocrotek,Shakti |
| 62 | Supply and Fixing of 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit . (2X4+1X1.5) |
| 63 | Supply ,Installation & Fabrication of hard/soft copper refregerant piping complete with fittings of bends and other necessary material to complete the job.(1 TR to 3 TR High wall Split Ac) |
| 64 | Supply ,Installation & Fabrication ofinsulated drain water piping from indoor to nearest drain point separate to all and other necessary material to complete the job..(1 TR to 3 TR High wall Split Ac) |
| 65 | Supply and Fixing of Ms anfgle for outdoor unit as per the direction of engineer in charge |
| 66 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge . |
| 67 | Supply and Fixing of 15/16 Amp 3 pin Top .Make-Havells/Crompton/Anchor |
| 68 | Installation charge of Split AC Machine |
| 69 | P.H itemsSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) 25mm dia PVC ASTM pipe (sch-80) In ground floor |
| 70 | 25mm dia PVC fullway valve(Asirvad Make) |
| 71 | Grab Bar Left 90 Angle white(Cera)No.82210104 |
| 72 | Grab Bar 692mm long white(Cera)No.82210106 |
| 73 | Grab Bar Vertical swing white(Cera)No.82210107. |
| 74 | Supplying all materials, labour, T&P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) In ground floor 110mm dia U PVC SWR pipe |
| 75 | 110mm U-PVC plain bend |
| 76 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 80 PSS RO+UV Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer