Educational and Research Institute Government Departments Closing in 11 days TDR #58082689

Tender For Repairingreplacement Of Unserviceable Lt Cables , Mccbs And Other Connected Items In Residential Complex At Aiims Rishikesh.

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
42.50 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
11 days left
EMD
2.12 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairingreplacement Of Unserviceable Lt Cables , Mccbs And Other Connected Items In Residential Complex At Aiims Rishikesh.

BOQ

Name of Work:- RepairingReplacement of unserviceable LT cables , MCCBs and other connected items in Residential complex at AIIMS Rishikesh.
Sl. No. Item Description
1Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge. 100 A, 16 KA,TPMCCB
2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge.125 A, 16 KA,TPMCCB
3Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge. 200 A, 25 KA,TPMCCB
4Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge. 250 A, 50 KA,FPMCCB
5Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge.315 A, 35 KA,TPMCCB
6Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge.400 A, 50 KA,FPMCCB
7Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making arrangement to fix in the existing panel by making connection with suitable size extended terminal spreader, rotating handle etc. as required at site (Ics=100% Icu) and Operational Voltage 690V etc. as required as per direction of Engineer In Charge.630 A, 50 KA,FPMCCB
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
9Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Double pole(40 A)
10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral(40 A)
11Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I). 3 X 6 Sq. mm
12Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I). 3 X 10 Sq. mm
13Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I). 4 X 16 Sq. mm
14Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I). 3.5 X 25 Sq. mm
15Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I).3.5 X 35 Sq. mm
16Supply of following sizes, XLPE insulated and PVC sheathed Al. conductor Armoured 1.1 KV grade power cable confirming to IS: 7098 (Part I).3.5 X 95 Sq. mm
17Supplying & fixing of following sizes of PVC/XLPE insulated PVC sheathed copper, armoured, cable of 1.1KV grade, as per IS applicable complete as required. 3X1.5 sq mm
18Supplying & fixing of following sizes of PVC/XLPE insulated PVC sheathed copper, armoured, cable of 1.1KV grade, as per IS applicable complete as required. 3X10 sq mm
19Supplying & fixing of following sizes of PVC/XLPE insulated PVC sheathed copper, armoured, cable of 1.1KV grade, as per IS applicable complete as required. 3X25 sq mm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
21Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sqmm, Upto 35 sq. mm
22Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
23Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., 63 mm dia (OD-63 mm & ID-51 mm nominal)
24Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.,90 mm dia (OD-90 mm & ID-76 mm nominal)
25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3 X 10 sq. mm (19mm)
26Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 16 sq. mm (28mm)
27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 X 25 sq. mm (28mm)
28Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 X 35 sq. mm (32mm)
29Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
30Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A
31Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, 40 A
32Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, 63 A
33LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).90 Watt
34LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt
35Supply installation Testing and Commissioning of three phase star-delta starter 415 V,50 Hz of relay range 45 to 90 Amp with short circuit protection Overload protection suitable to operate 3 phase,415 Volt 50 Hz AC Supply having minimum one year warranty i/c connection etc. as reqd. for satisfactory performance of the starter complete with Ammeter and Voltmeter of suitable range) Make - LK Model MU-G75S or equivalent model of BCH Premium FASD
36LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 watt
37LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150 watt
38Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge
39Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58082689
AUTHORITY Government Departments
TENDER VALUE 42.50 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Tender for Repairingreplacement Of Unserviceable Lt Cables , Mccbs And Other Connected Items In Residential Complex At Aiims Rishikesh.
Basic Detail
Tender No 05/EE/Electrical/2026-27
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 16 Oct 2026
Submission Date 09 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 42.50 Lakhs
Tender Fee Ref. Documents
EMD 2.12 Lakhs
Exemption Not Available
Document List
bf3c57c3-21bb-4637-8324-fe5425d541a6.html
BOQ_977986.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

bf3c57c3-21bb-4637-8324-fe5425d541a6.html

xls

BOQ_977986.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender