Public Administrative Department Local Bodies Closing in 0 days TDR #58082482

Tender For Construction Of Town Hall At Sawai Madhopur

Issued by Local Bodies · Sawai Madhopur, Rajasthan
Tender Value
14.63 Crore
Estimated cost
Bid Submission
12 Nov 2026
0 days left
EMD
29.26 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sawai Madhopur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Town Hall At Sawai Madhopur

BOQ

Name of Work:- Construction of Town Hall at Sawai Madhopur
Sl. No. Item Description
1CIVIL WORK
2SUB HEAD - EARTHWORK
3Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
40.00 to 1.50m
51.50 to 3.00m
6Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion).
7Diluting and injecting Chlorpyriphos/ Lindane E.C. 20% with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
8SUB HEAD - CONCRETE WORK
9Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - 1:3:6 (1 Cement : 3 fine/ coarse sand : 6 graded stone aggregate 40 mm nominal size).
10Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix)
11Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix)
12Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix)
13Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof.
14Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand) including the cost of required centring, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
15Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix)
16SUB HEAD - STEEL WORK
17Reinforcement for R.C.C. work at all levels including straightening,cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
18Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes
19Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275gm/m²
20Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover.
21Providing and fixing ball bearing for rolling shutters.
22Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area.
23Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube.
24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
25Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
26SUB HEAD - FORM WORK
27Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :
28Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
29Foundations, footings, bases of columns, etc. for mass concrete.
30Suspended floors, roofs, landings, balconies and access platform.
31Edges of slabs and breaks in floors and walls. Under 20 cm wide
32Lintels, beams, plinth beams, girders, bressumers and cantilevers.
33Columns, Pillars, Piers, Abutments, Posts and Struts.
34Stairs, (excluding landings) except spiral-staircases.
35Add extra for doing centering and shutteriing work for each subsequent storey above two storey. (height 3m or part thereof)
36Ht. 7.5 m to 10.5 m
37SUB HEAD - BRICK WORK
38Brick work with modular bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
39Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately).
40Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
41Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand)
42SUB HEAD - FINISHING WORK
43Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 coarse sand)
44Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
45Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand)
46Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
47Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer.
48Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
49Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
50Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : Red sand stone - Exposed face fine dressed with rough backing. 30 mm thick.
51Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75mm and by providing layer of 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge.
52Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : White sand stone - Exposed face fine dressed with rough backing. 70 mm thick.
53Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.
54Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required.
55Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases.
56Painting new letters and figures of specified size, of any shade with first quality synthetic enamel paint, black or any other approved colour to give an even shade as per clause 801 of MoRT&H Specification including all material, labour. English and Roman (Hyphens, commas and the like not to be measured and paid for)
57Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
58Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
59Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
60Neat cement punning
61Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in whitcement mortar 1:2 (1 white cement : 2 stone dust) with an admixturof pigment, matching the stone shade, jali slab without any chamferetc. Red Sand Stone
62Providing and laying marking of center line and stop line etc with hot hermoplastic compound 2.5 mm thick on road/ plain surface, ncluding reflectorising glass beads @ 250 gms per sqm area with special applicator machine, as per IRC:35 including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control involved. The finished surface to be level, uniform and free from streaks and holes as per clause 803 of MoRT&H Specification including all material, labour, machinery, lighting,guarding and maintenance of diversion.
63SUB HEAD - FLOORING WORK
64Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.
65Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Area of each slab 900 to 2000 sqcm
66Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
67Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) or slab in wal, steps, pillars, counters, jambs, shelves, sills etc laid over 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand), jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Above 3601 Cm2 Slabs
68Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the the cost of cement plaster on wall and pillar) Size 600mm x 600mm
69P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm
70P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. Size 800mm x 800mm
71Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.
72Green / Black Upto to 1501 Cm2 to 3600 Cm2 Tiles
73above 3601 Cm2 Slabs
74Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
75Marble work
76Granite Work
77Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete
78Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
79Extra for Mirror polishing on marble work where ever required to give high gloss finish complete.
8040 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone
81Precast terrazo tiles 20mm thick with graded marble chips of size upto 12mm laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete with precast tiles on 20mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Ordinary cement without any pigment.
82Providing and laying wooden flooring with a direct laminated surface treated with aluminium oxide on top of a high-density fiber board with a density of 850 Kg./per Mtr. having a click system tongue and groove joint to secure a long lasting joint. The planks are or termite resistant and water protected with both side lamination Wooden flooring Planks of size 1208 x 194 x 8 mm / 1215x294x8 mm (8mm thick laminated floor class of use 23/31 having a wear resistance level of AC-3 , impact resistance > 9mm, moisture resistance 3-10% as per (EN-424, EN – 438 EN – 425 EN – 417 – 2)or PREN 3329 complete in all respect as per direction of EI
83Providing and laying of skirting 89 mm wide having both sidelaminations with moulding in upper side with matching of floor fixingwith nails and screws & fevicol complete in all respect as perdirection of EI.
84Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : One face dressed. Red sand stone
85SUB HEAD - ROOFING WORK
86Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
87Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
88Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum board conforming to IS: 2095-Part I,
89Providing & fixing following False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, spaced at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. 8mm thick calcium silicate perforated ceiling tiles
90Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
91Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately For the purpose of measurement the entire treated surface will be measured.
92SUB HEAD - WOOD, PVC & GLASS WORK
93Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design.
94Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B
95Providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 35 mm thick Nigeria wood grade I
96Providing and fixing external grade board solid core single leaf flush door shutters ISI 220267 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure 'A' : 35 mm thick Decorative teak veneer both side
97Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured)
98Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : Rectangular or square.
99Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sal wood
100Providing and fixing factory made uPVC door frame made of uPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be mitred and welded of plastic, galvanized brackets and stainless steel screws. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge Extruded section Profile size 48x40 mm.
101Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 8 mm thickness
102Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
103Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 450MM long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms.
104Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms.
105Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality).
106Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 20 mm diameter.
107SUB HEAD - PLUMBING WORK
108Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
109Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
110Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
111Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
112Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250mm.
113Providing and fixing 100 mm sand cast Iron grating for gully trap.
114Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357mm
115Providing and fixing toilet paper holder : C.P. brass
116Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31mm of 79mm length and 62mm breadth weighing not less than 45gms.
117Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms.
118Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
119Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
120Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.,
12120 mm nominal outer dia .Pipes.
12232 mm nominal outer dia .Pipes.
123Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
12475 mm nominal inner dia .Pipes.
125100mm nominal inner dia .Pipes.
126Providing and fixing brass bib cock of approved quality : 20 mm nominal bore
127Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
128Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
129Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 20 mm nominal bore
130Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.
131Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.
132Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
133Providing and making connection to the manhole/ road side chamber/ property chamber by cutting hole in wall, making good the same with brick work/ stone masonry work in cement mortar 1:4, plaster in cement mortar 1:3, encasement of pipe at manhole with 75mm thick M15 grade concrete etc complete as directed by Engineer.
134Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter
135Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
136Brick bats
137BILL OF QUANTITY - B (SITE DEVELOPMENT WORK)
138SUB HEAD - EARTHWORK
139Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
1400.00 to 1.50m
1411.50-3.00 M
142SUB HEAD - CONCRETE WORK
143Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - 1:3:6 (1 Cement : 3 fine/ coarse sand : 6 graded stone aggregate 40 mm nominal size).
144Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix)
145Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix)
146Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix)
147Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
148Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
149Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, balconies and access platform.
150Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Columns, pillars, posts and struts etc.
151Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for ::- Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
152Reinforcement for R.C.C. work at all levels including straightening,cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
153Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:4 (1 cement : 4 coarse sand)
154Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
155Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand)
156Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube.
157Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 coarse sand)
158Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand)
159Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer.
1606 mm thick cement plaster of mix 1:3 (1cement : 3-fine sand)
161Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
162Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
163Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
164Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
165Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the the cost of cement plaster on wall and pillar)
166P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm
167Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B
168Providing and fixing external grade board solid core single leaf flush door shutters ISI 220267 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure 'A' : 35 mm thick Decorative teak veneer both side
169Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 8 mm thickness
170Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately For the purpose of measurement the entire treated surface will be measured.
171Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
172Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
173SUB HEAD - PLUMBING WORK
174Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
175Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
176Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
177Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250mm.
178Providing and fixing 100 mm sand cast Iron grating for gully trap.
179Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357mm
180Providing and fixing toilet paper holder : C.P. brass
181Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31mm of 79mm length and 62mm breadth weighing not less than 45gms.
182Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms.
183Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
184Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.,
18520 mm nominal outer dia .Pipes.
18632 mm nominal outer dia .Pipes.
187Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
18875 mm nominal inner dia .Pipes.
189100mm nominal inner dia .Pipes.
190Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 20 mm nominal bore
191Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.
192Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.
193Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
194SUB HEAD - ROAD & FOOTPATH WORK
195Earth filling with available surplus soil excavated from foundations and taken onl y from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m.
196Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
197Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30
198Providing, laying and spreading of granular sub-base by providing coarse graded Material (Table 400-2), spreading in uniform layers with motor grader on prepared surface, mixing BY MIX IN PLACE METHOD with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. Grading - I Material
199Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic viebro pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted subbase as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. 80mm thick cosmos shape
200Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand) including the cost of required centring, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
201Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
202SUB HEAD - RAIN WATER HARVESTING
203Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). 200 mm dia Nominal bore
204Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/1992) of grade Fe410 of following nominal bore sizes at site of work. 200 mm dia
205Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia
206Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded 20mm nominal size stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick
207Aggregates 90 mm to 45 mm (hand broken)
208Aggregates 25 mm to 10 mm
209Aggregates 10 mm to 5 mm
210Coarse sand
211Stone slab roofing on ground floor with fine grained stone slab 90mm average thickness from approved quarry including filling of joints slab in cement sand mortar 1:4 with ceiling pointing in cement sand mortar 1 : 3 complete as per specification for span: Up to 2.00 metre.
212Providing, lowering, laying in trenches, aligning, fixing in position and jointing socketed rubber gasket type ISI marked uPVC pipes of Class III (6 Kg/sqcm) suitable for potable water with rubber ring joints (as per IS 4985-2000) of following outer dia with all accessories (excluding specials) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 110 mm dia
213Providing, lowering, laying in trenches, aligning, fixing in position and jointing uPVC pipe fittings/ accessories of class III (6 Kg/sqcm) confirming to IS:7834 suitable for potable water with rubber rings joints in uPVC pipe line at all levels/ depth including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.
214Equal Tee (Moulded) welded with socket 110 mm dia
215Double/Single socketed 90 degree long bend (single piece welded with socket) 110 mm dia
216uPVC End Cap 200mm dia
217uPVC pipe clip 110 mm
218Galvanised wire mesh of average width of aperture 1.18 mm nominal dia. wire 0.556 mm
219SUB HEAD - SEWER WORK
220Earth work for Sewer line and Manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re-handling of material/earth to complete the task. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
221Dismantling of cement concrete pavement for sewer line and manholes by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), rehandling of material/earth to complete the task.
222Providing and laying in position cement concrete 1:3:6 (1 Cement : 1 graded stone aggregate 20 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration under sewer line and manhole work including allowances for any additional road restoration beyond the drawings (measurement for payment to be as per standard drawings) to complete the task.
223Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round HDPE DWC (double wall corrugated) pipes of SN8 grade as per IS 16098 (Part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications, drawings and as per direction of Engineer. Note : E/w to be measured and paid separatel y. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipein the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. 200 mm ID
224Providing granular bedding having width = outer dia of pipe (Bc) + 500mm, thickness below pipe = 0.25Bc or 100mm (whichever is higher) and haunching = 0.5Bc, with graded hard crusher broken stone of 100% passing through 20mm sheive, 20 to 50 % passing through 10mm sheive and 100 % retain on 6.3mm sheive, laying in layers of thickness 10/15cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Engineer. 200 mm ID
225Pre-cast RCC M-40 grade circular manholes 1.055 m deep to invert with pre-cast manhole cover frame (height 0.20), conical piece (height 0.605), cast-in-situ PCC M-10 grade foundation, PCC M15 grade circular wall ID 0.925m, wall thickness 200mm height equal to OD of sewer pipe + 50mm, PCC M15 grade benching and channel portion.
226Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.0m, wall thickness 125mm, height 150/225/300/600 mm for constructing extra depth of manhole beyond depth mentioned in item no-17.59.1 as per drawing.
227Providing and fixing Barricading at site of work for restricting the general public using 80-100 mm dia Wooden Ballies as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 80-100 mm Wooden Ballies as horizontal members with jute russies. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis)
228STP (20KLD)
229RUIDP Tecknology - Design, supply, erection, installation, jointing, testing, trial run, and commissioning of prefabricated micro Sewage Treatment Plants based on RUIDP Technology for Inlet parameter (Ph-6.5-7.5; BOD5 @ 20 degree C-300 mg/l; COD-650 mg/l; TSS600 mg/l; TKN-55 mg/l) and outlet parameter (Ph-6.5-9.0; BOD5 @ 20 degree C < 10 mg/l; COD-<= 50 mg/l; TSS- <=20 mg/l; N-Total- <=10 mg/l & Faecal Colliform-<100 MPN/100 ml)complete in all respects. STP will have following components:-
230Pretreatment Unit:- Design, Supply, Fabrication of Coarse Screen with Grit Separator Unit. The fine screen (2 Nos.; 1 W+1S) installed in sequence shall be made in SS316L using flat bars of 3 mm thick, 50 mm wide and spacing of 5 mm, tear shape and dimensions of the bar screen as per design approved by engineer. The grit and oil filter separation unit shall be also provided in SS 316 L with interconnecting pipeline made in 90 mm HDPE PE-100 PN-6 as per IS 14333 (amended up to date), necessary fittings while maintaining the hydraulic levels with capacity of removing grease, oil and grit particles having specific gravity 2.85 with removal efficiency of 80%.Prefabricated sump with non clog sewage submersible pump set 1 W +1S of 2% Ni CI Cascading, Impeller CF 8M ,Shaft SS 410,mechanical seal with 10M Power & Control cable , 5M Galvanized Chain,,10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. installed after the oil and grease chamber. Adequate arrangements shall be made for access to remove the screened waste and settled grit on manual basis.
231Primary Settling Tank Unit:- Design, Supply, Fabrication of Primary Settling Tank in Mild Steel of 2-4 mm thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions as per approved design and drawing by engineer. Necessary support elements shall be provided inside the Primary Settling Tank at a depth of 700mm(minimum) from the top and further down minimum depth of 1.250 m (0.50 m free board extra) for support of the Tube Deck Media. A conical section with adequate slope (1: 12) for sludge to settle and flow down into the sludge storage tank shall be provided. The construction shall be as per the provided drawing. Safety Rails shall also be provided around the top of the tank in 2 rows connected with vertical poles of 1.2 m height at 1.2 m distance apart of Aluminium pipe of 32 NB with odular fittings. A partition shall be provided after the Tube Deck media for collection of clarified effluent which shall be collected while flowing in upward direction. Including GST, Taxes and duties and erection at site.
232Secondary-cum-Biological Treatment Unit:- Design, Supply, Fabrication of Secondary cum Biological Treatment Unit in Mild Steel of 2-4 mm Thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions as per approved design drawing by employer with 3 vertical partitions (minimum) at equal spacing for a minimum length of 3.0 m. The depth of the partitions shall be minimum 1.250 m (0.50 m free board extra) from the vertical. The bottom of the unit shall be conical in shape for sludge collection , fraction of which shall be recycled back into the top most zone of the unit. The construction shall be as per the provided drawing. Safety Rails shall also be provided around the top of the tank in 2 rows connected with vertical poles of 1.2 m height at 1.2 m distance apart of Aluminium pipe of 32 NB with modular fittings. The outlet portion shall be meant for overflow with a depth of 0.50m from the Top water level as provided in the section drawing.
233Tertiary Treatment Unit:- Design, Supply, Fabrication of Tertiary Treatment Unit Mild Steel of 2-4 mm Thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions with circumference around the Primary and Secondary Treatment Units , width of 1 m (minimum) and depth of 1.5 m (minimum). The tank shall have partitions opening from top and bottom in alternate arrangement to provide sinusoidal flow. A drain valve arrangement shall be provided to collect the wash out sludge during any maintenance event.
234Filter Media:- Filter media of required distribution and proportion to be filled in the Tertiary Treatment Unit (Qty of 100 mcube or as per deign requirement to fill to the top water level) , required hydrophytic plantation & impregnating inside the Tertiary Treatment Filter Bed.( Qty: 200 Nos of Umbrella Palm & Caina Indica) Bio consortium media comprising of Bacillus sp, bacteriofaciens sp, Phosphatidis sp, Nitrobacter sp, and other Nutrient removing species in wetland systems. (Qty of 100 liters)
235Solar Power System:- Supply, Fabrication, Installation, Testing and Commissioning of Solar Power Unit MNRE approved of required capacity including allelectrical, peripheral and mounting accessories. H) Sludge Storage tank:- Sludge storage tanks for primary and secondary sludge with a capacity of 2000 Liters as per the levels provided in the reference drawing, this sludge tank will be connected to the primary settling tank and secondary treatment unit bottom with 110 mm HDPE PE 100 PN-6 pipe with fillings as per IS 14333 (amended up to date). Manually operated butterfly valve of 100 mm dia shall be installed on both coming pipes to regulate the sludge flow.
236RUIDP Technology component:- Supply, Administering, Installation and commissioning of only the Technology Components for :
2371. Primary Settling Tank :- Macroporous Hydrogel constituting of polymers like Polyacrylamide gel - cross linking polymer of Water Insoluble entities with a life span of at least 5 years , impregnated and immobilized with acid resistant Methanation Bacteria like Methanosarcina sp on to the water flowing surface using synthetic adhesives. The system shall be capable for easy installation and maintenance.
2382. Secondary Treatment Unit:-
239Floating rafts of appropriate size as per the provided drawing made of natural materials like bamboo or buoyant material with hydrophytic plantation on top to be installed in the upper most layer of the unit.
240Middle Layer comprising of non-organic media support immobilized with aerobic bacteria. The media for support shall be alumina or ceramic based of cylindrical or spherical shapes with minimum 50% porosity to allow favorable bacteria for immobilization and colony formation. Total Depth of the middle layer shall be 925 mm with percentage fill of the media ranging between 35-50% depending on the hydraulic conductivity of the packed bed media column to cater to the peak flow. The average mean diameter of the media elements shall range between 5- 20 mm.
241Bottom Most Layer: comprising of thermosetting resin polymer media with infinitesimal shape and protected surface area of not less than 900 m2/m3. Minimum % fill of 35% and the Middle and Bottom layer shall be separated using retractable strainers made in UPVC or FRP lined MS grating for providing support for middle layer media , the same support shall be provided for the bottom most layer.
242Manual Micro screen 1 mm 1W +1S in SS-316 at the outlet of secondary unit\\"
243Other Ancillary works -
244Boundary wall with gate of premises - wall height shall be 1.5 m from FGL. Foundation of boundary wall shall be 1.20 m below natural ground level. Construction up to plinth level shall be in RR masonry in 1:6 cement mortar with 100 mm thick PCC in 1:4:8 below masonry. First wall section shall be 90 cm wide with 30 cm height, and above it, second section of wall shall be 75 cm wide with 30 cm height, and above it, third section of wall shall be 60 cm wide with 30 cm height. and above it, fourth section of wall shall be 45 cm wide with 30 cm height. Above it, a brick (class-75) masonry wall of 30 cm thick with provision of columns of 45 cm x 45 cm at an interval of 3 m along with suitable joints provisions shall be constructed in CM 1:6.,
245Access Road to STP with Drains - From gate of STP area to the different units of STP and all around precast concrete interlocking tiles at pedestrian and shoulders shall be of 80 mm thick and approved shape of M 30 grade laid on 75 mm thick PCC 1:4:8 on proper slope with side drainage of vibro-pressed 60 mm thick precast l-shape drains of 0.23X 0.3m on both side laid on 75 mm thick PCC 1:4:8.
246Admin-cum-control-cum-laboratory-cum-office with toilet block building as per approved design and drawing by the engineer (maximum area of 15 sqm.)
24711 KLD - 25 KLD
248BILL OF QUANTITY - D (AUDIO & STAGE LIGHTING WORK)
249Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
250Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
251Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. G.I. pipes.
252BILL OF QUANTITY - E (AIR CONDITIONING WORK)
253SITC of ISO certified company made air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R-32/R-410A R-407 Green refrigerant comprising of single/twin Scroll / Rotary / Reciprocating type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system,with min 5 year OEM warranty both compressor and PCB , Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine isolation / disconnect switch, valves and accessories to inter conne ct compressor and condender including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L , U/V, phase reversal protection, single phase preventors etc complete as required. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2548.5 TR
25511 TR
25616.5/ 16.7 TR
257Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
2580.63mm (24 G)
2590.80mm (22 G)
2601.00mm (20 G)
2611.25mm (18 G)
262Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6\\" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .
263Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .
264Supply air grill with key operated volume control damper
265Return air grill without volume control damper
266Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steelscrews etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
267Supply Air Diffuser with Volume Control damper
268Return Air Diffuser without Volume Control damper
269Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/ R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, apable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll / reciprocating / rotary compressor with min 5 year OEM warranty both compressor and PCB as specified. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ERDA lab testing reports as per IS 1391 with OEM certificate mustsubmitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2701.5 Ton
2711.9/ 2 Ton
272BILL OF QUANTITY - F (ELECTRIC WORK)
273Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade ( IS: 694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it's all accessories, round tiles,18 SWG G.I.box with earth terminal, 6 A switch, 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet, pvc bushes, check nuts, Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. All as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
274Short point (up to 3 mtr.)
275Medium point (up to 6 mtr.)
276Medium point (up to 10 mtr.)
277Wiring of twin control light / Fan / Call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it's all accessories, round tles, 2 Nos 18 SWG G. I. box with earth terminal, 2 Nos 6 A two way switch, 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenoliclaminated sheet,pvc bushes, check nuts, Al. alloy/ cadmium plated iron screws 20 mm cup washers etc , All as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
278Short point (up to 3 mtr.)
279Medium point (up to 6 mtr.)
280Medium point (up to 10 mtr.)
281Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it's all accessories, required size 18 SWG, G.I. box with earth terminal, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet,pvc bushes, check nuts, Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
282On board
283Short point (up to 3 mtr.)
284Medium point (up to 6 mtr.)
285Long point (up to 10 mtr..)
286S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit of apropriate thickness related to its dia as per PWD specification for electrical Works along with accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required including cutting the wall and making good the same as required all as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
28720 mm
28825 mm
289Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
2903x 1.5 sq.mm
2914 x 1.5 sq.mm
2922 x 2.5 sq. mm. + 1x1.5sqmm
2934 x 2.5 sq.mm
2943 x 4 sq. mm.
2954 x 4.0 sq.mm
2962 x 6.0 sq.mm
2974 x 10.0 sq.mm
2984 x 16.0 sq.mm
299Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped & confirming to latest TEC specification , GR / WIR/06-03 March 2002 of following pair in existing surface or recessed PVC/MS conduit/casing capping including all as per pre approved by Engineer in charge, making connections, as required. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
3002 pair
3014 pair
302Jelly filled armoured (PIJF)
30320 pair
304roviding & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP20 contact protection and fitted with existing distributionboard/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
305Single pole MCB
3066 A to 32 A rating
307Double pole MCB
3086 A to 32 A rating
30950-63 A rating
310Triple pole MCB
3116 A to 32 A rating
31250-63 A rating
313Four pole MCB
3146 A to 32 A rating
31550-63 A rating
316Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection as per PWD specification for electrical Works with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, true position indication and trip free mechanisum, line load reversibility, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 80 A-100 A rating,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
317Two pole 30 mA sensitivity
3186-32 A rating
31940 A rating
320Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet,including making internal DB terminations with copper lugs and withdetachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
321IP-43 Double door (single phase)
3228 Way (8 O/G +2 I/C )
32312 Way (12 O/G +2 I/C)
324IP-43 Double door (Three phase)
3258 Way ( 24 O/G + 8 I/C )
32612 Way ( 36 O/G + 8 I/C
327Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA ) powed coated enclosure as per PWD specification for electrical Works conforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR
328Single phase (Three pin)
329Three phase (Five pin)
33030A-32A
331Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet,including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
332IP-43 Double door (Three phase)
3338 Way ( 24 O/G + 8 I/C )
334Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR
3352 pin Telephone socket Group A
336RJ-45 computer jack with shutter
337LED Skirting /Foot Light 2/3 Module
338Blanking plate
339Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
3401/2/3 Module
341Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
3421-2 Module
343SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR
344With Thermal Magnetic Release
345up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Ic
346Providing and laying XLPE/PVC insulated & PVC sheathedarmoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering
3472C x 2.5 sq.mm
3484C x 2.5 sq.mm
3496C x 2.5 sq.mm
3508C x 2.5 sq.mm
351Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
3523 core 240.0 Sq.mm
353Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009
3541 sq.mm
3554 core
356Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
357Indoor
3583 core 240/300 Sq.mm
359Outdoor
3603 core 240/300 Sq.mm
361Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
362Mild Steel
363150mm x 50mm x 1.6mm
364300mm x 50mm x 1.6mm
365450mm x 50mm x 2.0mm
366upplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional echnical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR
3676.0 Sq.mm 2 core
3686.0 Sq.mm 4 core
36910.0 Sq.mm 4 core
37016.0 Sq.mm 4 core
37135.0 Sq.mm 3.5core
37250.0 Sq.mm 3.5core
37370.0 Sq.mm 3.5core
37495.0 Sq.mm 3.5core
375150.0 Sq.mm 3.5core
376240.0 Sq.mm 3.5core
377300.0 Sq.mm 3.5core
378Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
379Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
380Plate Earthing as per PWD specification for electrical Works as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
381Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
38210 SWG G.I. Wire
383Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
38430mm x 5 mm copper strip
38532mm x6mm G.I. ( Hot Dipped ) Strip
386Fixing of fresh air fan/exhaust fan up to size of 300 mm on pl y/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
387Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
388With regulator
389Providing & Fixing of ISO Certified company made BEE Approved copper wounded 1200 mm sweep BLDC technology power saving ceiling fan with longer life span and low maintenance 5 star rated which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 215 CMM, speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod up to 30 cm with secondary support safety cable , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
390Without Remote
391P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
392Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
393300 mm sweep
394roviding & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
395450 mm sweep
396Providing & Fixing of heavy duty, copper wound , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade wall mounting oscillating type air circulator as per PWD specification for electrical Works, conforming to IS:2997, including fixing with anchor bolts, regulator making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
397450 mm sweep With wall Mounting and three speed regulator
398Providing & Fixing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy min. 100 lm/watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\"attacheded with this BSR
399LED Downlight 9/10W
400LED Downlight 14/15W
401LED Downlight 18/20W
402Providing & Fixing of IP20 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System Lumen efficacy min. 100 lm/watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR
40336W LED light fixture 2'x2' with acrylic / prismatic front cover
404Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR
4054' LED Tube shape fixture 18/20 W (Polycarbonate Base)
406P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Power consumption of 10-15W , 500-600 lumens system lumen efficiency 70 lm/ watt output suitable for1x100 W GLS/9W CFL bulk head fixtures, life time of 50000 burning hourswith 70% initial lumen maintained. CCT 3000° K,4000° K and 6000° K. Fixture shall be incompliance with CE & KEMA standards
407LED Bulk head luminaire 9/10W
408Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BS
409Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.)
4105.0 Mtr.
411Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , Driver Current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixtureshall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. M79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
412High power LED flood light 80 watt
413P & F of IP68, IK10 protected LED Buried marker light /Step Light Fixture. Fixture made of powder coated die cast aluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumensmaintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards
414urial Light - 5W L-7 MODEL
415Rectangular LED Marker Light
416Providing & Fixing of ISO certified company made IK10 IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current <1000mA shown in LM79 report. Fixture must be in compliance with BIS Standards and T.C . Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
41745 W LED Post Top Fixture
418External Electrical Work (Substation Equipment)
419EXTERNAL LIGHT FEEEDER PILLAR
420SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
421SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
422Electrolytic grade Aluminium bus bar 6010 grade
423Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
424C T Class 1, Ratio upto 150/5, Burden 5 VA
425Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
426Red/yellow/Green colour
427Blue / white Colour
428Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
429Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
430SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
431With Thermal Magnetic release
432upto100Amp,25kA,adjustableO/L&fixedS/Csetting,Ics = 100 % Icu
433Providing&Fixingof240/415VACMCBwithpositiveisolationofbreakingcapacitynotlessthan10KA(B/Ctrippingcharacteristicaspertypeofloadandsiterequirement)4KVimpulsewithstandvoltage,asperPWDspecificationforelectricalWorkswithISImarkedIS8828(1996)/conformingtoIEC60898-12002,IEC60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof35sq.mm.,conductorlineloadreversibility,labelholdingfacility,IP20contactprotectionandfittedwithexistingdistributionboard/sheets,min.operation20,000upto32Aratingand10,000upto63A,5000for80Aratingincludingmakingconnections,testingetc.asrequired..OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtestreportsbeforeexecution&AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
434Four pole MCB
4356 A to 32 A rating
436MAIN L.T PANEL
437SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
438SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
439Electrolytic grade Aluminium bus bar 6010 grade
440Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
441C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
442C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
443Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
444Red/yellow/Green colour
445Blue / white Colour
446Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
447Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
448SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
449With Thermal Magnetic release
450630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, Ics = 100% Icu (Buscoupler)
451400 Amp ,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu (Incomer)
452250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Incomer)
453200 Amp , 35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Outgoing)
454200 Amp , 35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Outgoing)
45550KVAR APFC PANEL
456SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
457SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
458Electrolytic grade Aluminium bus bar 6010 grade
459Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
460C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
461Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
462Red/yellow/Green colour
463Blue / white Colour
464Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
465Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
466SITCofIP40quickmakeandquickbreak3polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
467With Thermal Magnetic release
468200 Amp , 35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Outgoing)
469up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100% Icu (Outgoing)
4703 pole Power contactors with following AC 3 Rating
47113 to 25 Amp
472Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
473up to 6 kVar
474MAIN BUILDING L+P PANEL
475SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
476SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
477Electrolytic grade Aluminium bus bar 6010 grade
478Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
479C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
480Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
481Red/yellow/Green colour
482Blue / white Colour
483Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
484Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
485SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
486With Thermal Magnetic release
487250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Incomer)
488up to 200 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100% Icu (Outgoing)
489MAIN HVAC PANEL # 1
490SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
491SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
492Electrolytic grade Aluminium bus bar 6010 grade
493Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
494C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
495Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
496Red/yellow/Green colour
497Blue / white Colour
498Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
499Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
500SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
501With Thermal Magnetic release
502250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Incomer)
503up to 200 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100% Icu (Outgoing)
504MAIN HVAC PANEL # 2
505SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
506SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
507Electrolytic grade Aluminium bus bar 6010 grade
508Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
509C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
510C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
511Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
512Red/yellow/Green colour
513Blue / white Colour
514Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
515Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
516SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
517With Thermal Magnetic release
518250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Incomer)
519up to 200 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100% Icu (Outgoing)
520MAIN HVAC PANEL # 3
521SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:-(a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear[c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (>125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure \\"A\\" attached with this BSR .
522SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwiththisBSR .
523Electrolytic grade Aluminium bus bar 6010 grade
524Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
525C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
526Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\\"A\\"attachedwith this BSR .
527Red/yellow/Green colour
528Blue / white Colour
529Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
530Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .
531SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure \\"A\\" attached with this BSR .
532With Thermal Magnetic release
533250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu (Incomer)
534up to 200 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100% Icu (Outgoing)
535Supply installation testing & Commissioning of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+5% to - 10% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953 , Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
536100 KVA
537BILL OF QUANTITY - G (CCTV WORK)
538Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at bothends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
539Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper in plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR.
540Cat 6A, Sheilded Information Outlet
541Supply & fixing of square Faceplate for Flush / Surface Moun Information Outlets Single/Dual or Quad Aperture , material shouldbe PC+ABS body, Suitable for RJ45 unshielded/shieldedconnection modules. Should match with I. O. OEM. Dimensionsshould be 86mm X 86mm as required complete in all respect. Aas per pre approved by Engineer in charge. For additional technicaparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR
542Single Aperture
543Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, 24 Port Unloaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels (without I.O.) with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel, . There should be a provision for each port/jack on the panel and reusable removable on field from the panel complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
544Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
545Multi Mode LIU 24 Ports
546Supply , Installation, Testing and Comissioning of Managed Layer-2Intelligent Giga Ethernet Switch providing 24 x 10/100/1000 MBPSGiga Ethernet ports and with min 4 SFP Giga Ports (provision foFiber Giga connectivity) with provision of minimum Stacking of 06Switches with related LAN Base Software including makingconnections etc as required complete in all respect complete in arespect. All as per pre approved by Engineer in charge. Foadditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR .
547BILL OF QUANTITY - H (HORTICULTURE WORK)
548Trenching in specified soil upto a depth of 60 cm. including removal and stacking of serviceable materials and then disposal by spreading and neatly leveling within a lead of 50 metres and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and farm-yard manure before and after flooding with water (excluding cost of imported earth and sludge or farm-yard manure).
549Preparation of mounds of various size and shape by available excavated/surplus/earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc.lead upto 50 meters and lift upto 1.5 m as per direction of officers in charge.
550Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead.2) Earth measured in stacks will be reduced by 20% foe payment
551Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking.
552Rough dressing the trenched ground including breaking of clods.
553Fine dressing the ground.
554Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately).
555Grassing with 'Carpet' grass (selection no. 1) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.(The good earth shall be paid separately) In rows 5 cm apart in either direction
556Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking, clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
557Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart.
558Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
559Plumeria alba ( Champa)
560Neem(Azadirachta indica)
561Bottle Brush(Callistemon Lanciolatous)
562Morning glory (Ipomea)
563Supply and planting following species best quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes, 1.20 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
564Gulmohar(Delonix regia)
565Jacaranda mimosifolia (Neelli Gulmohar)
566Providing and fixing of RCC pre cast tree guard consisting of four panels of size 1800mm (Height) X 600mm (Width) X 35mm (thickness); Size of opening: 100mm X 100mm. All the panels shall be manufactured with monolithic legs of size 50 x 35 mm; the legs of the panels shall be 0.5 m below ground level. All the four Panels shall have a space for display of Name etc. preferably at middle level. RCC panels to be manufactured with M-30 grade of concrete using vibro-compaction process using jointless FRP moulds so as to achieve shuttering finish. RCC panels are to be suitably reinforced to promote long use and to prevent damage during handling, transportation & erection as per drawing & specifications.
567Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc.
568BILL OF QUANTITY - J (FIRE FIGHTING WORK)
569Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised Fire authority approved Electric Driven Main fire pump for Sprinkler / Hydrant applications suitable for automaticoperation.consisting of following details given as A, B, C, D, E,F,G and H.
570Horizontal Single / Multi stage Centrifugal End suction, back pull out type pump complete for delivery of below mentioned discharge ,including bypass arrangement for Testing of pump
571Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal
572Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head
573Squirrel cage induction motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 suitable for 3 phase, 415 V, 50 HZ, Ac supply 2900 / 1450 RPM T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible coupling , coupling guard complete in all respect .
574Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads.
575Pump must be inspected by third party like RITES / PDIL at manufacturer's premises and inspection report is to be submitted.
576Suitable cement concreat foundation (1:3:6) duly plastered with (1:4) ratio
577All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
5782280 LPM suitable for 70 Mtr Head, single stage, 2900 RPM
579Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised fire authority approved Diesel Engine driven Pump suitable for automatic operation as per discharge defined beolw consisting of the following details given as A, B, C, D, E ,F and G
580Horizontal Single / Multi stage Centrifugal End suction, back pull out type pump complete for delivery of below mentioned discharge,including bypass arrangement for Testing of pump
581Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal
582Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head
583Radiator cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length (with insulation & Cladding), with muffler, day oil tank of 300 Lts capacity with piping.
584Pump is to be inspected by third party like RITES / PDIL at manufacturer's premises and inspection report is to be submitted.
585Suitable cement concreat foundation (1:3:6) duly plastered with (1:4) ratio
586First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by departmentAppropriate OEM/ NABL lab test reports shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
5872280 LPM suitable for 70 Mtr Head, single stage, 1800 RPM
588Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised fire authority approved Horizontal single stage Jockey pump with CI Body, Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 for automatic operation suitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed plate fabricated from mild steel channel Suitable cement concreat foundation duly plastered with anti vibration pads.complete in all respect. Appropriate OEM/ NABL lab test reports shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
589180 LPM suitable for 56 Mtr
590Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised fire authority approved single stage Centrifugal End suction, back pull type Terrrace pump with Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cageinduction motor (IE-2 class) for automatic operation suitable for three phase, 415 V, 50 Hz AC supply ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed plate fabricated from mild steel channel ,Suitable cement concreat foundation duly plastered with anti vibration pads.aincluding cost of suitable rating Control panel as per rating of Motor with 4 pole MCB, automatic DOL starter, Single phase Preventor , overload protection rely, contactors, MCBs , interlocking wiring , ferruling, potential free contact etc complete in all respect. Appropriate OEM/ NABL lab test reports shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
591450 LPM with 35 mtr head
592Providing & fixing 100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 \\" BSP bottom entry on Pump Delivery Line complete with Ball valve complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
593Supplying, Installation, Testing & Commissioning of pressure switches for Main, Jockey, Terrace pump and standby Diesel pumps, including necessary control wiring From pressure switch upto control panel and Ball valve complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
594Providing & fixing vane type water flow switches with contacts for installation in 50 mm to 150 mm dia M.S. pipe for a service pressure up to 20 Kg / Sq.cm complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
595Supplying, Installation, Testing & Commissioning of floor mounted dust and vermin proof compartmentalised cubical type main fire pump control panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mmlength / width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors and having accessories/ switch gear (as per Specf Ch-06 & 08) as below:- complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure \\"A\\" attached with this BSR .
596Incomer
597400 Amp. TPN MCCB (adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps, 500 Amps FP Alum. Bus bar with with heat shrinkable sleeves.
598Out going
599200 Amp. TPN MCCB(adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps for 'ON', 'OFF', 'TRIP' 1 no. DOL Starter of rating upto 75 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 2 Sets
60063 Amp. TPN MCCB (adj.O/L) with Extended ROM, 16 kA, with Thermal magnetic release, Digital Ammeter, Voltmeter, Selector switches, CT, Indicating Lamps for 'ON', 'OFF', 'TRIP' 1 no. DOL Starter of 5 - 15 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 1 Set
601One no. Diesel Engine Auto Starting kit with Auto Manual selector switch & 3 attempt starting device, timers, relays, Indicating lamp for High / Low Lub. Oil pressure, High water temperature and engine ON indication, DC ammeter & voltmeter
602System controller to control Operation Main Electric pumps, Diesel pump, jockey pump in sequence consisting of relays, timers, sensors, annuciation window for fault indication.
603Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted.
604Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories fromOEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
60540 mm dia
60650 mm dia
60780 mm dia
608100 mm dia
609150 mm dia
610Supplying and fixing cylindrical air vessel of continuous welded construction fixed at riser top made of 250 mm dia, fabricated out of 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia drain valve,release valve,safety valve pressure gauge with required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
611Supplying and Fixing of Y type strainer fabricated out of cast iron/ steel body, strainer shall have 1.6 mm. thick stainless steel sheet perforated screen with 3 mm. dia holes with flange at both ends complete with nuts, bolts, washers, gaskets etc of following sizes. complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
612150 mm dia
613Providing and constructing masonry chamber 90 x 90 x 100 cms inside with brick work in cement mortar 1:5 (1cement : 5fine sand) for water meter ,M.S. cover (6mmthick sheet with locking arrangement, 600 x600 with M.S. frame etc. all epoxy coated and R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarsesand : 4 graded stone aggregate 20mm nominalsize) including necessary excavation, back filling foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 20mmnominal size) leaving a pocket of 30x30 cmwith out concrete and filled with pebbles andinside plastering with cement mortar 1:4 (1 cement : 4 coarse sand) 12 mm thick finishedwith a floating coat of neat cement and outside plaster finished rough complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
614Supply, installation, testing and commissioning of dual plate nonreturn valve (PN-16) of following sizes confirming to IS:5312 -1975 complete with flanges,rubber gasket, nut,bolts, washers etc.complete in all respect. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
615100 mm dia
616150 mm dia
617Supplying, fixing, testing commissioning of butterfly valve (PN 16) with Bronze/ Gunmetal seat duly ISI marked conforming to IS 13095-1991 complete with flanges,Nuts, Bolts, washers, gaskets of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
61880 mm dia
619100 mm dia
620150 mm dia
621Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
62232 mm dia
62350 mm dia
624Providing & fixing testing & commissioning of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 150 mm dia as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
625Providing, Fixing, Testing & Commissioning of single headed obligue pattern hydrant landing valve (internal/external) ISI marked confirming to IS:5290-1983 (Type-A) /IS: 908 - 1975 with 80 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with cap and chain, twist release type plug and all accessories complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
626Stainless Steel (SS 316) material
627Supplying and fixing of Non-percolating flexible hose (RRL type-A) ISI marked confirming to IS:636, 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia male and female couplings (Confirming to IS:903) duly bound and riveted to hose pipes with copper rivets and copper wire etc. as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR .
628With Stanless steel Coupling
629Supplying and fixing first -Aid Fire hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.
63030 m long 20 mm (nominal internal) dia water hose
63120 mm (nominal internal) dia gun metal globe valve & nozzle 5mm orifice
632Drum and brackets for fixing the equipments on wall.
633Connections from riser with 25 mm dia stop valve (gun metal) & M.S. pipe complete in all respect.Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR .
634with High Pressure Braided Rubber Hose as per IS:5132 - 1969
635Supplying and fixing Fire Brigade In let Connection of CI body with Gun Metal/stainless steel male instantaneous inlet couplings complete with PVC blank cap and chain as required for 150mm dia MS pipe connection, conforming to IS 903 as required of following way :- complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
6362 Way
6374 Way
638Providing and fixing of Gun Metal/stainless steel Fire brigade Suction hose coupling (draw out connection) with nut for female coupling as per IS:902-1974 complete with 100mm dia valve, complete with nut bolts and rubber insertion complete as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
639Supplying and fixing of Hose Cabinet made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos 15 Mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for internal/external hydrant complete as required. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
640size 750 mm x 600 mm x 250 mm
641Providing & fixing of size 0.9 M wide x 1.8 M height Indoor Hose Cabinet shutter suitable for accomodating hydrants made of Tubular rectangular pipe (50X25mm) having central opening 6mm thick glass glazed door having necessary locking arrangement, painting (one coat primer & two coats of paint) suitable for housing 2 Nos. RRL hose pipe, 1 no branch pipe, first Aid hose Reel etc . as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR
642Providing, fixing, testing & commissioning of 15 mm dia size quartzoid bulb type sprinkler heads suitable for 68 degree centigrade rating standard response (UL/FM/LPC/TAC Listed/Approved) chrome plated complete in all respect of the following type complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
643Pendant/ Upright type
644Sidewall Sprinklers (ordinary)
645Providing, fixing, testing and commissioning 25mm diameter inspecting and testing assembly with gunmetal isolation valve gunmetal sight glass bypass valve and connected to 50mm drain line complete as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .
646SITC of UL 10th edition / EN54 VDS approved IP40 Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm ) type Photo smoke detector with mounting base & LED etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR .with inbuilt isolator or with isolator base
647SITC of IP40 Analouge Addressable type Heat Detectors (Thermal Detectors): GRADE-I with solid state design with sensing element combination of fixed type and rate of rise of temperature mounting base & LED shall have UL 10th edition / EN54 VDS approved certification etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR with inbuilt isolator or with isolator base
648Supply installation testing and commisisioning of IP 40 Beam detector along with Addressable interface module having a coverage area with a distance of min. 10 m and max. 100 m, Operating temperature range: -20 C to +55 C, Response sensitivity of 40%, shall have UL/EN54 certification including transmitter and receiverunit with mounting base & LED etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
649Supply, Installation, Testing and Commissioning of IP 40 Stand alone Loop Powered Addressable sounder with 5 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 90 dB , it should be programmed from the panel. Shall have EN54 /UL Certification including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .with inbuilt isolator or with isolator module
650Supply, Installation, Testing and Commissioning of IP52 Addressable (MCP) Manual Break Glass/ flap Unit (Double action) shall have UL/EN54 certification shall be constructed of Lexan with clearly visible operating instructions provided on the cover. The word FIRE should appear on the front of the stations in raised letters, including the cost of all ccessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
651with inbuilt isolator or with isolator module
652SITC of Response Indicator for addressable type detectors as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure \\"A\\" attached with this BSR .
653Supply installation testing and commisisioning of Addressable control (input/output) modules/ Relay Module for shutting down lifts, AHU's, Acknoledgement of Sprinkler system etc. with potential free contact monitoring Shall have EN54 /UL Certification. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
654with inbuilt isolator or with isolator module
655Supply, Installation, Testing and Commissioning of Microprocessor based inteligent, Analogue addressable fire alarm panel with CPU redredundancy & min 640 charactor/ 6\\" touch screen display , shall have UL 10th edition / EN54 VDS approved certification, modular,expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 250 detectors & devices with Loop length up to 1.5 KM. Minimum 5000 history event facility . Panel shall be Compatible for Seamless integration with PA system and both system should be of the same make. The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, inbuilt networking port (both RS485 & Ethernet),Serial port for printer, two supervisory inputs,two position key switch and USB port for programming. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
6562 - Loop Panel
657Supply , installation testing and commisioning of EN-54 Certified IP based PA controller capable of adding 12 ZONE and expandable upto 50 zones with full digital functionality same with FACP OEM, it shall contain 12 speaker line outputs. 5000 fault warning and event conditions log. Built in message manager for 60 emergency/ business calls up to 60 minutes. It also contains EN-54 certified Call Station with extension keypad to serve minimum 12 zones, gooseneck microphone with supervised electret microphone, integrated loudspeaker for system sounds, customizable function and speed dial buttons. Possible to use keys (push buttons) for Zone select, source select, level control, emergency on/off, message on/off, failure acknowledge/reset. Call Station is completely supervised by system controller. Power Amplifier of 480 W in a 3U high housing with 70 V / 100 V and 8 ohm outputs,Dual inputs with priority switching,100 V input for slave operation on 100 V speaker line, Mains, battery back-up, including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect.OEM appropriate test certificate shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
658Supply, installing,testing & commissioning of PA system Operator Console of following wattage to be installed with Conventional fire alarm system complete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
6591x 240 Watt
660SITC 6 watt Speaker mounted in M S sheet box with perforated front mesh for PA and Emergency System complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
661Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
662Supply & Fixing of ISI marked conforming to IS : 2878 Fire Extinguisher, Trolley mounted, CO2 (gas pressure) type capacity 22.5 Kg. with gun‐metal cap.delivery hose horn, trolley, handle, wheel type release valve, locking arrangement complete in all respect. bidder must have valid PESO license to refill and store compressed gas cylinders as per Gas Cylinder rules 2004 , vessel should be PESO Approved. carbon dioxide gas shall conform to IS 15222 with latest amendment. Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
663Supplying and Fixing of fire bucket stand made out of MS angle with one coat of primer and two coat of enamel paint of approved shade including platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters \\"Fire\\" in black and gold as per IS 2546-1974 at approved location as per direction of Engineer incharge complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
664Providing, Fixing, of Photo luminescent Self charge EXIT Sign boards of approximate size 12\\" x 6\\" The colour combination and letter size shall be in accordance with IS: 9457-1980, IS: 12349- 1988. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR .
665CIVIL WORK
666Providing & Fixing Red sand Stone Chhatri
667Solid fire rated steel doors are made up of 1mm thick GI sheet, BS-476 part 20-22 (1987) IS 3614 Part-2 1992 Door leaf 45 (+-1) mm thick and door frame of 1.5mm thick GI sheet, with Rockwool (Density 96 kg/m3) as infill material with Polyester Powder Coating of 60 to 80 microns (Max Jamb of frame will be 100x55mm and frame construction will be of single rabate. All doors shall be factory prepared and with necessary reinforcement for Hinges, Lock, Door closer and all the eages interlocked. (including all hardware, fixing, fire rated clear glass of 200 x 300mm, flush bolt, anchor fastner of Hilti make) including fixing and supply. Make - Ozone, Saint Gobain or Equivalent) - Single leaf Fire Shaft Door (0.6 x 2m)
668Solid fire rated steel doors are made up of 1mm thick GI sheet, BS-476 part 20-22 (1987) IS 3614 Part-2 1992 Door leaf 45 (+-1) mm thick and door frame of 1.5mm thick GI sheet, with Rockwool (Density 96 kg/m3) as infill material with Polyester Powder Coating of 60 to 80 microns (Max Jamb of frame will be 100x55mm and frame construction will be of single rabate. All doors shall be factory prepared and with necessary reinforcement for Hinges, Lock, Door closer and all the eages interlocked. (including all hardware, fixing, fire rated clear glass of 200 x 300mm, flush bolt, anchor fastner of Hilti make) including fixing and supply. Make - Ozone, Saint Gobain or Equivalent) - Double leaf Fire Door (2.1 x 2.4m)
669Providing and fixing to existing door frames 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm ± 0.2 mm with inbuilt decorative moulding edging on one side. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm ± 0.1 mm wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
670Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazing bead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware: Each openable door shutters is to be fixed with three load beading butt hinges and locking of doors is to be provided with multi-point transmission gear (ESPAG) with white finish powder- coated lockable handle. Installation at site: Complete door is to be installed on site with 10 X 100mm fastners with white cap in existing prefinished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and door frame. Complete in all respect as per the drawing and specification and direction of engineer-in-charge.
671Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with „K‟ & „O‟ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height &
672Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, White in finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co-extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour
673Providing and fixing Toughened glass 12mm thickness including supply of all material, labour, T&P, etc. required for proper completition of work as per direction of Enginner-In-Charge.
6748 mm dia C.P. Brass/ S.S. Jet with flexible tube upto 1 metre long with S.S. tringular plate for Eureopean type W.C.
675SITE DEVELOPMENT WORK
676Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with „K‟ & „O‟ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height &
677SUB HEAD - INTERIOR WORK
678Providing and fixing of upholstered rana chairs, centre-to-centre 535-550mm Approx. & back-to-back 950-1000mm Approx. (as per site condition) having flexi back mechanism with complete powder coated framework and with inherently fire retardant fabric complete with all accessories and fixing with four number anchor fasteners of Hilti/Fischer make. Seating to be fixed as per layout in design drawing. Complete as per specifications, Sample Chair needs to be approved for type, comfort and fabric color prior to supply by the Acoustic Consultant and the client. All material to be approved by the Acoustic Consultant/Architect prior to installation.
679Fabric Wrapped Panel 595x595x10mm, Square edge (T15 Grid system) -- Hall and below balcony false ceiling
680Supply and Installation of Gattone Fabric Wrapped square edge Panel, panels of size 595x595x10mm, density 200kgs/m3, which is suspended by using 0.3mm thick gattone T15 metal grid system.
681T15 metal grid system of 600x600mm module includes wall angle with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally crossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CrossT in direction parallel to the Main T15 to result in 600x600mm module. Gattone fabric wrapped panel of size 595x595x10mm shall be placed into the grid size of 600x600mm.
682The system is backlined with the acoustical polyester 50/1000 kgs/m3
683Technical Parameters
684• Fire (Class) – ASTM E84 CLASS A• Acoustics – NRC 0.9• Thermal conductivity (W/mk)– na• VOC Emission- ASTM D5116 Rate:<0.2mg/m2/hr(7 Days) • Light reflectance (%) – 35%• Green - Asbestos-free,non-toxic and tasteless gas under extreme temperature
685Wood Fibre Tile 1195x595x15mm, Square edge
686Supply and Installation of false ceiling 15 mm thick Mat Black Gattone magnesite bonded panels made with superfine wood fibres & gypsum, were patented with magnesite cement, edge profiles of size1200 x 600 mm laid over MS Suspension Grid consisting of 2 nos 40 X 40X 5mm MS Angles and TEE welded back to back one side @1200mm c/c & other side @ 600mm c/c .
687MS grid system of 1200x600mm module includes wall angle with flanges of 40mm, length 3000mm, fixed along the perimeter of walls with the help of suitable fasteners at 300mm centers. Then suspend the MainT with flange width 40mm, height 40mm and length as per requirement from the soffit slab with help of neccessory screw or fabrication and 35x5mm flat with leveling at 1200mm centres. CrossT with flange width 40mm, height 40mm and length 1200mm is interlocked with fabrication at 600mm centers in the perpendicular direction to the Main Tee. Finally CrossT with flange width 40mm, height 40mm and length 600 and 1200mm are join both the direction parallel to the Main Tee to result in 1200x600mm module. Gattone Tile of size 1195x595x15mm shall be placed into the grid size of 1200x600mm.
688Technical Parameters
689• Fire (Class) – BS 476 PART 5 AND 6• Acoustics – NRC 0.8• Water Resistance - IS3308• Climate (°C, RH) – 60, 90• Density(kg/m3)- 400• Wood Fibre- 1mm width with magnesium
690Wall Paneling
691Panel Size 09mm as per Design, Square edge -- Hall
692Supply and Installation of FR grade gattone 9mm thick non wooven composite panel.
693The panel of 9mm thick non wooven composite panel by using 12mm thick BWR PLY. GI frame work of 48mm GI Studs using 0.5mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh as per detailed drawing. The frame work to be filled with non wooven polyster wedding(Novofill) of 50mm thick of 1000gsm. After that install the 12mm BWR Ply with help of gypsum screw as per requirement. And fixing of Panel with help of adhesive. Fire Retardant as per ASTM- E84. The product is light weight, with a density of 218 kg/m3. No odor, Formaldehyde free and a smoke development index of 300 by ASTM –E84. Any Undulations in the Walls to taken care by the Interior Acoustics Contractor for proper packing. - NRC upto-0.9
694Technical Parameters
695• Fire (Class) – ASTM E84 CLASS A• Acoustics – NRC 0.9• Thermal conductivity (W/mk)– na• VOC Emission- ASTM D5116 Rate:<0.2mg/m2/hr(7 Days) • Light reflectance (%) – 35%• Green - Asbestos-free,non-toxic and tasteless gas under extreme temperature
696Envirotech Panel 192x2400x15mm - Wall Lining Hall
697Supply and Installation of envirotech Channelled Wood works perforated panels of width 192mm, thickness of 15mm and length 2440 mm or as per site requirement, made of a medium density fibre board with minimum 800 Kg/M3 density substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The panels shall provide a fire reaction of Class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation alongwith G.I framework of 48mm GI Studs using 0.5mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to be filled with gattone non wooven polyster wedding of 50mm thick of 1000gsm . The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC upto 0.85. The panels shall be mounted on special aluminium splines using clips approved by the client.The contractor should submit shop drawing before execution, if asked by the Engineer. Any Undulations in the Walls to taken care by the Interior Acoustics Contractor for proper packing.
698Technical Parameters
699• NRC- upto 0.85• Fire – 1&P• Climate (OC RH) – 50,90• Termite resistance – Yes• Light reflectance – 85 %• Green (RC %) – 30• Hygiene (VoC, Clean room) – Low, Class 1
700Gattone Panel 600x1200x09mm, - Stage
701Supply and Installation of FR grade gattone 9mm thick non wooven composite panel.
702The panel of 9mm thick non wooven composite panel by using 12mm thick BWR PLY. GI frame work of 48mm GI Studs using 0.5mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh as per detailed drawing. The frame work to be filled with non wooven polyster wedding(Novofill) of 50mm thick of 500gsm. After that install the 12mm BWR Ply with help of gypsum screw as per requirement. And fixing of Panel with help of adhesive. Fire Retardant as per ASTM- E84. The product is light weight, with a density of 218 kg/m3. No odor, Formaldehyde free and a smoke development index of 300 by ASTM –E84. Any Undulations in the Walls to taken care by the Interior Acoustics Contractor for proper packing. - NRC upto-0.9
703Technical Parameters
704• Fire (Class) – ASTM E84 CLASS A• Acoustics – NRC 0.8• Thermal conductivity (W/mk)– na• VOC Emission- ASTM D5116 Rate:<0.2mg/m2/hr(7 Days) • Light reflectance (%) – 35%• Green - Asbestos-free,non-toxic and tasteless gas under extreme temperature
705BILL OF QUANTITY - D (AUDIO & STAGE LIGHTING WORK)
706SITC of Array Loudspeaker for FOH Left & Right Acoustical specifications, Frequency Response(-3db):LF: 90Hz-4kHz; HF: 900Hz-15kHzMax SPL @1m:LF:131dB/137dB(PEAK); HF:134dB/140dB(PEAK)Dispersion (H x V):LF: 110° x 90°; HF: 90° x 20°, Transducers Compression driver:2 x 3\\" HFWoofer:2 x 12\\" LF, Input/Output section, Input Connectors:2 x NL4 @ LF:1+ 2- HF: 3+ 4-Sensitivity (1W @ 1m):LF: 102dB; HF: 110dB, Power section, Total Power:LF: 500W, HF: 100W(RMS); LF: 1000W, HF: 200W(MUSIC); LF: 2000W, HF: 400W(PEAK);Nominal Impedance (Ohm):8Ωired in parallel for IN/THRU use as complete
707Supply and fixing of Rigging Hardware/ Bracket: Aluminum array frame for enclosures.
708SITC of Subwoofer transducers Low Frequency : Dual 18\\" Cone transducer, Frequency Range (-10 dB) : 35 Hz - 100 Hz, Amplifier Power Output : 900W Class D continuous, Maximum SPL (@ 1 m) 134dB SPL
709SITC of Stage Monitors Transducers :Low Frequency : 12\\" Cone transducer & High Frequency 1.4 \\", Frequency Range (-10 dB) : 45 Hz - 20 kHz, Nominal Coverage Angle : 75° Axisymetric, Amplifier Power Output : Class D 1300W, Maximum SPL (@ 1 m) 130dB SPL, Configuration : Multi-purpose, 2-way powered loudspeaker
710SITC of Front Fill Speakers Transducers :Low Frequency : 8\\" Cone transducer & High Frequency 1.4 \\", Frequency Range (-10 dB) : 45 Hz - 20 kHz, Nominal Coverage Angle : 75° Axisymetric, Amplifier Power Output : Class D 1300W, Maximum SPL (@ 1 m) 130dB SPL, Configuration : Multi-purpose, 2-way powered loudspeaker
711SITC of Control Room & Green Room Transducers Low Frequency : 4.5\\" Cone transducer & High Frequency 1 \\" , Frequency range (-10 dB) : 70 Hz - 20 kHz, Nominal Coverage Angle : 120° Axisymetric Power handling : 50W or more Transfomer tap settings at 100V: 30, 15, 7.5 W and 8Ω bypass Maximum SPL (@ 1 m) 110dB SPL, Configuration : Multi-purpose, 2-way powered loudspeaker
712SITC of amplifier Professional Power AmplifierPower(4ohms): 2500W/CH, Power(8ohms): 1500W/CH, Input Sensitivity: 0.775V/1V/32dB Switchable, Frequency Response: 20Hz-20kHz ±2dB, S/N Ratio: >105dBTHD (@1kHz): <0.1% @8Ω, 1kHzIMD (@60Hz/7kHz 4:1): <0.5% @8Ω, 60Hz/7kHz 4:1Damping Factor: >500 @8Ω, 100Hz
713SITC of Analog Mixing Console, 32 imput (24 mic/line, 6 line, USB stereo), 16 output, LX7II include frame sizes up to 32 mono inputs and four stereo inputs/returns with four groups, main stereo output and a dedicated mono output for centre clusters. There are direct outputs on the first 16 inputs suitable for multitrack recording, and six auxes for flexibility, effects and foldback
714SITC of 12 Analog Inputs (with 48v Phantom Power per Channel), 8 Analog Outputs Configurable Signal Processing, Rich Palette of Processing and Logic Objects 48 Channel, Low Latency, Fault Tolerant Digital Audio Bus, Clear Front Panel LED Indication Bi-Directional Locate Functionality, 12 Control Inputs and 6 Logic Outputs for GPIO Integration, Soundweb London Interface Kit for Third Party Control System Integration (Documentation), HiQnet Device
715SITC of Hand Wireless Microphone, True diversity receiver with metal housing ,External antennas. Automatic frequency management and synchronization via ,remote channel for easy setup Fully tunable over a wide range of UHF frequencies ,Up to 16 compatible channels, Power supply 12 V DC nom. / 300 mA ,AF frequency response 50 to 16,000 Hz (–3 dB)
716SITC of Wireless Collar Microphone, Compact Collar microphone for high speech intelligibility and lightweight, bodypack transmitter, True diversity receiver with metal housing External antennas, Automatic frequency management and synchronization,via remote channel for easy setup Fully tunable over a wide range of UHF frequencies , Rackmount kit included Up to 16 compatible channels. Complete set with Receiver, Body Pack Transmitter and collar microphone
717SITC of Wired Microphone for General purpose Vocal/Instument with on/off switch
718SITC of Microphone Stand Floor/Table Tripod type
719Supply and laying of Two core 1.5sqmm speaker wire
720Supply and Laying of Two Core shielded Microphone cable
721Supply and Laying of Eight Core Microphone Snake Cable
722Supply and Fixing of Microphone Connectors Box with 6 Microphone Inputs and 2 Aux
723Set of connectors & Patch cables
724Supply and Fixing of Equipment rack 30 U with power strip, fan, doors, wheels, drawer for accessoories with lockable facility.
725STAGE LIGHTING & STAGE FURNISHING (B)
726SITC of 54x3W LED par light complete with 8- channel DMX 512, high brightness mixing color evenly, stable performance with sound active auto, DMX, and power and DMX loop in and out option, undergone through 7 Tank chemical treatment to keep them rust free and, duly powder coated in black matt texture finish and technical specifications as below. Lamp - 54 x 3W RGBW LED, Power consumption – 150W, Power supply - 230/240V AC, Power cable - 3 core 1.5 sq. mm. copper PVC insulated, Channels - 1 Channel DMX-512, Beam angle -25° (15°, 45° optional) Function Manual dimming, DMX modes of operation completeetc. as reqd.
727SITC of 200W LED Profile light 19 degree with below specifications :- Lamp Power : LED,200W Power Supply : AC 110-230V, 50Hz Focus : Manual Focus , Beam Angle : 19° ,Dimmer : 0-100% linearly adjustable manually focusable, high quality optical system, glass reflector. DMX Control protocol: DMX 512. , CRI : >90 , Dimming : 100 - 0% dimming • Control system : DMX,Auto run and master/slave, Working temp : 30-40 degree Celsius, Protection Rating : IP20 complete etc. as reqd.
728SITC of 200W LED PARCAN with below specification : Lamp power - 200W , LED Type: COB LED, Color Temperature 3200K Power Rating - IP 20 , Control Manual , DMX,Channels - 2 channel DMX 512 , Power Supply - 100-240 V AC, 50/60nHz complete etc. as reqd.
729SITC of 200W LED Fresnel spot Light with 200mm dia German Lens with belowspecification : Lamp power - 200W , LED Type : COB LED, Color Temperature 3200K ,CRI > 95, spot - Flood Focus adjustment : Mototrised, Beam angle - 10° - 50°Power Rating - IP 20 , Control Manual , DMX0-100% through manual and DMX , Channels - 2 channel DMX 512 , Power Supply - 100-240 V AC, 50/60Hz complete etc as reqd.
730Supply of LED Flasher Bar with power consumption of 100 W or better; Lamp : 18 RGB 10 Watt, Channel : 7 DMX; Control : DMX, Housing CRC sheet metal Holder 2 Nost, 2 mtr 3 core copper wire 3 pin plug top in all respect to approved makes.
731Supply of Moving Head/ SHARPY LIGHT 10R, Voltage: 110V~240V/50-60Hz, Ballast: Electronic ballast, Lamp: YODN 280W R10, Color temperature: 8500K, Life Span: 2000H, Colour Wheel: 14 Color + Blank Color Whee
732SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up of Aluminium or MS material Complete with black powder coating matt black finish.
733SITC of Digital Lighting Console with 96 DMX channels, 96 Channels. • 24 Fixtures. 24 Dimmer Control Channels. Time control of scenes: Fade in/out, 12 Faders for Control
734SITC of Opto isolated RDM enabled DmX splitter unit provided with 8 Isolated outputs Slow blow safety fuse 5 Pin XLR for output interface Dual mode to select 2 universe operation DmX Input through 5 Pin XLR Connector Powder coated compartment finish Mounting brackets for grid mount
735Supply and laying of FRLS Copper unarmoured Flexible cable having 3 Core each of 1.5 Sq mm size (In Mtrs)
736Supply and laying of FRLS Copper unarmoured Flexible cable having 7 Core each of 1.5 Sq mm size (In Mtrs)
737Supply and laying of 5 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmet DmX signal (In Mtrs)
738SITC of Set of connectors & Patch cables for entire job
739SITC of Main Motorized Curtain made of Velvet curtain (480 to 500 gram in 1 mtrs) cloth with harizontal sliding arrangements complete with fixing railling track, fixing brackets, runner, master runner, 3mm rope wire, 1HP Cropmton motor, drum with groove cutting, pulleys, 2 no air breaker switch (L&T, Siemens, GE make) for reverse & forward, 2 No. air micro switch for auto stop, 2 No push button for open/stop/close position. The curtain should be dropped to half area, when in closed position and minimum overlap at the centre should be 900mm and curtain should be stiched in double gathering cloth. Size (As per site Requirement)
740SITC of Rear/Back Motorized Curtain made of glazed cotton cloth with harizontal sliding arrangements complete with fixing railling track, fixing brackets, runner, master runner, 3mm rope wire, 1HP Crompton motor, drum with groove cutting, pulleys, 2 no air breaker switch (L&T, Siemens, GE make) for reverse & forward, 2 No. air micro switch for auto stop, 2 No push button for open/stop/close position. The curtain should be dropped to half area, when in closed position and minimum overlap at the centre should be 900mm and curtain should be stiched in double gathering. Size (As per site requirement)
741Providing and fixing of main curtain frill made out of double gathering glazed velvet cloth to be installed above the stage on 28mm dia GI pipe or GI channel.
742Providing and fixing of Rear/Back curtain frill made out of double gathering glazed Cotton cloth to be installed above the stage on 28mm dia GI pipe or GI channel.
743Providing and fixing of stage wing panel made out of 25 mm x 50 mm of 16 swg MS pipe duly painted in black colour with black glazed casement cloth both side having manual moving facility.
744Providing and fixing of Procenium made out from 50x50 mm M.S tube duly painted in black colour & 12 mm ply board, 25mm foam & Velvet/mossi cloth both side fixed on it. Size as per site requirement.
745BILL OF QUANTITY - E (AIR CONDITIONING WORK)
746Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
747Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50 mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610 mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc.complete as required and as per specifications.
748Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
749Fire damper
750Actuator
751BILL OF QUANTITY - F (ELECTRIC WORK)
752Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
7536.0 Sq.mm
7542 core
7554 core
75610.0 Sq.mm
7574 core
75816.0 Sq.mm
7594 core
76035.0 Sq.mm
7613.5core
76250.0 Sq.mm
7633.5core
764BILL OF QUANTITY - G (CCTV WORK)
765SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified.
766SITC of 2 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified.
767Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired.
768SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement.
769SITC of 42 inch full HD professional LED display for CCTV monitoring. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58082482
AUTHORITY Local Bodies
TENDER VALUE 14.63 Crore
LAST DATE 12-11-2026
Authority
Authority Name Department Of Local Bodies
Work Description Tender for Construction Of Town Hall At Sawai Madhopur
Basic Detail
Tender No 9622-01
Bidding Type Tender
Location
City Sawai Madhopur
State Rajasthan
Key Dates
Publish Date 16 Oct 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 14.63 Crore
Tender Fee 10000
EMD 29.26 Lakhs
Exemption Available
Document List
72e173e4-e4b1-4413-a8a9-e9a160639f3d.html
BOQ_1071718.xls
Tendernotice_1.pdf
TownHalldocuments.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

72e173e4-e4b1-4413-a8a9-e9a160639f3d.html

xls

BOQ_1071718.xls

pdf

Tendernotice_1.pdf

pdf

TownHalldocuments.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender