Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #58081081

Tender For Upgradation Of Play Fields Parks At Various Sports Complexes. Sub Head :Supply And Replacement Of Music/Sound System,Iei And Cctv System In Gym At Siri Fort Sports Complex.

Issued by Local Bodies · Delhi, Delhi
Tender Value
35.99 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
4 days left
EMD
71983
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Play Fields Parks At Various Sports Complexes. Sub Head :Supply And Replacement Of Music/Sound System,Iei And Cctv System In Gym At Siri Fort Sports Complex.

BOQ

Name of Work:- Upgradation of Play fields parks at various sports complexes. Sub Head :Supply and Replacement of Music/Sound System,IEI and CCTV system in Gym at Siri Fort Sports Complex.
Sl. No. Item Description
1MUSIC/PA SYSTEM Supply, Replacement including rebate of old items, Testing of 2x1200 watt Power amplifier (2 Channel of 1200 watt each) having of Multiple outputs - 2, 4, 8, 16 Ohms, 70Vrms, 100Vrms DSP – On-board Digital Signal Processor in each amplifier, Mains, battery back-up, and pilot tone supervision Temperature controlled forced front to back ventilation, directly stackable, Dual inputs with priority switching, Frequency response - (8Ω, 20Hz - 20kHz) (±0.25dB), Input Impedance: 10 kΩ balanced, 5 kΩ unblanced, Crosstalk: >80dB, Distortion - <5% at rated output power, 1 kHz, S/N (flat at max volume) i/c connection etc. complete as required.
2Supply, Replacement including rebate of old items, Testing of 300 watt amplifier with 6 mic/line inputs Inbuilt Bluetooth & USB input, Limiter circuit for protection, Insert feature to use as a pre/power amplifier, i/c connection etc. complete as required.
3Supply and Replacement including rebate of old items, of 150W Continuous Pink Noise PA Wall Speaker in High Impact Polystyrene (HIPS), painted with highly-UV resistant paint, loudspeaker shall consist of a 200 mm (8 in) low frequency transducer, 25 mm (1 in) compression driver, and frequency dividing network. The low frequency driver’s voice coil shall be 50 mm (2 in) in diameter.with broad frequency response of 45 Hz – 18 kHz. The speaker having arrangements of taping 150 Watt power handling (300 Watt program) in direct 8Ω setting, plus built-in 110, 55, 28, 14 Watt on 70V/100V multi-tap transformer i/c connection testing etc. as required.
4Supply, Replacement including rebate of old items, and Testing of Dual 15\\" subwoofer with 500W continuous power. The subwoofer should have a frequency response 40Hz - 250Hz, sensitivity of 94dB and max SPL of 122dB. The subwoofer should have 1 x 500 mm (15 in) driver with 75 mm (3 in) voice-coil, Nominal Impedance: 8 ohms i/c connection etc. complete as required.
5Supply and Replacement including rebate of old items, of suitable size custom built equipment rack suitable No’s of selves to accumulate 02 Nos. Mixer Amplifier and its accessories with lockable door’s arrangements etc. as required.
6Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR_2025_1.21.1) a) 20mm
7Supply and Replacement including rebate of old items, of 2 x 1.5 sqmm transparent FR PVC insulated, twin core copper conductor (Flexible) Industrial Speaker cable). etc. as required.
8Supply and Replacement including rebate of old items, of 2 x 1.5 sqmm Industrial Flexible ABC Conductor, PVC Insulated, Overall Shielded by Al-mylar along with ATC drain wire & Overall PVC Sheathed Cable etc. as required.
9Laying of one number PVC insulated and PVC sheathed/ XLP power cable of 1.1 K.V grade of following size in the existing RCC/HUME/METAL/DWC /HDPE pipe etc as required. (DSR 2025_10.5.1) a) Upto 35 sq. mm (DS:R2025_10.5.1)
10IEIWork Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (i/c rebate of replaced item). a) Group C (DSR-2025,1.10.3)
11Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm F copper conductor single core cable etc. as required. (i/c rebate of replaced items)a) Group C (DSR2025, 1.55.3)
12Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed meduim class PVC conduit alongwith 1 No. 4 sq. mm FRLSPVC insulated copper conductor single core cable for loop earthing (i/c rebate of replaced items)as required. (DSR-2025,1.12)
13Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (i/c rebate of replaced items)(DSR-2025,1.13)
14Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.'(i/c rebate of replaced items)a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR-2025,1.14.1)
15b) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (DSR-2025,1.14.11)
16Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (i/c rebate of replaced item).1 Pair (DSR-2025,1.18)
17Supplying and fixing following size. Modules. GI box along with modular base cover plate for modualr switches in recess etc. as reqd. (i/c rebate of replaced items)(a) 1 or 2 Module (75mm x 75mm) (DSR-2025,1.27)
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (i/c rebate of replaced items)a) Telephone socket outlet (DSR-2025,1.24.6)
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (i/c rebate of replaced items) (DSR2025,1.31)
20Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (i/c rebate of replaced items) (DSR-2025,1.32)
21Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (i/c rebate of replaced items) (DSR_2025)a) 4 way (4 + 12), Double door
22b) 6 way (4 + 18), Double door
23c) 8 way (4 + 24), Double door
24Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i/c rebate of replaced items)a) Single pole (DSR-2025,2.10)
25b) Double pole
26c) Triple pole and neutral
27Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. (i/c rebate of replaced items) (DSR-2025,2.11)
28Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, MCB TPN having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps
29Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as reuired. (DSR- 2025,1.21.2) (i/c rebate of replaced item). a) 25 mm
30Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (DSR_2025_5.18)
31Supply and replacement of Plastic ventilation Fan size 250 mm single phase, fixing the same on existing opening with suitable nut bolt fixture and plywood after cutting making hole in plywood, connection, testing etc. as reqd. (i/c rebate of replaced items)
32Supply and replacement of Heavy duty exhaust Fan single phase, fixing the same on existing opening with suitable nut bolt fixture and plywood after cutting making hole in plywood, connection, testing etc. as reqd. (i/c rebate of replaced items) a) 300 mm
33Supply of 4000K, 5700K, 6500K IP20, IK07 Inbuild Driver each 3mtr length contain 45W, Body Color - BK/WH, and installation as per the required design, drawing in the linear/ hexagonal/ circular as approved by Engineer In-Charge. The light shall be ceilinig suspended through GI wires/fastner with suitable GI frame as required.
34CCTVSupplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30 fps Sub streams minimum: 720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)— to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens
35Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 degree Celsius to +50 degree Celsius. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/ RADIUS database, Port-based Access Control and EAP, OTP, TLS,TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP- MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/ Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India, Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product Must be on Trusted Telecom Portal of Department of Telecommunication, Government of India, (DSR 2025_39.1.1)a) 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
36Supply and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required. (DSR 2025_39.26)
37Supply and Replacement including rebate of old items, of UTP 4 pair Solid Copper Cable 23 AWG GI wire armoured Cable with accessories etc. complete as required.
38Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (DSR 2025_10.7.1) a) Upto 35 sq. mm (clamped with 1mm thick saddle) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58081081
AUTHORITY Local Bodies
TENDER VALUE 35.99 Lakhs
LAST DATE 23-10-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Upgradation Of Play Fields Parks At Various Sports Complexes. Sub Head :Supply And Replacement Of Music/Sound System,Iei And Cctv System In Gym At Siri Fort Sports Complex.
Basic Detail
Tender No 46/EE/ELD-3/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 16 Oct 2026
Submission Date 23 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 35.99 Lakhs
Tender Fee Ref. Documents
EMD 71983
Exemption Not Available
Document List
0bcccc59-52b0-4ad9-acb0-3a123b1bee31.html
BOQ_978046.xls
NIT46.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

0bcccc59-52b0-4ad9-acb0-3a123b1bee31.html

xls

BOQ_978046.xls

pdf

NIT46.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender