Tender For Special Repairs To Bldg No P-07 Jco Md Accn At Basant Enclave Under Ge Missamari
Tender Value
31.92 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
11 days left
EMD
63845
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repairs To Bldg No P-07 Jco Md Accn At Basant Enclave Under Ge Missamari
BOQ
| Sl. No. | Item Description |
| 1 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) completed all specified and directed. |
| 2 | Taking down Chowkhats or frames exc 1.5 sqm and not 4.00 sq. m each but with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 3 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 125 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 4 | S&F Pressed steel frames for doors with one or more rebates,1.25mm thk cold rolled mild steel sheet, size of frame 105 x 60mm including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 5 | M&L plain cement concrete type B-1 (1:2:4) using 12.5 mm graded stone aggregate as in coping, hauncing, benching etc rounded or chamfered on edges complete all as specified and directed. |
| 6 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. Make : Century Ply, Green Ply, Archid Ply or equivalent as approved by GE. |
| 7 | S&F 25 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. Make : Century Ply, Green Ply, Archid Ply or equivalent as approved by GE. |
| 8 | S & F 35 mm thick factory made Second class hard wood kiln seasoned and chemically pressure treated Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc, complete all as specified and directed. |
| 9 | S&F for solid PVC door frame of size 50mmx95mm made out of 5mm plain colour PVC sheet rainforced with MS square tube in opening as per specification & as directed. |
| 10 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 11 | S&F powder coated anodised aluminium frame for doors, windows, ventileters with one or more rebates including joining cleat for fixing etc complete all as specified (minimum thickness of powder coating 50 micron). |
| 12 | S&F anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber neoprene packing anodised aluminium snap beading screws, necessary locking arrangement etc complete all as specifid power coating of any colour (thickness of power coating not less than 50 micron.) |
| 13 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165 complete all specified and directed. |
| 14 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane complete all specified and directed. |
| 15 | S & F 4 mm thick frosted glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed. |
| 16 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples complete all as specified and as directed. |
| 17 | M&L in repair 18/19 mm thick pre-laminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in alum frame work, complete all as specified and directed. |
| 18 | S & F 30mm long medium weight, cold rolled mild steel Butt hinges and fixed , complete all as specified and directed. |
| 19 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all specified and directed. |
| 20 | M&L plain cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate as in coping, hauncing, benching etc rounded or chamfered on edges complete all as specified and directed. |
| 21 | S&F mild steel flat iron of size 50x3mm as in hold fast complete all as specified and directed. |
| 22 | S & F 100 mm long medium weight, cold rolled mild steel Butt hinges and fixed , complete all as specified and directed. |
| 23 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised,complete all as specified and directed. |
| 24 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section,complete all as specified and directed. |
| 25 | S&F aluminium alloy 300mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy and fixed,complete all as specified and directed. |
| 26 | Supply fix in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified. |
| 27 | S&F 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 28 | S& F for Vitreous China (Pedestal pattern) Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. pipe) incl PVC seat cover complete in all respect all as specified. “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 29 | S&F vitreous China wash basin, white, flat back, size 550x400mm including brackets cutting for and pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) including weste pipe.(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 30 | S&F health faucet with 15mm dia, 1.25 meter long easy flexible tube in chrome finish & wall hook all as specified and as directed |
| 31 | S & F PVC connection 15 mm bore 450 mm long complete all specified and directed. |
| 32 | S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 33 | S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 34 | S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar of dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, complete all as specified and directed. |
| 35 | S&F in repair kitchen plate rack made of stainless steel sheet not less than 0.63 mm thick of over all size 1050 x 750 x 250 mm complete all as specified and as directed. |
| 36 | S&F 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete as specified and as directed. |
| 37 | S&F in repair 15mm bore Bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 38 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all specified and directed. |
| 39 | S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 40 | M&L 75 mm bore for PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all specified and directed. |
| 41 | Supply & fix in repairs 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all specified and directed. |
| 42 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls including Taking down rain water pipes inculding all fittings any size and pattern,complete all as specified and directed. |
| 43 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls including Taking down rain water pipes inculding all fittings any size and pattern, complete all as specified and directed. |
| 44 | S&F 110 mm bore PVC (SWR) bends of any radius,complete all as specified and directed. |
| 45 | S&F 75 mm bore PVC (SWR) bends of any radius,complete all as specified and directed. |
| 46 | S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all specified and directed. |
| 47 | S&F 110 mm bore PVC (SWR) Vent Cowl,complete all as specified and directed. |
| 48 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, including taking out old unserviceable 15mm bore GI pipe complete all as specified and as directed. |
| 49 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors including taking out old unserviceable 20mm bore GI pipe complete all as specified and as directed. |
| 50 | Supply and laying 32 mm dia CPVC pipes SDR 11 & plain/brass CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all specified and directed. |
| 51 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed,complete all as specified and as directed. |
| 52 | S&F Glazed ceramic coloured tiles in vertical surfaces 450x 300x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 10 mm thick in CM 1:4 including dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all specified and directed. |
| 53 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 54 | S&F non skid ceramic coloured tiles in 600 x 1200x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 15 mm thick in CM 1:6 including dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all specified and directed. |
| 55 | M&L Granite (of any type) tiles 18-20mm thick machine cut, floor laid bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 56 | M&L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 57 | M&L Machine cut kota stone slab on dado/skirting 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including including 10mm thick Screed bed or bedding layer of cement mortar 1:4, complete all as specified and directed. |
| 58 | Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level),complete all as specified and directed. |
| 59 | MM&L for 75 mm thick cement concrete as in plinth protection/ path etc type C-2 1:3:6 (using 40mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and directed. |
| 60 | M&L 100mm thick cement concrete type D-2 (1:2:4) using 20 mm graded stone aggregate as in Path/Hardstanding finished even and fair without using extra cement including demoliation of existing old unserviceable concrete of any description complete all as specified and directed. |
| 61 | M&L Pre polished chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over cement screed 20 mm thick in cement mortar 1:6 including dismantling/taking out existing unserviceable tiles and removing debries of the site complete all as specified and as directed. |
| 62 | M&L 15mm thick plaster of cement mortar (1:3) rendering on fair faces of brick work mixed with and including water proofing compound as per manufacturer's instructions, finishing the surface even and smooth without using extra cement complete all as specified and directed. (Note:- WPC shall be measured and paid separately). |
| 63 | Supply only NITTO water proofing compound complete all as specified and directed. |
| 64 | M & L for plain cement concrete Type E2 1:5:10 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all specified and directed. |
| 65 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws all as specified complete complete all as specified and directed. |
| 66 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 67 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins,arches, pillars, etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-Charge. |
| 68 | M&L for Brickwork with burnt old size bricks, straight or curved on plan to any radius built in cement mortar 1:6 complete all as specified and as directed. |
| 69 | M&L 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work mixed with and including water proofing compound as per manufacturer's instructions, finishing the surface even and smooth without using extra cement complete all as specified and directed. (Note:- WPC shall be measured and paid separately). |
| 70 | Material & Labour for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick acrylic wall care putty. |
| 71 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth, without using extra cement, complete all as specified and directed.. |
| 72 | M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered/putty surface to prepara-tory to distempering complete all as specified and directed over 1 mm thick acrylic wall care putty complete all specified and directed. |
| 73 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 74 | Supply only Integral water proofing compound complete all as specified and directed. |
| 75 | M&L preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (first quality) over a Red oxide or zinc chrome primer complete all as specified and directed. |
| 76 | Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer over applying two coat of synthetic enamel paint,complete all as specified and directed. |
| 77 | M & L for Complete removal of old surface for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over old surface ,complete all as specified and directed. |
| 78 | M&L for complete removal of old surfaces of walls and applying two coats of acrylic distemper including one coat of primer on plastered/putty surface to prepare for distempering complete all as specified and directed over 1 mm thick acrylic based wall care putty. |
| 79 | M&L preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed. |
| 80 | M&L preparation of old decorated plastered surfaces of walls and applying one coat of white wash, complete all as specified and as directed. |
| 81 | S&F color coated (SDP) pre painted galvalume aluminium zinc coating AZ150 Gl based corrugated steel sheet 0.50 mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw, butyl tape, end foam filler including dismantling plain or corrugated steel sheeting any gauge, thickness in roof covering as specified. |
| 82 | S&F color coated (SDP) pre painted galvalume aluminium zinc coating AZ150 Gl based plain steel sheet 0.50 mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw, butyl tape, end foam filler including dismantling plain or corrugated steel sheeting any gauge ,thickness in roof covering as specified. |
| 83 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165) complete all as specified |
| 84 | Removing complete existing treatment incl pcc pedding of roof surfaces by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed. |
| 85 | M&L for brushing neat cement slurry with 03 Kg of cement per Sqm, complete all as specified and directed. |
| 86 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound, complete all as specified and directed. |
| 87 | M&L 25 mm thick cement concrete PCC Type B0 1:2:4 using 12.5 mm graded aggregate, complete all as specified and directed. |
| 88 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification complete all as specified and as directed:-(i) Applying one coat of bituminous primer @0.40 Ltr/Sqm.(ii) Laying of 3mm thick APP based polymeric membrane of approved manufacturer with weight not less than 3.50 Kg/Sqm, reinforced with non-woven polyster fabric weight not less than 160 gm/Sqm. Polymeric membrane shall be taken to a height of 30 cm(minimum) and then inserted inside the groove of parapet wall and wall shall be finished by a membrane plastering.Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. |
| 89 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.Note:- Concealed conduit in RCC slab/beam shall not be not be taken out |
| 90 | Taking down the existing unserviceable AC plug and socket including MCB/main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 91 | Taking down carefully unsv aluminium submain wiring of any type /location including conduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge. |
| 92 | Taking out unserviceable UG Cable any cross sectional area and connection of any description of any description laying in trenches of fixing with wall or poles complete all as specified and directed. Please Enable Macros to View BoQ information |
| 93 | Taking out unserviceable UG Cable any cross sectional area and connection of any description of any description laying in trenches of fixing with wall or poles complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender