Tender For Addition/Alteration To Bldg No P-590, P-591, P-592 & P-593 At Sqn At 4 Wg Under Ge Af Tech Area Agra
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | M&L Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed. |
| 3 | Dismantling wall and ceiling boards ( fibre, pulp, insulation etc or insulation boards/ slabs/ blankets any thickness including cover filletts complete all as specified and directed. |
| 4 | Providing & fixing false ceiling at (a) all heights with GRG (Glass Fibre With Semi With fully Reinforced Gypsum) false ceiling tiles of perforated perforated 12mm Size 595 x 595 mm of approved texture, 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistanceedged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 6 | M & L for glazed ceramic coloured tiles joint free of size 350x250 x 7 /450x350x7mm (Ist quality/Premium quality), in vertical surfaces such as riser of steps, skirting, dado and pillar, over and including rendering 10mm thick plastering as bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 7 | M&L for 10 mm thick Vitrified ceramic tiles,Dark shade shade/ double charged (square/recangular) area of each tile n exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed. |
| 8 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with incl 15mm thick screed bed in CM 1:4 laid jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all complete as specified and directed. |
| 9 | Demolition of cement concrete (unreinforced) in ground floor and paving exc 15 cm thickness (below or above ground) complete all as specified and directed. |
| 10 | M&L for 100mm thick PCC(1:3:6) type C2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed. |
| 11 | M&L for PCC 1:2:4 type B-1 ( 20mm graded stone agg) 50 mm thick as in floor,coping etc complete all as specified and directed. |
| 12 | M&L for 40 mm thick sand cushioning laid dry to the profile under interlocking block complete all as specified and as directed. |
| 13 | M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60mm thickness,with minimum compressive strength of 35N/sqmm (M-35 grade) without correction factor for chamfering,made in rubber moulds with 0.50mm thick scratch proof lacquer coating on top surface,with grey cement and pigment complete all as specified and directed. |
| 14 | M&L 20-25mm thick plastic coated coloured chequered tiles,area of each tile exc 0.05sqm but n.exc 0.09sqm with and incl 15mm thick screed bed in CM (1:4) of approved colour and pointing with grey cement and pigment complete all as specified and directed. |
| 15 | M&L for PVC wall profile for wall panelling colour/shade as approved size250mm wide,08mm over all thick with 1mm wall thickness fixed with screw fixed to walls with necessary frame , complete all as specified and as directed by EIC. Note:-incl Taking down of existing switch board/tube light etc and fixing the same |
| 16 | M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching wall panelling complete,all as specified and as directed by EIC. |
| 17 | M&L for solid PVC wall lining consisting of 5.00mm thick single side prelaminated PVC sheet inclusive of insolvent cement and fixing at site on PVC frame complete all as specified and as directed . Note:-incl Taking down of existing switch board/tube light etc and fixing the same. |
| 18 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and as directed |
| 19 | M&L 20mm thick Granite telephonic black (of any type) tiles machine cut, in skirting/ dado laid over cement screed 15mm thick and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 20 | Taking down cement plaster of any description on brick wall, ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 21 | M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair complete all as specified and directed at any location in any area incl repairing in patches at parapet, facing, fins, etc if any required at site for entire completion of work all as specified and directed |
| 22 | M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ 3% by weight of cement finished fair complete all as specified and directed at any location in any area incl repairing in patches at parapet, facing, fins, etc if any required at site for entire completion of work all as specified. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’. |
| 23 | M & L for rendering 10mm thick in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in camoflage pattern, as per manufactures instructions etc complete all as specified and as directed. Note :- Primer to be carried out through air less spray machine (Mechanical means) incl cleaning of existing windows/doors/floor etc. |
| 25 | M&L for providing & applying average 1mm thick of Birla/ JK wall care putty over prepared surface to achieve the surface even and smooth for painting, complete all as specified and as directed. |
| 26 | M&L for preparation of new plastered surface of ceiling applying three coat of white wash by using mechanical device complete all as specified and as directed. |
| 27 | M&L for preparation of new surfaces of walls and applying two coat of oil bound distemper white or tinted over a coat of primer all as directed. |
| 28 | M&L Providing and injecting chemiical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along thewall and rodding etc. complete |
| 29 | M&L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed. |
| 30 | M&L Of voids in masonry using chemical emulsion one litre per hole, at 300mmintervals including drilling holes at 45degree and replugging them with cement mortar 1:2 (1 cement : 2 coarsesand) to match the existing floors all as specified and directed. |
| 31 | M&L for preparation of old surfaces of walls and applying one coat of oil bound distemper white or tinted complete all as specified and directed. |
| 32 | M&L for preparation of old surfaces and applying one coats of exterior emulsion paint in normal pattern as per manufacturers instructions etc complete all as specified and directed by Engr-in-charge. |
| 33 | M & L for prepararing old decorated steel surfaces of any description not exc 10 cm width or girth, not otherwise described and applying one coat of synthetic Enamel paint over aluminium red oxide primer ,in any position including necessary scaffolding and cardles complete all as specified and directed. |
| 34 | S&F in repairs automatic hydraulic door closer designation No.03 universal type,suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80kg , heavy duty with pivot, aluminium body(extruded section body), ISI marked, complete all as specified & directed. |
| 35 | M&L 12mm thick veneered partcle board exterior grade faced with decorative veneer on both faces including fixing with rubber gasket and all around aluminium frame for aluminium partition complete all as specified and directed. |
| 36 | S&F Aluminium Powder Coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators/Partition with extruded built up standard tubular sections/appropriate Z sections and other sections of appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i.e. at top,bottom and sides with required EPDM,rubber/neoprene gasket etc.Aluminium sections shall be smooth ,rust free,straight,mitred and jointed mechanically wherever required including cleat angle ,al snap beading for glazing/panelling,C.P. brass/stainless steel screws etc, complete all as specified. |
| 37 | S&F in repair venetian blinds in double layers roller type of approved colour including all accessories, fitting/fixtures required for fixing the same in windows complete all as specified and directed. |
| 38 | M&L gunniting to RCC works in column ,beams, slabs, landing, balconies etc by removing loose concrete including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick to rusted steel reinforcement after removing/ cleaning all rust by sand/grit blasting and supply and fixing welded steel wire mesh 75mm x 75mm with 3mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sika. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2.5 Kg/sqcm and applying 25mm thick layers of gunniting in cement mortar (1:2) using ordinary port land cement of 43 grade over wherever required complete all as specified. Note:- (i) After placing the additionnal reinforcement all concrete surface shall be throughly scrubbing with brushed washed with water and allow dry and plaster complete all as specified. (ii) Work to be carried out as in patches as directed by Engr-in-charge. (iii) Rate for scaffolding ,15mm thick plaster in CM 1:4 and TMT bars (where applicable) deemed to be included in quoated rate. (iv) preparation of surface and applying two coat of exterior emulsion paint with one coat of primer deemed to be included in this item. |
| 39 | M&L for preparation of roof surface and application of Dr fixit roofseal first coat of primeseal with 50% dilution, adequate time for drying. 1st coat of Dr fixit roofseal ultra undiluted. A glass fiber mesh of 2.5mm x 2.5mm needs to be sandwiched between the first coat and second coats. Then 2nd coat of Dr fixit roofseal ultra is applied to the first coat @ 1.4 ltrs/Sq mtr. Note:- work will be completed at various location in patch repair basis, glass fiber mesh will be paid separately. |
| 40 | M&L for glass fiber mesh of 2.5mm x 2.5mm, thickness of the material should not be less than 1mm or as specified by manufacturer. |
| 41 | Taking out / dismantling of mud or existing roof treatment of, any thickness, including plastering and leaping and tiling/ peding of any description including disposal of removed/demolished soil/material exc 1.5 km but n.exc 5 km, depositing out side the MD land or where directed ny Engg-in-charge, complete all as specified and directedspecified and directed. |
| 42 | M & L for the followings:- (A) Providing PCC 1:2:4 (12.5mm graded)50mm thick with finished slope of 1:30 to RCC roof slab or as indicated in Drgs, testing of RCC slab for any leakage/seepage and making good before carrying out the water proofing treatment.B. Providing average 15mm thick plaster in CM(Cement sand mortar) 1:3 mixed with water proofing compound when concrete is still green.C. After the concrete is fully dried. It shall be cleaned free from dust and shall be painted with a coat of bituminous primer @ 0.40 liters/Sqm.D. After primer, the entire roof surface shall be applied with hot blown bitumen grade 85/25 conforming to IS-702 @ 1.2 Kg/SqmE. Over hot bitumen, polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film with standard weight not less than 3 Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as of manufacture’s technical representation.F. Pre casted machine pressed cement conc tiles 250x250x20-22mm/ 300x300x20-22mm confirming to IS : 1237:1980 laid over 15 mm thick cement mortar screed in 1:3. Joints shall be flushed pointed in CM 1:3. |
| 43 | Supply only liquid water proofing compound complete all as specified and directed. |
| 44 | Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and module complete with programming and battery backup support complete all as specified and directed by engr-in-charge. |
| 45 | S&F addressable type multisensor detector with heat and smoke combination Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed by engr-in-charge. |
| 46 | S&F Remote response indicators complete all as specified. |
| 47 | M&L for taking down of multisensor detector including wiring and all associated items and refixing the same of multisensor detector after b/r work of fall cealing with heat and smoke combination complying with and type certified to EN-45 Addressable type smoke detector photoelectric/optical with base with self built intelligence as per IS :11360 complete all as specified and directed by engr-in-charge |
| 48 | S&F Fire Alarm hooters / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5db, 1000m range. For warning of fire connected with central control panel installed in each zone inside the rooms complete all as specified and directed |
| 49 | S&F Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of external dia 20mm complete all as specified and directed by engr-in-charge. |
| 50 | S&F rigid non metalic PVC Junction boxes (1 to 4 way) FOR 20MM external dia pipe complete all as specified and directed by engr-in-charge. |
| 51 | Supply and drawing of PVC insulated FRLS single core multi stranded copper conductor cable (ISI Marked) of 1.5 Sqmm size drawn in to conduit complete all as specified and directed by engr-in-charge. |
| 52 | M&L for double compression stainless steel gland for fixing armoured cable in panel of size up to 6 sqmm 2 core complete all as specified and directed by engr-in-charge. |
| 53 | Taking down carefully aluminium/copper point wiring (light/fan/socket or power) complete including fitting fixtures such as switches, socket, ceiling rose, brackets, holders, bulk head/tube light fitting etc. and removing materials from site and making good disturbed surface of walls/ floors etc. complete all as specified and directed |
| 54 | Supply and Fixing of three phase industrial plug and socket with MCB TPN 63 Amps capacity with 4 no of aluminium busbar of capacity 200A with sheet steel enclosure mounted on wall or floor with all fixing arrangements with provision of cable connection for incoming and outgoing complete and all as specified and directed |
| 55 | Supply, laying, commessioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts grade of size 10 Sqmm 4 core with aluminium conductor to IS 1554, ISI laid in tranchies, fixing on wall, under road crossing, etc complete all as specified and directed. |
| 56 | Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr in depth for laying under ground cable and getting out in soft / loose soil complete all as specified. |
| 57 | Returning , filling in , including spreading , leveling, watering and well ramming in layers n.exc. 25cm thick in soft / loose soil complete all as specified and directed. |
| 58 | Removing excavated materials to a distance not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 59 | Supply and fix double wall corrogated as per IS 16025 PART-24 pipe of outer dia 40mm and inner dia 30 mm ( including all connected fitting and accessories) all as specified and directed. |
| 60 | Taking down carefully and refixing the same split ac of 1.5TR/2TR capacity on the location as decided by the engineer in charge including disconnecting all electric connection and copper pipe and connected items etc and gas charging with required quantity of refrigerant gas R-22/M-22 or suitable gas and all fixing arrangement including outoor stand, PVC drainage pipe of 3 mtr length and copper pipe as required all as specified and directed by engineer in charge. |
| 61 | Supply and fixing sheet metal enclosure single pole and neutral with a two pin & earth plug and socket complete including one single pole MCB 20 Amps of 240v complete all as specified and directed by engr in charge |
| 62 | Taking down carefully and refixing the same voltage stablizer for automatic operation, single phase naturally air cooled indoor type for voltage regulation of split AC and UPS complete all as specified and directed by engineer in charge. |
| 63 | M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4 sqmm drawn in and including concealed PVC rigid conduit not less than 20mm dia with its accessories, concealed, including one run of single core FR PVC insulated, unsheathed, mutistranded copper conductor cable of size 4 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed.Note:- Two runs of 4sqmm cable & one run of 4 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 64 | M&L for point wiring with One light/fan/exhaust fan point controlled by one way 5 Amp switch complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including concealed PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed. |
| 65 | All as per srl item no. 64 above but for 3/5 pin socket outlet for 5 Amps on same board. |
| 66 | All as per srl item no. 64 above but for 3/5 pin socket outlet for 5 Amps on independent board with 1.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. |
| 67 | All as per srl item no. 64 above but for 3/5 pin socket outlet for 15 Amps on independent board with2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed. |
| 68 | Supply & fix socket outlet 2 in 1, 3 pin 5/6 Amps, flush universal type complete all as specified & directed. |
| 69 | Supply & fix socket outlet 2 in 1, 3/5 pin 15 Amps, flush universal type complete all as specified & directed. |
| 70 | Supply & fix switch piano, flush type single pole, one way 5/6 Amps, 240 volts complete all as specified & directed. |
| 71 | Supply & fix switch piano, flush type single pole, one way 15/ 16 Amps, 240 volts complete all as specified & directed. |
| 72 | M&L for taking down carefully existing ceiling fan/exhaust fan/wall fan from site before B/R repair work, keeping in safe custody in store for greasing/oiling of ball bearings/bushes and making it for smooth functioning and noise free operation and painting with HI- Gloss synthetic enamel paint of approved shade, by spray painting after filling cavaties and re-fixing after providing new fan clamp,nuts/bolts, washers, down rod of required length after fall cealing and provision of 3 core 1.5sqmm flexible copper conductor cable from ceiling rose to fan connector complete with writing of MES NO. XXXX ON the body of fan surface complete all as specified and directed. |
| 73 | M&L for taking down and refixing the same after B/R work ceiling recessed mounting 2x2 Led panel square type 35 WATT, complete including connecting wire from celing rose to light fittings complete all as specified and directed by engr-in-charge. |
| 74 | S&F in ceiling recessed mounting 2x2 LED panel square type, complete of size 35 watt including connecting wire from celing rose to light fittings compelet all as specified and directed. |
| 75 | S&F surface/wall mounting LED batten, extruded aluminium housing provided for efficient heat dissipatin with poly carbonate diffuser & intergrated electronoc driver including 22 watt LED complete fitting as specified and directed. |
| 76 | Supply & fix ceiling rose, surface bakelite, 32.5x25mm surface type, three terminals, AC 240 volts complete all as specified & directed. |
| 77 | Supply and fix in renewal of building Security light of LED light 35 W IP 66, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device including GI bracket made by 40mm GI pipe light grade bent to shape of length up to 1.5 mtrs and with clamps ,nut bolts grouting on wall and complete all as specified and directed. |
| 78 | Material and labour for brick work with sub-class ''B'' bricks (using old size bricks) ,straight or curved on plan exc 6m mean radius, built in cement mortat (1:4) all as specified and directed by engr in charge |
| 79 | Material and labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces cement plaster (1:4) all as specified and directed by engr in charge. |
| 80 | Material and labour for cement concrete in foundations, filling and mass concrete of type D2 (1:4:8) 40MM graded stone aggregate all as specified and directed by engr in charge. |
| 81 | Material and labour for cement concrete in foundations, filling and mass concrete of type B2 (1:2:4) 40MM graded stone aggregate all as specified and directed by engr in charge. |
| 82 | S&F in repair factory made sheet metal enclosure MCB DB 415V volts, 12 ways with 200A rated bus bar, SPN, double door type IP43 suitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified & directed. |
| 83 | S&F in repair factory made sheet metal enclosure MCB DB 415V volts, 8 ways with 200A rated bus bar, SPN, double door type IP43 suitable for housing MCB/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified & directed. |
| 84 | Supply & fix in MCB, SP, AC, 240 volts of 06 to 32 Amps capacity \\"C\\" series and making connections complete all as specified & directed. |
| 85 | Supply and fixed in MCB TPN 63 Amp 240V, 'C' series 10 KA, complete all as specified and directed. |
| 86 | Supply and fixed in MCB SPN 32 Amp 240V, 'C' series 10 KA, complete all as specified and directed. |
| 87 | S&F in provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm drawn in and including PVC rigid conduit not less than 25mm dia with its accessories, concealed, including one run of single core FR PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed.Note:- two runs of 10 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 88 | M&L for earthing in renewal of complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron wire of size 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of copper strip incl laying of charcoal dust and common salt PCC (1:2:3) type C-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test incl testing complete all as specified an directed. |
| 89 | Deduct Schedule of Credit of ₹ 20040.00 as brought out from serial page No 34 of tender Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in ₹ |
| 90 | Old unserviceable brick bats |
| 91 | Old unserviceable False ceiling/Wall penalling etc |
| 92 | Old unserviceable Hydraulic door closer |
| 93 | Old unserviceable floor hearth tiling |
| 94 | Old unserviceable point wiring copper/aluminium complete with conduit/woodwn or PVC batten etc |
| 95 | Old unserviceable material such as switches,sockets, Ceiling rose, Regulator etc of any type. |
| 96 | Old unserviceable light fitting of any type and any size |
| 97 | Old unserviceable main switches/ MCB DBs/ MCBs/ MCCBs/junction/ sunken boxes of any capacity/ description |
| 98 | OLD unserviceable earthing |
| 99 | Old unserviceable sheet metal enclosure |
| 100 | Old unserviceable Multi sensor detector with heat and smoke combintation |
| 101 | Old unserviceable FIRE alarm control panel |
| 102 | Old unserviceable Fire alarm hooter |
| 103 | Old unserviceable PVC INSULATED FRLS 1.5 sqmm cable armoured Total amount of credit schedule 20040.0 Signature of contractor AGE (Contracts) For ACCEPTING OFFICER |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender