Tender For providing Fixing Pvc Pipe, Construction Of Masonry Sluice Valves Chamber, Sewerage System, Rising Main, Construction Of Ugsr, Tubewell, Electrical Panel Etc At Govt I.T.I Buildings (G+5) At Nangal Distt Roopnagar (Public Health Services).
Tender Overview
Project Description
Tender for providing Fixing Pvc Pipe, Construction Of Masonry Sluice Valves Chamber, Sewerage System, Rising Main, Construction Of Ugsr, Tubewell, Electrical Panel Etc At Govt I.T.I Buildings (G+5) At Nangal Distt Roopnagar (Public Health Services). (Under Head Eds-80 School Of Eminence
BOQ
| Sl. No. | Item Description |
| 1 | Sub head-1 Estate Water Supply distribution system |
| 2 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removalof surplus soil from the site upto 15 meter distance complete in all respects. |
| 3 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per iSi-4985 (iSi marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 4 | 90mm o/d pipe of 6 Kgf. / sqcm |
| 5 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). |
| 6 | 80mm i/d sluice valve flanged |
| 7 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 8 | Size 0.9 m. x 0.9 m. |
| 9 | Sub head-2 Estate Sewerage System |
| 10 | Excavation by mechanical means (JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering, including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 11 | Depth not exceeding 3 m. BGL |
| 12 | For Ordinary Soil having gravel 40% |
| 13 | 160 mm pipe |
| 14 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 15 | Single socket type B |
| 16 | 160mm o/d single socket SWR UPVC pipe lines laid complete IC TO MH |
| 17 | Sand filling under floor and in wells of bridge foundation including handling withing 100 metres |
| 18 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 19 | Inside size 90x150 cm and 120 cm deep |
| 20 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 21 | 200mm o/d pipe |
| 22 | Sub head- 3 Strome sewer System with Recharge well |
| 23 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 24 | 200mm o/d PVC pipe of 4 Kgf. / sqcm |
| 25 | Supplying, fixing and jointing PVC / H.D.P.E pipe's specials complete as desired by Engineer-in-Charge. For pipe lines laid inside habitation |
| 26 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 27 | Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. |
| 28 | For depths not exceeding 3.0 metre B.G.L.For all classes of soil except rocky |
| 29 | Storm water Line 200 mm i/d pipe |
| 30 | Construction of Haudi internal size 0.90 mtr. x 0.90 mtr. & 0.90 mtr. depth in Brick masnory 1:5 bed 40mm thick cement 1:2:4, 150mm thick base lean concrete 1:8:16, RCC slab cover 75 mm thick inside plaster, cement rendering & RCC man hole cover 450x450mm clear inside opening rectangular RCC Manhole cover with frame light duty. |
| 31 | Providing, Laying, Houdies prior approval of Engineer-in-Charge) Haudies (Size 0.45 Mtr x 0.45 Mtr.) |
| 32 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 33 | 110mm o/d PVC pipe of 4 Kgf. / sqcm |
| 34 | 160mm o/d PVC pipe of 4 Kgf. / sqcm |
| 35 | Supplying, fixing and jointing PVC / H.D.P.E pipe's specials complete as desired by Engineer-in-Charge. For pipe lines laid inside habitation |
| 36 | Sub head- 4 Recharge well |
| 37 | Construction of Recharge well 4.5mtr dia up to 4 mtr depth 1 No. ,installation of 200mm i/d tubewell up to 50 mtr depth complete in all respects. |
| 38 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. |
| 39 | From bottom of wellBoring with 300mm id Housing Pipe |
| 40 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge. 200mm nominal size dia |
| 41 | Bore well |
| 42 | Collecting chamber to well |
| 43 | 200 mm nominal size dia. |
| 44 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200mm nominal size dia |
| 45 | Supplying & Fixing of M.S pipe bail plug suitable for 200 mm dia UPVC casing pipe having thickness of socket as 12 mm, length 100 mm & base plate of 8 mm thick complete in all respect. |
| 46 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 47 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 200mm internal dia |
| 48 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 49 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.200mm internal dia |
| 50 | Foot Rest for Manhole.Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 51 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 52 | Cement concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type |
| 53 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 54 | Extra for specially moulded brick work in circular work such as well shafts circular sumps, pump chambers etc. in which specially moulded or cut bricks have to be used but for which no centring or supports are required upto 4.5 metre internal diametre. |
| 55 | 12.5 mm thick cement plaster 1:2 |
| 56 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry). |
| 57 | 1st layer |
| 58 | Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry). |
| 59 | 2nd Layer |
| 60 | Third Layer :----- Bajri screened,cleaned and washed and graded from 6mm to 20mm (from Pathankot or approved equivalent quarry). |
| 61 | 3rd Layer |
| 62 | Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry). |
| 63 | 4th Layer |
| 64 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 65 | Deduct Man Hole |
| 66 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 67 | Outer Face Of Slab |
| 68 | Man Hole Inner face |
| 69 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 70 | Providing and fixing RCC manhole covers 560mm i/d heavy duty |
| 71 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 72 | Angle |
| 73 | 3.5 kg/mtr |
| 74 | Flats 30x5 strips 1 1/2\\" C/C |
| 75 | 1.2kg./mtr |
| 76 | Central angle for openable shutter |
| 77 | 3.5 kg/mtr |
| 78 | Total A+B+C:- |
| 79 | Sub Head -5 Tubewell |
| 80 | Drilling of 400mm dia bore with Direct Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect.a)Drilling of 400mm dia bore with Direct Rotatry Rig Upto 200 m depth BGL. |
| 81 | Supplying & lowering MS Pipe as per IS 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strenght to lower the pipe into tubewell bore. |
| 82 | 200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness |
| 83 | Supplying, fixing lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI Marked,duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. |
| 84 | 200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness |
| 85 | Supplying and fixing of bail plug of M.S. Pipe complete with inverted U-hook attached to the bottom plug complete in all respects. |
| 86 | 200mm internal diameter (Weight 33.6 kg per meter) 6.4 mm thickness. |
| 87 | Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 88 | Supplying and fixing of well cap having threads to fix on housing pipe complete in all respects. |
| 89 | 200mm internal diameter |
| 90 | Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects. |
| 91 | Supplying, fixing and lowering of stainless steel socket as per IS 8110: 2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects. |
| 92 | 200mm internal diameter |
| 93 | Supplying at site wooden box of suitable size with Lid & lockign arrangement for preserving strata sample collected from the bore. |
| 94 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 95 | Development and stabilizing of the tubewell with Air compressor or required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 96 | Capacity of Air Compressor 300 cfm at 250 PSI |
| 97 | Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 98 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 99 | Testing of water sample for Heavy metal fromapproved laboratory (Toxic material such asArsenic, lead, mercury, pesticide uranium etc.) |
| 100 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect |
| 101 | Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect. |
| 102 | Providing & Fixing Clay seal in graval pack minimum 3 Mtr.(As per BIS Code 2800:2019) |
| 103 | Providing & Fixing Sanitery Seal (As per BIS Code 2800:2019) |
| 104 | Sterilization of Well (As per BIS Code 2800:2019) |
| 105 | Providing, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make, capable of deleviring 131lpm against a head of 62mt . Complete in all respects. (5HP ) |
| 106 | Supplying lowering of 65 mm dia GI pipe as per IS 1239 (B - class) premim make such (as Jindal Hisar) including cost of specials such as tees, bends, sockets elbow etc, cutting, treading and testing in trenches in the ground. Complete in all respects |
| 107 | Providing and fixing of submerssible of mm 2.5 mm² core cable, complete in all respect |
| 108 | Providing installing, testing and commissioning of 1 no. control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays, isolator switches wiring and connnections. Complete in all respect. |
| 109 | C.I FITTING INSIDE PUMP CHAMBER |
| 110 | Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump room as per standard design complete in all respects (Analysis attached) |
| 111 | Construction of V- Notch Houdi (Size 1.80 x 0.90 m) including cost of v – notch as per standard design & drawings of Public health Department. |
| 112 | Providing, installing, testing and commissioning of 1 no. Electrically driven centrifugal pumping set of reputed make, capable of deleviring 450 lpm against a head of 60 mt . Complete in all respects. (7.5 BHP) (One working +one standby) |
| 113 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 65mm i/d |
| 114 | Providing and fixing of submerssible of mm 2.5 mm² core cable, complete in all respect |
| 115 | Providing installing, testing and commissioning of 1 no. control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays, isolator switches wiring and connnections. Complete in all respect. |
| 116 | Providing and installing 80mm dia delivery main (From UGSR to Centrifugal pumps including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump room as per standard design complete in all respects |
| 117 | PUMPING MAIN (RISING MAIN) |
| 118 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation. (Manually) (Analysis attached) |
| 119 | 75mm o/d pipe of 10 Kgf. / sqcm |
| 120 | Sub head-6 Installation of Water coolers and RO System |
| 121 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 122 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 123 | Providing & fixing in position RO of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 124 | Sub Head-7 Installation of AC |
| 125 | Providing and installing Hitachi/ O-General/ Carrier/ Mitsubishi/ Toshiba make 5-Star Inverter model (with installation kit i.e. 3 Mtr. Copper Pipe, copper cable from OD to ID etc) or any other equivalent make Split type Air Conditioner of 1.5 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. Cooling capacity minium 600 W |
| 126 | Providing and installing Hitachi/ O-General/ Carrier/ Mitsubishi/ Toshiba make 5-Star Inverter model (with installation kit i.e. 3 Mtr. Copper Pipe, copper cable from OD to ID etc) or any other equivalent make Split type Air Conditioner of 2.0 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. |
| 127 | AUTOMATIC VOLTAGE STABLIZER: |
| 128 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided |
| 129 | Automatic Voltage Stablizer 4 KVA |
| 130 | Automatic Voltage Stablizer 5 KVA |
| 131 | Providing and fixing angle iron stands for placing outdoor units. |
| 132 | Drain Water piping Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. (25 mm nom. Dia)- for Split Ac 25mm = 3 mtr. each(94 No. x 3 mtr. = 282 Mtr.) |
| 133 | uPVC Pipe 10 Kgf/cm2 |
| 134 | 25mm i/d |
| 135 | Providing & fixing Copper Refrigerant pipe (in addition to the default 3 mtr. Length already provided with each AC) = 4 meter each 94 x 4 = 376 meter |
| 136 | Sub head-8 Construction of UGSR 70,000 ltr capacity for Fire Fighting system and Drinking water |
| 137 | Earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling |
| 138 | For ordinary gravel soil involving pick work |
| 139 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 140 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 141 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 142 | (carrage material drive rate) |
| 143 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth |
| 144 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 145 | Door area for motor room |
| 146 | (carrage material drive rate) |
| 147 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/Sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 148 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glossy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per Sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 149 | 12.5 mm thick cement plaster 1:5 Walls |
| 150 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface. Complete as per specifications |
| 151 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 152 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 153 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code: IS 2202-1 (1999) |
| 154 | 35mm thick |
| 155 | Wire gauge Hollock wood door shutter without springs housed in chowkhat 35mm thick |
| 156 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250mm x 16mm |
| 157 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 4mm thick or 10.78 Kg/ sqm |
| 158 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 159 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 160 | Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).560mm i/d RCC man hole cover with frame as per ISI |
| 161 | Supplying, fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. |
| 162 | Sub head-9 Internal and External Fire Fighting Arrangment including Hydrant,Fire Extinguishers & UGSR Main Pumps as per NBC Norms |
| 163 | MAIN PUMPSET FOR HYDRANT SYSTEM |
| 164 | Supplying, installation, testing & commissioning of approved make horizontally mounted coupled motor (Eff-1) 60hp, 2900 RPM, 3 Ph 415 V with mechanical seal pump delivery of 2280 litres per minute against total head of 70 meter so as to ensure a minimum pressure of 3.5 Kg/Cm2 at the highest. The impeller shall be closed type and accurately balanced dynamically. The pump shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel, automatic air release valve, pressure gauges (combination suction gauge, 3½” dial type with ¼” cock and lever handle - 1 no, discharge gauge, 3½” dial type with ¼” cock and lever handle - 1 no.) i/c coupling, coupling guard, base channel foundation &matching flanges etc. as required as per specifications. The fire pump set as per NFPA –20 specifications. |
| 165 | Common bed plate of fabricated mild steel channel or cast iron type. |
| 166 | Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. |
| 167 | The pump shall be of the following specifications: |
| 168 | Discharge - 2280 lpm |
| 169 | Head - 70 m |
| 170 | No. of stage preferred - Single / Double |
| 171 | Speed RPM - 2900 |
| 172 | Material of construction |
| 173 | a) Impeller - Bronze |
| 174 | b) Casing - C.I. |
| 175 | c) Shaft & Shaft Sleeve - SS-410 |
| 176 | d) Bearing - Grease Lubicated |
| 177 | Type of pump - End suction |
| 178 | JOCKEY PUMPSET |
| 179 | Supplying, installation, testing & commissioning of approved make jockey pump horizontally mounted coupled motor (Eff-2) 5.5hp, 2900 RPM, 3 Ph 415 V with mechanical seal pump, delivery of 180 litres per minute against total head of 70 / 88 meter so as to ensure a minimum pressure of 3.5 Kg/Cm2 at the highest. The impeller shall be closed type and accurately balanced dynamically. The pump shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. i/c coupling, coupling guard, base channel foundation & matching flanges etc. as required as per specifications |
| 180 | Common bed plate of fabricated mild steel channel or cast iron type. |
| 181 | Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. |
| 182 | The pump shall be of the following specifications: |
| 183 | Discharge - 180 lpm |
| 184 | Head - 70 m |
| 185 | No. of stage preferred - Multistage |
| 186 | Speed RPM - 2900 |
| 187 | Mover - Electric Motor Driven |
| 188 | Material of construction |
| 189 | a) Impeller - Bronze |
| 190 | b) Casing - C.I. |
| 191 | c) Shaft & Shaft Sleeve - SS-410 |
| 192 | d) Bearing - Grease Lubicated |
| 193 | Type of pump - End suction |
| 194 | DIESEL ENGINE |
| 195 | Supplying & installation of approved make diesel engine driven firefighting pump water cooled 65 BHP 2150 RPM engine, fuel tank 200 Ltr (empty), accessories, matching flanges, base frame, ARV , fuel gauge, exide12 Volt battery & charger, lugs & cable between battery & charger. The pump capacity of 2280 litres per minute at total head 70 meters, automatic air release valve, pressure gauges (combination suction gauge, 3½” dial type with ¼” cock and lever handle - 1 no, discharge gauge, 3½” dial type with ¼” cock and lever handle - 1 no.) as required. All above equipment's are mounted on common base plate. The fire pump set as per NFPA –20 specifications. |
| 196 | Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump. |
| 197 | Flexible coupling and coupling guard with the Pump, |
| 198 | Common bed plate of fabricated mild steel channel or cast iron type. |
| 199 | Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. |
| 200 | Engine panel |
| 201 | Sealed maintenance free batteries of 24 V, 88 AH |
| 202 | Exhaust pipe of required length with asbestos lagging, muffler |
| 203 | Day oil tank of 400 lts with first charge and manual oil pump set. |
| 204 | The pump shall be of the following specifications: |
| 205 | Discharge - 2280 lpm |
| 206 | Head - 70 Mtr |
| 207 | No. of stage preferred - Single / Double |
| 208 | Speed RPM - 2150 RPM |
| 209 | Mover - Diesel engine driven |
| 210 | Material of construction |
| 211 | a) Impeller - Bronze |
| 212 | b) Casing - C.I. |
| 213 | c) Shaft & Shaft Sleeve - SS-410 |
| 214 | d) Bearing - Grease Lubicated |
| 215 | e) Type of pump - End Suction |
| 216 | AIR CUSHION TANK |
| 217 | Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 218 | ELECTRICAL PANEL |
| 219 | DSupplying, installation, testing & commissioning of cubical type floor mounted electrical control panel of 2.0 mm thick CRCA sheet suitable for 380-415 Volt, 50 Hz, 3 Ph supply, NEMA type 2 (IP 31) drip proof metal free standing enclosure for firefighting pumps with suitable star-delta starter including indicating lamps, ammeter, voltmeter, selector switches for each, incoming and outgoing feeder, auxiliary switches, dry suction cut off, single phase preventer, alu. bus bar etc. The panel shall be provided with interlocking arrangement between electric motor driven and dieselengine driven pumps so that only one pump can operate at one time and in case of any failure in electric motor driven pump the diesel engine driven pump shall operate automatically. The installation shall include all control wring, accommodation for battery charger etc. and connections as required |
| 220 | Incoming :1. No. 250 Amp 4 Pole MCCB, 35 KA 1 Set 300 Amp, 500V capacity 4 Nos. aluminium bus bar with epoxy insulator, heat shrink sleeve, required hole, nut bolt etc. 1 No. 96x 96 mm 0 to 500 Volt voltmeter selector switch and HRC fuse with base. 1 No. 96x 96 mm 0 to 300 Amp ammeter, selector switch and CT 1Set –3 nos. indicating lamp with HRC fuse and base Out goings :2 Nos. 200 Amp 4 Pole MCCB,25 KA2 Nos. 63 Amp 4 pole MCCB,10 KA.1 No. fully automatic star delta startersuitable for main pump motor I/C CT, ammeter with selector switch & control with pressure switch, pump ON indicating lamp.1 No. DOL starter suitable for jockey pump motor I/C CT, ammeter with selector switch. & control with pressure switch complete |
| 221 | Necessary cable alleys space for switches, internal wiring and copper earthing of all equipment willll also be included. All switch gears/control gears will be motor duty rating. |
| 222 | CABLES |
| 223 | S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer incharge of the site:- |
| 224 | Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 25-50sq.mm |
| 225 | Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core10-16sq.mm |
| 226 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPERCONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 2Core |
| 227 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPERCONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 228 | PRESSURE SWITCH |
| 229 | Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all restect |
| 230 | MS PIPE |
| 231 | Providing, laying, fixing, testing and commissioning of 'C' Class Medium duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 232 | 100 mm dia |
| 233 | 80 mm dia |
| 234 | ANGLE SUPPORTS |
| 235 | Providing and fixing of MS Angle on wall with suitable fastner of 12mm thick x 100mm long as required for pipe support. |
| 236 | CABLE TRAY |
| 237 | Supply and erection of hot dip G.I. cable tray perforation not more than 17.5% for specific dimensions along with tees, bends. The cable tray shall be hang from ceiling/ fixed to wall with necessary angle/flat iron/hanging rod, for ceiling suspensions, clamp, anchor fastener, nuts, bolts, washers, not more than 1.0 mtr. apart complete as per specification to complete the job. The tray shall be as follows :- |
| 238 | 100 x 50 x 1.6mm thick |
| 239 | 150 x 50 x 1.6mm thick |
| 240 | PRESSURE GAUGE |
| 241 | Providing and fixing Pressure Gauge complete as required complete in all respect. |
| 242 | Dial diameter 100mm calibration 0-16 Kg |
| 243 | BUTTERFLY VALVES |
| 244 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 245 | 150 mm dia |
| 246 | NON RETURN VALVE |
| 247 | Proving & fixing ISI Marked Dual Type Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc complete |
| 248 | 150mm dia(Dual Type NRV) |
| 249 | STRAINER |
| 250 | Supplying, Installation, Testing and Commissioning of cast iron flanged Y type strainer with stainless steel mesh in PN-1.6 including cost of Nut Bolt , rubber insertion complete in all respects. |
| 251 | For 200 mm dia |
| 252 | ALARM GONG BELL |
| 253 | Providing & Fixing of installation control valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve as per manufacturer's specifications complete. |
| 254 | 150mm dia |
| 255 | FIRE ALARM SYSTEM |
| 256 | PVC CONDUIT |
| 257 | PVC, HDPE PIPES & PVC FLEXIBLEPIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD GeneralSpecifications:- Medium Gauge PVC Conduit Pipe 25mmdia. (On Surface) |
| 258 | FIRE ALARM CONTROL PANEL |
| 259 | Fire panel : Providing, fixing, testing & commissioning microprocessor based main fire alarm panel and indicating panel solid state modular card type pulsar, timer for dual stage alarm facility with indicators, standby battery, complies to IS 2189:1999.2 x 16 character backlit LCD display lamp test features. Complete with integral power supply and battery charger for SMF battery. NO/NC contacts for both fireand fault. Switches to enable on board operation. LCD and LED Indication for open, short circuit, Isolate, fire in each zone. reset, lamp test, silence, isolate, short, open, fire continuous buzzer for fault and intermittent buzzer for fire battery charger box, operating voltage 220 Volt mains A.C. input/24V D.C. output etc. complete in all respect. 8 zone |
| 260 | Internal Fire Fighting Arrangment including Hydrant,Fire Extinguishers as per NBC Norms |
| 261 | MS PIPE |
| 262 | Providing, laying, fixing, testing and commissioning of 'B' Class Medium duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 263 | 100MM |
| 264 | UNDERGROUND MS PIPE |
| 265 | Providing, laying, fixing, testing and commissioning of 'C' Class Heavy duty MS Pipe (For External) conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. |
| 266 | 100 mm dia |
| 267 | ANGLE SUPPORTS |
| 268 | Providing and fixing of Tie Rod on ceiling with suitable fastner of as required for pipe support. |
| 269 | HYDRANT VALVE |
| 270 | Supplying, Installation, Testing and Commissioning of Stainless Steel Single headed hydrant valve with instantaneous SS coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 with blank Cap and chain complete in all respects. |
| 271 | Single Hydrant Valve |
| 272 | HOSE PIPE |
| 273 | Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with Stainless Steel male & female couplings (ISI marked) bound & riveted to hose pipes with GI rivets and GI wire as required. |
| 274 | BRANCH PIPE |
| 275 | Supplying, Installation, Testing and Commissioning 63 mm dia Stainless Steel Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Stainless Steel nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 276 | FIRST AID HOSE REEL DRUM |
| 277 | Providing and fixing first aid hose reel full swinging type including cabinet with 30 m length x 20 mm dia rubber lined pipe with ABS plastic shut off nozzle of 6 mm dia. The hose reel will conform to IS requirements. Rate will 25 mm dia pipe connection from riser to hose reel including flexible pipe, sockets, nipples, elbows . |
| 278 | HOSE CABINET |
| 279 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. 450 mm wide x 450 mm high x 250 mm deep Size. |
| 280 | BUTTERFLY VALVES |
| 281 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Stainless Steel seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 282 | 150MM |
| 283 | 100MM |
| 284 | NON RETURN VALVE |
| 285 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. |
| 286 | 150 mm dia |
| 287 | FIRE BRIGADE INLET |
| 288 | Providing and fixing fire brigade inlet connection of cast iron body with Stainless Steel 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. |
| 289 | Three Way Inlet Connection |
| 290 | AIR RELEASE VALVE |
| 291 | Supplying & fixing of Air release valves on top . |
| 292 | PRESSURE GAUGE |
| 293 | Providing and fixing Pressure Gauge complete as required complete in all respect. Dial dia 100 mm calibration 0-16Kg/cm2 |
| 294 | ABC STORED PRESSURE FIRE EXTINGUISHER |
| 295 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 296 | Capacity 4.0 kg. I.S.I. Marked. |
| 297 | CO2 GAS TYPE FIRE EXTINGUISHER |
| 298 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 299 | Capacity 4.5 kg. I.S.I. Marked. |
| 300 | BUCKET STAND |
| 301 | 4 buckets set with sand, self-supported M.S. stand i/cshed duly painted with red colour as per IS. |
| 302 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 303 | Triple Layer Tanks |
| 304 | 5000 Ltr x5 nos. |
| 305 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 306 | For 5000 ltr Water Tank |
| 307 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. |
| 308 | Class PN-1.0 as per ISI with gun metal flap |
| 309 | 100mm i/d Non-return valve |
| 310 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 311 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 312 | Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. |
| 313 | 32mm i/d Brass Ball valves |
| 314 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball |
| 315 | Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 316 | Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to beconnected to static tank). |
| 317 | Two Way inlet connection |
| 318 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 319 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 320 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325 |
| 321 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 322 | Suitable cement concrete foundation duly plastered and with anti vibration pads |
| 323 | 900 LPM AT 35 M HEAD Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender