Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58078638

Tender For Repair Of Plumbing Work Including Water, Sanitary Fittings, Soil,Tank Cleaning, Waste & Vent Pipes And Connected Plumbing B/R Works At Zone C At Mil Stn Raiwala Under Age(I) Raiwalaunder Age(I) Raiwala

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
9.10 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
3 days left
EMD
18200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Of Plumbing Work Including Water, Sanitary Fittings, Soil,Tank Cleaning, Waste & Vent Pipes And Connected Plumbing B/R Works At Zone C At Mil Stn Raiwala Under Age(I) Raiwalaunder Age(I) Raiwala

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-Nov-2026

BOQ

Name of Work:- Repair of Plumbing Work including water, sanitary fittings, soil,Tank cleaning, waste & vent pipes and connected Plumbing B/R works at zone C at Mil Stn Raiwala under AGE(I) Raiwalaunder AGE(I) Raiwala
Sl. No. Item Description
1Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land.Complete all as specified and directed
2Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge .Note : Ponding test after water proofing coating willl be done for ponding for 48 Hrs .
3M/L for 15 mm thick protection plaster CM 1:4 floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ).Complete all as specified and directed Note :- The rates of SBR quoted shall not be deemed to be included for these items and same will be seperately under respective item.
4M/L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge
5M&L for cement concrete 1:5:10 type E2(using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.Complete all as specified and directed
6M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in floor mixed with Liquied water proffing compound.Note :- WPC will be measured and paid seperately
7Supply only SBR Latex liquid polymer of approved make.
8Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required .
9S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.
10S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.
11S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
12S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
13S & F 75 mm bore PVC (SWR) bends of any radius
14S & F 110 mm bore PVC (SWR) bends of any radius
15S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
16S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
17S & F 75 mm bore PVC (SWR) Vent Cowl
18S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement
19S & F 110 mm bore PVC (SWR) P Trap
20S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement .
21S&F stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed.
22S&F stack clamps out of 40mmx 3 mm flat iron including bolts and nuts and securing ends of stays to walls or roof with fastner for 75 mm pipe, complete all as specified and directed.
23Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed.
24Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
25M&L for Non- skid coloured ceramic tiles of any design and pattern, 400X400X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects.Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE.Complete all as specified and directed
26M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects.Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I).Complete all as specified and directed
27M&L for chequered cement concrete tiles of size 30cm x 30cm x 22 mm thick with grey cment and pigment set and jointed in neat cement slurry and pointed in whicte or coloured cment tomatch the surface of tile over 20mm thick screed bed in CM 1:6 as in floor complete all as specifed and directed
28M&L for heavy duty coloured tiles (dark shade) with chequered, plain or recess finish at top of size 300X300X 8 to 10 mm thick as in floor /path/paving etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
29Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc.Complete all as specified and directed
30M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
31Cleaning of storage water storage tank of RCC/PVC of exc 250 but n. exc 500 Ltrs capacity staged over RCC roof/floor slab or similar place inside /outside buildings by removing float valves, inlet and outlet carefully, thoroughly cleaning the entire surface (internal & external), mouth of pipes etc scrubing with bleaching powder, to make the tank totally dirt free and finally cleaning the water tank with fresh water till water becomes clear to the entire satisfaction of Engineer-in-charge and as specified in particular specifications and refixing of float valves all as specified and directed by Engineer-in –Charge
32All as per above item here in before but water tank of capacity exc 500 but n. exc 1000ltrs
33All as per above item here in before but water tank of capacity exc 1000 but n. exc 2000ltrs
34Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
35M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6
36M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work
37M&l for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4
38Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
39Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .
40M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
41Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
42M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
43M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
44S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions.
45S & F in repairs Stop angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete (fixed in repairs) .
46S & F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule
47S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe
48S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms)
49S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union
50S & F , in repair, Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.
51Supply and fix in repair to glass corner shelf of size 300mm fixed with chromium plated brass brackets complete all as specified and directed.
52S&F in repair for PVC Connections 15mm size with PTMT nuts of length 600 mm
53S&F in repair Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting
54S&F in repair Wash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting
55S & F in repairs for Grating ,round 127 mm dia chromoum plated
56S&F in repair to 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers
57S & F in repairs Sinks with drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm.
58S & F in repair to Stainless steel kitchen plate rack 0.80mm thick sheet of over all size 31\\" x 30\\" x 10\\" fixed with steel screws and steel rawal plugs
59S&F in repairs to PVC Cabinet (box type) size (400 x 500 ) mm with looking mirror of selected quality glass having5.5 mm thick and fixed to walls with screws and wooden/rawl plugs ,complete all as specified and directed.
60S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed
61S&F in repairs Vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor .
62S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete
63M & L in repair S S Jet spray with 1.5 mtr braided tube complete all as specified and directed
64S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair.
65Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed.
66S&F in repairs Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia all as specified
67S&F in repair 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.
68Taking down cement plaster on brick , concrete or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed.
69M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed.
70M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over one coat of 1mm thick wall putty using roller all as specified and prescribed by manufacturer of paint Ist Quality and all as directed at site by Engr-in-Charge .
71M&L preparation of old painted surface of wall and applying one coat of oil bound distember all as specified
72M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v). The colour / shade will be all as approved by GE / AGE (I)
73M&L preparation of old painted surface on ceiling and applying one coat of oil bound distember all as specified
74M&L preparation of old painted wooden surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .
75M&L preparation of old painted steel surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .
76M&L preparation of old or plastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces
77Preparation Old painted concrete surface of any descroption surfaces exc. 10 cm width or girth and applying two coat of synthetic enemelled paint of any tint over a coat of primer incl. all preparation complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58078638
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.10 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Of Plumbing Work Including Water, Sanitary Fittings, Soil,Tank Cleaning, Waste & Vent Pipes And Connected Plumbing B/R Works At Zone C At Mil Stn Raiwala Under Age(I) Raiwalaunder Age(I) Raiwala
Basic Detail
Tender No 8172/E8
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 03 Nov 2026
Submission Date 10 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value 9.10 Lakhs
Tender Fee 500
EMD 18200
Exemption Available
Document List
1232ae13-cfd6-4897-87f2-50d628a43e8f.html
8172TD.pdf
BOQ_890833.xls
MAKEAPPROVAL.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

1232ae13-cfd6-4897-87f2-50d628a43e8f.html

pdf

8172TD.pdf

xls

BOQ_890833.xls

pdf

MAKEAPPROVAL.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender