Tender for Repair/Replacement Of Roof Leakage And Allied Works At Zone D At Mil Stn Raiwala Under Age(I) Raiwala
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. |
| 2 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with Liquid intergal water proofing compoud as per manufacturer direction and finishing the surface even and smooth with out using extra cement as in roof padding treatement to receive roof treatment complete all as specified and directed.Note :- liquid water proofing compound will be measured and paid seperately. |
| 3 | M/L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging ) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with Liquid intergal water proofing compoud as per manufactur direction )Note :- liquid water proofing compound will be measured and paid seperately. |
| 4 | Supply only Liquid intergal water proofing compoud |
| 5 | M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface. Note :- (i)The work is required to be carried out at non-accessible roof for double storey . (ii)The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these items. |
| 6 | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-(a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membranceNote : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. |
| 7 | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 1000 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. |
| 8 | Dismantaling RCC /PVC water tanks and S&F new rotational moulded polyethylene water storage tank 500 liters capacity, double layer (ISI Marked) construction (cylindrical vertical closed top), hoisted & fixed in position including S&F 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule complete all as specified and as directed. |
| 9 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia . |
| 10 | M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed |
| 11 | Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed |
| 12 | S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs. |
| 13 | Demolition of brick work built in cement mortar in any description and position complete all as specified and directed. |
| 14 | M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work |
| 15 | Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 |
| 16 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed. |
| 17 | M&L for coloured ceramic tiles (Joint free 7 to 8mm thick (square/rectangular) area of each tile exceeding .11 sqm but not exceeding 0.18 sqm,in floors etc,set and jointed in neat cement slurry and pointed in white coloured cement to match coloured tiles over and including 17 mm thick screed bed in CM (1:4) complete as specified and directed.Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I) |
| 18 | M&L for Glazed coloured ceramic tiles (joint free) in vertical surface,size 450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement tomatch coloured tiles over and including 12 mm thick rendering CM(1:4) complete as specified and directed.Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I) |
| 19 | M&L for Non skid ceramic tiles full body light shade 8-10 mm thick (square/rectangular) polished,area of each tiles exc .18 sqm but not exceeding 0.36 sqm,in vertical surfaces of dado/skirting etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM (1:4) complete as specified and directed.Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I) |
| 20 | Taking down cement plaster on brick , concrete or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 21 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v). The colour / shade will be all as approved by GE / AGE (I) |
| 23 | M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over one coat of wall puttyusing roller all as specified and prescribed by manufacturer of paint Ist Quality and all as directed at site by Engr-in-Charge .Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v). The colour / shade will be all as approved by GE / AGE (I) |
| 24 | M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished complete all as specified and directed. |
| 25 | M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge Note(i) The old/ New surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v) Before commencing the work, contractor will got the written approval from GE/ AGE (I) for the make and colour / shade (tint).(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor. |
| 26 | M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v). The colour / shade will be all as approved by GE / AGE (I) |
| 27 | M&L preparation of old painted wall surface including cleaning,scrapping/removal of loose and defective existing paint,surface preparation and applying one coat of approved quality oil bound distemper to walls including cornics,pillars etccomplete all as specified and directed. |
| 28 | M/L preparation of old surface of ceiling plastered including cornices and pillasters etc and applying one coat of white wash on ceiling all as specified and as directed by Engr-in-Charge. |
| 29 | M&L preparation of old painted wall surface including cleaning,scrapping/removal of loose and defective existing paint,surface preparation and applying one coat of approved quality cement based paint to walls complete all as specified and directed. |
| 30 | M&L preparation of old painted wooden surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed . |
| 31 | M&L preparation of old painted steel surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed . |
| 32 | M/L for writing letters/Bldg Nos or figures(Block, Roman or Indian) on wall 10cm height using synthetic enamel paint white or circular /black painted, black back ground all as specified and directred by Engg in charge |
| 33 | S&F in repair 20 mm dia ball valves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule and fixed.Make : ISI mark |
| 34 | M&L for preparation of old decorated surface of exterior wall and applying one coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc ) all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.Note(i) The old/ New surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of paint. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor. |
| 35 | Demolition and dismantling cast iron work any description complete all as specified and directed. |
| 36 | S&F Rolled mild steel work of Fe-290 (Gde E-165) as in framed work, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc |
| 37 | S & F Expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia., or fixing with steel staples to wood or steel members, weight not exceeding 4 Kg per Sq. M. |
| 38 | Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. |
| 39 | Dismantling / Demolition of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings |
| 40 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 41 | S&F 2 mm thick Fibre reinforced translucent plain sheeting with side lap fixed with coach screw and washer in roof / wall etc complete all as specified and directed by Engineer-in-charge. |
| 42 | Preparation Old painted concrete surface of any descroption surfaces exc. 10 cm width or girth and applying one coat of synthetic enemelled paint of any tint over a coat of primer incl. all preparation complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender