Tender For Construction Of Dining Hall With Master Kitchen And Store For 1000 Student At Govt. Ssd Girls High School Building Dongasil
Tender Value
2.40 Crore
Estimated cost
Bid Submission
29 Oct 2026
11 days left
EMD
2.41 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rayagada → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Dining Hall With Master Kitchen And Store For 1000 Student At Govt. Ssd Girls High School Building Dongasil
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in foundation in hard soil or gravelly soil within 50m intial lead and lifts 1.5 M intial lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site including cost of all labour, T&P and dewatering if required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 2 | Filling the foundation and plinth with course sand well watered and rammed etc complete complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 3 | Cement concrete of prop.(1:3:6) in foundation up to lowest bed level using hard black granite crusher broken metal of size 40 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6 thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc. complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 4 | RCC work of M-20 grade in the Structural building works using 20mm to 10mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including all taxes in complete.Footing |
| 5 | Column superstructure |
| 6 | Plinth Band |
| 7 | Lintle Band |
| 8 | Roof Beam |
| 9 | Chajja |
| 10 | Roof Slab |
| 11 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-550) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment) |
| 12 | Fly ash brick masonry in cement mortar (1:6) using bricks of 23cm size having a crushing strength of not less than 75 kg per Sq.cm, after immersing Bricks for six hours in waters before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge.Foundation and Plinth |
| 13 | Fly ash brick masonry in cement mortar (1:6) using bricks of 23cm size having a crushing strength of not less than 75 kg per Sq.cm, after immersing Bricks for six hours in waters before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge.Superstructure |
| 14 | 12 mm (1/2\\") thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge |
| 15 | 16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 16 | 6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-charge. |
| 17 | Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Vetrified floor tile of matt finish with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 18 | Supplying, fitting & fixing of 8-10 mm thick and size of 600x600 mm vertified wall tile of in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 19 | Supplying, fitting & fixing Granite Tiles in Floors of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 20 | Finishing wall surfaces with cement based putty (water based) of approved quality for making smooth even to receive painting including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 21 | Priming one coat with wall primer with water bond wall cement primer on plaster surface is complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 22 | Finishing Wall Painting two coats with plastic emulsion paint over a coat of water bond wall cement primer on plaster surface is complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 23 | Painting two coat of Weather coat over a coat of primer of approved shade on new works to give an even shade over prepared surfaces including scuffolding to outside walls, including cost and conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 24 | Supplying, fitting and fixing of M.S Grill gate ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) etc. complete in all respect as directed by the Engineer in charge. Door |
| 25 | Window |
| 26 | Providing and fixing ISI marked 32 mm thick flush door shutters conforming to IS:2202 decorative type, core of block board construction with frame of ist class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 27 | Supplying fitting fixing of two track UPVC sliding window track UPVC sliding window of approved make with 6 mm thick glass of approved quality complete with 6 mm thick glass of approved quality complete with frame including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 28 | Painting two coat with approved Synthetic enamel Paint on wood work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 29 | Painting two coat with approved Synthetic enamel Paint on steel work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 30 | Providing and laying Grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge |
| 31 | Dismentalling GCI or AC Sheet roofing after carefully removing the bolts and nuts including stacking the useful materials for reuse and removing the debris with in 50m lead including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 32 | Dismentalling brick masonary in cement mortar 3m. height including stacking the useful materials for reuse and removing the debris with in 50m lead including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 33 | Dismentalling and removing RCC columns, beams, slab, staircase, landing, lintles etc including stacking the useful materials for reuse and removing the debris with in 50m lead including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 34 | Dismentalling and removing lime concrete flooring 7.5 cm to 10 cm thick including stacking the useful materials for reuse and removing the debris with in 50m lead including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 35 | EI WORKSRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP A |
| 36 | GROUP-B |
| 37 | GROUP-C |
| 38 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 39 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 40 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 41 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 42 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 43 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 44 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIV Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 45 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X4) |
| 46 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(4X10+2X6) |
| 47 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 48 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 49 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 50 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 51 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (2'x2' 595x595x70mm) and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years. To be used in hall and dining area |
| 52 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.To be used in corridor, rooms, toilet area |
| 53 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 54 | SITC Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision - along with mounting of 1No.s Essential Glass T8 Base Tube 2200Lumen Pack,Efficacy >110Lm/W, 20Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 25K Burning Hours Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate.(Make: Panasonic/LT/Havells /Philips((TMC502 1xT-LED 22W))/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.for all Hostel Room & Corrider. |
| 55 | Supplying, Erection, Fixing, connection & testing of 100W FLOOD Light(120LM/W) For Building Premises Light of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 5 years warranty wit including MCB,stainless steel braket along with driver & including with Support as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 56 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 57 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 58 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DP plug & socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge. Make-Legrand/ Siemens/Schneider/ABB |
| 59 | 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 60 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 61 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 62 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 63 | Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 64 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 year. |
| 65 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 66 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 67 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 68 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm |
| 69 | 4core x 16 sq mm |
| 70 | 5 core x 10 sq mm COOPER armoured Cable For Kitchen Exhaust System. |
| 71 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 72 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 73 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 74 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 75 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x16sq mm |
| 76 | 3.5 core x50 sq mm |
| 77 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 78 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 79 | S/I/T&Commissioning of Main LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 kA. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders. |
| 80 | S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical UPS Outgoing panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.Mandatory provision of cable alley is to be given. |
| 81 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 82 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 83 | S/F of double battery of 150AH with 2KVA Inverter of Make Luminous/Exide/Sfsonic including all accessories and connection as per direction of Engineer-in-charge. |
| 84 | Supplying, installation, testing and commissioning of 30W electric insect killer (bug zapper) complete with all accessories. Make-iBell/Ubrighty/HiCare or equivalent |
| 85 | Supply, installation, testing and commissioning of factory fabricated unit floor mounted type fabricated out of extruded aluminum section with 0.6mm pre-plasticized / pre-coated Galvanized steel sheet outside. Motor Kw is indicative only, actual as per requirement to be included during installation.Cabinet type double skin Exhasut/Fresh Air Unit , with 25 MM thick Puf panel, 0.6 MM Pre coated Outer sheet & 0.6 MM plain inner sheet, complete with Fan section with DIDW centrifugal forward curved fan (with bearings mounted on the scroll and not on the fan casing) Fan motor, Class H, IP-55 rated motor , belt driven, drive guard, fan inlet with damper, base frame, spring type /turret mount vibration isolator, powder coated weather-proof canopy,The fan should be low noise level not exceding 55 dB(A) at 3 meter distance. Fan Motor shall be energy efficient squirrel-cage, totally-enclosed, fan cooled, standard frame, constant speed, continuous duty, single winding, suitable for 415 PLUS OR MINUS 10% volts, 50 cycles, 3 phase AC power supply, provided with class H insulation and 120 minutes fire rating. Motor shall be specially designed for quiet operation.The cost including the Panel for the Fans. Necessary copper earthing should also be included. Cabling and earthing as required from Fan Elec.Panel to Fan motor shall be considered as included in this scope & no separate measurements shall be considered for this lumpsum item.Fans shall be BMS compatible. The rate is inclusive of starter panel. The figure of CFM is indicative only, it shall be finalized after approval of final design and calculation by SE Electrical circle (R&B) and CE bdgs, O, BBSR. Make-Krugger/Airflow/NikotraAir Quantity :4500 CFM( FA ) Static Pressure : 30 mm wg |
| 86 | Supply, istallation, testing and commissioning of Single inlet single width (SISW) Kitchen exhaust fan of capacity 6000 CFM, total static pressure 58.8mm with 5hp IE2 foot mounted TEFC IP55 continous rated, insulation class 'F' with bare shaft and key as per IS 12615/IEC 60034-1 with centrifugal fan section having suction size 600mm outlet size 370x655mm with MS foundation frame, drain plug, GI coated nut and bolt in complete as per the direction of Engineer-in-charge.The rate is inclusive of starter panel. The figure of CFM is indicative only, it shall be finalized after approval of final design and calculation by SE Electrical circle (R&B) and CE bdgs, O, BBSR. Make of motor-ABB/Siemens/CG/Bharat Bijlee |
| 87 | PH WorksSupplying all materials, labour, T&P and providing Mat finish tiles in floors, treads and landing on 20mm thick bed of cement mortar 1:4 (1 cement:4 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. ( tile 600cmx600cm kajaria- Fogparla or equivalent makel to be pre-approved by the Engineer in charge) 20 mm CPVC (sdr-13.5) pipes (Oriplast/Supreme) |
| 88 | 25 mm CPVC(sdr-13.5) pipes (Oriplast/Supreme) |
| 89 | 32 mm CPVC sdr-13.5 pipes (Oriplast/Supreme) |
| 90 | 40 mm CPVC sdr-13.5 pipes (Oriplast/Supreme) |
| 91 | 50 mm UPVC sch-80 pipes(Oriplast/Supreme) |
| 92 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. |
| 93 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer-in-charge. |
| 94 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 95 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge..(Jaquar make/ Plaza Make/ Cera make/ Hindwere Make) 15mm dia CP Two way bib cock with Flange Jaquar FLP-5041PM |
| 96 | 15mm dia. nominal bore Long body Bib Cock Jaquar FLP-CHR-5037PM |
| 97 | 15mm dia CP angle stop cock with wall flange Jaquar FLP-CHR-5053PM |
| 98 | 15mm dia brass pillar cock Cat. No.- Jaquar FLP-CHR-5011PM |
| 99 | 25mm dia brass or gun metal full way valve (shakti make) |
| 100 | 32mm dia brass or gun metal full way valve (shakti make) |
| 101 | 40mm dia brass or gun metal full way valve (shakti make) |
| 102 | 15mm dia CP Extention Nipple |
| 103 | Providing and fixing circular type stainless steel jalli (grating) with hole for floor /nahani trap etc complete as per specification and direction of the Engineer in charge. |
| 104 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge. |
| 105 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge. 110mm diameter U-PVC SWR pipes(Oriplast type-B/Supreme) |
| 106 | 110mm U-PVC door Tee |
| 107 | 110mm U-PVC Socket |
| 108 | 110mm U-PVC door bend |
| 109 | 110mm U-PVC Plain tee |
| 110 | 110mm U-PVC S/Jn |
| 111 | 110mm U-PVC D/Jn |
| 112 | 110mm U-PVC plain shoe bend |
| 113 | 110mm U-PVC offset without wear |
| 114 | 110mm U-PVC vent cowl |
| 115 | 110mm U-PVC P- Trap |
| 116 | 110mm U-PVC plain bend |
| 117 | Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of the Engineer-In-Charge. |
| 118 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern of Hindware/Jaquar/Parryware with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer-in-charge. |
| 119 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. |
| 120 | Counter TOP Wash Basin |
| 121 | Supplying all materials, labour, T&P and fixing Flat back large pattern urinal of Hindware/Jaquar/Parryware the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls land making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Hindware Flat back large urinal cat no-60002 starwhite, Size-37.5x39x59 cm. |
| 122 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. |
| 123 | Long Size Mirror |
| 124 | Supplying all materials, labour, T&P and fixing standard size glass-shelf of Hindware/Jaquar/Parryware with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer-in-charge. |
| 125 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail 24\\" of Hindware/Jaquar/Parryware complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer-In-Charge |
| 126 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel ring complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge |
| 127 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge |
| 128 | Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 120 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC. |
| 129 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. |
| 130 | Supplying all materials, labour, T&P and providing Mat finish tiles in floors, treads and landing on 20mm thick bed of cement mortar 1:4 (1 cement:4 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. ( tile 600cmx600cm kajaria- Fogparla or equivalent makel to be pre-approved by the Engineer in charge) |
| 131 | Supplying all materials, labour, T&P and fixing provide glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. tile 600x300cm size kajaria-Duren marfil or equivalent make to be pre-approved by the Engineer in charge) |
| 132 | Supplying, fitting and fixing Granaite tile in floors of approved make conformaing to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. |
| 133 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 134 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender