Tender for Ordinary Repairs To Water Supply And Sanitary Arrangements In Ri Quarters At Panpozhi In Tenkasi District.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. |
| 2 | Brick work in following Cement Mortar 1:5 using best quality Burnt Clay Brick of size 8 3/4\\" x 4 1/4\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 3 | In Foundation and basement |
| 4 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 5 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 6 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means |
| 7 | Drilling 6\\" (150mm dia) vertical bore well in all soils & hard rock to any required depth as directed by the departmental officers including labour charges, for assembling of cashing pipe inserting in the drilled including welding the joints if necessary groting the caseing pipes etc., rig and supporting vehicle from one place to another. |
| 8 | 0-150, |
| 9 | Supplying and inserting PVC Casing pipe 6\\" dia borewell (6kg/sqcm) of best quality with ISI mark with necessary PVC coupling with socket end the PVC should got approved by the departmental officers before execution to work complete complying with standard specification and as directed by the departmental officers. |
| 10 | Supplying and fixing PVC End cap 6\\" 160mm dia borewell of best quality with ISI mark (The PVC endcap should be not approved by the departmnetal officers before execution.) |
| 11 | Supplying laying and jointing HDPE pipes class - V-1MP. a with working pressure of 10 kg./cm2 of approved quality and best quality conforming to ISS and with ISI mark of following sizes including cutting threading and fixing G.I. specials but including cost of such specials and fixing into Bore well for suction line, air pipe etc., complete complying with standard specification. |
| 12 | 32mm dia |
| 13 | Supplying and fixing of 2.00 HP submersibale pump set motor with 25 stage of approved |
| 14 | Supply of 3 Phase Panel Board items consisting 3.00 HP to 5.00 HP DOL starter with 32 Amp main including labour charges |
| 15 | 2 core 2.5 sq.mm armoured copper cable |
| 16 | Nylon Rope for Bore-well |
| 17 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. External Water supply - Above Ground Level |
| 18 | 25 mm dia |
| 19 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender