Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58077200

Tender For Replacement Of Old Non-Functional 30 Kva Ups At Hdu And Ot Complex Of Murshidabad Medical College & Hospital (Electrical Work)

Issued by Government Departments · Murshidabad, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Oct 2026
6 days left
EMD
10249
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Old Non-Functional 30 Kva Ups At Hdu And Ot Complex Of Murshidabad Medical College & Hospital (Electrical Work)

BOQ

Name of Work:- Replacement of old non-functional 30 kva UPS at HDU and OT Complex of Murshidabad Medical College & Hospital (Electrical Work)
Sl. No. Item Description
1Technical Specification for 30 KVA UPS 3phase input & 3 phase out put on line UPS systems [Make: POWER ONE, NUMERIC, Switching AVO,POWER ONE, ]
2Topology, IGBT BASED DSP CONTROLED
3Rating of UPS(KVA/KW): 20 KVA / 16 KW
4Input Voltage: 310----400----415 VAC 165-288 Volt /Phase(selectble)
5Input Frequency: 45 to 65 Hz
6Isolation Transformer: Inbuilt Isolation Transformer with 1:1 ratio at UPS Input to be provided at output
7Back feed Protection: UPS should have back feed protection
8Charging: Autometic float cum Boots Charging Capability with setteble flote & boost charging voltages and current levels and boots charger timer
9Output Voltage: 230 VAC
10Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3%
11Output Frequency: 50 Hz +/- 0.1%
12Output Power Factor: 0.8
13Crest Factor: 3:1
14THDu: < 2% (linear load), < 5%(non linear load)
15Waveform: Pure Sine Wave
16Birdge: Microprocessor based and IGBT Technology
17Overload: 110% for 60 minutes, 125% for 10 minutes, 150% for 30 sec
18Static By Pass: 100 % rated static switches with fuse protection overload on Bypass: 100% for 10 ms
19Overall Efficiency: 92%
20Battary Rack: With power coated MS angle with suiteble dimention and gadge.Useing Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress.
21Battery : 12 V, Mono Block batteries. SMF VRLA
22Protection: Multi Protection-Over Temperature Protection with 8 Sensors, Overload, Battery Under Voltage, Fan Failures ,Short Circuit. Four Circuit Breakers, Providing Full Protection When Fault, Strong Overload Capability. Surge Protector at Panel Input & EB Input. PV Reverse Polarity, Input Low & High Voltage, Output Low & High Voltage cut off. Glass cartridge Fuse on Control Circuits MCB at Input Panel,
23Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
24Metering: Graphical LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
25Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
26Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch
27Termination: Input, Battery, Output & Bypass
28Enclosure: IP 20
29Operating Temp: 0 to 40 Deg C
30Humidity: Upto 95% Rh (non-condensing)
31Cooling: Forced Air
32Noise: < 55 dB
33Cold Start : Provided
34CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
35ISO 9001: 2015, ISO 14001: 2015, ISO 45001:2018,ISO 50001;2018 , ISO:20000-1:2011,ISO:27001:2013, ROHS
36Warranty: Two Years on UPS on site against any Manufacturing defects[ Battery already installed, only old UPS will be replaced with new one] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58077200
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 24-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Replacement Of Old Non-Functional 30 Kva Ups At Hdu And Ot Complex Of Murshidabad Medical College & Hospital (Electrical Work)
Basic Detail
Tender No WBPWD/EE/MsdED/149/e-Q of 26-27
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 16 Oct 2026
Submission Date 24 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 10249
Exemption Not Available
Document List
40629e06-f03c-47db-9c48-3c1ccd41bd18.html
BOQ_5189330.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

40629e06-f03c-47db-9c48-3c1ccd41bd18.html

xls

BOQ_5189330.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender