Tender For Providing & Installing New Pumping Machinery, Providing, Laying, Pipe Line Distribution, House Connection, Development Of Water Works Site, Repair Of Existing Ohsr & Pump Chamber, Carriage Of Materials Complete In All Respects At Water Sup
Tender Overview
Project Description
Tender for Providing & Installing New Pumping Machinery, Providing, Laying, Pipe Line Distribution, House Connection, Development Of Water Works Site, Repair Of Existing Ohsr & Pump Chamber, Carriage Of Materials Complete In All Respects At Water Supply Scheme Garhi Tarkhana Block Shri Machhiwara Sahib Distt. Ludhiana. (Nabard Xxxi).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Oct-2026 | Corrigendum | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set 12.5 BHP capable of delivering 479 LPM against a head of 52 mtr (reputed make) complete in all respects as per standard Specifications. |
| 2 | Electric panel board consisting of electric appliances such as D.O.L Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. complete in all respects as per standard Specifications. |
| 3 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 4 | (xiii)) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 5 | (d)) Overall size 4.0sq.mm (56/0.3mm), 3Core |
| 6 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 7 | h) 80mm i/d |
| 8 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 9 | A) Class PN-1 as per ISI |
| 10 | a) 80mm i/d Sluice Valves flanged |
| 11 | c) 150mm i/d Sluice Valves flanged |
| 12 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 13 | a) Size 0.6 m. x 0.6 m. |
| 14 | b) Size 0.9 m. x 0.9 m. |
| 15 | Providing and installing 150 mm dia delivery main (FromTube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/FNRV Specials as C.I Bends,Tail Piece Tees, V-notch etc.. outside the pump chamber as per standard design complete in all respects. |
| 16 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 10kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 10 kg rising main 160 mm (Mechanical) |
| 17 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 63 mm o/d 6 kg/cm2 pressure |
| 18 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 75 mm o/d 6 kg/cm2 pressure |
| 19 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 90 mm o/d 6 kg/cm2 pressure |
| 20 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 110 mm o/d 6 kg/cm2 pressure |
| 21 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Mechanically excavaton) PVC pipe 160 mm o/d 6 kg/cm2 pressure |
| 22 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Manual excavation) PVC pipe 63 mm o/d 6 kg/cm2 pressure |
| 23 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Manual excavation) For 75 mm o/d PVC Pipe |
| 24 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling complete in all respects. (By Manual excavation) For 90 mm o/d PVC Pipe |
| 25 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 26 | i) 100mm i/d |
| 27 | Making proposed water connection to house hold upto wall with providing, laying, jointing, testing MDPE & G.I pipe line 15 mm i/d ( (2.0 m MDPE & 2.50 m G.I vertical = 4.50 m) including cost of specials such as tees, bends, sockets, elbow etc. cutiing, threading and testing in trenches in the group and ISI marked 15 mm i/d GM ferrule as per IS: 2692 and 3\\" i/d clamp with c.i.cock 15 mm i/d as per IS: 210 with stainless steel spindle of approved make complete. |
| 28 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. (for 63 mm o/d & 75 mm o/d) |
| 29 | Dismantling of Cement concrete road with 50mm to 75mm thick C.C 1:2:4 and making good the same to its original condition complete in all respects |
| 30 | Dismantling and Restoration of Interlocking Tile as per analysis attached. (For 63 mm i/d pipe) |
| 31 | Dismantling of metallic road with bituminous course 50 to 75mm thick C.C. 1:8:16 complete in all respects |
| 32 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. (for 90 mm o/d) |
| 33 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing. |
| 34 | Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing |
| 35 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing |
| 36 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing |
| 37 | Construction of masonry gate pillar including cost of MS Steel Gate size 2.44 mtr x 1.37 mtr as per standard Drawing complete in all respects |
| 38 | Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing |
| 39 | Providing & fixing MS Sign Board as per standard size of DWSS as per drawings. |
| 40 | Provision for one way stand post with Khura at water works site complete in all respects. |
| 41 | Pump Chamber Plinth protection complete in all respects |
| 42 | Repair of pump chamber complete in all respect |
| 43 | Construction of 75 kl OHSR plinth protection |
| 44 | Credit of old machinery |
| 45 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. |
| 46 | B) D.I. Pipe as per IS 8329 DI-K9 |
| 47 | (b)) 100mm i/d pipe lines laid complete(For overflow pipe) |
| 48 | Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects. |
| 49 | a) D.I. specials upto 300mm i/d |
| 50 | Construction of brick masonry 223 mm thick toe wall in 1:5 upto 0.90 m depth around water works site complete in all respect |
| 51 | Carriage of material such as Bajri & Sand upto lead 90km Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender