Power Government Departments Closing in 4 days TDR #58075746

Tender For Tender For Repair And Maintenance Of 33/11Kv, 2X1.6Mva S/Stn Killar To Attend The Observations Noticed During The Course Of P/Testing Of 33/11Kv, 2X1.6Mva S/Stn Killar Under Ed Killar Op Circle Hpsebl Dalhousie.

Issued by Government Departments · Chamba, Himachal Pradesh
Tender Value
19.86 Lakhs
Estimated cost
Bid Submission
24 Oct 2026
4 days left
EMD
19867
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamba → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Tender For Repair And Maintenance Of 33/11Kv, 2X1.6Mva S/Stn Killar To Attend The Observations Noticed During The Course Of P/Testing Of 33/11Kv, 2X1.6Mva S/Stn Killar Under Ed Killar Op Circle Hpsebl Dalhousie.

BOQ

Name of Work:- Tender for Repair and maintenance of 33/11kV, 2x1.6MVA S/Stn Killar to attend the observations noticed during the course of P/Testing of 33/11kV, 2x1.6MVA S/Stn Killar under ED Killar OP Circle HPSEBL Dalhousie.
Sl. No. Item Description
1Repair and maintainance of 33/11kV, 2x1.6MVA S/Stn Killar to attend the observations noticed during the course of P/Testing of 33/11kV, 2x1.6MVA S/Stn Killar
2Complete repair and overhauling of 33kv VCB complete in all respect as per satisfaction of Engineer-in charge.
3Repair and overhauling of existing 11kV indoor (VCB) circuit breaker trolleys by repairing the centre rod mechanism along with repair of tripping and closing coil mechanism complete job in all respect as per the satisfaction of Engineer-in charge.
4Providing service charges for rectification of leakage of 33/11kV 2x1.6MVA power transformers installed at 33/11kV, 2x1.6MVA S/Stn killar from various points such as radiators, HV bushes, LV Bushes and main tank complete in all respect.
5Providing dehydration charges for 33/11kV 2x1.6MVA power transformers.
6Providing mobility charger for dehydration machine.
7Providing paint of power transformers complete in all respect.:- Removing and cleaning old epoxy from transformer on all metal surfaces to remove all dirt grease , rust loose paint particle and making the surface even and clean with hand scraping complete in all respect.
8Providing paint of power transformers complete in all respect.:- Applying (primer) priming two coat on transfomrer with ready mixed primer grey matte finish gray EPILUX610 (Conforming to IS104) of approved band and manufacture on steel galvanized iron/steel works
9Providing paint of power transformers complete in all respect.:- spray two coat excluding two coat priming coat on transformer and other metal surface including cleaning of all surface dust,dirt and any other foreign matter with polyurethane /three silicon/paint other than white (light grey paint RAL 7035, conforming to IS 631; of IS 5 & 40-120 microne each ) complete in all respect
10Providing paint of power transformers complete in all respect.:- Extra item over item No. (3) for every subsequent coat of paint (a) with polyurethane other than white with polyrethane/silicon/paint coat conforming to IS 631 of IS: 5 & 40-120 microns each complete
11Providing hydra to carry out the dismantling and re-installing radiators or any other part of power transformer to carry out the above mentioned jobs.
12Replacement , providing, fixing, testing and commissioning of WTI & OTI ( Set containing one no. WTI and OTI Gauge) for 33/11kV , 2x1.6MVA power transformers I & II.
13Providing , fixing , testing and commissioning of battery bank 30V, 200Ah at 33/11kV , 2x1.6MVA S/Stn Killar , complete in all respect as per the satisfaction of the Engineer-in charge.
14Providing and Fixing Fire Extinguisher DCP 10/9kg capacity
15Providing and Fixing Fire Extinguisher Mech Foam 50Ltr
16Providing and Fixing Fire buckets with stand (4 nos.)
17Repair , Re-alignement and replacement of damaged parts of 33 KV Isolator (without earth switch
18Repair , Re-alignement and replacement of damaged parts of 33 KV Isolator (with earth switch
19Providing & fixing 18W LED lamp complete with fitting
20Providing & fixing of Isolator 11 KV 630 Amp, 25 KA with earth swicth Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58075746
AUTHORITY Government Departments
TENDER VALUE 19.86 Lakhs
LAST DATE 24-10-2026
Authority
Authority Name Himachal Pradesh State Electricity Board
Work Description Tender for Tender For Repair And Maintenance Of 33/11Kv, 2X1.6Mva S/Stn Killar To Attend The Observations Noticed During The Course Of P/Testing Of 33/11Kv, 2X1.6Mva S/Stn Killar Under Ed Killar Op Circle Hpsebl Dalhousie.
Basic Detail
Tender No Bid No. OCD/DB/Bid-39/2026-27
Bidding Type Tender
Location
City Chamba
State Himachal Pradesh
Key Dates
Publish Date 16 Oct 2026
Submission Date 24 Oct 2026
Open Date 27 Oct 2026
Finance
Tender Value 19.86 Lakhs
Tender Fee 590
EMD 19867
Exemption Not Available
Document List
051c5be8-40f6-45ba-8fcc-651a3002c81d.html
BOQ_217177.xls
SBD_Revenue_Bid_39.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

051c5be8-40f6-45ba-8fcc-651a3002c81d.html

xls

BOQ_217177.xls

pdf

SBD_Revenue_Bid_39.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender