Tender For Renovation Of Toilets, Kitchens And Adjoining Areas Of C-Block Including Electrical Works & Replacement Of External Sanitary Lines At Csir Scientist Apartments, Maharani Bagh, New Delhi.
Tender Value
82.23 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
5 days left
EMD
1.64 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Toilets, Kitchens And Adjoining Areas Of C-Block Including Electrical Works & Replacement Of External Sanitary Lines At Csir Scientist Apartments, Maharani Bagh, New Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats,architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below . |
| 3 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Cutting holes up to 15x15 cm in R.C.C. floors/wall and roofs for passing drain pipe etc. including breaking the existing concealed pipe and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 4 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 75 to 80 mm dia pipe. |
| 5 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe. |
| 6 | Dismantling C.I or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead: upto150mm dia pipe |
| 7 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles upto 10 mm |
| 8 | Dismantling tile work in walls fixed with cement mortar including stacking material within 50 metres lead. For thickness of tiles upto10 mm. (Entire backing mortar/plaster 30mm av.(20-40mm) to be removed i/c making good the base/brick surface, if got damaged) |
| 9 | Demolishing cement concrete including disposal of material within 50 metres lead as per direction of engineer in charge.Nominal concrete 1:3:6 or richer mix(including equivalent design mix) |
| 10 | Demolishing R.C.C. work (facias) manually including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer- in- charge without disturbing the adjoining structural elements. |
| 11 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) of any size including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 12 | Dismantling W.C. pan/Wash Basin/Sink etc. of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-inCharge. |
| 13 | Dismantling of CP brass bib-cock/angle valve/concealed/wash basin mixer etc of all types including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 14 | Dismantling of CP/PTMT towel rail/shelf etc including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 15 | Dismantling G.I./cpvc pipes (internal work) including excavation and refilling after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge:15 mm to 20 mm nominal bore. |
| 16 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 17 | Chipping of unsound/weak concrete material from slabs, beams,columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges,making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness. |
| 18 | Chipping of unsound/weak concrete material from slabs, beams,columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges,making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 50 mm average thickness. |
| 19 | Filling up the cracks in plaster work upto 3mm wide x 5mm deep in 02 coats (i.e., application of 2nd coat on next day after complete contraction of 1st coat) with crack filler paste of Nerolac Perma/Asian smart care crack seal or equivalent. The crack lines in plaster shall be made wide in V-shape with necesary tools prior to filling of crack seal paste. Thereafter, the crack line shall be finished smooth in line with the existing plaster surface.The work shall be carried out with the help of any working base platform or scaffolding if required. Nothing extra will be paid for working platform/scaffolding used in the work. |
| 20 | Providing and fixing hard drawn steel wire fabric of size 25 x 25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \\"L\\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. (Weight not less than 2.0 kg/sqm). |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type B, including jointing with solvent cement adhesive complete all as directed by the Engineer- in - charge (i) Single socketed pipes. 110 mm SWR PVC Pipe. |
| 23 | Providing and fixing on wall face unplasticised Rigid PVC SWR fitting conforming to IS : 13592 Type B, including jointing with solvent cement adhesive complete all as directed by the Engineer- in - charge : 110X110X100 mm plain tee. |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC SWR fitting conforming to IS : 13592 Type B, including jointing with solvent cement adhesive complete all as directed by the Engineer- in - charge : 110 mm Bend without door. |
| 25 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : uPVC SWR Type B conforming to IS: 13592. 110 mm x 110 mm. |
| 26 | Providing and fixing on wall face unplasticised Rigid PVC SWR fitting conforming to IS : 13592 Type B, including jointing with solvent cement adhesive complete all as directed by the Engineer- in - charge : 110 mm cowl. |
| 27 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - rigid uPVC SWR pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm. |
| 28 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 29 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 30 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 31 | Extra for concrete work in superstructure above floor V level for each four floors or part thereof. |
| 32 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level : cement mortar 1:4 (1 cement : 4 coarse sand). |
| 33 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. |
| 34 | Providing and fixing 18mm thick gang saw cut mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Rajnagar plain white marble / Udaipur green marble /Zebra black marble. Area of slab over 0.5 sqm. Udaipur Green marble over 0.5 sqm. |
| 35 | Extra for fixing marble / granite stone over and above coresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 36 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). : Sal wood |
| 37 | Providing and fixing 19 mm thick commercial board for making storage cabinet, almirah or providing shelve/partition/shutter etc wherever required including fixing wooden margins on exposed edges with necessary screws,adhesive etc as per direction of Engineer In Charge. |
| 38 | Providing & Fixing 6mm thick commercial plywood in pannelling, partitions, almirahs etc with nails, adhesives etc complete |
| 39 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessary screws etc., complete |
| 40 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 41 | Providing and fixing Ist quality rectified ceramic glazed wall tiles of size 450 mm x 300 mm (or as required) conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes. |
| 43 | Making Connection of new CPVC pipelines with existing main G.I/ CPVC lines i/c making suitable holes, providing and fixing CPVC MT Adaptor/Unions etc. |
| 44 | Providing and fixing C.P. brass long body bib cock of approved quality (as per enclosed 'List of Make') conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. |
| 45 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality (as per enclosed 'List of Make'): 15mm nominal bore. |
| 46 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make (as per enclosed 'List of Make'). 15 mm nominal bore. |
| 47 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 48 | Providing and fixing 32mm CP brass waste of standard pattern in wash basins/sinks. |
| 49 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 50 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 450x300x150 mm. |
| 51 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 600x450x200mm . |
| 52 | Providing and fixing white vitreous china pedestal type (European type/wash down type) water closet pan. |
| 53 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid. |
| 54 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white |
| 55 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 56 | Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia. |
| 57 | Grouting of sunken area floor trap in toilet/kitchen with neat cement punning after proper cleaning to make it leakage proof and water tight. |
| 58 | Making connection of drain or sewer line with existing GT chamber including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes upto 110 mm diameter. |
| 59 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 60 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter. |
| 61 | Providing and applying single coat of anti corrosive coating such as zinc epoxy primer of thickness to the exposed reinforcing bars as per manufacturer's specifications and direction of Engineer-in-charge (area of reinforcement bars surface shall be taken for measurement). |
| 62 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. |
| 63 | Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above and below plinth level. Thermo-Mechanically Treated bars. |
| 64 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand i/c 6mm down coarse aggregates) with SBR polymer 10-20 % by wt. of cement used as per manufacturer's specifications. The work has to be carried out in 02 layers and directions of Engineer-in-charge. 25 mm average thickness. |
| 65 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand i/c 6mm down coarse aggregates) with SBR polymer 10-20 % by wt. of cement used or as per manufacturer's specifications. The work has to be carried out in 03 layers and irections of Engineer-in-charge. 50 mm average thickness |
| 66 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 67 | Providing and fixing uplasticised PVC connection pipe with brass unions 45cm length : 15 mm nominal bore. |
| 68 | Providing and fixing PTMT swivelling shower with arm , 15 mm nominal bore, weighing not less than 40 gms |
| 69 | Providing and fixing CP brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and make. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 350 gms. |
| 70 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 71 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg. |
| 72 | Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg |
| 73 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 74 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 75 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 76 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 77 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 78 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 79 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives (Apex ultima or equivalent) of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). Consumption may vary as per manufacturer's specifications. |
| 80 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.110 mm diameter pipes. |
| 81 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 82 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated olyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 83 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 84 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 85 | Providing and fixing 6mm thick HDHMR board of density 800 kg/cum (action tesa/ century/ greenply), wherever required in kitchen cabinets/cubboards for shelf/ partition/shutters of required size and also for supports of Shelf/partition etc. The front side of all the edges visible in the shelf/partition etc are to be lipped 1mm thick PVC sheet using solvent cement etc. complete as per direction of Engineer-in- charge and manufacturer's specifications. (Piano hinges for shutters will be paid for seperately). |
| 86 | Forming groove of uniform size in the top layer of external plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 25 mm wide and 20 mm deep groove |
| 87 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transportincluding loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 88 | Rewiring for light / fan / exhaust fan / call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel / PVC conduit including dismantling as required. Group A. |
| 89 | Supplying and fixing of following size of medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm. |
| 90 | Supplying and fixing of following size of medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (b) 25 mm |
| 91 | Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC Conduit as required.(a) 2 x 2.5 Sq. mm + 1 x 2.5 Sq. mm earth wire. |
| 92 | Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC Conduit as required.(b) 2 x 4 Sq. mm + 1 x 4 Sq. mm earth wire. |
| 93 | Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC Conduit as required.(c) 2 x 6 Sq. mm + 1 x 6 Sq. mm earth wire. |
| 94 | Wiring for circuit / sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC Conduit as required.(d) 2 x 10 Sq. mm + 1 x 6 Sq. mm earth wire. |
| 95 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. (a) 3 x 1.5 Sq. mm. |
| 96 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. (b) 3 x 2.5 Sq. mm |
| 97 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. (c ) 3 x 4.0 Sq. mm |
| 98 | Supplying and drawing following sizes of FRLS PVC insulated coper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.(d) 3 x 6.0 Sq. mm |
| 99 | Supplying and fixing following piano type switch / socket outlet on the existing switch box / cover including connections etc as required. (a) 5/6 Amp Switch |
| 100 | Supplying and fixing following piano type switch / socket outlet on the existing switch box / cover including connections etc as required. (b) 3 Pin 5/6 Amp Socket Outlet |
| 101 | Supplying and fixing following piano type switch / socket outlet on the existing switch box / cover including connections etc as required. (c) Bell push |
| 102 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 103 | Supplying and fixing metal box of 180x100x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 no 3 pin 5/6 Amp piano type socket outlet and 1 no 5/6 Amp piano type switch, connections, painting etc as required. |
| 104 | Supplying and fixing of defective 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker including supply suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 105 | Supplying and fixing of defective 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker including supply suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) Single pole and neutral |
| 106 | Supplying and fixing PVC Batten / angle holder including connections etc as required. |
| 107 | Supplying and fixing metal box of 150x75x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 Amp piano type socket outlet and 5/6 Amp piano type switch, connections, painting etc as required. |
| 108 | Supplying and fixing metal box of 180x100x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 Amp piano type socket outlet and 15/16 Amp piano type switch, connections, painting etc as required. |
| 109 | Supplying and fixing of hylum sheet 3 mm thick including supply in the existing switch / socket MS Box etc complete in all respect. |
| 110 | Supplying and fixing metal box of 180x100x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 111 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. (a) Upto 450mm sweep |
| 112 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safe pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.white colour as required. (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) . |
| 113 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB / RCCB / Isolator) (a) 8 Way, Double door |
| 114 | Supplying and fixing of DP sheet steel enclosure on surface / recess alongwith 25/32 Amp 415 Volts \\"C\\" Curve DP MCB complete with connections, testing and commissioning etc as required. |
| 115 | Supply, installation, Testing and Commissioning of bright line 20 W LED Batten (Cool day light) 240 V, fitting (Phillips) or Garnet 22 W LED Batten (Wippro) Lighting fitting on surface / recess complete with all accessories i.e, lamp / driver etc complete in all respect. |
| 116 | Supplying and fixing metal box of 180x100x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 1 no 3 pin 5/6 Amp piano type socket outlet and 1 no 15/16 Amp piano type socket outlet, connections, painting etc as required. |
| 117 | Supplying and fixing metal box of 180x100x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 1 no 3 pin 5/6 Amp piano type switch and 1 no 15/16 Amp piano type switch, connections, painting etc as required. |
| 118 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 119 | Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm lonf, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc as required. |
| 120 | Providing and fixing of GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizantal run). |
| 121 | Providing and fixing of GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For Vertical run) |
| 122 | Providing and fixing testing joint, made of 20 x 3 mm thick GI strip, 125 mm long with 4 number of GI bolts, nuts, chuck nut and spring washer etc complete as required. |
| 123 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. |
| 124 | Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connections with GI nut, bolts, spring, washer excavation and refilling etc as required. |
| 125 | Jointing copper / GI tape (with another copper / GI tape, base of the finial or any other metallic object) by riveting / nut bolting / sweating and soldering etc as required. |
| 126 | Buy back of dismantled kitchen/toilet flush door shutters including all the fittings i.e. tower bolts , sliding door bolt etc.and taking the same out of campus .- Of area less than 3.0 sqm. |
| 127 | Buy back the CI pipe with fittings and taking that out of campus .75mm dia |
| 128 | Buy back the CI pipe with fittings and taking that out of campus .100mm dia |
| 129 | Buy back the CI pipe with fittings and taking that out of campus .150 mm dia |
| 130 | Buy back of GI pipe with fittings, obtained from dismanting work and taking that out of campus. 15 mm to 20 nominal bore dia. |
| 131 | Buy back of CP brass sanitary fittings such as short /long body bib cocks, concealed stop-cock, angle valve, basin mixer etc. dismantled from toilets and kitchens. 15 mm nominal bore. |
| 132 | Buy back of W.C. pan/Wash Basin/Sink etc. of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-inCharge. |
| 133 | Buy Back of CP/PTMT towel rail/shelf etc including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 134 | Buy back of flushing cistern with internal old dismantled fittings complete |
| 135 | Salvage value of dismantled / old MCB Distribution board with single pole & SPN MCB upto 12 way including din bar, earth bar, wiring etc \\"As is where is basis\\" |
| 136 | Salvage value of dismantled / old metal box upto 180x100x60 mm including switches(5/15 A), sockets (5/15 A), hylum sheet, callbell, buzzer, wiring etc \\"As is where is basis\\" |
| 137 | Salvage value of dismantled / old ceiling fan 1200 sweep with regulator, wiring etc \\"As is where is basis\\" |
| 138 | Salvage value of dismantled / old flouresent light fittings, wiring etc \\"As is where is basis\\" Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender