Tender For Upgradation Of Halogen Type Agl Fittings To Led Fittings Including Miscellaneous Works For Taxiways, Apron Stands And Secondary Runway At Nscbi Airport Kolkata.
Tender Overview
Project Description
Tender for Upgradation Of Halogen Type Agl Fittings To Led Fittings Including Miscellaneous Works For Taxiways, Apron Stands And Secondary Runway At Nscbi Airport Kolkata.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Nov-2026 | Corrigendum1 | Date | 12-Nov-2026 |
| 2 | 10-Nov-2026 | Corrigendum2 | Date | 19-Nov-2026 |
| 3 | 02-Nov-2026 | Corrigendum1 | Date | 12-Nov-2026 |
| 4 | 18-Nov-2026 | Corrigendum III | Date | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application,, energy efficient Inset, Bidirectional, single lead LED TAXIWAY CENTRE LINE Light for straight / Curve section suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Color, Straight/ curve (left/right), Narrow/wide beam etc. as per site requirement and design. |
| 2 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient Inset, Bidirectional, Double lead LED TAXIWAY CENTRE LINE Light for straight / Curve section suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Color, Straight/ curve (left/right), Narrow/wide beam etc. as per site requirement and design. |
| 3 | Supply of FAA certified or its model variant or FAA complied for ICAO CAT III all weather operation application, Elevated, Omnidirectional energy efficient Blue, LED TAXIWAY/ APRON EDGE Light suitable for 6.6 Amps AFL secondary circuits, complete with its base plate, breakable coupling, mounting assembly, gasket, scratch resistant and shatter proof lens, LED modules with optics, integral fully potted driver, fail-open relay based/signal interface, electronics, heat sink / treatment for Indian environment, hardwares, installation kit, bird spike, cable lead with plug, ready for site installation and compatible to existing ALCMS/ILCMS, as per specifications etc. complete as required. |
| 4 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, omnidirectional Yellow-LED AIRCRAFT STAND MANOEUVRING GUIDANCE Light for straight / Curve section suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required. |
| 5 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, unidirectional Red-LED AIRCRAFT STAND MANOEUVRING STOP Light for straight section suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required. |
| 6 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, unidirectional Yellow-LED INTERMEDIATE HOLDING POSITION Light for straight section suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required. |
| 7 | Supply of FAA certified or its model variant or FAA complied for ICAO CAT III all weather operation application, Elevated, unidirectional energy efficient yellow LED RUNWAY GUARD Light with two fitting having site controllable flash control unit suitable for 6.6 Amps AFL secondary circuits, complete with its black independent visors, base plate, breakable coupling, mounting assembly, gasket, scratch resistant and shatter proof clear lens, LED modules with optics, integral fully potted driver, fail-open relay based/signal interface, electronics, heat sink / treatment for Indian environment, hardwares, installation kit, bird spike, cable lead with plug, ready for site installation and compatible to existing ALCMS/ILCMS, as per specifications etc. complete as required. |
| 8 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, Bidirectional, LED RUNWAY EDGE Light suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Color, inbuilt toe-in etc. as per site requirement and design. |
| 9 | Supply of FAA certified or its model variant or FAA complied for ICAO CAT III all weather operation application, Elevated, Bidirectional energy efficient high intensity LED RUNWAY EDGE Light suitable for 6.6 Amps AFL secondary circuits, complete with its base plate, breakable coupling, mounting assembly, gasket, scratch resistant and shatter proof clear lens, LED modules with optics, integral fully potted driver, fail-open relay based/signal interface, electronics, heat sink / treatment for Indian environment, hardwares, installation kit, bird spike, cable lead with plug, ready for site installation and compatible to existing ALCMS/ILCMS, as per specifications etc. complete as required.NB: Color, inbuilt toe-in etc. as per site requirement and design. |
| 10 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient Inset, Bidirectional, LED RUNWAY CENTERLINE Light suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Color as per site requirement and design. |
| 11 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, Unidirectional, LED RUNWAY CENTERLINE Light suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Color as per site requirement and design. |
| 12 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, green Unidirectional, LED RUNWAY THRESHOLD Light suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Inbuilt toe-in etc. as per site requirement and design. |
| 13 | Supply of FAA certified or its model variant or FAA complied, for ICAO CAT III all weather continuous operation application, energy efficient, Inset, red Unidirectional, LED RUNWAY END Light suitable for 6.6 Amps AFL secondary circuits, complete with its shallow base, Mounting kit, Earthing kit, LED modules, relay based/signal interface fail-open, fully potted driver, electronics, heat sink, saphire / reinforced prism for abraison proof, seals, pressure relief test plug, cable lead with plug, ready for site installation and compatible to existing ILCMS, etc. complete as required.NB: Inbuilt toe-in etc. as per site requirement and design. |
| 14 | Supply of FAA certified /complied, airfield ground lighting cable, 1Cx 6 sq. mm, 5 KV grade, multi stranded tinned copper conductor, tinned copper braid shielded (maximum shield resistance shall not be more than 5 ohm / KM at ambient temperature of 50 degree Centigrade), XLPE insulated with extruded inner semiconductor and taped outer semiconductor layer compatible to existing ILCMS etc. complete as required. |
| 15 | Supply of FAA certified /complied, 2C x 4 sq.mm. 600V grade flexible annealed tinned copper conductor secondary cable for Airport lighting circuits compatible to existing ILCMS etc. complete as required. |
| 16 | Supply of FAA certified /complied 6 sq. mm size, 5 KV grade dry type plug and receptacle of type I, class 'B' primary connector kit (L-823 style 3 & 10 of FAA AC) with field attachment and suitable for shielded airfield cable with earthing glands, nuts and bolts and IS marked 1X4 sq. mm tinned copper insulated earth continuity wire, copper thimbles and compatible to the existing ILCMS as per specifications etc. as required. |
| 17 | Supply of FAA certified /complied, Secondary connector kit (L-823 style 5 & 12 of FAA AC) suitable for connection 2X 4 sq. mm multi stranded annealed conductor, unshielded secondary airfield lighting cables as per specification etc. complete as required. |
| 18 | Supply of FAA certified or its model variant or FAA complied, for earth type following rating isolating transformer, 5 KV grade, 50 Hz, Low leakage inductance (Not more than 50 microhenry), direct burial in earth for use of series airport lighting circuits suitable for power line communication with existing ALCMS / ILCMS etc. complete as required.45 Watt, 6.6/6.6 Amp |
| 19 | Supply of FAA certified or its model variant or FAA complied, for earth type following rating isolating transformer, 5 KV grade, 50 Hz, Low leakage inductance (Not more than 50 microhenry), direct burial in earth for use of series airport lighting circuits suitable for power line communication with existing ALCMS / ILCMS etc. complete as required.65 Watt, 6.6/6.6 Amp |
| 20 | Supply of FAA certified or its model variant or FAA complied, for earth type following rating isolating transformer, 5 KV grade, 50 Hz, Low leakage inductance (Not more than 50 microhenry), direct burial in earth for use of series airport lighting circuits suitable for power line communication with existing ALCMS / ILCMS etc. complete as required.100 Watt, 6.6/6.6 Amp |
| 21 | Supply of Fire retardant Yellow/Green 4 sq. mm Single Core PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables 1.1 kV grade confirming to IS 694:2010 etc. complete as required. . |
| 22 | Design fabrication, supply of MS isolating transformer housing box of size 750(L)X350(W)X550 (D) as per site requirement for load bearing capacity of a rolling category-E aircraft made out of 6 mm (min.) thick MS sheet and counter sunk top cover 10 mm thick (min.) MS sheet, necessary top coveer supports, extended earth studs both for fittings as well as GI wires and ASD / TRF hanging arrnagement, cutting of holes etc. All inserts should be suitable for M-10 size bolt i/c supply of M 10 SS Bolts and nuts including painting of box with one coat of primer & two coats of black enamel paint and installation with concrete work / existing trench in soil / in gravel (excluding concrete or excavation work) along with water drainage connection at bottom, including sloping as per DGCA CAR requirement, pipe fixing, Final painting after installation, lettering, numbering and as per the direction of Engineer-In-Charge etc. complete as required. |
| 23 | Excavation of the trench in soft soil by use of hydraulic excavator exceeding 30cm in depth and not exceeding 1.5 mtr in width, and lift upto 1.5 mtr, including back filling as directed by the Engineer-In-Charge. |
| 24 | Excavation of the trench in hard rock or bituminous / cement concrete of runways /taxiways/ apron/RESA/ Road etc. by power saw cutting without disturbing the other area, upto 1.5 mtr in width, and depth upto 1.0 mtr, including getting out the excavated debris, cleaning the cut area and disposal of excavated debris as directed within a lead of 5 KM including all machineries like power saw, hammer drill / pneumatic drill, water browser, mobile DG set, transportation etc. complete as required. |
| 25 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering and shuttering, propping etc. as required and removel of form work etc. as required as per the site condition. |
| 26 | Supply and Laying of 1 run X 40 mm dia (OD) HDPE pipe (PE-63, PN-6, UV stabilized, conforming to IS 4984 with IS mark) along with laying of 4mm dia PP rope through the pipe, providing end cap at one end and end cap or GI / PVC box (Minimum size 100mmX100 mm X 75 mm) at other end before PQC/bitumen work as applicable, along with all necessary accessories like socket, bend, couplers etc., if required, by cutting the DRLC/concrete/bitumen/gravel of groove size at least 60mm(W) X 100mm (D) using cutting saw machine, MS clamping the pipe and back filling, rolling etc. including all required transportation, generator, water arrangement etc. complete as required as per the direction of Engineer-In-Charge. |
| 27 | Supply and Laying of 1 run X 40 mm dia (OD) HDPE pipe (PE-63, PN-6, UV stabilized, conforming to IS 4984 with IS mark) along with laying of 4mm dia PP rope through the pipe complete with fitting, cuttings, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering alongwith its necessary accessories like socket, bend, coupler etc., if required, complete as required as per the direction of Engineer-In-Charge. |
| 28 | Supply and Laying of 1 run x 63-mm dia (OD) HDPE pipe (PE-63, PN-6, UV stabilized, conforming to IS 4984 with IS mark) alongwith its necessary accessories like coupler,end plugs etc., if required, below the ground (i/c Road crossing, Cement concrete Apron Area) at a depth of 3.5 m to 6 m through horizontal directional drilling after doing Ground Penetrating radar survey, along with laying of 4mm dia PP rope through the pipe and submitting its report of the Underground Utilities etc. complete as required as per the direction of Engineer-In-Charge. |
| 29 | Laying of one number PVC insulated & PVC sheathed armoured / unarmoured aluminium / copper conductor AFL / power cable of voltage grade exceeding 1.1 KV but not exceeding 11 KV of size not exceeding 25 sq. mm. in the existing cable duct / masonry trench / pipes etc. as required, including IR testing to comply DGCA CAR / ICAO, establishing shield continuity and replacing the cables if IR values is found less than as per ICAO requirement. |
| 30 | Laying of one number PVC/XLPE insulated & PVC sheathed armoured / unarmoured AFL / power cable of voltage grade not exceeding 1.1 KV of size not exceeding 25 sq. mm. along with earth cable in the existing cable duct / masonry trench /pipes etc. as required including megger testing and replacing the cables if IR values is found less than as per ICAO requirement or if instructed by Engineer-In-Charge. |
| 31 | Making connection of 5 KV grade , 6 Sq. mm Copper conductor Screened cable with plug & receptacle, 1 X 4 sqmm. tinned copper insulated earth continuity wire, copper lugs for screen , earth point of transformers and IT box body earthing etc. complete as required by engaging competancy mapped OEM trained manpower. The job includes supply and taping (75mm long with 50% overlap) of two layer of HT then two layer of PVC tapes at every junction/water ingress point of connection including opening and retaping as required to establish the shield continuity suitable for existing ILCMS. |
| 32 | Making connection of 2 X 4 sq. mm multi stranded copper conductor secondary airfield lighting cables with secondary connector kit (plug and receptacle) etc complete as required by engaging competancy mapped OEM trained manpower. The job includes supply and taping (75mm long with 50% overlap) of two layer of HT then two layer of PVC tapes at every junction/water ingress point of connection. |
| 33 | Providing laying and fixing 6 SWG dia G.I. wire on surface or in recess (in existing pipe and/or along with submain wiring/cable) for loop earthing etc.complete as required. |
| 34 | Kerf cutting with machine in taxiway/runway/apron of PQC/bituminous surface of depth upto 90 mm and width minimum 20 mm, using expansion joints / construction joints as far as possible, cleaning, drying, disposing FODs as directed by E-I-C including laying 1 or 2 nos secondary lead/LT cable, earth wire ( generally conforming ICAO Doc- 9157, Part-5) by wrapping cotton tape with 50% overlapping, providing suiable sealant for airfield application i.e polysulphide or polyurethane as applicable, primar, backer rod (on top and bottom) along with arranging water bowser, dust arrestor, blower, mobile DG sets etc. complete as required to work in an operational airport. |
| 35 | Kerf cutting with machine in taxiway/runway/apron of PQC/bituminous surface of depth upto 110 mm and width minimum 20 mm, using expansion joints / construction joints as far as possible, cleaning, drying, disposing FODs as directed including laying 3 or 4 nos secondary lead, earth wire ( generally conforming ICAO Doc- 9157, Part-5) by wrapping cotton tape with 50% overlapping, providing suiable sealant for airfield application i.e polysulphide or polyurethane as applicable, primar, backer rod (on top and bottom) along with arranging water bowser, dust arrestor, blower, mobile DG sets etc. complete as required to work in an operational airport. |
| 36 | Core cutting at cement / asphaltic area like runways/ taxiways/ apron etc.at the designated location as per the existing fittings coordinates / approved design, outer core suitable for 200 mm dia inset fittings as per site requirement upto the depth as per OEM installation manual and then upto the existing cable duct / pipe end with 90-100 mm inner core cutting , arranging power supply with the help of DG sets and water arrangement , removing core and retrieving the pipe rope suitable for cable pulling condition from the bottom as applicable, cleaning, disposing debris upto 5 KM away, etc. complete as required including suitable cover for plugging the holes and handing over as ready for inset fittings installations etc. complete as required. |
| 37 | Core cutting at cement / asphaltic area like runways/ taxiways/ apron etc.at the designated location as per the existing fittings coordinates / approved design, outer core suitable for 300 mm dia inset fittings as per site requirement upto the depth as per OEM installation manual and then upto the existing cable duct / pipe end with 90-100 mm inner core cutting , arranging power supply with the help of DG sets and water arrangement , removing core and retrieving the pipe rope suitable for cable pulling condition from the bottom as applicable, cleaning, disposing debris upto 5 KM away, etc. complete as required including suitable cover for plugging the holes and handing over as ready for inset fittings installations etc. complete as required. |
| 38 | Installations of 200 mm dia shallow base can by using OEM (of fitting) manufactured jig engaging competancy mapped OEM trained manpower preceded by GPS based survey of the approved design coordinates complying to ICAO / DGCA CAR requirement. The job includes supplying and fixing 75mm OD HDPE pipe in inner core up to the pipe at bottom as applicable, epoxy quick setting grouts like nitomortar-S at bottom and dobefil on sides, arranging water & DG power supply, cleaning, disposing debris upto 10 KM away etc. complete as required including installation, testing and commissioning of inset fittings, connections with isolating transformers, ASD, earthing connections, fittings and fixing numbering and meggering etc. complete as required. |
| 39 | Installations of 300 mm dia shallow base can by using OEM (of fitting) manufactured jig engaging competancy mapped OEM trained manpower preceded by GPS based survey of the approved design coordinates complying to ICAO / DGCA CAR requirement. The job includes supplying and fixing 75mm OD HDPE pipe in inner core up to the pipe at bottom as applicable, epoxy quick setting grouts like nitomortar-S at bottom and dobefil on sides, arranging water & DG power supply, cleaning, disposing debris upto 10 KM away etc. complete as required including installation, testing and commissioning of inset fittings, connections with isolating transformers, ASD, earthing connections, fittings and fixing numbering and meggering etc. complete as required. |
| 40 | Installation testing commissioning of elevated type AGL fitting on existing MS box/collar including connection with islation transformer, addressable switching device etc.as applicable, all materials required for connection excluding supply of IT, ASD etc. complete as required. |
| 41 | Dismantling of existing inset/elevated AGL fitting from the existing shallow base (for inset fitting)/housing box (for elevated fitting) along with isolation transformer, secondary cable (as much as possible), addressable switching device if applicable and as per site requirement, shorting the existing primary cable leads, checking the serviceability of the fitting, IT with required rectification (excluding supply of spares/consumables), keeping the materials in safe custody and handing over to AAI at the end of project or in phases as directed by Engineer-in-Charge etc. and submission of report complete as required. |
| 42 | Dismantling of existing shallow base of AGL inset fitting, from flexible/rigid pavement, chiselling out the concrete /bitumen /Polyeurethene /Dobefil etc. as applicable, ensuring the its serviceability for reuse, keeping in safe custody and handing over to AAI at the end of project or in phases as directed by Engineer-in-Charge etc. and submission of report complete as required. |
| 43 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing enclosure of size 750mm x 350 mm x 550 mm ( H) made out 6 mm thick MS sheet and top cover 10 mm thick MS sheet ( counter shunk fitting, M-10 nuts and bolts.), welding, having locking arrangement and watering arrangement etc. with charcoal/ coke and salt as required. |
| 44 | Photometric test at site of all the installed fittings, signs by use of FAA certified mobile vehicle mounted photometric tester, arranging vehicle, engaging of competancy mapped OEM (of photometric instrument) trained engineers, generation of signed report then and there at site for submission to DGCA till their satisfaction for commissioning level approval including any retesting, repairing, cleaning, realigning etc. as required, carrying out photometric retesting of any sample(s) as demanded by DGCA/Engineer-In-Charge. |
| 45 | GPS based Total Station Survey as and when required depending upon site availability for the AGL fittings and other accessories as required for pin pointing core cutting locations, fittings installations etc. including submission of GFC drawing and carrying out final survey marking the coordinates at site and submission /resubmission of Commissioning level document, As built Drawing with coordinates, test certificates for DGCA approval (wherever applicable) etc. complete as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.