Educational and Research Institute Government Departments Closing in 16 days TDR #58074880

Tender For Replacement Of Indian Commode Into The Western, Exterior Painting And, Renovation Of Washrooms And Other Maintenance Works In Boys Hostel( B.No-78) At Aiims Rishikesh.

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
94.13 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
16 days left
EMD
4.70 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Indian Commode Into The Western, Exterior Painting And, Renovation Of Washrooms And Other Maintenance Works In Boys Hostel( B.No-78) At Aiims Rishikesh.

BOQ

Name of Work:- Replacement of indian commode into the western, Exterior painting and, Renovation of washrooms and other maintenance works in Boys Hostel( B.No-78) at AIIMS Rishikesh.
Sl. No. Item Description
1Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
2Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
3Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats
4Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
5Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
6Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self-curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
7For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
8Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading.
9Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
11Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
12Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
13Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
14Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
15Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15mm C.P. brass pillar tap
16Providing & fixing White vitreous china water closet squatting pan (Indian type) along with“S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm.
17Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer all complete
18Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved or anywhere in the campus as per dirction of Engineer in charge.
19Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931, 15mm nominal bore
20Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.
21Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead, 100 mm dia pipe.
22Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour, 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
23Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
24Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approvedquality and colour, weighing not less than 300 gms
25Providing and fixing PTMT robe hook strip with 5 hooks, fixed on wall / behind door, complete with concealed fitting arrangements, of approved quality and colour, weighing not less than 250 gms, including all fixing accessories, complete as directed by Engineer-in-Charge
26Providing and fixing 0.8 mm thick GI/Aluminium sheet on washroom doors, including cutting, bending, fixing with suitable screws/adhesive, and making all joints neat and flush, for protection of doors from water, complete in all respects as per site requirement and directions of the Engineer-in-Charge
27Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabilityfor hot & cold water supply, including all CPVC plain & brass threaded fittings and fixingthe pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the sameincluding testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes
28Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabilityfor hot & cold water supply, including all CPVC plain & brass threaded fittings and fixingthe pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the sameincluding testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
29Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stabilityfor hot & cold water supply, including all CPVC plain & brass threaded fittings and fixingthe pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the sameincluding testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes
30Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making goodthe walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cuttingchases and making good the wall, 20 mm dia nominal bore.
31Providing and fixing 100 mm diameter SWR type B Rigid PVC pipes conforming to IS :13592 Type B, including fixing with necessary with necessary clamps, tees, brackets, bends, jointing with solvent conforming to IS : 5382, (i) Double socketed pipes, 100MM dia meter, pressure bearing capacity 6 Kg/ sqcm
32Providing and fixing white vitreous china flat back or wall corner type lipped front urinalbasin of 430x260x350 mm or 340x410x265 mm sizes respectively.
33Providing and fixing uplasticised PVC connection pipe with brass unions, 30 cm length, 15 mm nominal bore
34Taking out doors, windows and clerestory window shutters (steel or wood) including stackingwithin 50 metres lead, Of area 3 sq. metres and below.
35Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws andapplying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
36Providing and fixing 1 mm thick M.S. sheet door with frame made of 40×40×6 mm angle iron and 3 mm thick M.S. gusset plates at all junctions and corners, complete with all necessary fittings including an in-built locking arrangement (integrated lock system), and applying one coat of approved steel primer, complete in all respect, Using M.S. angels 40x40x6 mm for diagonal braces
37Supply and fixing 15 mm C.P. brass tap
38Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
39Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5in superstructure above plinth level up to floor V level, Cement mortar 1:4 (1 cement :4 coarse sand)
4015 mm cement plaster on the rough side of single or half brick wall of mix, 1:6 (1 cement: 6 fine sand)
41Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and wellmatched commercial 3 ply veneering with vertical grains or cross bands and face veneers onboth faces of shutters, 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
42Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) withnecessary screws etc. complete (Copper oxidised as per IS 1378), 250x10 mm
43Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessaryscrews etc. complete (Copper oxidised as per IS 1378), 125 mm
44Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc.complete (Copper oxidised as per IS 1378), 300x16 mm.
45Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
46Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
47Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required, 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
48Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required, 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
49Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
50Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
51Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
52Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 Pin 15/16 A socket
53Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
54Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
55Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
56Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module
57Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module
58Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
59Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
60Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator),6 way , Double door
61LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter und/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19,Flicker free, (flicker should be below 5 %), life time(LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 12 -15 watt
62LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150 watt
63Supplying of following sizes of PVC/XLPE insulated PVC sheathed copper, armoured, cable of 1.1KV grade, as per IS applicable complete as required. Make : Polycab/Havells/KEI/Finolex, 3X1.5 sq mm
64S/F of of Below mentioned size Ventillator fan suitable for 220volts A.C. supply on the existing opening i/c connection & testing etc. as required. Make: Crompton Greaves / Havells /Bajaj 225 mm
65Dismantling & taking away the scrap of burnt all sizes fans/fittings/conduits/MS boxes/GI boxes/cable tray/Al cables/Copper Cables/Misc. scrap of Electrical items (against credit) in following forms:- 5A/15A/Switch/Socket
66Dismantling & taking away the scrap of burnt all sizes fans/fittings/conduits/MS boxes/GI boxes/cable tray/Al cables/Copper Cables/Misc. scrap of Electrical items (against credit) in following forms:-Iron Scrap (Metal Box and conduit, Iron Angle etc.)
67Dismantling & taking away the scrap of burnt all sizes fans/fittings/conduits/MS boxes/GI boxes/cable tray/Al cables/Copper Cables/Misc. scrap of Electrical items (against credit) in following forms:-Old LED Lights
68Dismantling & taking away the scrap of burnt all sizes fans/fittings/conduits/MS boxes/GI boxes/cable tray/Al cables/Copper Cables/Misc. scrap of Electrical items (against credit) in following forms:-Old Exhaust Fan pvc size 225mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58074880
AUTHORITY Government Departments
TENDER VALUE 94.13 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Tender for Replacement Of Indian Commode Into The Western, Exterior Painting And, Renovation Of Washrooms And Other Maintenance Works In Boys Hostel( B.No-78) At Aiims Rishikesh.
Basic Detail
Tender No 34/EE/Civil/2026-27
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 15 Oct 2026
Submission Date 05 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 94.13 Lakhs
Tender Fee Ref. Documents
EMD 4.70 Lakhs
Exemption Not Available
Document List
19baa6ee-94df-40c9-bd3d-3b6a45216d94.html
BOQ_977944.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

19baa6ee-94df-40c9-bd3d-3b6a45216d94.html

xls

BOQ_977944.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender