Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58074362

Tender For repair maintenance Electrical & Mechanical Services At Residential Flats / Bunglow At Rajpur Road, Civil Lines, Delhi-110054. (Sh :- Renovation Works In 33/A-3, 17/17, 17/19, 17/3,47/15,47/13 And Another Four Number Quarters As And When Re

Issued by Government Departments · Delhi, Delhi
Tender Value
88.99 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
4 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance Electrical & Mechanical Services At Residential Flats / Bunglow At Rajpur Road, Civil Lines, Delhi-110054. (Sh :- Renovation Works In 33/A-3, 17/17, 17/19, 17/3,47/15,47/13 And Another Four Number Quarters As And When Required According To Civil Works At Rajpur Road).

BOQ

Name of Work:- RMO Electrical & Mechanical Services at Residential flats / Bunglow at Rajpur Road, Civil Lines, Delhi-110054. (Sh :- Renovation works in 33/A-3, 17/17, 17/19, 17/3,47/15,47/13 and another Four Number quarters as and when required according to Civil Works at Rajpur Road).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group B
3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
4Group B
5Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
6Group B
7Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
83 x 1.5 sq. mm
93 x 4 sq. mm
103 x 6 sq. mm
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1220 mm
1325 mm
14Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
154 X 10 sq. mm + 2 X 6 sq. mm earth wire
16Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
171 or 2 Module (75mm X 75mm)
183 Module (100mm X 75mm)
196 Module (200mm X 75mm)
208 Module (125mm X 125mm)
2112 Module (200mm X 150mm)
22Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
231 or 2 Module
243 Module
256 Module
268 Module
2712 Module
28Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
295/6 A switch
3015/16 A switch
313 pin 5/6 A socket outlet
326 pin 15/16 A socket outlet
33Bell push
3425 A Modular SPMCB
35Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
36Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
37Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
38Supplying and fixing call bell suitable for single phase, 230 V, complete as required.
39Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
408 way (4 + 24), Double door
41Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
42Single pole
4363 A Triple pole and neutral
44Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim.
4512 - 15 watt
46Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin),
47SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
4812 -15 watt
49Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
5036 watt
51Supply, Installation, Testing and Commissioning of 1200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
52Supply, Installation, Testing and Commissioning of Decorative / Fancy 1200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. (Design , Colour and Make will be decided by Engineer in charge).
53Supplying, Installation, Testing and Commissioning of 150 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
54Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
55Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
56Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
57Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
58Supplying, Installation, Testing & Commissioning of minimum 5 watt / meter LED strip light including driver having colour temperature 3000K - 6500K etc complete as required (CCT shall be decided by Engineer-in-Charge).
59Supplying, Installation, Testing & Commissioning of minimum 3 watt, IP 65 LED Step / foot light having colour temperature 3000K- 6500K etc complete as required. (CCT shall be decided by Engineer-in-Charge).
60Supplying, Installation, Testing & Commissioning of 3 to 7 watt ,IP 65 LED out door 2 way wall light having colour temperature 3000K - 6500K etc complete as required (CCT shall be decided by Engineer-in-Charge)
61Supplying, installation, testing & commissioning of following capacity water storage vertical /horizontal type geyser working on 230 +/- 10 V single phase 50 Hz Frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, mltifactional sefety valve complete with necessary accessories & flexible heavy duty pvc connection of sutiable length (2 Nos.) and 25 amp plug top etc, as reqd.
626 ltrs. Rating Minimum 4 star
6325 ltrs. Rating Minimum 4 star
64SITC of Auto Clean Chimney Curved Glass electrical chimney with decorative frame of steel body structure having width of 600 mm,air suction capacity minimum 1200 cubic Meter/hr, having auto clean , touch sensor, metal blower, metal housing, oil collector, heat auto cleaner, touch panel, curved glass etc i/c providing & fixing 6 inch alu. pipe ( 3 mtr ) , 6 inch cowels & clamp etc as reqd.
65SITC of 6-10W LED Wall Light / bulb base E27 /polished finish type/ having colour temp. 3000K - 6000K etc complete as required (Color/shape/size will be decided by Engineer-in-charge).
66SITC Water Pressure Booster Pump 0.5 HP/0.37 kW, 220V AC, 50 Hz, Pipe size: 25X25 mm, Maximum Flow Rate: 2910 Liters Per Hour, Maximum Lifting Height: 22 Metres
67Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
68150 watt
69Supplying, Installation, testing and commissioning of 8-11 Watt LED Mini Bollard fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 65, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.90, CRI > 80, Luminaries efficacy ≥ 70 lumen/watt , Driver efficiency > 85%, L-70 Life 50,000 burning hours. i/c CC foundation of suitable size with foundation bolt complete as required. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
70Supply, installation, testing and commissioning of following watt LED Decorative post top fitting with aluminium die cast housing, Polycarbonate / Pamma prismatic clear/frosted diffuser with operating range of 100-270V, PF> 0.95, luminious efficiency > 100 lumens/watt, CCT 3000k-6500k (CCT shall be decided by Engineer-in-charge), IP 65 with 4KV surge protection i/c connections & interconnections etc as required.
7125 watt
7240 watt
73Supplying & Laying 3 x 10 Sq.mm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in existing DWC/GI/pipe/on surface or loose for connection and testing etc as reqd.
74SITC of LED Channel System with Milky White Cover Lens, Silver Aluminum Extrusion Profile Housing Diffuser Track for Strip Tape Light i/c making connection complete as reqd.
75Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 25 mm dia. and l0 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 50 kg ( 10 kg Bag x 5) resistivity is less than 0.12 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement including cost of petty material required to complete the job in all respect.
76Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
77Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,
7813) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS.
794MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens
80Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.
8115) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection :
82(intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.29) Built-In Artificial IntelligenceNVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan,cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics
8316 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
84Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
8510TB (Terabytes)
86Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.
8732 inch or larger
88Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, NMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
8924 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min
90Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required
919 U Rack
92Supplying, drawing, Installation, Testing and commissioning of armoured CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface,/in ground etc. complete as required. i) 1 Run of cable
93Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
94Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. i) Copper Patch Cords of length 1m (3ft)
95Supplying, Installation, Testing and commissioning of corner Trendy Illumina Premium Aluminium Wall Washer Profile Light,| Linear LED Housing for Wall Washing & Skirting Design (LED Strip Included) etc complete as required. (Design, Color, shape, size will be decided by Engineer-in-charge).
96SITC of Victorian Glow Decorative Wall Lights, Gold colour, Flush mount, energy efficient, colour Changing, adjustable Colour Temperature, Bulb base E14, Metal Material, Glass shade Material, Transparen Shade colour, Removable Fixture Type having colour temp. 3000K - 6000K etc complete as required (Design, Color, shape, size will be decided by Engineer-in-charge).
97Supplying of following materials for day to day maintance required for resdl.qtr
981.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
994.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
10020 mm iron staples/ saddles/ screws
10125 mm iron staples/ saddles/ screws
10220 mm diA, ISI marked, PVC conduit
10325 mm diA, ISI marked, PVC conduit
10420 mm PVC bends
10525 mm PVC bends
10620 mm PVC junction box, two way
1073 mm thick phenolic laminated sheet
108S.P. 5/6 A, one way modular switch, ISI marked
109S.P. 15/16 A, one way modular switch, ISI marked
1103 pin 5/6 A modular socket outlet, ISI marked
1116 pin 15/16 A modular socket outlet, ISI marked
112Modular bell push, ISI marked
113Stepped type Modular Fan regulator (2 module)
114Modular blanking plate
115Modular base & cover plate for 2 module
116Modular base & cover plate for 3 module
117Modular base & cover plate for 6 module
118Modular base & cover plate for 8 module
119Modular base & cover plate for 12 module
120call bell, Single phase
121PVC Batten/ Angle Holder
1224 pole MCCB,125A,36kA Ics=100% Icu and Operational Voltage 690V
12325 A modular SPMCB, 'C' curve
1246 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity
125LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
12612 - 15 watt
127LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
1285 -7 watt
129LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) of following body materials. CRCA Sheet Body (Thickness > 0.50 mm)
13018-22 watt
13136 watt
132LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) of following body materials.
13370 watt
134Modular plastic box for 2 module
135Modular plastic box for 3 module
136Modular plastic box for 6 module
137Modular plastic box for 8 module
138Modular plastic box for 12 module
1392.5 mfd capacitor
14020 mfd capacitor
1411200 mm ceiling fan
142400 mm Wall fan
143300 mm Exhaust fan
144150 mm fresh air fan
145200 mm fresh air fan
146250 mm fresh air fan
1476A top plug
14816A top plug
1492W cob light
15063A DP
15163A TPN
152DP Encloser
153FP Encloser
154monoblock Pump 1 HP/0.746 kW, 220V AC, 50 Hz, having suction and delivery 40 x 40 mm, discharge 0.6 to 1.8 LPS, having head of 17 to 23.
155submersible/monoblock pump DOL control panel suitable for 3/5 HP 3 Phase having Ammeter, Voltmeter, Selector Switch, Single phase priventer complete with sheet steel enclosure, indicator light, ON/OFF push button, auto, manual switch
156440V 50 Hz 3 Phase Star-delta starter panel suitable for 10 HP Open-well motor pump set having Ammeter, Voltmeter, Selector Switch, Single Phase Priventer
157Less credit for old dismantled material received from site
158Assorted Copper wire/Cable
159Assorted conduit
160Assorted Switch/Socket/bell push/fan regulator/modular base & cover plate/ceiling rose
161Assorted GI Box
162Assorted TPDB
163Assorted ceiling fan
164Assorted fitting
165Assorted fresh air/exhaust fan/wall fan
166Assorted MCB
167Assorted Post top Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58074362
AUTHORITY Government Departments
TENDER VALUE 88.99 Lakhs
LAST DATE 23-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Electrical & Mechanical Services At Residential Flats / Bunglow At Rajpur Road, Civil Lines, Delhi-110054. (Sh :- Renovation Works In 33/A-3, 17/17, 17/19, 17/3,47/15,47/13 And Another Four Number Quarters As And When Required According To Civil Works At Rajpur Road).
Basic Detail
Tender No 57/2026-27/EMD M-351/EE(E)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 16 Oct 2026
Submission Date 23 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 88.99 Lakhs
Tender Fee Ref. Documents
EMD 1.77 Lakhs
Exemption Not Available
Document List
57TenderNotice.pdf
b802e98f-2c19-4827-b691-bed22468802f.html
BOQ_400497.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

57TenderNotice.pdf

html

b802e98f-2c19-4827-b691-bed22468802f.html

xls

BOQ_400497.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender