Housing Urban and Rular Development Government Departments Closing in 7 days TDR #58074361

Tender For repair maintenance Electrical & Mechanical Services At Officers Da Flats/Bunglow At 6/8 Lancer Road-110054. (Sh - Renovation Works electrical installation Works).

Issued by Government Departments · Delhi, Delhi
Tender Value
35.79 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
7 days left
EMD
71593
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance Electrical & Mechanical Services At Officers Da Flats/Bunglow At 6/8 Lancer Road-110054. (Sh - Renovation Works electrical installation Works).

BOQ

Name of Work:- RMO Electrical & Mechanical Services at Officers DA Flats/Bunglow at 6/8 Lancer Road-110054. (Sh - Renovation works EI Works).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group A
3Group B
4Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
5Group A
6Group B
7Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
83 x 1.5 sq. mm
93 x 4 sq. mm
103 x 6 sq. mm
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1220 mm
1325 mm
14Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
151 or 2 Module (75mm X 75mm)
163 Module (100mm X 75mm)
176 Module (200mm X 75mm)
188 Module (125mm X 125mm)
1912 Module (200mm X 150mm)
20Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
211 or 2 Module
223 Module
236 Module
248 Module
2512 Module
26Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
275/6 A switch
2815/16 A switch
293 pin 5/6 A socket outlet
306 pin 15/16 A socket outlet
31Bell push
3225 A Modular SPMCB
33Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
34Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
35Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
36Supplying and fixing call bell suitable for single phase, 230 V, complete as required.
37Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3812 way , Double door
39Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
408 way (4 + 24), Double door
41Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
42Single pole
4363 Amp Double pole
44Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim.
4512 - 15 watt
46Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
4736 watt
48Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
49100 watt
50150 watt
51Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
5250 watt
53Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
54Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
55Supplying and fixing PVC batten/ angle holder including connections etc. as required.
56Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
5763 mm dia (OD-63 mm & ID-51 mm nominal)
58Supplying, Installation, Testing & Commissioning of SMC pole Box of size 140mm x 140mm x 95mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
59SITC of Fancy wall bracket fitting with retrofit LED bulb 7-9 watt complete with all accessories i/c LED bulb etc. directly on wall i/c connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting). (Sample Approved by Engineer-in-charge before installation at site).
60SITC of 6W 3-in-1 color changing full copper finish LED mirror wall light having colour temp. 3000K - 6000K etc complete as required (Color/shape/size will be decided by Engineer-in-charge).
61Supplying, Installation, testing of commissioning of 75 XL Desert Air Cooler For Home with Honeycomb Pads, Powerful +Air Fan, i-Pure Console and Low Power Consumption etc complete as required.
62Supply, Installation, Testing and Commissioning of 1200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
63Supply, Installation, Testing and Commissioning of Decorative / Fancy 1200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. (Design , Colour and Make will be decided by Engineer in charge).
64Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
65Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
66Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
67Supplying, installation, testing & commissioning of following capacity water storage vertical /horizontal type geyser working on 230 +/- 10 V single phase 50 Hz Frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, multifactional safety valve complete with necessary accessories & flexible heavy duty pvc connection of suitable length (2 Nos.) and 25 amp plug top etc, as reqd.
686 ltrs. Rating Minimum 4 star
6925 ltrs. Rating Minimum 4 star
70SITC of Auto Clean Chimney Curved Glass electrical chimney with decorative frame of steel body structure having width of 600 mm,air suction capacity minimum 1200 cubic Meter/hr, having auto clean , touch sensor, metal blower, metal housing, oil collector, heat auto cleaner, touch panel, curved glass etc i/c providing & fixing 6 inch alu. pipe ( 3 mtr ) , 6 inch cowels & clamp etc as reqd.
71SITC Water Pressure Booster Pump 0.5 HP/0.37 kW, 220V AC, 50 Hz, Pipe size: 25X25 mm, Maximum Flow Rate: 2910 Liters Per Hour, Maximum Lifting Height: 22 Metres
72S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
7345 watt
74Supplying laying and fixing of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following size on existing DWC Pipe / Sufrace/ Open duct / ground etc as required
753 x 10 sqmm
764 x 25 sqmm
77SITC monoblock Pump 1 HP/0.746 kW, 220V AC, 50 Hz, having suction and delivery 40 x 40 mm, discharge 0.6 to 1.8 LPS, having head of 17 to 23. complete etc. as reqd.
78Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 25 mm dia. and l0 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 50 kg ( 10 kg Bag x 5) resistivity is less than 0.12 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement including cost of petty material required to complete the job in all respect.
79SITC of submersible/monoblock pump DOL control panel suitable for upto 5 HP suitable for Phase having Ammeter, Voltmeter, Selector Switch, Single phase priventer complete with sheet steel enclosure, indicator light, ON/OFF push button, auto, manual switch i/c connection testing credit of old dismantle etc. as reqd.
80SITC of 4Mtr decorative combo pole made out of cast iron base of 625mm long and top 76mm G.I. Pipe. The pole having integral connection box duly cover the same. Connection box built in bakelite plate, 4way heavy duty connector, din channel suitable for SPMCB. The Pole shall be primer & painted with polyurethane paint as approved colour finish i/c making suitable size RCC foundation with foundation bolt etc.
81SITC of Double arm bracket made out of different section of mild steel tubes, joints Cast Alum embellishment suitable for Post-Top fitting. The bracket should be primer & painted with polyurethane paint above matching pole etc as reqd.
82SITC of 40W LED Post Top made out of die cast aluminum housing, Spun Aluminium PC/PMMA diffuser is provided for glare free lighting with 2/3 casted aluminum arms fixture shall be powder coated / PU painted in approved colour fitting of having following features: Total system lumen output should be minimum 4000, Luminous efficacy 100 lm/watt, CCT = 3000-6500K, CRI 80,Surge protection device > 4KV, IP 65 housing, electronic driver, as per specification given in terms and conditions etc. complete as required. As per drawing attached in size of fitting may be allowed ±5%.complete i/c dismantling of existing defective part and credit for the same as reqd
83SITC of Ornamental Bollard Light made out of Cast Iron / Cast Alum. with Integral Connection box and Top luminaires hexagonal 12-18 Watt LED IP-65 fully weather proof made of aluminium die cast housing, size of fitting 385mm x 225mm with opal polycarbonate protector duly silicon filled, U.V. resistant P.U. / Powder coated paint, Lacquer coated, as approved colour finish with highly effacing electronic external driver, high voltage protection, power LED mounted on MCPCB. The MCPCB mounted on aluminium heat sink for better heat dissipation arrangement duly wired up to connector complete etc. as reqd.
84S.I.T.C of 6-10 W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminium body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and comissioining etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
85Less credit for old dismantled material received from site
86Assorted Copper wire/Cable
87Assorted Size Al. Cable upto 35 sq.mm
88Assorted Switch/Socket/bell push/fan regulator/modular base & cover plate/ceiling rose
89Assorted GI Box
90Assorted TPDB
91Assorted ceiling fan / fresh air/exhaust fan/wall fan
92Assorted fitting
93Assorted MCB
94Assorted Post top Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58074361
AUTHORITY Government Departments
TENDER VALUE 35.79 Lakhs
LAST DATE 23-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Electrical & Mechanical Services At Officers Da Flats/Bunglow At 6/8 Lancer Road-110054. (Sh - Renovation Works electrical installation Works).
Basic Detail
Tender No 56/2026-27/EMD M-351/EE(E)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 16 Oct 2026
Submission Date 23 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 35.79 Lakhs
Tender Fee Ref. Documents
EMD 71593
Exemption Not Available
Document List
56TenderNotice.pdf
BOQ_400493.xls
e0dab628-949a-4da5-9d1e-e724278211db.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

56TenderNotice.pdf

xls

BOQ_400493.xls

html

e0dab628-949a-4da5-9d1e-e724278211db.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender