Tender For Supplying, Installation, Testing & Commissioning Of Lift At Fob Near Shyamlal Collage, G.T. Road, Delhi. (Sh:- Electrical And Civil Work)
Tender Value
93.16 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
5 days left
EMD
1.86 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supplying, Installation, Testing & Commissioning Of Lift At Fob Near Shyamlal Collage, G.T. Road, Delhi. (Sh:- Electrical And Civil Work)
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head I (Electrical Work)Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-a) 13 passenger (884 Kg.)(i) Speed-1 MPS(ii) Floors-2 (G+1)(iii) Travel - 6 to 8 Meters (approx.)(iv) Stops & opening- 1 stops and 1 openings (All Floor are opening in same side)(v) Controller: A.C. variable voltage & variable frequency(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/ without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (.....................Cont............................. ) |
| 2 | (xi) Type of doors(a) Car: Power operated, center opening (minimum 900 mm door opening) horizontal sliding stainless steel scratch proof (b) Landing doors: stainless steel scratch proof.(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.(xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.(xvi) An appropriate technological support be provided (Through emergency messaging services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided(After installation of lift one year is defect liability period & no extra amount will be paid for any kind of repair/maintenance) |
| 3 | Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete asrequired:- a) 13 passenger (884 kg.)(i) Speed-1 MPS(ii) Floors-2 (G+1)(iii) Travel - 6 to 8 Meters (approx.)(iv) Stops & opening- 1 stops and 1 openings (Ground Floor & First Floor are opening opposite side)(v) Controller: A.C. variable voltage & variablefrequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/ without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.(xi) Type of doors(a) Car: Power operated, center opening (minimum 900 mm door opening) horizontal sliding stainless steel scratch proof. (....Cont.....) |
| 4 | (b) Landing doors: stainless steel scratch proof (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.(xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.(xiv) Closed loop Control System, protection against power fluctuation, self-diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D &P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.(xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided(After installation of lift one year is defect liability period & no extra amount will be paid for any kind of repair/maintenance) |
| 5 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 6 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 7 | Supplying and laying of following PVC insulated and PVC sheathed /XPLE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME METAL/PVC pipe as required. |
| 8 | 4 X 10 Sq. mm armounrd Aluminum conductor power cable |
| 9 | 3.5 X 50 Sq. mm armounrd Aluminum conductor power cable |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 11 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 12 | Fabrication, Supplying and installation of outdoor type cubical feeder pillar of size 1700mm x 1000mm x 300mm of M.S. sheet 2mm thick (14 SWG) duly compartmentalised having 4 strip busbars of 100amp capacity double door with two nos. godown locking arrangement for protection from rain, dust, duly fixed on M.S. angle iron frame work of size 40 mm X 40 mm X 6 mm (NS) 900 mm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand :4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminum thimbles, earthing with two nos. earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd. Supplying & Fixing of following accessories in the existing cubical panel board/feeder pillar including connection testing etc. as reqd.Indoor Panel (more than or equals to 1.3 Sqm.)Incoming:- a) 250Amp. 25 KA MCCB, TP with neutral link- 1 No.b) Spreder Link for MCCB -1setc) 110A FP power contactor -1 Nos.d) Digital Timer – 1 Nos.Metering:-a) Digital Ammeter, b) Digital Voltmeter, c) R. Y. B indication Lampd) ASS + VSS Selecter Switche) 6A SP MCB 10KA For Controllingf) CT 200/5A Class-1Outgoing:-a) 125Amp. 18 KA MCCB, TP with neutral link -3 Nos.b) Spreder Link for MCCB -3 set |
| 13 | Fabricating, Supplying and fixing wire mesh protection frame work made out of 40 x 40 mm x 6 mm thick angle and \\"T\\" strengthened with intermediate menberers of MS flat iron of size 32 x 6 mm x 5 mm thick welded at a distance of 30 cm horizontally and vertically and duly welded with wiremesh of size 75 mm x 25 mm made with 6 SWG wire mesh of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two nos. sliding bolts and one No. go down lock) having 0.5 mtr long legs of 40 mm x 40 mm x 6 mm thick angles iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) upto suitable depth painting with on coast of red oxide & two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd. |
| 14 | Supplying and fixing of 4.5 Kg capacity CO2 type Fire Extinguisher ISI marked Confirming to IS: 15683 complete with delivery horn, squeeze grip release valve, locking arrangement, operation manual, bracket with two screw and sleeve and suitable hanging arrangement complete in all respect etc. as reqd. |
| 15 | Supplying and Fixing of 6 Kg duly ISI Marked confirming to Is: 15683-2006 with IS 14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual, bracket with two screw and sleeve and suitable hanging arrangement complete in all respect |
| 16 | Sub Head II (Civil Work)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in in design mix shall be payable separately. In case the cement content design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level : |
| 18 | Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 19 | Concrete of M25 grade with minimum cement content of 300 kg /cum |
| 20 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 22 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 23 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates efc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 24 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: |
| 25 | Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 26 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 27 | On steel work |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 29 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 30 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (Payment under this item shall be made only after production of authorised MCD receipts and charges paid to MCD shall be reimbursed to the contractor separately on production of receipt of payment MCD charges). |
| 31 | Excavating holes upto 0.10 cum, including getting out the excavated soil, then returning the soil as deported in layers not exceeding 20 cm in depth, including consolidating and deposited layer by ramming watering etc., disposing of surplus excavated soil as directed with in a lead of 50 mm and lift upto 1.5 m. |
| 32 | All kind of soll |
| 33 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 34 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge. |
| 35 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge. |
| 36 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 37 | 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 38 | Modified Estimated Cost after using correction factor on DSR 2023 on account of GST @ 0.973 (vide No. 158/SE(TAS)/GST/2024/02-E dated 08.08.2024) on DSR itemAdd Cost Index @ 4.03% (On DSR Item) |
| 39 | Providing services of Hydraulic Mobile Pick and carry Crane Capacity up to 15.00 Tan for 8 Hours per day for removing Jersey Barriers from one place to another place, aligning the same, lifting the vehicles, heavy materials etc. including the cost of driver, supervisor all complete as per directions of Engineer-in-Charge. |
| 40 | Providing and fixing multi walled thermo clear glass look type, 6mm thick clear on required colour blue, brown or green etc. poly carbonate multi walled sheet with 50 micron UV(Ultra violet) coating both side required brand such as GE or polygal brand or approved by Engineer-in-charge in roofing of subway/foot over bridge in required shape of semi circular or plan or as per ap-proved design and drawing and direction of Engineer-in- charge. The multi walled poly carbonate sheet shall be fixed on tubular steel structure with 25 micron thick powder coated aluminium alcox section of size 60x 18x 2mm and weight not less than 0.462 Kg/m and weather proof Neoprin EPDM rubber gasket as both side of joints and top, so as to make the whole structure water tight as approved design/drawing. The Alcox aluminium section shall be fixed on joints and both nd of poly carbonate sheet to fix the sheet rigidly on steel frame structure. The weather proof neoprin and aluminium profile shall be fixed and sealed with silicon sealent to make the joints fully water proof. The open over hand end of poly carbonate sheet to be shield with powder coated aluminium channel of size 10x10x1.5m thick weight not less than 0.2 kg/m. Polycarbonate sheet and profile shall be fixed with self taping and self drilling 50mm long steel screws fixed not less than 150mm center to center. The rate shall be inclusive of cost of all material involved such as poly carbonate sheet, Alcox system aluminium profile, aluminium channel, EPDM gasket, self taping screws, nut bolts, silicon sealent or nay other material required for fixing the sheet but excluding the cost of steel structure which shall be paid separately. The cost also includes the rate of labour require for cutting bending and fixing of polycarbonate sheet aluminium profile, hosting in position etc. (...Cont....) |
| 41 | complete as per direction of Engineer-incharge. The rate shall also include the cost of all T&P and safety precautions required during execution of the work. All aluminium-um section shall have minimum powder coating of thickness not less than 25 micron. The work shall be completed in all respect as per design/ drawing and direction of Engineer-in-charge. |
| 42 | Note:- During the preparation of any running or final bill by the contractor it is essential that the contractor shall submit GST paid invoice, E-way bill and delivery challan for all items without these documents the bill will not be considered submitted in proper form & shall be returned back to the contractor by Junior Engineer (E). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender