Project Description

Tender for Sub-Station And Transmission Line (Package-C12)

BOQ

Name of Work:- Sub-Station and Transmission Line (PACKAGE-C12)
Sl. No. Item Description
1COMPOSITE PACKAGE-C12
2Sub-Station and Transmission Line (COMPOSITE PACKAGE-C12)
3Sadarghat
4Sat-Burdwan at Sadar
52.0 WBSETCL Assessed Quantities ELECTRICAL PART :
6145KV 31.5KA for 3sec Gas Insulated Switchgear i) 2000 A rated Double Bus Bar ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) suitable for EHV cable entry with single termination arrangement .vi) Standalone Local Control Cubicle (LCC) with all required accessories and Gas monitoring system. -The complete system shall be as per technical specification and requirement comprising of -
7Complete Line Bays with accommodation of 3 nos GIS Line VT each having 3 cores with provision for one numbers 1200 sq. mm EHV single entry per phase (2 nos core for Protection and 1 no core for metering and other parameters as per technical specification)
8Complete Transformer Bays with provision for one number 400 sq. mm EHV single entry per phase as per technical specification for HV side of 80 MVA 132/33 KV Transformer
9Bus coupler Bay
10Disconnector with earthing arrangement and gas tight barriers at One side of Main Bus I & II for future extension one side
113 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), one set for Main Bus-I & one set for Main Bus-II with disconnectors & earth switch & as per Tech Spec
12Other required equipment & accessories like Bus Earth Switch, gas barriers etc. to complete the GIS system.
13Portable UHF PD monitoring System - The analyser shall have 6 channel input with colour display unit and user friendly interface for detailed analysis.The system includes the required PD sensors to cover the total GIS portion, UHF cables, required software and other accessories to complete as per Technical Specification.
14Dew Point Meter as per Technical Specification
15DILO or equivalent make SF6 gas handling and filling cart with minimum 250Kg/ 300L storage capacity alongwith all accessories, adaptors etc for proper gas handling from and to GIS
1636 KV, 31.5 KA - 3sec, 2500A 2-main bus Indoor GIS type Switchgear Assembly with VCB interrupter and bus earthing arrangement with capacitive voltage indicator per phase in all feeders(line & transformer). Main bus , Circuit breaker and other equipment like disconnector etc shall be in SF6 environment with separate gas compartment. Provision of feeder earthing arrangement shall be present. The switchgear shall include Local Control system and other accessories complete as per technical specification and requirement comprising of -
17Outgoing Feeder Bay each having individual earthing arrangement (1250A and CT details as per Tech. Spec.)
18Transformer Bay ( Rating:- 2000 A and CT ratio of 2000-1600/1-1-1-1A) suitable for EHV cable entry with provision for triple termination arrangement.
19Station Service Transformer Bay ( Rating:- 1250A and CT details as per Tech. Spec.)
20Bus Coupler Bay (VCB Rating:- 2500 A and CT ratio of 2500/1-1-1Amp)
21Disconnector with earthing arrangement and gas tight barriers at One side of Main Bus I & II for future extension one side
22(i) 2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement./6 sets of single phase Bus PT ,3 nos for Main Bus I and 3 nos for Main Bus II as per Tecnical Specification(ii) Other required equipment & accessories like Line Earthing arrangement, Bus Earthing arrangement etc. to complete the system (iii) All interlocking relays ,switches ,lamps, push buttons etc are to be mounted on individual 33 KV GIS LCC Panels (iv) Low Gas Pressure stage -1 and stage 2 shall be monitored by individual 33 KV feeder panel BCU.
23Electric Overhead Travelling Crane (E.O.T.) - For 132 KV GIS Building5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher - complete with all accessories as per technical specification and requirement.
24XLPE Copper Cable as per Technical Specification
25132 KV 400 Sq. mm single core Cu cable with Alluminium corrugated sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 80 MVA, 132/33 KV Transformers - Single phase connection with single run cable for each phase - The actual length will be decided after joint inspection with site authority.
26132 KV 1200 Sq. mm Single Core Cu cable with Alluminium corrugated sheath (as per technical specification and as per requirement) for connection of 132 KV Line bay - Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing.
2733 KV 400 Sq.mm Three Core copper cable for line - Single phase connection with 1 run cable for each phase - The actual length will be decided after joint inspection with site authority.
2833 KV 630 Sq.mm Single Core copper cable for transformer - Single phase connection with 3 run cable for each phase - The actual length will be decided after joint inspection with site authority.
2933 KV 185 Sq.mm Three Core copper cable for two 315 KVA 33/.04 KV Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing.
30Outdoor End Termination Kit / cable sealing end and other required accessories for above XLPE cables as per requirement and specification :
31132 KV 400 Sq.mm single Core Copper Cable for HV side of 80 MVA Transformer (single phase connection with single run cable for each phase)
32132 KV 1200 Sq.mm single Core Copper Cable for Line feeder (single phase connection with single run cable for each phase) on tower cross arm
3333 KV 400 Sq.mm Three Core copper cable for line (Three phase connection with single run cable )
3433 KV 630 Sq.mm Single Core copper cable for LV side of 80 MVA Transformer (single phase connection with triple run cable for each phase)
3533 KV 185 Sq.mm size Three Core for two 315 KVA Auxiliary Transformer ( Three phase connection with single run cable )
36Indoor End Termination Kit for above XLPE cable : Dry Plug-In type GIS Indoor Termination kit with all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables.For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables.
37132 KV 400 Sq.mm single Core Copper Cable for HV side of 80 MVA Transformer (single phase connection with single run cable for each phase)
38132 KV 1200 Sq.mm single Core Copper Cable for Line feeder (single phase connection with single run cable for each phase )
3933 KV 400 Sq.mm Single Core copper cable for line (sigle run cable for each phase)
4033 KV 630 Sq.mm Single Core copper cable for LV side of 80 MVA Transformer (single phase connection with triple run cable for each phase)
4133 KV 185 Sq.mm size Three Core for two 315 KVA Auxiliary Transformer, ( Three phase connection with single run cable )
42Transformers
4380 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs including NIFPS, RTCC panel alongwith BCU and accessories in line with technical specification of Power Transformer. 132 KV bushing shall be of RIP/RIS type (Not to be Quoted. To be supplied by WBSETCL).
44STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Winding as per technical specification and requirement
45EARTHING TRANSFORMER: 33KV, 3 Ph ,fault current rating of 874 Amp for 30 sec as per Technical Specification and requirement
46Isolators : As per Technical specification
47132 KV, 1250A, 31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for HV side of 80 MVA Transformers, motor control - including solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch)
4833 KV, 2000 A, 31.5 KA for 3sec, CRDB, 3Ph Assembly without earth switch as per Tech. Specification - for LV side of 80 MVA 132/33 KV Transformer, (including Insulators )
4933 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly without Earth switch & with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(including insulator)
5033 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly isolator without Earth Swich ( for Earthing Transformer ) as per Tech. Specification(including insulator)
5133 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly isolator with Earth Swich ( for Line bay) as per Tech. Specification(including insulator)
52LIGHTNING ARRESTOR As per Technical specification
53120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 02 nos 80 MVA Transformers (Polymer type)
54120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 04 nos Line bay (Polymer type)
5542 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 80 MVA transformer ) ((Polymer type)
5642 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 33 KV feeer) ((Polymer type)
5742 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for SST) ((Polymer type)
58PROTECTION PANEL ( Rear open door ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Simplex type Protection Panels will be installed in Relay Room.)
59Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with group selection switch and all other accessories complete as per Tech Spec.
60Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel)
61Protection Panel with BCU (with 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec.
62132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec.
6333 KV simplex type control relay and protection panel with BCU as per technical specification-for Line Feeder and Station Transformer bay
6433 KV simplex type control relay and protection panel with BCU as per technical specification-for 132/33 KV KV Transformer
6533 KV simplex type control relay and protection panel with BCU (with 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) as per technical specification-for Bus Coupler bay
66Meter Panel without meter ( As per drawing uploaded)
67220 V Battery & Charger( As per technical Specification )
68VRLA Battery SET - 800AH 220 Volt (or higher if required as per battery capacity calculation)
69Battery Charger - 220 Volt. suitable for above Battery set in line with Technical Specification (Float Charger capacity - 80A and Float cum Boost Charger capacity - 120 A) - Charger shall be equipped with disconnecting arrangement for Load and Battery- Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch- Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.
70Communication Equipment (As per technical specification, BOQ and mentioned Annexure)
71Fibre Optic Terminal equipment ( with minimum five redundant directions with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at Burdwan, Satgachia, SLDC & Backup SLDC for data and voice communication and carrier aided protection).
72E1 Interface cards( Minimum 16 interfaces/card)
73Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card)
74Equipment Cabinets
75Main Distribution Frame (100 pairs)
76Pre-connectorised optical fibre patch cords as per requirement
77E-1 Port Interfacing Cable
78EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers
79Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement.
80Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control & office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge.
81Telephone cable (armoured) for all 2-wire telephones & other requirements as per specification and as per requirement
82STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charge's room etc.) with FO Panel
83Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing
8448V, 300AH VRLA type Battery
8548V, 60A Battery Charger
8648V DCDB as per technical specification
87Integration with existing Fiber Optic System at connecting Sub-Station on optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end.i) for voice & data communication ii) for carrier aided protection purpose-with supply of equipment and material (SFP,Patchcord, etc ) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken.
88SAS system (as per indicative Scheme diagram, Technical Specification and requirement) - Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit
89Rack mounted Main Server (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories (server is to be mounted at SERVER PANEL-1, for connection FO port to be considered).
90Rack mounted Standby Server (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories (server is to be mounted at SERVER PANEL-2, for connection FO port to be considered).
91Local HMI (client Terminal) with 32\\" Monitor (LED)
92Remote HMI PC with monitor (32\\"LED) and necessary software for remote control and monitoring via local substation Gateway, shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect.
93Main Gateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol.
94Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol
95Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) with Monitors (32\\" size- LED)
961 no PC with monitor (32\\" size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays .
97Rack mounted complete GPS unit, to be mounted in server panels .
98Laser Colour Printer (suitable for at least A3 size)
99Dot Matrix Printer
100PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade.
101SAS application software with required license (suitable for 6000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully.
102Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on 220V station battery , to feed SERVER, GATEWAY, HMI, Engineers Work Station, Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc.
103Cabling System - Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Patch cords, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement.
104LIU having minimum 12 ports.
105Red Box having minimum 4 RJ45 & 2 FO ports.
106Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB, replica of annunciator with buzzer & reset arrangement, & fire fighting annunciator etc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel.
107Premium quality Integrated Control console desk with chairs and other furnitures for HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators
108Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End.
109Router cum firewall shall be provided at local end for remote data transmission .
110Network panel and other material / equipment / accessories required for successful completion of the job .
111Automated notification in the form of SMS -i) SMS is required to be sent to 5 (five) mobile numbers at a time.ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained.iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable.iv) All required hardwares and softwares to establish the system is under scope of the bidder.v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder. SIM will be provided by WBSETCL.vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL.
112Vendor Assessed Quantities:
113AC DISTRIBUTION BOARD (comprising of Main ACDB, Sub-ACDB and MLDB) complete as per technical specification and as per requirement. In addition to incomers from 2 nos Station Transformer, and suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered
114DC DISTRIBUTION BOARD complete as per technical specification and as per requirement
115CONTROL CABLE (1.1 KV GRADE)The actual quantity shall be finalised depending on the approved drawing and as per requiretrsent
11619 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
11714 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
11810 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
1197 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
1205 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
1213 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
1225 core, PVC, Armoured 4 Sq. mm Copper as per Technical Specification. (For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core).
123POWER CABLE - Multi Core, PVC, Artrsoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification and as per requiretrsent and as per approved drawing (All cables shall be of Copper only.) (with colur coded)
1241 C X 185 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1251C X 50 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1261C X 25 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1273C X 2.5 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1284C X 25 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1294C X 16 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1304C X 10 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1314C X 4 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
1324C X 2.5 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
133ACSR CONDUCTOR & Earth/Shield wire with accessories as per Technical Specification and as per requiretrsent
134ACSR Moose
135ACSR Panther
136Earth /Shield wire for LM down comer only
137ALUMINIUM TUBULAR PIPE (Schedule 40) as per Technical Specification and as per requiretrsent
1382.5\\" IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement
1391.5\\" IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement
140CLAMPS,CONNECTORS, BUNDLE SPACER, Hardware fittings & accessories including equipment connectors(SUITABLE FOR SCH. 40) and as per approved ACSR conductor as per Technical Specification and as per requirement
141For 132 KV system
142For 33 KV system
143Solid Core POST INSULATOR with accessories as per Technical Specification and requiretrsent
144For 132 KV BPI as per Technical Specification and as per requiretrsent
145For 33 KV BPI as per Technical Specification and as per requiretrsent
146ILLUMINATION SYSTEM
147ILLUMINATION SYSTEM COMPLETE for outdoor switchyards per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification). Fixtures must be LM mounted.
148ILLUMINATION SYSTEM COMPLETE for Gates, Road, Utility area and other outdoor portion of SubStation except switchyard as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification)
149ILLUMINATION SYSTEM COMPLETE integrated GIS cum Control Building as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type.
150ILLUMINATION SYSTEM COMPLETE for all other utility buildings like - Pump House, Security Goomty / Barrack, Store etc. as applicable, as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type.
151Dehumidifier with suitable capacity & size for 33 KV Switchgear Room
152AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.)
153Relay and Control Room and SAS Room - Ductable Air Conditioning System is to be considered. - All machines must be of same make. Considering continuous operation, machines must be of Industrial grade and refrigerent must be of R32 or better environmental standards .as per specification
1545 star rated Split type Non-Ductable AC for Battery & Charger room, In-Charge Room,Conference room,DB Room,Communication Room.All machines must be of same make . Considering continuous operation except In-Charge Room & Conference room , machines must be of 5 star rated split and refrigerent must be of R32 or better environmental standards as per specification
155FIRE FIGHTING & FIRE PROTECTION SYSTEM
156Fire hydrant system in ring formation along the periphery of switchyard covering entire portion , GIS building, Control Building etc as required.
157Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area and other building and near each Power Transformer as per Technical spec . and as per requirement.
158Fire Alarm System (Concealed cabling is preferred ) -i) Smoke & heat detection system covering all the rooms of Control room building ii) adequate beam detector with redundancy for GIS room - as per technical specification & requirement
159CCTV Survelliance system (as per Tech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design .
160Fixed Bullet camera (short range) with all accessories -as per technical specification.
161Fixed Bullet camera (long range) with all accessories -as per technical specification.
162Fixed Dome camera with all accessories-as per technical specification.
163PTZ camera with all accessories-as per technical specification.
164VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification.
165Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification.
16640\\" 4K Display, 24 x 7 operation; as per technical specifications
1672 KVA online UPS with 30 minute backup-as per technical specification.
16824 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications
169Required number of 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications
170Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification.
171All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification.
172Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance system as per site requirement.
173NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS.
174One additional viewing units at In-Charge Room with all required hardware and software
175SUBSTATION EARTHING SYSTEtrs : As per Technical specification
176MS rod of size 32 mm dia or higher for main earthmat grid, corner mesh, auxilary mat and double run periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, auxilary mat, double run periphrey & corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m or actual measured value whichever is higher.
17732mm Dia MS rod for riser below the ground
178GS flat of size 50 x 10 mm for riser above ground, cable trench & other areas.
179Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specification and approved design/layout including earth pit.
180Earthing for GIS enclosure and GIS building as per manufacturers recommendation including supply of Earthing materials including civil work
181Earth Strip and other accessories including lugs for link box etcwherever required for Earthing of all XLPE Cable completei as per technical requirement / as per approved drawings.
1823 ph Earth Link Box with SVL as per technical requirement / as per approved drawings.
1833 ph Earth Link Box with out SVL as per technical requirement / as per approved drawings.
1841 ph Earth Link Box with SVL as per technical requirement / as per approved drawings.
1851 ph Earth Link Box with out SVL as per technical requirement / as per approved drawings.
1866.6 KV/3.8 KV Copper bonding cable with suitable diameter as per Technical Specification
1871.1 KV 240 sqmm Copper earth continuity cable as per approved drawing and Technical specification
188GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification)
1895 kWp Solar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement.
190i) High quality inverter from reputed brand (as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant.ii) All other required accessories - Data logger with CPU, LCD monitor, UPS, Metering, Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyranometer with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant
191Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract.
192MISCELLANEOUS ITEMS - As per Technical specification i) Glow signboard for name of the substation - minimum size 50 sq ft, ii) schematic SLD on glow signboardiii) Danger plate, phase plate, bay nameplate etciv) Cable route marking, area marking, direction sign etc as per instruction of Site-In-Charge.v) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required.vi) Shock treatment chart in local and English language duly mounted on wooden frame with glass as requiredvii) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18 viii) WBSETCL LOGO & Sub-Station Name at main gate of Sub-Station entry with good quality durable materials ix) Angle, Channel and other hardwares for installation of panels, DBs etc., ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc.
193Bay marshalling kiosk, etc including fitting & fixing as per requirement & as per Technical specification
194Bay Marshalling kiosk,
195Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc.
196Supply of items Trefoil clamp suitable for approved XLPE cable, fabrication marker, tags, Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing
197HDPE Pipes ( as per actual requiretrsent) as per technical specification
198300 mm Dia
199200 mm Dia
200150 mm Dia
201Cable Tray (Ladder type & perforated type etc ) as per requiretrsent for indoor/outdoor cable trench as per tender drawing, techincal spec & as per requiretrsent
202Cable Tray (Ladder type ), 3 mm thick 600 mm wide
203Cable Tray (Ladder type ), 3 mm thick 450 mm wide
204Cable Tray (Ladder type ), 3 mm thick 300 mm wide
205Cable Tray (Perforated type ),3 mm thick 300 mm wide
206Cable Tray (Perforated type ),3 mm thick 150 mm wide
207Industrial type Exhaust Fans and mechanised louvers of required quantity for 132 KV & 33 KV GIS Hall & cable speader room as per requirement & as per Tech Spec
208Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control building, FFPH, as per relevant IEC.
209One storage type RO + UV + UF water purifier for office building
210Passenger Elevator (6 person capacity, minimum 1mtr/sec sped) - For GIS & Control building complete in all respect as per technical specification and as per requirement.
211DG set 100KVA with all accessories as per Technical specification
212Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materials will be as per scheme of this project )
213Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection)
214Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection)
215Transformer differential Relay(same as approved for 132 KV Transformer bay)
216BCU (same as approved for 132KV Bus Coupler bay )
217BCU (same as approved for 33KV Bus Coupler bay )
218BCU (same as approved for auxilliary system)
219PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml)
220Over Current & Earth fault Relay
221Bus Bar Differential Relay
222high Speed Trip Relay
223VT selection Relay
224Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project.
225132KV GIS Circuit Breaker complete mechanism
226132KV GIS Disconnector complete mechanism
227132KV GIS High speed earth switch complete mechanism
22833KV CT - same as supplied for Line bay
22933KV CT - same as supplied for 80 MVA Transformer bay
230Safety Equipment
231Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per Tchnical Specification
232First aid box complete with all items (as per Annexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room
233Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 400 KV system, CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 and as per tech spec
234Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50 deg C as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) as per tech spec
235Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.)
236Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.2 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071
237Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298
238Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable for 40 KV as per IS - 4770 and as per tech. spec.
239Electric Arc Protection Suit - FR suit compatible to wear with hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9
240Insulating mat - High density insulating mats as per IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room)
241Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft
242Safety Torch / Search Light-(reputed brand like Philips or eqivalent)Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 35 watt LED, Power source - 12 volt, 10,000 mAH Li-ion battery, Extra jack to be provided for direct lightning by 12 volt DC, Continuous run - 4 hr. High beam Long Range Rechargeable Hand Held Search light
243Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long
244Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC.
245Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken.
246Civil Part: Supply, fabrication, galvanisaton of various switchyard & equipment structures, LM- Lattice type/ Hi mast ( 30/35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure complete as per approved electrical layout drawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts)
247Switchyard Structures including Nuts & Bolts (all are Galvanised)
248MS Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanised upto the threaded length from top including nuts & washers)
249Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) and requirement complete.
2502.0 WBSETCL Assessed Quantities ELECTRICAL PART :
251145KV 31.5KA for 3sec Gas Insulated Switchgear i) 2000 A rated Double Bus Bar ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) suitable for EHV cable entry with single termination arrangement .vi) Standalone Local Control Cubicle (LCC) with all required accessories and Gas monitoring system. -The complete system shall be as per technical specification and requirement comprising of -
252Complete Line Bays with accommodation of 3 nos GIS Line VT each having 3 cores with provision for one numbers 1200 sq. mm EHV single entry per phase (2 nos core for Protection and 1 no core for metering and other parameters as per technical specification)
253Complete Transformer Bays with provision for one number 400 sq. mm EHV single entry per phase as per technical specification for HV side of 80 MVA 132/33 KV Transformer
254Bus coupler Bay
255Disconnector with earthing arrangement and gas tight barriers at One side of Main Bus I & II for future extension one side
2563 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), one set for Main Bus-I & one set for Main Bus-II with disconnectors & earth switch. As per Tech Spec
257Other required equipment & accessories like Bus Earth Switch, gas barriers etc. to complete the GIS system.
258Portable UHF PD monitoring System - The analyser shall have 6 channel input with colour display unit and user friendly interface for detailed analysis.The system includes the required PD sensors to cover the total GIS portion, UHF cables, required software and other accessories to complete as per Technical Specification.
25936 KV, 31.5 KA - 3sec, 2500A 2-main bus Indoor GIS type Switchgear Assembly with VCB interrupter and bus earthing arrangement with capacitive voltage indicator per phase in all feeders(line & transformer). Main bus , Circuit breaker and other equipment like disconnector etc shall be in SF6 environment with separate gas compartment. Provision of feeder earthing arrangement shall be present. The switchgear shall include Local Control system and other accessories complete as per technical specification and requirement comprising of -
260Outgoing Feeder Bay each having individual earthing arrangement (1250A and CT details as per Tech. Spec.)
261Transformer Bay ( Rating:- 2000 A and CT ratio of 2000-1600/1-1-1-1A) suitable for EHV cable entry with provision for triple termination arrangement.
262Station Service Transformer Bay (VCB Rating:- 1250A and CT details as per Tech. Spec.)
263Station Service Transformer Bay ( Rating:- 1250A and CT details as per Tech. Spec.)
264Disconnector with earthing arrangement and gas tight barriers at One side of Main Bus I & II for future extension one side
265(i) 2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement./6 sets of single phase Bus PT ,3 nos for Main Bus I and 3 nos for Main Bus II as per Tecnical Specification(ii) Other required equipment & accessories like Line Earthing arrangement, Bus Earthing arrangement etc. to complete the system (iii) All interlocking relays ,switches ,lamps, push buttons etc are to be mounted on individual 33 KV GIS LCC Panels (iv) Low Gas Pressure stage -1 and stage 2 shall be monitored by individual 33 KV feeder panel BCU.
266Electric Overhead Travelling Crane (E.O.T.) - For 132 KV GIS Building5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher - complete with all accessories as per technical specification and requirement.
267XLPE Copper Cable as per Technical Specification
268132 KV 400 Sq. mm single core Cu cable with Alluminium corrugated sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 80 MVA, 132/33 KV Transformers - Single phase connection with single run cable for each phase - The actual length will be decided after joint inspection with site authority.
269132 KV 1200 Sq. mm Single Core Cu cable with Alluminium corrugated sheath (as per technical specification and as per requirement) for connection of 132 KV Line bay - Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing.
27033 KV 400 Sq.mm Three Core copper cable for line - Single phase connection with 1 run cable for each phase - The actual length will be decided after joint inspection with site authority.
27133 KV 630 Sq.mm Single Core copper cable for transformer - Single phase connection with 3 run cable for each phase - The actual length will be decided after joint inspection with site authority.
27233 KV 185 Sq.mm Three Core copper cable for two 315 KVA 33/.04 KV Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing.
273Outdoor End Termination Kit / cable sealing end and other required accessories for above XLPE cables as per requirement and specification :
274132 KV 400 Sq.mm single Core Copper Cable for HV side of 80 MVA Transformer (single phase connection with single run cable for each phase )
275132 KV 1200 Sq.mm single Core Copper Cable for Line feeder (single phase connection with single run cable for each phase ) on tower cross arm
27633 KV 400 Sq.mm Three Core copper cable for line (Three phase connection with single run cable )
27733 KV 630 Sq.mm Single Core copper cable for LV side of 80 MVA Transformer (single phase connection with triple run cable for each phase)
27833 KV 185 Sq.mm size Three Core for two 315 KVA Auxiliary Transformer, ( Three phase connection with single run cable )
279Indoor End Termination Kit for above XLPE cable : Dry Plug-In type GIS Indoor Termination kit with all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables.For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables.
280132 KV 400 Sq.mm single Core Copper Cable for HV side of 80 MVA Transformer (single phase connection with single run cable for each phase )
281132 KV 1200 Sq.mm single Core Copper Cable for Line feeder (single phase connection with single run cable for each phase )
28233 KV 400 Sq.mm Single Core copper cable for line (sigle run cable for each phase)
28333 KV 630 Sq.mm Single Core copper cable for LV side of 80 MVA Transformer (single phase connection with triple run cable for each phase)
28433 KV 185 Sq.mm size Three Core for two 315 KVA Auxiliary Transformer, ( Three phase connection with single run cable )
285Transformers
28680 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs including RTCC panel alongwith BCU and accessories in line with technical specification of Power Transformer. 132 KV bushing shall be of RIP/RIS type.
287Nitrogen Injection type Fire Prevention & Exinguisher system including reservoir tank & all required acessories for 80 MVA 132/33 KV Transformer
288STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Winding as per technical specification and requirement
289EARTHING TRANSFORMER: 33KV, 3 Ph ,fault current rating of 874 Amp for 30 sec as per Technical Specification and requirement
290Isolators : As per Technical specification
291132 KV, 1250A, 31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for HV side of 80 MVA Transformers, motor control - including solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch)
29233 KV, 2000 A, 31.5 KA for 3sec, CRDB, 3Ph Assembly without earth switch as per Tech. Specification - for LV side of 80 MVA 132/33 KV Transformer, (including Insulators )
29333 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly without Earth switch & with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(including insulator)
29433 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly isolator without Earth Swich ( for Earthing Transformer ) as per Tech. Specification(including insulator)
29533 KV, 1250A, 31.5 KA for 3sec, CRDB, 3Ph Assembly isolator with Earth Swich ( for Line bay) as per Tech. Specification(including insulator)
296LIGHTNING ARRESTOR As per Technical specification
297120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 02 nos 80 MVA Transformers (Polymer type)
298120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 04 nos Line bay (Polymer type)
29942 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 80 MVA transformer ) ((Polymer type)
30042 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 33 KV feeer) ((Polymer type)
30142 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for SST) ((Polymer type)
302PROTECTION PANEL ( Rear open door ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Simplex type Protection Panels will be installed in Relay Room.)
303Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with group selection switch and all other accessories complete as per Tech Spec.
304Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel)
305Protection Panel with BCU (with 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec.
306132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec.
30733 KV simplex type control relay and protection panel with BCU as per technical specification-for Line Feeder and Station Transformer bay
30833 KV simplex type control relay and protection panel with BCU as per technical specification-for 132/33 KV KV Transformer
30933 KV simplex type control relay and protection panel with BCU (with 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) as per technical specification-for Bus Coupler bay
310Meter Panel without meter ( As per drawing uploaded)
311220 V Battery & Charger( As per technical Specification )
312VRLA Battery SET - 800AH 220 Volt (or higher if required as per battery capacity calculation)
313Battery Charger - 220 Volt. suitable for above Battery set in line with Technical Specification (Float Charger capacity - 80A and Float cum Boost Charger capacity - 120 A) - Charger shall be equipped with disconnecting arrangement for Load and Battery- Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch- Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.
314Communication Equipment (As per technical specification, BOQ and mentioned Annexure)
315Erection of Fiber Optic Communication Equipment complete as per requirement, technical specification, mentioned Annexure and supply BOQ Item
316Demonstration and hands on training at factory for group of 2 person for SDH and DPC -The complete system configuration, operation, control, monitoring, testing, maintenance along with integration with NMS as per requirement for at least 3 working days.The complete literature both hard binded and in soft form are to be provided.The entire cost of journey, accommodation, food and other incidental expenses for the training to be borne by the bidder.
317SAS system (as per indicative Scheme diagram, Technical Specification and requirement) - Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit
318Establishment of complete SAS system with all functionality as detailed in supply BOQ, specification and as per requirement, including integration of IEDs installed at WBSETCL supplied RTCC and other panels etc.
319Integration of Sub-Station data at SLDC and back up SLDC (including data base creation) as per requirement of technical specification by directly communicating with agency engaged for AMC of SCADA at SLDC and Back up SLDC End.
320Sharing all required information and files to the concerned vendor, configuration of necessary ports etc. for Integration of Sub-Station data at Central Command and Control Centre
321Demonstration at hands on training at factory & on-site training for group of 5 person -The complete SAS system architecture, configuration, operation, control, monitoring , maintenance & trouble shooting at card level of the same as per requirement (at least 5 working days at factory / workshop excluding journey days and 2 days at site on the actual SAS system during commissioning). The complete literature both hard binded and in soft form are to be provided.Two sets of Demo version of SCADA software to be handed over at Communication/Testing Dept .The entire cost of journey, accommodation, food and other incidental expenses for the training to be borne by the bidder.
322Automated notification in the form of SMS -i) SMS is required to be sent to 5 (five) mobile numbers at a time.ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained.iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable.iv) All required hardwares and softwares to establish the system is under scope of the bidder.v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder. SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL.
323Vendor Assessed Quantities:
324AC DISTRIBUTION BOARD (comprising of Main ACDB, Sub-ACDB and MLDB) complete as per technical specification and as per requirement. In addition to incomers from 2 nos Station Transformer, and suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered
325DC DISTRIBUTION BOARD complete as per technical specification and as per requirement
326CONTROL CABLE (1.1 KV GRADE)The actual quantity shall be finalised depending on the approved drawing and as per requirement
32719 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
32814 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
32910 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
3307 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
3315 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
3323 core, PVC, Armoured 2.5 Sq. mm Copper as per Technical Specification.
3335 core, PVC, Armoured 4 Sq. mm Copper as per Technical Specification. (For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core).
334POWER CABLE - Multi Core, PVC, Artrsoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification and as per requiretrsent and as per approved drawing (All cables shall be of Copper only.) (with colur coded)
3351 C X 185 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3361C X 50 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3371C X 25 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3383C X 2.5 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3394C X 25 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3404C X 16 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3414C X 10 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3424C X 4 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
3434C X 2.5 sq. mm PVC, Armoured, 1.1 KV POWER CABLE (Copper) as per Technical Specification
344ACSR CONDUCTOR & Earth/Shield wire with accessories as per Technical Specification and as per requiretrsent
345ACSR Moose
346ACSR Panther
347Earth /Shield wire for LM down comer only
348ALUMINIUM TUBULAR PIPE (Schedule 40) as per Technical Specification and as per requirement
3492.5\\" IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement
3501.5\\" IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement
351CLAMPS,CONNECTORS, BUNDLE SPACER, Hardware fittings & accessories including equipment connectors(SUITABLE FOR SCH. 40) and as per approved ACSR conductor as per Technical Specification and as per requirement
352For 132 KV system
353For 33 KV system
354Solid Core POST INSULATOR with accessories as per Technical Specification and requiretrsent
355For 132 KV BPI as per Technical Specification and as per requiretrsent
356For 33 KV BPI as per Technical Specification and as per requiretrsent
357ILLUMINATION SYSTEM
358ILLUMINATION SYSTEM COMPLETE for outdoor switchyards per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification). Fixtures must be LM mounted.
359ILLUMINATION SYSTEM COMPLETE for Gates, Road, Utility area and other outdoor portion of SubStation except switchyard as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification)
360ILLUMINATION SYSTEM COMPLETE integrated GIS cum Control Building as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type.
361ILLUMINATION SYSTEM COMPLETE for all other utility buildings like - Pump House, Security Goomty / Barrack, Store etc. as applicable, as per technical specification and requirement. All luminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type.
362Dehumidifier with suitable capacity & size for 33 KV Switchgear Room
363AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.)
364Relay and Control Room and SAS Room - Ductable Air Conditioning System is to be considered. - All machines must be of same make. Considering continuous operation ,machines must be of Industrial grade and refrigerent must be of R32 or better environmental standards .as per specification
3655 star rated Split type Non-Ductable AC for Battery & Charger room, In-Charge Room,Conference room,DB Room,Communication Room.All machines must be of same make . Considering continuous operation except In-Charge Room & Conference room , machines must be of 5 star rated split and refrigerent must be of R32 or better environmental standards as per specification
366FIRE FIGHTING & FIRE PROTECTION SYSTEM -
367Fire hydrant system in ring formation along the periphery of switchyard covering entire portion , GIS building, Control Building etc as required.
368Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area and other building and near each Power Transformer as per Technical spec . and as per requirement.
369Fire Alarm System (Concealed cabling is preferred ) -i) Smoke & heat detection system covering all the rooms of Control room building ii) adequate beam detector with redundancy for GIS room - as per technical specification & requirement
370CCTV Survelliance system (as per Tech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design .
371Fixed Bullet camera (short range) with all accessories -as per technical specification.
372Fixed Bullet camera (long range) with all accessories -as per technical specification.
373Fixed Dome camera with all accessories-as per technical specification.
374PTZ camera with all accessories-as per technical specification.
375VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification.
376Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification.
37740\\" 4K Display, 24 x 7 operation; as per technical specifications
3782 KVA online UPS with 30 minute backup-as per technical specification.
37924 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications
380Required number of 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications
381Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification.
382All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification.
383Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance system as per site requirement.
384NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS.
385One additional viewing units at In-Charge Room with all required hardware and software
386SUBSTATION EARTHING SYSTEM : As per Technical specification
387MS rod of size 32 mm dia or higher for main earthmat grid, corner mesh, auxilary mat and double run periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, auxilary mat, double run periphrey & corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m or actual measured value whichever is higher.
38832mm Dia MS rod for riser below the ground
389GS flat of size 50 x 10 mm for riser above ground, cable trench & other areas.
390Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specification and approved design/layout including earth pit.
391Earthing for GIS enclosure and GIS building as per manufacturers recommendation including supply of Earthing materials.including civil work
392Earth Strip and other accessories including lugs for link box etcwherever required for Earthing of all XLPE Cable completei as per technical requirement / as per approved drawings.
3933 ph Earth Link Box with SVL as per technical requirement / as per approved drawings.
3943 ph Earth Link Box with out SVL as per technical requirement / as per approved drawings.
3951 ph Earth Link Box with SVL as per technical requirement / as per approved drawings.
3961 ph Earth Link Box with out SVL as per technical requirement / as per approved drawings.
3976.6 KV/3.8 KV Copper bonding cable with suitable diameter as per Technical Specification
3981.1 KV 240 sqmm Copper earth continuity cable as per approved drawing and Technical specification
399GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification)
4005 kWp Solar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement.
401i) High quality inverter from reputed brand (as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant.ii) All other required accessories - Data logger with CPU, LCD monitor, UPS, Metering, Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyranometer with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant
402Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract.
403MISCELLANEOUS ITEMS - As per Technical specification i) Glow signboard for name of the substation - minimum size 50 sq ft, ii) schematic SLD on glow signboardiii) Danger plate, phase plate, bay nameplate etciv) Cable route marking, area marking, direction sign etc as per instruction of Site-In-Charge.v) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required.vi) Shock treatment chart in local and English language duly mounted on wooden frame with glass as requiredvii) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18 viii) WBSETCL LOGO & Sub-Station Name at main gate of Sub-Station entry with good quality durable materials ix) Angle, Channel and other hardwares for installation of panels, DBs etc., ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc.
404Bay marshalling kiosk, etc including fitting & fixing as per requirement & as per Technical specification
405Bay Marshalling kiosk,
406Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc.
407Supply of items Trefoil clamp suitable for approved XLPE cable, fabrication marker, tags, Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing
408HDPE Pipes ( as per actual requiretrsent) as per technical specification
409300 mm Dia
410200 mm Dia
411150 mm Dia
412Cable Tray (Ladder type & perforated type etc ) as per requiretrsent for indoor/outdoor cable trench as per tender drawing, techincal spec & as per requiretrsent
413Cable Tray (Ladder type ), 3 mm thick 600 mm wide
414Cable Tray (Ladder type ), 3 mm thick 450 mm wide
415Cable Tray (Ladder type ), 3 mm thick 300 mm wide
416Cable Tray (Perforated type ),3 mm thick 300 mm wide
417Cable Tray (Perforated type ),3 mm thick 150 mm wide
418Industrial type Exhaust Fans and mechanised louvers of required quantity for 132 KV & 33 KV GIS Hall & cable speader room as per requirement & as per Tech Spec
419Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control building, FFPH, as per relevant IEC.
420One storage type RO + UV + UF water purifier for office building
421Passenger Elevator (6 person capacity) - For GIS & Control building complete in all respect as per technical specification and as per requirement.
422DG set 100KVA with all accessories as per Technical specification
423Civil (Structural) Part:
424Erection of various switchyard & equipment structures, Hi-mast/LM- Lattice type ( 30/35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure complete as per approved electrical layout drawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) Civil Part: SADARGHAT 132KV SUBSTATION
425Survey work (topography & contour) & setting out of layout as per bid drawing so as to match the land ulitilisation plan drawing as per technical specification, requirement complete.
426Soil investigation & Electrical resisitivity test as per bid drawing so as to match the land ulitilisation plan drawing as per technical specification, requirement complete.
427Bore hole upto required depth including geo-technical investigation report in line with civil technical specification & requirement complete.
428Electrical resisitivity test including report in line with technical specification & requirement complete.
429Land development work upto the required formation ground level (F.G.L.) within the boundary area including necessary filling in line with Technical Specification, requirement complete and as per direction of EIC. FGL of the WBSEDCL Switchyard shall be considered as FGL of proposed Sub-station
430Design and construction of RCC earth retaining guard wall of varying filling height as per requirement at site, as per approved drawing, specification and requirement complete.
431Concreting with Reinforced Cement Concrete M-20 grade including supply of all materials, labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement (for main & distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) as per approved drawing, Technical Specification & requirement complete and as per direction of EIC.Necessary weep holes shall be provided as per approved drawing, technical specification and direction of EIC.All sorts of dewatering & shoring are included and will be done as per site requirement in consultation with EIC.
432Placing of 75mm dia PVC pipe along with graded filter (200x200x300mm) on each weep holes for drainage of water including supply of all materials, labour as required as per Technical Specification, approved drawing and requirement complete.
433Dismantling of Existing Structures
434Dismantling of super and sub structures of existing boundary wall (as per requirement) including removal of spoils as per instruction of the EIC. Serviceable materials, if any, are to be handed over to WBSETCL as per direction of EIC.
435Dismantling of existing steel/concrete structures alongwith foundations except boundary wall (as per requirement) including removal of spoils as per instruction of the EIC. Serviceable materials, if any, are to be handed over to WBSETCL as per direction of EIC. N.B.: Lead distance of dismantled debris/non serviceable materials shall be finalized in consultation with EIC and as suit to site.
436Planning, design & construction of Integrated building, having decent architectural view, complete including antitermite treatment as per Technical Specification, approved drawing & requirement complete. Provision shall be kept for installation of GIS equipments and cable entry in GIS hall. (Continuous cut outs to be provided for cable entry in floor slabs for GIS hall considering future provision including provision for entry of control cable at respective locations in GIS floor. SUPER-STRUCTURE (above FGL)
437Concreting in superstructure (excluding indoor cable trench & plinth beam) with Reinforced Cement Concrete M-25 grade including supply of all materials, labour and tools & tackles as required Including shuttering, scaffolding/ staging and Supply & laying of Reinforcement (for main & distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) as per approved drawing, Technical Specification & requirement complete and as per direction of EIC.
4381st Class Clay Brick Work in all floors including supply of all materials, scaffolding/staging & labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC.
439250thk. Brick wall with cement mortar (1:4) including supply of all materials, scaffolding/staging & labour complete
440125thk. Brick wall with cement mortar (1:4) with H.B. netting) including supply of all materials, scaffolding/staging & labour complete
44175thk. Brick wall with cement mortar (1:4) with H.B. netting) including supply of all materials, scaffolding/staging & labour complete
442Plaster (to wall, floor, ceiling etc.) with sand and cement mortar in all floors including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging, materials, labour & cost of chipping over concrete surface complete as per Technical Specification and approved drawing & requirement complete and as per direction of the EIC.
443External walls in cement sand ratio (1:4) including supply of all materials, scaffolding/staging & labour complete
444Internal walls in cement sand ratio (1:4) including supply of all materials, scaffolding/staging & labour complete
445Ceiling in cement sand ratio (1:3) including supply of all materials, scaffolding/staging & labour complete
446Applying white cement based wall putty on new surface after necessary cleaning, smoothening in all floors including supply of all materials, scaffolding/ staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC.
447Applying interior grade acrylic primer (one coat) on plastered surface to receive acrylic emulsion paint in all floors after scraping & prepearing the surface throughly including supply of all materials, scaffolding/ staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC
448Applying interior grade acrylic emulsion paint (two coats) of over primered surface in all floors including supply of all materials, scaffolding/ staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC
449Applying exterior grade acrylic emulsion paint (two coats) over a layer of suitable primer (1 coat) in all outside walls after necessary cleaning, smoothening including supply of all materials, scaffolding/ staging and labour complete as per Technical Specification, approved drawing & requirement complete and as per direction of the EIC
450Fitting and fixing collapsible Gate including supply of all materials, staging and labour complete in all floors as per Technical Specification and approved drawing, requirement complete and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.
451Fitting and fixing of MS Grill (18Kg/Sq.m.) including supply of all materials staging and labour complete in all floors as per Technical Specification and approved drawing, requirement complete and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.
452Fitting and fixing of mechanized Rolling shutter (with head box) including supply of all materials, staging and labour complete as per Technical Specification and approved drawing, requirement complete and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.Payment will be made based on the rolling shutter opening area only.
453Roof Treatment works in building roof including supply of all materials, staging (as required) and labour complete as per Technical Specification, approved drawing and as per direction of the EIC.
454Fitting and fixing false ceiling with relevant grid system and false ceiling boards in line with Technical Specification and approved drawings, including supply of all materials of approved make, staging and labour & requirement complete & as per direction of the EIC.
455Artificial stone flooring & skirting with necessary underlay complete including supply of all materials and labour complete as per Technical Specification, approved drawing and as per direction of the EIC.
45650MM thk IPS with Metallic hardener flooring and skirting with necessary underlay complete including supply of all materials and labour complete as per Technical Specification,approved drawing and as per direction of the EIC.
457Laying of epoxy paint (in line with the manufacturer specification) of approved colour over the metallic hardener flooring as per direction of the EIC including supply of all materials and labour & requirement complete. However application of the paint shall be done at site by the authorized applicator of the paint manufacturer.
458Laying of Vitrified tiles (premium quality) of approved brand in floor, stair & skirting with necessary underlay complete including supply of all materials and labour complete as per Technical Specification, approved drawing and as per direction of the EIC.
459Laying of chequered tiles of approved brand in Plinth protection with necessary underlay complete including supply of all materials and labour complete as per Technical Specification, approved drawing and as per direction of the EIC.
460Laying of Kota Stone in floor, stair & skirting with necessary underlay completeincluding supply of all materials and labour complete as per Technical Specification, approved drawing and as per direction of the EIC.
461Laying of Coloured Ceramic Tiles (Anti Skid) in floor with necessary underlay complete including supply of all materials and labour complete as per Technical Specification,approved drawing and as per direction of the EIC.
462Laying of Coloured Ceramic Tiles in wall with necessary underlay complete including supply of all materials and labour complete as per Technical Specification, approved drawing & requirement complete.
463Fitting and fixing of all type of Doors(including glass as required), Windows (including glass as required), fixed glass, louver, ventilator etc. in all floors including suitable priming and painting for GIS Building including supply of all materials, scaffolding/staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC, excluding rolling shutter, collapsible gate and MS grill on windows.
464Fitting and fixing of all type of Single & double leaf Aluminium Doors (including glass fixing at top and side as required) in all floors.including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC,
465Fitting and fixing of all type of Single leaf Flush Doors in all floors including suitable priming and painting including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC.
466Fitting and fixing of all type of Single leaf PVC Doors (for Toilet block) in all floors including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC
467Fitting and fixing of Single leaf TATA PRAVESH Doors in all floors including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC
468Fitting and fixing of all type of openable Windows (including glass & top fixing, as required) in all floors including suitable priming and painting including supply of all materials, staging and labour complete as per Technical Specification , approved drawing and as per direction of the EIC, excluding MS grill.
469Fitting and fixing of all type of Fixed glass in all floors including suitable priming and painting including supply of all materials, staging/scaffolding and labour complete as per Technical Specification , approved drawing and as per direction of the EIC, excluding MS grill.
470Fitting and fixing of all type of louvers/Ventilators in ground floors including suitable priming and painting including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC.
471Keeping arrangement for fixing of 300mm dia exhaust fan in all toilet block including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC.
472Keeping arrangement for fixing of 450mm dia exhaust fan in Cable spreader & GIS hall including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC.
473Fitting and fixing Stainless Steel railing in Staircase in all floors including supply of all materials and labour complete as per Technical Specification, approved drawing & requirement complete.
474Internal and External Sanitary and Plumbing works (of Integrated Building) in all floors (including Overhead water tanks, Rain water pipe & associated fittings and fixtures and all sanitary & plumbing accessories as required,as per approved drawing & tech, spec.) including their required connectivities complete in all respect including supply of all materials, staging and labour complete as per Technical Specification ,approved drawing and as per direction of the EIC.This item is for internal & external sanitary, plumbing works for the stated building in complete.
475Fitting and fixing of all MS FLAT & M.S. structural steel in indoor cable trench, Steel ladder, all Insert plates, crane guiding rail with holding angles, Chequered plate, cable support arrangement in cable spreader room, cable tray support structures (excluding the the cost of cable tray supply) etc with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection including supply of tool, tackles and labour complete as per Technical Specification, approved drawing, requirement complete and as per direction of the EIC. Steel work shall be painted with one coat of primer and two coats of paint in line with civil tech spec and requirement complete.
476Fitting and fixing of Steel ladder for access to different roof level including supply of all materials, staging (if reqd.) and labour complete as per Technical Specification & tender drawing.
477Fitting and fixing of 100MM wide Aluminium sheet (minimum thickness 2.0mm) including 25mm thk. sealing board & sealing component of approved make on expansion joints of vertical wall including supply of all materials, scaffolding/staging and labour as perTechnical Specification, direction of EIC & requirement complete.
478Laying of 25mm. thick damp proof course with cement concrete with stone chips (1:2:4) [with graded stone aggregate 10 mm nominal size] including supply of all other materials, labour & shuttering as per Technical Specification and approved drawing complete as per direction of the EIC.
479Anti termite treatment works including supply of all materials and labour complete as per Technical Specification & as per decision/direction of the EIC
480Filling in plinth with silver sand including supply, laying and saturation as per Technical Specification and approved drawing complete & as per decision/ direction of the EIC.
481Laying of 75 mm thk Brick Flat Soling including supply of all materials & labour as per Technical Specification and approved drawing complete and as per direction of the EIC.
482Laying of polythene sheet including supply of all materials & labour as per Technical Specification and approved drawing complete and as per direction of the EIC.
483Fitting and fixing of false floor with relevant grid system and false floor boards in line with Technical Specification and approved drawings, including supply of all materials of approved make, staging and labour & requirement complete & as per direction of the EIC. N.B.: No extra cost will be entertained for supply and laying of earth mat reinforcement / GI Flat as per recommendation of OEM and as per approved electrical drawings for integrated GIS Building. SUB-STRUCTURE (Below FGL)
484Concreting in sub-structure (Pile Cap, Grade beam & Column upto FGL) with Reinforced Cement Concrete M-25 grade including supply of all materials, labour & tools and tackles as required Including shuttering & Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
485Concreting in Plinth beam & indoor cable trench with Reinforced Cement Concrete M-25 grade including supply of all materials, labour & tools and tackles as required Including shuttering & Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
486Concreting in sub-structure (Pile) with Reinforced Cement Concrete M-25 grade including supply of all materials, labour & tools and tackles as required Including shuttering & Supply, cage lowering, welding & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection), complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
487Boring of 600mm dia Pile using bentonite to stabilize the bore and flushing the bore of excess mud with freshly prepared bentonite by using pump prior to placing concrete including supply of all materials, labour & tools and tackles as required up to the required depth as per Technical Specification and approved drawing complete.
488Head breaking of 600mm dia Pile including labour & tools and tackles as required up to the required depth as per Technical Specification and approved drawing complete.
489Installation of 6mm thick liner used for 600mm dia pile boring including supply of all materials, welding, labour & tools and tackles up to the required depth as per Technical Specification and Tender drawing complete.N.B: Requirement of liner will be finalized during detailed engineering based on actual requirement at site.
490Construction of fencing inside substation complete as per specification, tender drawing and requirement complete.
491Construction/installation of switchyard fencing (including supplying & fixing of MS angle,GI chain link fencing, flat etc. all complete) above brickwork in line with tender drawing inside sub-station complete as per technical specification and as per requirement complete.Necessary grouting shall be done after installation of MS Angle on brickwork as per requirement.
492Construction of brickwork, PCC/RCC Pedestal etc. below fencing structure arrangement inside sub-station complete keeping provision for fixing of MS Angle in line with tender drawing as per technical specification and as per requirement complete.
493Design and construction of 5.5 Mtr wide MS gate including trap gate including column, foundation as per tender drawing and technical specification to be fixed with the fencing & requirement complete Design & Construction of Boundary Wall & Gate:
494Design & construction of Boundary wall of 2.5M height above FGL with concertina fencing fitted & fixed above boundary wall as per technical specification and approved drawing, requirement complete and as per direction of EIC.
495Concreting with Reinforced Cement Concrete M-20 grade including supply of all materials, labour & tools and tackles as required Including shuttering & Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per tender drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
496Construction of 250mm thick Brick wall with 1:4 cement sand mortar and keeping provision for fixing of MS Angle as per technical specification and tender drawing including supply of all materials, labour & requirement complete and as per direction of EIC.
497Plaster on boundary wall with cement sand mortar (1:4) including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, staging (where necessary), materials, labour & requirement complete and as per direction of EIC.
498Applying exterior grade acrylic emulsion paint (two coats) over a layer of suitable primer (1 coat) in walls after necessary cleaning, smoothening including supply of all materials, staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC
499Increasing height by GI wire Mesh of boundary wall ( including supplying & fixing of MS angle, GI wire mess, flat etc. all complete) in line with tender drawing excluding concertina fencing with necessary grouting, priming painting as per technical specification and tender drawing including supply of all materials, labour, staging (if required) & requirement complete and as per direction of EIC.
500Installation of MS Angle on brick wall (including grouting) & concertina fencing fitted & fixed above MS angle (in line with tender drawing) including supply of all materials, staging and labour complete as per Technical Specification and approved drawing & requirement complete.
501Placing of 75mm dia PVC pipe along with graded filter (200x200x300mm) on each weep holes for drainage of water including supply of all materials, labour as required as per Technical Specification, approved drawing and requirement complete.
502Design & construction of 6.0 M wide MS gate (Manually operated) including trap gate to be fitted & fixed at the Main entrance of Substation 2.5m height from road top, with suitable arrangement for fixing of gate with boundary wall including column, foundation and all other necessary arrangement for lighting as per approved drawing, technical specification and requirement complete.
503Repair, maintenance of existing boundary wall (including reparing of dilapidated brick work but excluding plastering) of WBSEDCL including removal of spoils as per instruction of the EIC. Serviceable materials, if any, are to be handed over to WBSEDCL as per direction of EIC. (The work is to be excuted as site per direction of EIC and requirement complete.)
504Construction of Bituminous Road & Pathway:
5055.0 M Wide Water Bound Macadam Roads with Bituminous topping within sub-station area including construction of RCC/other type of crossings matching with the road top, concrete pavement, edging block as per specification, tender drawing, requirement complete and as per direction of EIC.
5064.0 M Wide Water Bound Macadam Roads with Bituminous topping within sub-station area including construction of RCC/other type of crossings matching with the road top, concrete pavement, edging block as per specification, tender drawing, requirement complete and as per direction of EIC.
507Design & construction of 2 M wide PCC pathway connecting different parts of sub-station switchyard etc. as per approved drawing, specification and requirement complete .
508Design & constructions of foundations for various switchyard structures, LM (lattice type), equipment structures (if any) including other Electro-mechanical equipment as per requirement as indicated in Electrical Schedule of Works and as per approved foundation layout drawing, foundation drawings and specification complete.
509Concreting in sub-structure with Reinforced Cement Concrete M-20 grade including supply of all materials, labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per drawing and Technical Specification etc. requirement complete (the work is to be executed in line with approved drawing and as per direction of the EIC). as per Technical Specification and approved drawing complete. All sorts of dewatering & shoring are included and will be done as per site requirement in consultation with EIC.The above item is inclusive of setting out & holding down Anchor fastener (including supply as required) / foundation bolts with Nut including anchor plate, washer (at bottom fitted complete and packing the hole by cement concrete or cement grout with admixture (as per civil tech. spec.).
5101. Design & constructions of 80 MVA & other transformer foundations with Rail cum road including other Electro-mechanical equipment foundation as per requirement, NIFPS Tank Foundation (if any) as indicated in Electrical Schedule of Works and as per approved drawings technical specification & requirement complete.2. Design & construction of oil / soak pits and sump pits (including connection of the same with the B.O.T) for the transformers , including requisite pipe lines for efficient discharge of burnt oil as per approved drawing and Technical Specification, & requirement complete
511Concreting in sub-structure with Reinforced Cement Concrete M-25 grade including supply of all materials, labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per drawing and Technical Specification etc. requirement complete (the work is to be executed in line with approved drawing and as per direction of the EIC). as per Technical Specification and approved drawing complete. All sorts of dewatering & shoring are included and will be done as per site requirement in consultation with EIC. The above item is inclusive of setting out & holding down Anchor fastener (including supply as required) / foundation bolts with Nut including anchor plate, washer (at bottom fitted complete and packing the hole with cement concrete or cement grout (as per civil tech. spec.).
512Concreting in sub-structure (Pile) with Reinforced Cement Concrete M-25 grade including supply of all materials, labour & tools and tackles as required Including shuttering & Supply, cage lowering, welding & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection), complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
513Boring of 600mm dia Pile using bentonite to stabilize the bore and flushing the bore of excess mud with freshly prepared bentonite by using pump prior to placing concrete including supply of all materials, labour & tools and tackles as required up to the required depth as per Technical Specification and approved drawing complete.
514Head breaking of 600mm dia Pile including labour & tools and tackles as required up to the required depth as per Technical Specification and approved drawing complete.
515Installation of 6mm thick liner used for 600mm dia pile boring including supply of all materials, welding, labour & tools and tackles up to the required depth as per Technical Specification and Tender drawing complete.
516Concreting in sub-structure with Reinforced Cement Concrete M-20 grade including supply of all materials, labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per drawing and Technical Specification etc. requirement complete (the work is to be executed in line with approved drawing and as per direction of the EIC). as per Technical Specification and approved drawing complete. All sorts of dewatering & shoring are included and will be done as per site requirement in consultation with EIC. The above item is inclusive of setting out & holding down Anchor fastener (including supply as required) / foundation bolts with Nut including anchor plate, washer (at bottom fitted complete and packing the hole with cement concrete or cement grout (as per civil tech. spec.).
517Fitting and fixing of Transformer rail, all M.S. structural steel, Insert plate etc. in transformer and soak pit with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection including supply of tools, tackles and labour complete as per Technical Specification ,approved drawing and as per direction of EIC. teel work shall be painted with one coat of primer and two coats of paint in line with civil tech spec and requirement complete.
518Laying of 150mm dia hume pipe (NP3) from soak pit to BOT including Inspection pits as per requirement including supply of all materials, labour as per Technical Specification and approved drawing, requirement complete and as per direction of the EIC.
519Laying of Gravel in Transformer Oil soak pit area of 300mm thickness including supply of all materials and labour complete as per Technical Specification & approved drawing
5201. Design & construction of outdoor cable trench including trench cover, MS Flat, MS angle etc. ( excluding supply of cable tray) as per requirement within switchyard complete as per approved drawing, specification and requirement. 2. Design & construction of storm water drainage system and sewerage disposal system (including soak wells/ground water recharge structure as per requirement) for entire substation area covered under the bid drawing including arrangement of suitable outfall structure complete, as per specification, approved drawing and requirement of Engineer-in-Charge. 3. Design & construction of Drain cum retaining wall under the bid drawing as per specification, approved drawing and requirement complete.
521Concreting in sub-structure with Reinforced Cement Concrete M-20 grade including supply of all materials, labour and tools & tackles as required Including shuttering and Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per drawing and Technical Specification etc. requirement complete (the work is to be executed in line with approved drawing and as per direction of the EIC). as per Technical Specification and approved drawing complete. All sorts of Dewatering & shoring is to be done as per site requirement in consultation with EIC.N.B: Items are inclusive of fitting & fixing of insert plate & MS angles including supply of all materials, labour etc.
522Laying of HDPE Pipes for sub trenchs for connection to equipements including supply of Pipes as per Technical Specification, approved drawing, labour & requirement complete.
523Fitting and fixing of all M.S. structural steel, Insert plate, MS angle, MS Grating etc. (excluding supply of cable tray) in outdoor cable trench and drain with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection including supply of tool tackles and labour complete as per Technical Specification & approved drawing. Steel work shall be painted with one coat of primer and two coats of paint in line with civil tech spec and requirement complete.
524Laying of 300mm dia Hume pipe (NP3) for drainage of water including Inspection pits as per requirement including supply of all materials, labour as per Technical Specification and approved drawing, requirement complete and as per direction of the EIC.
525Sinking of 01 (one) nos. deep tube well, including design, supply, installation of pump with interconnections for supply of water to various utilities, control room building as per Technical Specifications and approved drawing with necessary electrical connections, fittings, fixtures complete and commissioning.
526Construction of 01 (two) no. Deep Tube well as per Technical Specifications and as per direction of EIC with necessary electrical accessories of deep tube well as per requirement complete.
527Design & laying of Distribution pipe lines connecting various buildings and utilities complete as per Technical Specification, direction of EIC & requirement complete.
5281. Design & construction of fire fighting reservoir with pump house of capacity 60 cum as per technical specification & approved drawing, requirement complete.2. Design & construction of burnt oil tanks / oil water sumps to be connected to the drainage system complete, as per requirement, Technical Specification, approved drawing and requirement complete. 3. Design & Construction of sumps, pump house and supply & installation of sump pump as per direction of EIC and as per requirement complete. 4. Construction of Security Goomty (Area = 6 sq.m. approx.) as per uploaded tender drawing, technical specification & requirement complete. N.B: Supply & fixing of 230mm wide rubber water stopper & Manhole cover shall be included as per requirement.
529Concreting in with Reinforced Cement Concrete M-25 grade including supply of all materials,labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement including distribution bars, spacers, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
530Concreting in with Reinforced Cement Concrete M-20 grade including supply of all materials,labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement including distribution bars, spacers, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and Technical Specification etc. requirement complete and as per direction of EIC. All sorts of dewatering & shoring are included & will be done as per site requirement in consultation with EIC.
5311st Class Clay Brick Work in all floors including supply of all materials, staging & labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC.
532250thk. Brick wall with cement mortar (1:4) including supply of all materials, scaffolding/staging & labour complete
533Plaster (to wall, floor, ceiling etc.) with sand and cement mortar in all floors including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging (where necessary) including materials, labour & cost of chipping over concrete surface as per Technical Specification and approved drawing complete and as per direction of the EIC.
534Internal walls in cement sand ratio (1:4) including supply of all materials, scaffolding/staging & labour complete
535External walls in cement sand ratio (1:4) including supply of all materials, scaffolding/staging & labour complete
536Ceiling in cement sand ratio (1:3) including supply of all materials, scaffolding/staging & labour complete
537Applying interior grade acrylic distemper (two coats) of over a coat of solvent based primer (1 coat) on new surface after necessary cleaning, smoothening of surface including supply of all materials staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC
538Applying exterior grade acrylic emulsion paint (two coats) over a layer of suitable primer (1 coat) in all outside walls after necessary cleaning, smoothening including supply of all materials, scaffolding/ staging and labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC
539Fitting and fixing of MS Doors, Windows, fixed glass, louver, ventilator etc. with MS grill (as required), 75mm dia GI pipe, Railing, Manhole cover & other fittings as required for Fire fighting pump house including suitable priming and painting including supply of all materials and labour & requirement complete as per Technical Specification , approved drawing and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.
540Fitting and fixing of MS Doors, Windows, fixed glass, louver, ventilator etc. with MS grill (as required), 75mm dia GI pipe, Railing, Manhole cover & other fittings as required for Sump Pump & Pump house including suitable priming and painting including supply of all materials and labour & requirement complete as per Technical Specification, approved drawing and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.
541Fitting and fixing of MS Doors, Windows etc. with MS grill (as required), & other fittings as required for Security goomty including suitable priming and painting including supply of all materials and labour & requirement complete as per Technical Specification, approved drawing and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC and requirement complete.
542Flooring & Skirting of fire fighting pump house, sump pump house and security goomty including supply of all materials and labour complete as per Technical Specification & approved drawing and as per direction of EIC.
543Roof Treatment works in building roof including supply of all materials, staging and labour complete as per Technical Specification , approved drawing and as per direction of the EIC.
544Applying epoxy paint (in line with the manufacturer specification) of approved colour inside the burnt oil tank (wall & floor) as per direction of the EIC including supply of all materials and labour complete. However application of the paint shall be done at site by the authorized applicator of the paint manufacturer.
545Fitting and fixing of all GI pipes & M.S. structural steel, Insert plate etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection including supply of tool, tackles and labour complete as per Technical Specification, approved drawing and as per direction of EIC. Steel work shall be painted with one coat of steel primer and two coats of synthetic enamel paint as per direction of the EIC.
546EARTHING SYSTEM COMPLETE
547Supplying & Laying of 100 mm thick Crushed stone as per approved layout and Technical Specification & requirement complete including supply of all materials, labour & tools and tackles as required.
548Laying of 75 mm thick P.C.C (1:4:8) with Jhama bricks at switch yard earthmat area as per approved layout and Technical Specification & requirement complete including supply of all materials, labour & tools and tackles as required Including shuttering.
549MISCLLANEOUS ITEMS (As will be required for successful commisioning of the work in all respect)
550Earthwork in excavation of foundation up to 1.5M in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m or as directed. The items includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as per approved drawing, technical specification,including labour and requirement complete.Sl. No. 32 of Civil Tech Spec. annexure is included & will be done as per site requirement in consultation with EIC.
551Earthwork in excavation of foundation from 1.5M to 3.0M in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m or as directed. The items includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as per approved drawing, technical specification,including labour and requirement complete. Sl. No. 32 of Civil Tech Spec. annexure is included & will be done as per site requirement in consultation with EIC.
552Earthwork in excavation of foundation from 1.5M to 3.0M in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m or as directed. The items includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as per approved drawing, technical specification,including labour and requirement complete. Sl. No. 32 of Civil Tech Spec. annexure is included & will be done as per site requirement in consultation with EIC. N.B.: The above 2 items are to be read in conjunction with Sl. No. 32 of Civil Tech Spec. annexure.
553Earthwork in filling of foundation trenches or plinth with good earth, in layers not exceeding 150mm including watering and ramming etc. layer by layer as per approved drawing, technical specification, including labour and requirement complete.
554Concreting with Cement Concrete M-10 grade including supply of all materials and labour inclusive of shuttering as per Technical Specification and approved drawing complete and as per direction of EIC.
555Concreting with Cement Concrete M-15 grade including supply of all materials and labour inclusive of shuttering as per Technical Specification and approved drawing complete and as per direction of EIC.
556Concreting with Reinforced Cement Concrete M-20 grade including supply of all materials, labour and tools & tackles as required Including shuttering, staging and Supply & laying of Reinforcement (for main, distribution bars, spacers, stirrups/links, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection) complete as per approved drawing and Technical Specification etc. requirement complete and as per direction of EIC.
557Neat cement punning (~1.5mm thick) in all floors including supply of all materials and labour complete as per Technical Specification and approved drawing complete and as per direction of EIC.
558Filling below foundation with medium coarse saturated sand (F.M of 2.6 to 2.9, wherever required) including supply of all materials, labour & laying as per Technical Specification and approved drawing complete and as per direction of EIC.
559Construction of Septic Tank, Soak Pit and Inspection Pit including their required connectivities including supply of all materials and labour complete as per Technical Specification & tender drawing.
560For 15 Users
5611st Class Clay Brick Work in foundation/substructure including supply of all materials & labour complete as per Technical Specification and approved drawing complete and as per direction of the EIC.
562250thk. Brick wall with cement mortar (1:6) including supply of all materials, scaffolding/staging & labour complete
563125thk. Brick wall with cement mortar (1:6) including supply of all materials, scaffolding/staging & labour complete
564Fitting & fixing of 22gauge GI sheet along with support structure to be used as roof of DG Shed including supply of all materials & labour complete as per Technical Specification and approved drawing complete and uploaded tender document. Item Rate BoQ BoQ_Ver3.0 Item Rate Normal Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (PROCUREMENT) Name of Work: Sub-Station and Transmission Line (PACKAGE-C12) NIT No.:- CE(P)/WBSETCL/Composite Pkg–C12 (2nd Call)/26-27/33 DT: 16.10.2026 Bidder Name : NUMBER # TEXT # TEXT # NUMBER TEXT #
5652.0 Additional involvement of Communication works for Construction of Sadarghat 132/33 KV Substation Item4 15 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos Sl.No. Description of work Item5 15 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos
566Dismantling of old (existing) PLCC / DPC panels at each Sub-Station including linking Sub-Stations , wherever necessary and transportation & unloading the same to any WBSETCL stores suitable place suggested by the controlling officer shall under the scope of vendor.
567Tit bit civil works like repairing/extension of existing cable trench, extension of base mounting channel over cable trench for placing Digital Protection Coupler /Fibre Optic & other associated panels etc. wherever necessary at each Sub-Station including linking Sub-Stations shall under the scope of vendor.
568Integration of same EPAX with PLCC panel & Fibre Optic panel (at each Sub-Station and linking Sub-Station) with the PLCC (existing & new both) & Fibre Optic network (existing & new both) shall be under the scope of vendor.
569Integration of Digital Protection coupler with Fibre Optic panel (existing & new both) & PLCC network (existing & new both) and C & R panel at each Sub-Station including linking Sub-Stations for carrier aided protection shall be under the scope of vendor.
570Establishment of Fiber optic communication for voice and data communication of Sadarghat Sub Station with existing Burdwan SubStation and Satgachia Substation shall be under the scope of the bidder.
571VoIP Phones will be provided by Communication Department ,WBSETCL for Voice communication over VoIP. Arangement/Extension of AC supply for VoIP Phones at Control room, communication room, Sub-Station In-charge's room along with laying of STP Data Cable(CAT 6) with flexible GI conduit pipe from FO panel to VoIP phones and tit-bit work shall under the scope of vendor. Name of The Connecting Link: 132 KV System Item12 15 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 1. Sadarghat-Burdwan Circuit I & II 2. Sadarghat-Satgachia Circuit I & II Item Rate BoQ BoQ_Ver3.0 Item Rate Normal Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (PROCUREMENT) Name of Work: Sub-Station and Transmission Line (PACKAGE-C12) NIT No.:- CE(P)/WBSETCL/Composite Pkg–C12 (2nd Call)/26-27/33 DT: 16.10.2026 Bidder Name : NUMBER # TEXT # TEXT # NUMBER TEXT #
5722.0 QUANTITY OF FIBER OPTIC COMMUNICATION EQUIPMENT AND MATERIALS FOR Sadarghat 132/33 KV SUB-STATION PACKAGES 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos SL No Description Sadarghat Substation Burdwan Substation Satgachia Substation Total 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 1) Fibre Optic Terminal equipment ( with minimum five redundant directions with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at Burdwan, Satgachia, SLDC & Backup SLDC for data and voice communication and carrier aided protection). Nos. 1.0 0.0 0.0 1.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 2) E1 Interface cards( Minimum 16 interfaces/card) Nos. 2.0 0.0 0.0 2.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 3) Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) Nos. 2.0 0.0 0.0 2.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 4) Equipment Cabinets Nos. 1.0 0.0 0.0 1.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 5) Main Distribution Frame (100 pairs) Lot 1.0 0.0 0.0 1.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 6) Pre-connectorised optical fibre patch cords as per requirement Lot 1.0 1.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 7) E-1 Port Interfacing Cable Lot 1.0 1.0 2.0 Construction of chamber for 100mm sluices valve item3 10.0 Nos 08) EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4x 8 nos.) Local Subscribers Set 1.0 0.0 0.0 1.0 09) Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum Eight commands as per Technical Specification requirement. Nos. 4.0 2.0 2.0 8.0 10) Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control & office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. Nos. 8.0 2.0 2.0 12.0 11) Telephone cable (armoured) for all other 2-wire telephones & other requirements as per specification and as per requirement. Lot 1.0 1.0 12) STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charge's room etc.) with FO Panel. Lot 1.0 1.0 13) Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing Lot 1.0 1.0 14) 48V, 300AH VRLA type Battery Set 2.0 0.0 0.0 2.0 15) 48V, 60A Battery Charger Nos. 2.0 0.0 0.0 2.0 16) 48V DCDB as per technical specification Nos. 1.0 0.0 0.0 1.0 17) Integration with existing Fiber Optic System at connecting Sub-Station on optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end.i) for voice & data communication ii) for carrier aided protection purpose-with supply of equipment and material (SFP,Patchcord, etc ) as required. Intigration of new SDH, with existing SDH at connecting substations, must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. Lot 0.0 1.0 1.0
5732.0 PART - I
574Standard large angle 'DD' type towers (30o to 60o) & Dead end Superstructure (including modified tower for auxiliary cross arm, if any) Stub - set of 4 upto 6 metre extension
575Standard Suspension 'A4' type M/C towers (0o to 2o) Superstructure Stub - set of 4 upto 6 metre extension
576Standard small and medium angle 'B4' type M/C towers (2o to 30o) Superstructure Stub - set of 4 upto 6 metre extension
577Standard large angle 'C4' type M/C towers (30o to 60o ) Dead End Superstructure Stub - set of 4 upto 6 metre extension
578Standard large angle 220KV 'LT4' type towers (30o to 60o) & Dead end Superstructure Stub - set of 4 upto 12/15 metre extension
579Extensions only +3 Metre Body Extension for 132 KV 'DD' type tower. +6 Metre Body Extension for 132 KV 'DD' type tower. +3 Metre Body Extension for 132 KV 'A4' type tower. +6 Metre Body Extension for 132 KV 'A4' type tower. +3 Metre Body Extension for 132 KV 'B4' type tower. +6 Metre Body Extension for 132 KV 'B4' type tower. +3 Metre Body Extension for 132 KV 'C4' type tower. +6 Metre Body Extension for 132 KV 'C4' type tower. +12 Metre Body Extension for 220KV 'LT4' type tower. +15 Metre Body Extension for 220KV 'LT4' type tower.
580Number Plate
581Danger Plate
582Phase Plate (in sets of three Red, Yellow, Blue)
583Circuit Plate
584Complete pipe type grounding material for tower
585Barbed wire type anti-climbing device Special Tower / Tower structure
586(For power line x-ing, river x-ing, rail x-ing, N.H. x-ing, auxiliary x-arm, extended stub etc.for all non-scheduled tower/tower structure including 220KV M/C Composite Tower MDCT) and in line with technical specification Stub ( per tonne rate to be quoted) Fabricated members (MS) Fabricated members (HT) Bolts & nuts Superstructure ( per tonne rate to be quoted) Fabricated members (MS) Fabricated members (HT) Bolts & nuts PART - II
587ACSR PANTHER CONDUCTOR
588ACCC HTLS CONDUCTOR EQUIVALENT TO ACSR PANTHER
589COMPOSITE FIBER OPTIC OVERHEAD EARTHWIRE (48F OPGW) STANDARD LENGTH (KM) AS PER TECHNICAL SPECIFICATION.
59024 FIBER OPTIC APPROACH CABLE (ARMOURED) INCLUDING ALL HARDWARES, TIES, CLIPS, CLEATS, CONDUITS, DUCTS, SUPPORTING FITTINGS ETC. AND OTHER MATERIALS WHICHEVER REQUIRED FOR COMPLETE INSTALLATION AS PER TECHNICAL SPECIFICATION AND REQUIREMENT.
591SUPPLY OF 96F FIBER OPTIC DISTRIBUTION PANEL (FODP) SUITABLE FOR APPROACH CABLE INDOOR TYPE WITH FC-PC COUPLING AND PIGTAILS (DWSM FIBER) AS PER TECHNICAL SPECIFICATION PART - III
592132 KV SUSPENSION INSULATOR STRING (70KN) - 1x09Nos. PORCELENE DISC INSULATOR OR PORCELENE LONG ROD INSULATOR OR POLYMER LONG ROD INSULATOR
593132 KV TENSION INSULATOR STRING (120KN) - 1x10Nos. PORCELENE DISC INSULATOR OR PORCELENE LONG ROD INSULATOR OR POLYMER LONG ROD INSULATOR PART - IV
594CONDUCTOR ACCESSORIES :(suitable for ACSR Panther) MID SPAN COMPRESSION JOINT REPAIR SLEEVE VIBRATION DAMPER (suitable for ACSR Panther conductor - One set includes average quantity of Vibration Dampers required for one span OF MULTI CIRCUIT TOWER with two circuits as per approved drawing, design & specification) VIBRATION DAMPER (suitable for ACSR Panther conductor - One set includes average quantity of Vibration Dampers required for one span OF DOUBLE CIRCUIT TOWER as per approved drawing, design & specification)
595CONDUCTOR ACCESSORIES :(suitable for ACCC HTLS Conductor equivalent to ACSR Panther) REPAIR SLEEVE VIBRATION DAMPER (suitable for ACCC HTLS Conductor equivalent to ACSR Panther - One set includes average quantity of Vibration Dampers required for one span OF MULTI CIRCUIT TOWER with two circuits as per approved drawing, design & specification) VIBRATION DAMPER (suitable for ACCC HTLS Conductor equivalent to ACSR Panther - One set includes average quantity of Vibration Dampers required for one span OF DOUBLE CIRCUIT TOWER as per approved drawing, design & specification)
596OPGW EARTHWIRE ACCESSORIES : VIBRATION DAMPER for OPGW (One set includes quantity of Vibration Dampers required for one span of OPGW length as per approved drawing, design & specification) SINGLE SUSPENSION CLAMP ASSEMBLY WITH EARTH BOND DOUBLE TENSION CLAMP ASSEMBLY (PASS THROUGH) WITH EARTH BOND SINGLE TENSION CLAMP ASSEMBLY WITH EARTH BOND DOWN LEAD CLAMP for OPGW (to be fixed at an interval of 1.5 mtr) OPGW HOLDER BRACKET JOINT BOX FOR D/C PORTION
597INSULATOR HARDWARES WIITH SUITABLE CLAMP & CONNECTORS FOR ACSR PANTHER CONDUCTOR SINGLE SUSPENSION INSULATOR HARDWARE FITTINGS COMPLETE (A. G. Type) DOUBLE SUSPENSION INSULATOR HARDWARE FITTINGS COMPLETE (A. G. Type) SINGLE TENSION INSULATOR HARDWARE FITTINGS COMPLETE DOUBLE TENSION INSULATOR HARDWARE FITTINGS COMPLETE PILOT INSULATOR HARDWARE FITTINGS COMPLETE
598INSULATOR HARDWARES WIITH SUITABLE CLAMP & CONNECTORS FOR ACCC HTLS CONDUCTOR EQUIVALENT TO ACSR PANTHER CONDUCTOR SINGLE SUSPENSION INSULATOR HARDWARE FITTINGS COMPLETE (A. G. Type) DOUBLE SUSPENSION INSULATOR HARDWARE FITTINGS COMPLETE (A. G. Type) SINGLE TENSION INSULATOR HARDWARE FITTINGS COMPLETE DOUBLE TENSION INSULATOR HARDWARE FITTINGS COMPLETE PILOT INSULATOR HARDWARE FITTINGS COMPLETE PART - V (SPARE)
599ACCC HTLS CONDUCTOR EQUIVALENT TO ACSR PANTHER
600HTLS CONDUCTOR ACCESSORIES (SPARE): MID SPAN COMPRESSION JOINT REPAIR SLEEVE RIGID SPACERS FOR JUMPERS SINGLE TENSION HARDWARE FITTINGS COMPLETE (HTLS) DOUBLE TENSION HARDWARE FITTINGS COMPLETE (HTLS)
601ERECTION PART Detail Survey including route alignment preparation of profiles & Schedules of towers. Check survey and final peg marking
602Setting of stubs : 132KV D/C 'DD' type towers & dead end up to +6 MBE 132KV M/C 'A4' type towers up to +6 MBE 132KV M/C 'B4' type towers up to +6 MBE 132KV M/C 'C4' type towers & dead end up to +6 MBE 220KV M/C 'LT4' type towers up to +12/15 MBE
603Soil resistivity test as per specification and direction of EIC
604Design and Construction of tower foundation in all types of soil and conditions as per foundation drawing approved by the purchaser including excavation, concreting (M-20 grade) over lean concrete (M-10 grade, of 50 mm minimum thickness), steel reinforcement, shoring, shuttering, dewatering, backfilling with carried earth (where necessary) and/or excavated good soil, disposal of surplus soil, forms, mixing, placing, finishing, protection and curing of concrete with all cost of supply of materials such as cement, sand, coarse aggregate, water, reinforcement, mild steel angle etc., with all cost of labour, materials, tools, plants, incidentals etc. complete in all respect as per specification and/or as directed by the employer. Rates shall be quoted in respective price schedule on per tower basis. 132 KV ''DD' type tower foundation upto +6 MBE Partially sub-merged type Fully sub-merged type 132 KV ''A4' type tower foundation upto +6 MBE Wet type Partially sub-merged type Fully sub-merged type 132 KV ''B4' type tower foundation upto +6 MBE Wet type Partially sub-merged type Fully sub-merged type 132KV ''C4' type tower foundation upto +6 MBE Wet type Partially sub-merged type Fully sub-merged type 220KV 'LT4' type towers & dead end for up to +12/15 MBE Fully sub-merged type
605Design and Construction of RCC bore pile foundation with pile cap and chimney for river crossing & anchor towers in all types of soil and conditions as per foundation drawing approved by the purchaser including stub setting and grounding of tower with all earthing materials of M.S. flat, pipe, salt, charcoals etc, of M25 grade concrete of design mix or nominal mix not leaner than 1:1:2 and reinforcement of grade Fe-500 with all cost of supply of materials such as cement, sand, coarse aggregate, water, reinforcement, M.S. liner of 6mm thick etc. and all cost of labour, tools, plants, incidentals etc. complete in all respect as per specification and/or as directed by the employer. Workmanship shall be followed as per IS:456 and IS:2911 including cube testing etc and the rate shall be inclusive of all cost. M.S. liner of 6mm thick shall be provided from cut-off level up to requisite depth. Rate of pile foundation shall be quoted in running meter where length shall be measured from cut-off level 1200mm uniform dia up to 25M 1200mm uniform dia 25-30M 1200mm uniform dia 30-35M
606Superstructure erection of standard normal tower including all work above ground level including tack welding excluding hoisting of insulator, fitting of danger, number & phase plates and anticlimbing devices etc. 132 KV 'DD' type towers & dead end 132 KV 'A4' type towers 132 KV 'B4' type towers 132 KV 'C4' type towers 220KV 'LT4' type towers & dead end upto +12/15 MBE
607Extensions only : +3 Metre Body Extension for 132 KV 'DD' type tower. +6 Metre Body Extension for 132 KV 'DD' type tower. +3 Metre Body Extension for 132 KV 'A4' type tower. +6 Metre Body Extension for 132 KV 'A4' type tower. +3 Metre Body Extension for 132 KV 'B4' type tower. +6 Metre Body Extension for 132 KV 'B4' type tower. +3 Metre Body Extension for 132 KV 'C4' type tower. +6 Metre Body Extension for 132 KV 'C4' type tower. +12 Metre Body Extension for 220KV 'LT4' type tower. +15 Metre Body Extension for 220KV 'LT4' type tower.
608Laying, stringing, tensioning, clamping, jointing etc. complete of 6 nos. of ACSR Panther conductor including hoisting of insulators, armour rods, dampers and other accessories for complete route Km for multi circuit. Laying, stringing, tensioning, clamping, jointing etc. complete of 6 nos. of ACCC HTLS Conductor equivalent to ACSR Panther including hoisting of insulators, armour rods, dampers and other accessories for complete route Km for multi circuit. Laying, stringing, tensioning, clamping, jointing etc. complete of 6nos. of ACSR Panther conductor including hoisting of insulators, armour rods, dampers and other accessories for complete route Km for double circuit. Laying, stringing, tensioning, clamping, jointing etc. complete of 6nos. of ACCC HTLS conductor including hoisting of insulators, armour rods, dampers and other accessories for complete route Km for double circuit. Laying, stringing, tensioning, clamping, jointing etc. of one earthwire (48F-OPGW) including earth bonding with tower, fitting, fixing of all necessary accessories for complete route Km.
609Installation of approach cable (armoured) complete including ties, clips, cleats, conduits, ducts, supporting fittings etc. and other materials whichever and wherever required as per technical specificaiton.
610Installation of 96F FODP indoor type complete with all connections as per technical specificaiton and requirement.
611Fittings of tower accessories Number plate Danger plate Phase plate (in set of three) Circuit Plate Barbed wire type anticlimbing devices
612Grounding work for pipe earth including cost of coke, salt etc. including necessary excavation and backfilling complete.
613Erection of Special Tower / Tower structure (For power line x-ing, river x-ing, rail x-ing, N.H. x-ing, auxiliary x-arm, extended stub etc.for all non-scheduled tower/tower structure) including 220KV MDCT tower and in line with technical specification. Stub setting and footing work excluding the cost of excavation,concreting & back filling of Special Tower (including 220KV M/C Composite Tower MDCT) other than bored pile locations. Superstructure erection of Special Tower ( including 220KV M/C Composite Tower MDCT) including tack welding and in line with technical specification.
614UNIT RATES : Concrete M-10 per cubic metre (Cum.) including supply of cost of all materials complete, including dewatering. Concrete M-20 per cubic metre (Cum.) including dewatering, supply of all materials & shuttering but excluding reinforcement. Supply, bending & binding of reinforcement rod including cost of binding material & labour complete.
615Earth Work : (Excavation including compacted back filling & required dewatering) Normal dry soil - Do - wet soil - Do - P.S. soil - Do - F.S. soil & Hard Rock (without blasting)
616Shoring of pits with shuttering, supply of materials & labour
617Dewatering of pits Manual per man hour Mechanical pump (Rate to be quoted in H.P-Hr.)
618Cost of Building revetments with bricks, with 1 : 6 cement morter including 12 mm thick cement plaster (1:4) and neat cement punning on all exposed surfaces, excavation per cubic metre of brickwork including supply of materials and transport. Back filling and levelling of the volume of earth enclosed by revetment walls. (Good earth arranged & supplied by the contractor) including supply of materials, transport etc. complete. Back filling with medium coarse sand in foundation trench/pit as per specification and/or as per direction (per cum.). Cost of compaction of brick bats in foundation trench as per specification and/or as per direction (per cum.) of EIC including supply of all materials and transport complete.
619Soil testing as per relevant IS codes and direction of EIC Upto 10 M depth Upto 40 M depth
620Shoring of pits with shuttering, supply of materials & labour
621Dismantling of 132 KV D/C erected tower structures including insulators, hardwares, anticlimbing device, barbed wire etc.and hand over the same to WBSETCL's store as per instruction of the controlling officer (per tower L.S.) Removal of only 6 Nos. ACSR Panther conductor per route KM of existing 132 KV D/C line including existing earth wire/ OPGW and handed over to WBSETCL storeas per instruction of the Controlling officer. (Rate to be quoted as per route Km basis) Rivetment work by providing Sal-bullah / Eucalyptus bullah piles of diameter not less than 150mm, driving upto desired depth but not less than 4 m and spacing as per approved design and joining each bullah piles with the staging props by proper arrangement capable to transmit the loads from superstructure, including supply of pile, double coat coal tarring on wooden surface and all complete. Drum Sheet Walling to be provided of 1.40m (av.) high on Sal-bullah /Eucalyptus bullah piling 15 cm dia. and 3.25m long driven 1.75m (av.) below G.L. and 75cm centre to centre including fitting fixing 3 nos. of half bullah pieces (from 10 cm dia) and drum(empty bitumen) sheet (approved condition) of height 1.5m , cutting and straightening drum sheet (each joint must have lap length of min.50mm) including cost of necessary nails, bolts, nuts etc Note : 1. Diameter of bullah to be measured at 1.5 m from thicker end. Note : 2. Projected area of the deck on river bed should be considered for arriving at the cost. Rate to be quoted based on per meter length of pile Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58074177
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 11-11-2026
Authority
Authority Name West Bengal State Electricity Trasnmission Company Limited
Work Description Tender for Sub-Station And Transmission Line (Package-C12)
Basic Detail
Tender No CE(P)/WBSETCL/Composite Pkg-C12 (2nd Call)/26-27/33 DT 16.10.2026
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 16 Oct 2026
Submission Date 11 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.50 Crore
Exemption Not Available
Document List
74875da9-c2d9-4778-a859-e008683d72b8.html
All_Specification.rar
Annexure.pdf
Bid_forms.pdf
BOQ_2564877.xls
Drawing_1.rar
Drawing_2.rar
Drawing_3.rar
JOINT_DEED.pdf
Prebid_format.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 24 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

74875da9-c2d9-4778-a859-e008683d72b8.html

rar

All_Specification.rar

pdf

Annexure.pdf

pdf

Bid_forms.pdf

xls

BOQ_2564877.xls

rar

Drawing_1.rar

rar

Drawing_2.rar

rar

Drawing_3.rar

pdf

JOINT_DEED.pdf

xls

Prebid_format.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender