Tender For Construction Of 1X Seciurity Post Alongwith Path Way Of 150M X 4 Feet Crossed Interlocking Tiles Form Barrack To The Post At 21 Sub Area Pro Unit Under Ge (West) Pathankot
Tender Value
7.63 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
14 days left
EMD
15260
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 1X Seciurity Post Alongwith Path Way Of 150M X 4 Feet Crossed Interlocking Tiles Form Barrack To The Post At 21 Sub Area Pro Unit Under Ge (West) Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I B/R PortionExcavation in trenches in exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, etc or for shaft, wells, cesspits, manholes, pier holes, etc, n.exc 10 sqm on plan and n exc 1.50 in depth and getting out in hard/dense soil complete all as specified. |
| 2 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 4 | Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 5 | M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm rammed to a true surface complete all as specified and directe. |
| 6 | M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub floor, Sub bases, floors and pavings etc complete all as specified and as directed. |
| 7 | Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed. |
| 8 | Formwork to Square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 9 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 10 | M&L TMT bars 6mm to 8 mm cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 11 | M&L TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. |
| 12 | M&L Reinforce cement concrete M-25 (Designmix) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 13 | M&L Reinforce cement concrete M-25 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 14 | M&L Reinforce cement concrete M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 15 | M&L Reinforce cement concrete M-25 (Design mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 16 | M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and as directed. |
| 17 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces wall in cm 1:6 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 18 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces of wall in cm 1:4 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 19 | M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in cm 1:3 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 20 | Providing and mixing water proofing material in cement concrete per 50kg work in doses by weight of cement complete all as specified and directed by Engr-in-charge. |
| 21 | M&L for preparation of newly plaster surfaces of walls and applying two coats of cement base paint over a priming coat of alkalies resistance priming paint complete all as specified. |
| 22 | M&L for preparation of newly plaster surfaces of walls and applying three coats of white wash over ceiling complete all as specified and as directed. |
| 23 | M&L machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over screed bed or bedding layer 20 mm thick in cement mortar 1:4, complete all as specified and as directed.Note :- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm . |
| 24 | S&F pressed steel frames 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 25 | S&F Factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 26 | M&L for preparation of newly wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 27 | S&F 250mm long Aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminum alloy and fixed complete all as specified and directed. |
| 28 | S&F 200mm long aluminum, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 29 | S&F Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed by Engr-in-Charge. |
| 30 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil for roads to required slope gradient, camber etc complete all as directed. |
| 31 | M&L hardcore of broken stone or boulders of gauge n.exc.63mm,deposited,spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface. |
| 32 | M&L cement concrete in foundation type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete. |
| 33 | M&L 80mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006, M-35 Grade complete all as specified and directed. |
| 34 | M&L 30 mm thick Sand filling under floors or in foundations including watering and consolidation all as specified and directed . |
| 35 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills,steps,and other similar bands,plinth courses, string courses, lacing courses, parapets and railing upto 60cm height,copings,kneelers,apex stone,bed plates and the like including weathering slightly rounded or chamfered angles and throating, all as specified and directed. |
| 36 | Sch 'A' Part-I B/R PortionM&L for Modular point wiring for one light/one fan controlled by one switch with 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit ISI maked heavy duty for one light fan/bell point controlled by one switch including suitable MODULAR cover plate and MODULAR metallic boxes of suitable way matching with surrounding including PVC green insulated unsheathed 1.5 sqmm multistrand copper conductor FRLS cable as continous earthwire and connecting to earth duly, complete all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) (c) Metallic flush box should of same make of modular switch socket. |
| 37 | All as per srl item No 36 here-in-before but MODULAR 3 pin 5 amps socket outlet on the independent board with other switch complete all as specified and directed. |
| 38 | All as per srl item No 36 here-in-before but MODULAR 3 pin 5 amps socket outlet on same Board complete all as specified and directed. |
| 39 | All as per srl item No 36 here-in-before but MODULAR 15/16 Amps socket outlet on independent board with 2.5 sqmm copper conducter FRLS cale and 2.5 sqmm PVC insulated unsheathed copper conductor cable FRLS (Green Colour) as earth lead complete all as specified and directed. |
| 40 | S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed. |
| 41 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 42 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 43 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 44 | M&L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed. |
| 45 | S&F 20W surface / wall mounted LED fitting, extruded aluminium housing with Polycarbonate diffuser and inbuilt ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 110 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 46 | S&F osciliating Pedestal fan 400mm with energy efficient heavy duty motor having 2250RPM and 90CMM with superior speed and high air delivery including base for stability complete all as specified and directed by Engr-in-charge. |
| 47 | S&F LED flood light, powder coated pressure die cast aluminium body high efficiency LED flood light 120Watt with built in driver having efficiency >85%, Input voltage 140-270 volt AC, Frequency 50/60Hz, operating temp range -5 to 50 degree Centigrade, internal surge protection 5 KV L,N,E as per IEC 61000-4-5, THD <10%, PF> 0.95, IP 66K, IK 10, CRI > 70, lenses for beam angle 30 deg - 120 deg , suitable tiltable fitting, minimum 50000 burning hours and making connections using flexible copper cable of suitable size from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 48 | S&F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge. |
| 49 | S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 40 Amp all as specified and directed. |
| 50 | S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 40 Amp all as specified and directed. |
| 51 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. Note :- The rate quoted include cost of min 7.5 metre earthing wire |
| 52 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2core |
| 53 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified Note: Punned thickness of sand to be consider for measurement purpose. |
| 54 | M&L for old size Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed. |
| 55 | M&L for GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall / pole (Rates incl accessories such as bend, clamps, nuts bolts and washers req for fitting) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender