Tender For Comprehensive Repair, Maintenance & Servicing Of Eot Gantry Cranes Of Capacity 5X10 Ton & 1X5 Ton Respectively And Other Connected Misc Allied Works At Tp Complex At Af Stn Digaru.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Nov 2026
8 days left
EMD
29000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Repair, Maintenance & Servicing Of Eot Gantry Cranes Of Capacity 5X10 Ton & 1X5 Ton Respectively And Other Connected Misc Allied Works At Tp Complex At Af Stn Digaru.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for perodic inspection/servicing of 10 Ton capacity flame proof EOT crane of any make installed at different buildings/location at TP site, to be carried out in every three months and making/keeping the cranes in serviceable condition complete all as specified and directed with and including operations for maintenance specified as under:-Note- Inspection /Servicing of 05 Nos FLP 10 Ton Cap EOT crane has to be carried out quartely basis. |
| 2 | (A) LONG TRAVERSE MOTION- (a) Checking gear box oil level, checking and rectification of leakage if any and filling with new oil up to required level.(b) Checking functioning of all brakes of any capacity and making adjustment for proper working.(c) Checking motion wheels for any abnormal sound & checking mounting /fixing arrangment .(d ) Checking of grease in geared coupling and tighting of nut /bolts etc.(e) Checking of motion cut off at extreme ends with limit switches.(f) Checking drive shaft and couplings including tighting of nut and bolts.(g) Checking oil in FLP thrustors checking any leakage any filling with new oil.(h) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including replacing burnt out/over heated cable ends if any. |
| 3 | (B) CROSS TRAVERSE MOTION (a) Checking gear box oil level, checking and rectification of leakage if any and filling with new oil up to required level.(b) Checking functioning of all brakes of any capacity and making adjustment for proper working.(c) Checking motion wheels for any abnormal sound &checking mounting /fixing arrangment .(d ) Checking of grease in geared coupling and tighting of nut /bolts etc.(e) Checking of motion cut off at extreme ends with limit switches.(f) Checking drive shaft and couplings including tighting of nut and bolts.(g) Checking oil in FLP thrustors checking any leakage any filling with new oil.(h) Checkinh terminal connection of all Cross traverse motion of three phase FLP electric motor and tightening properly including replacing burnt out/over heated cable ends if any. |
| 4 | (C ) HOIST MOTION(a) Checking gear box oil level, checking and rectification of leakage if any and filling with new oil up to required level.(b) Checking functioning of all brakes of any capacity and making adjustment for proper working.(c) Checking the steel wire rope for any damage, greasing the same & checking mounting /fixing arrangment the same.(d ) Checking of grease in geared coupling and tighting of nut /bolts etc.(e) Checking of motion cut off at extreme ends with limit switches.(f) Checking bearing of the rope drum, greasing the same including tightening of nuts and bolts.(g) Checking oil in FLP thrustors checking any leakage any filling with new oil.(h) Checkinh terminal connection of all HT motion of three phase FLP electric motor and tightening properly including replacing burnt out/over heated cable ends if any.(I) Checking hook block and greasing the bearings. |
| 5 | (D) ELECTRICALS(a) Checking and tightening all electric connection.(b) Checking the contactors /relays etc for overheating or flashhing.(c) Cleaning off all connection and control cables.(d) Properly bunching the loose control cables.(e) Checking functioning of cable carriers.(f) Checking the connections and serviceability of VVVF drives for smooth working. Please Enable Macros to View BoQ information |
| 6 | (D) ELECTRICALS(a) Checking and tightening all electric connection.(b) Checking the contactors /relays etc for overheating or flashhing.(c) Cleaning off all connection and control cables.(d) Properly bunching the loose control cables.(e) Checking functioning of cable carriers.(f) Checking the connections and serviceability of VVVF drives for smooth working. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender