Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58073298

Tender For Repair/Maintenance Of Summer Appliances, Window / Split Acs, Cold Storage, Package Plant With Allied Works Under Ge(S) Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
45 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
16 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Summer Appliances, Window / Split Acs, Cold Storage, Package Plant With Allied Works Under Ge(S) Tezpur

BOQ

Name of Work:- Repair/Maintenance of Summer Appliances, window / split Acs, cold storage, package plant with allied works under GE(S) Tezpur
Sl. No. Item Description
1Supply and installation of AC Compressor of capacity 3 Phase, 5 TR package unit, Model No. ZR-72 , including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed.
2Supply and installation of AC Compressor of capacity 3 Phase, 3 TR package unit, including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed.
3Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
4Supply and fixing sub zero compressor Timer for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
5Supply and fixing in repair HP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed.
6Supply and fixing in repair LP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed.
7Supply and fixing in repair blower fan motor (indoor unit) for 5 ton compressor as per site complete all as specified and directed.
8Supply and fixing in repair fan motor (outdoor unit) for 5 ton compressor as per site complete all as specified and directed.
9Supply and fixing in repair blower fan motor (indoor unit) for 3 ton compressor as per site complete all as specified and directed.
10Supply and fixing in repair fan motor (outdoor unit) for 3 ton compressor as per site complete all as specified and directed.
11Supply and fixing in repair temperature gauge for both cold room and cool room in showing centrigrade and ferenheit complete all as specified and directed.
12Supply and charging of refrigerent gas R-22 for cold storage plant complete all as specified and directed.
13Supply and fixing in repair blower fan blade (indoor unit) for 5 ton compressor complete all as specified and directed.
14Supply and fixing in repair three pole contactor MNX 18 suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
15Supply and fixing in repair Conactor assay suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
16Supply and fixing in repair drier filter of 5/8 inch type for cold storage plant complete all as specified and directed.
17Supply and fix in repair of four core cable copper conductor PVC insulated multistranded sheathed 1100 Volt grade 2.5 sqmm complete all as specified & directed.
18S&F Indoor unit condensor coil suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
19S&F Outdoor unit condensor coil suitable for 3 phase 5 TR package type AC capacity including making necessary connection complete all as specified and directed.
20S&F Indoor unit condensor coil suitable for 3 phase 3 TR package type AC capacity including making necessary connection complete all as specified and directed.
21S&F Outdoor unit condensor coil suitable for 3 phase 3 TR package type AC capacity including making necessary connection complete all as specified and directed.
22M&L for carrying out pressure test of the 3 phase 3/5 TR package type AC system connection to open type /sealed compressor unit and checking for leakage with filling nitrogen gas to required pressure rectify leakage and again testing to the entire satisfaction of GE complete all as specified and directed.
23Supply and fixing in repair nitrile insulation 7/8' (11x5 mtr) for insluating refrigerent flow copper tube complete all as specified and directed.
24Supply and fix in repair of rubber mounting pad for package AC outdoor unit complete all as specified and directed.
25Supply and fixing in repair 440 Volts MCCB , Four pole ,\\"C\\" curve , 125 Amps 25 KA breaking capacity complete all as specified and directed.
26Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-chargend
27Air ConditionerM&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TR for replacing to u/s spare parts / carrying out neccessary repairing works/ shifting location/ gas re-filling etc in any make /model all as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required) at same after repairing work complete all specified and as directed. Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same. (ii) All spare parts shall be measured and paid separately under relevant items.
28M&L for overhauling, dusting, cleaning by compressed air, washing using causting soda mixed with water after scraping to old paint coat to be preparing the surface for re-painting to air condioner in any type /make/ model/ cap/ etc all as site using heat resistive/ synthetic enamel paint by paint spray gun in two coats over one coat of red oxide primer and indication marking by diffirent colour in standard size of letter complete all specified and as directed . Note :- (i) All spare parts required to servicing shall be measured and paid separetly under relevant item.
29Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22 in original to window or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and as directed. Note : Grade of refrigerant shall be supplied as per model /make requirement in original.
30Labour for re-fixing/installation/ connecting/ testing and commissioning of repaired air conditioner under above item in original postion all as same as per exsiting incl making electric / air connections with other site required work for serviceablity complete all as specified and as directed.
31Supply only rotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed.
32All as above item No 31 but rotary DC compressor unit for invertor split type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed.
33All as above item No 31 but reciprocating / rotary AC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
34All as above item No 31 but reciprocating / rotary AC compressor unit for split type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed.
35All as above item No 31 but Starting/Running Capatior for Existing model of split/ window AC complete all as specified and directed.
36All as above item No 31 but condenser unit for window type AC complete all as specified and directed.
37All as above item No 31 but indoor unit blower fan motor for split type cap 1.5 TR. complete all as specified and directed.
38All as above item No 31 but out door unit fan motor for split type cap 1.5 TR complete all as specified and directed. complete all as specified and directed.
39All as above item No 31 but indoor unit blower motor for split type cap 2 TR.complete all as specified and directed.
40All as above item No 31 but out door unit fan motor for split type cap 2 TR complete all as specified and directed.
41All as above item No 31 but blower fan motor for window AC cap 1.5/2 TR complete all as specified and directed.
42All as above item No 31 but PCB outdoor for split type AC cap 1.5/ 2 TR. as per site requirement. complete all as specified and directed.
43All as above item No 31 but PCB indoor for split type AC cap 1.5/ 2 TR with remote Control.complete all as specified and directed.
44All as above item No 31 but PCB for window type AC cap 1.5/ 2 TR.complete all as specified and directed.
45All as above item No 31 but DC stapping motor.complete all as specified and directed.
46All as above item No 31 but thermostate assembly.complete all as specified and directed.
47All as above item No 31 but indoor condensestion unit for split type 1.5 TR AC complete all as specified and directed.
48All as above item No 31 but outdoor condensestion unit for split type 1.5 TR AC.complete all as specified and directed.
49All as above item No 31 but indoor condensestion unit for split type 2 TR AC.complete all as specified and directed.
50All as above item No 31 but outdoor condensestion unit for split type 2 TR AC.complete all as specified and directed.
51All as above item No 31 but relay for AC for window /split type cap 1.5/ 2 TR.complete all as specified and directed.
52All as above item No 31 but Selector switch complete all as specified and directed.
53All as above item No 31 but front panel grill. complete all as specified and directed.
54All as above item No 31 but Remote control suitable for as site unit. complete all as specified and directed.
55All as above item No 31 but automatic sensor card.complete all as specified and directed.
56All as above item No 31 Capacitor for Fan motor.complete all as specified and directed.
57Supply only of Air filter for split/ window type AC.complete all as specified and directed.
58Supply only of swing motor for indoor unit of split/window AC.complete all as specified and directed.
59Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil.complete all as specified and directed.
60Supply only for blades of model of existing/ suitable model of window/ split type (outdoor Unit) of capacity up to 2 TR complete all as specified and directed.
61M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirement for air conditioner in all make/type/ model /cap upto 2 TR etc for making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting complete all as specified and directed. .
62NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073298
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Summer Appliances, Window / Split Acs, Cold Storage, Package Plant With Allied Works Under Ge(S) Tezpur
Basic Detail
Tender No 8204
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 15 Oct 2026
Submission Date 04 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
1958e9f6-9434-4ab2-ba69-b5b2a42bfe88.html
Addldocus.pdf
BOQ_890740.xls
Tenderdocus.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

1958e9f6-9434-4ab2-ba69-b5b2a42bfe88.html

pdf

Addldocus.pdf

xls

BOQ_890740.xls

pdf

Tenderdocus.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender