Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #58073295

Tender For Repair/Maint Of Summer Appliance And Repairs To Ci/Gi/Di Pipe Line At North Of Railway Line And At Af Stn Missamari Under Ge Missamari

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Oct 2026
1 days left
EMD
88500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Summer Appliance And Repairs To Ci/Gi/Di Pipe Line At North Of Railway Line And At Af Stn Missamari Under Ge Missamari

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Oct-2026 BOQ CORRIGENDUM BOQ 29-Oct-2026

BOQ

Name of Work:- REPAIR/MAINT OF SUMMER APPLIANCE AND REPAIRS TO CI/GI/DI PIPE LINE AT NORTH OF RAILWAY LINE AND AT AF STN MISSAMARI UNDER GE MISSAMARI
Sl. No. Item Description
1Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
2Repairs/Servicing Air Conditioner 2.0 Ton Capacity, Window type at Site of any Make and any type by replacing unserviceable Parts (like Compressor and other Minor Parts viz Capilary Tube, Machine Screws, Washer, Rubber Bush, etc) from the Machine including Charging of Refrigerant Gas after vacuuming and leak testing, brazing the suction/discharge tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect, checking of Electrical Circuit of machine and repair where necessary by replacing proper size PVC insulated Wires and cleaning of AC using air blower as directed, commissioning & Testing, complete all as specified and directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
3Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
4S&F in repair, starting relay for 1.5 TR compressor all as specified and directed.
5S&F in repair, starting relay for 2 TR compressor all as specified and directed.
6S&F in repair, over load protector for 1.5 TR compressor all as specified and directed.
7S&F in repair, over load protector for 2TR compressor all as specified and directed.
8S&F in repair, Thermostate switch for 1.5 TR split/window type AC all as specified and directed.
9S&F in repair, Thermostate switch for 2 TR split/Window type AC all as specified and directed.
10S&F in repair, suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
11S&F in repair, discharge copper pipe line heavy duty 1/4\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
12S&F in repair, discharge copper pipe line heavy duty 5/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
13S&F in repair, discharge copper pipe line heavy duty 3/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
14S&F in repair, PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
15S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specifed and directed.
16S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specifed and directed.
17S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specifed and directed.
18S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specifed and directed.
19S&F in repair, of running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
20S&F in repair, of running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed.
21S&F in repair, of running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed.
22S&F in repair, Running capacitor 6 mfd metal body pin type complete all as specified and directed
23S&F in repair, Running capacitor 4 mfd metal body pin type complete all as specified and directed
24Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, complete all as specified and directed.
25Dismantling of defective condensing unit of split type AC of 2.0 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, complete all as specified and directed.
26Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and S&F blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star complete all as specified and directed.
27Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and S&F blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star complete all as specified and directed.
28Dismantling of burnt condensor motor of 1.5 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star complete all as specified and directed.
29Dismantling of burnt condensor motor of 2 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all as specified and directed.
30Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed.
31Dismantling of burnt swing motor of 2 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed.
32Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quatity complete all as specified and directed.
33Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quatity complete all as specified and directed.
34Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed.
35Supply and fixed in repairs of suction valve size 1/2\\" complete all as specified and directed .
36Supply and fixed in repairs of discharge valve size 1/4\\" complete all as specified and directed.
37Supply and fixed in repairs of suction valve size 5/8\\" complete all as specified and directed .
38Supply and fixed in repairs of discharge valve size 3/8\\" complete all as specified and directed.
39Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), including testing on completion complete all as directed
40Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity),including testing on completion complete all as directed
41M&L for carrying out pressure leak test of split ACs 1.5 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
42M&L for carrying out pressure leak test of split ACs 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
43M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
44Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
45Dismantling of defective worn out wiring of indoor unit of split AC of capacity 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
46S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
47Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed alongwith fixing arrangement with nuts and bolts complete all as directed (Note :- Excess requirement of refrigerant pipe line, AC outdoor metalic stand ,electric connection cable , drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
48Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
49S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton rotary compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all as specified and as directed.Note :- Charging of gas refrigerant will be paid and measured separately
50All as per item No 49 here in before but 2 TR capacity rotary compressor
51Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item )
52Taking down indoor unit of 2.0 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item )
53S&F in replacement of AC Outdoor metallic stand for fixing out door unit complete all as specified and as directed.
54S&F Compressor sealed unit for Window type Air Conditioner of capacity 1.5 ton rotary compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all as specified and as directed.Note :- Charging of gas refrigerant will be paid and measured separately
55Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required ( exc. Half Brick but not exc. one brick thick Walls) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed.
56S&F Timer for AC duly setting as per PCB configuration and connected wiring complete all as specified and as directed.
57Supply and fix power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed:-
58Supply and fix remote control hand set for 2.0TR capacity split AC complete all as specified and as directed.
59Supply and fix remote control hand set for 1.5TR capacity split AC complete all as specified and as directed.
60Supply and fix remote control hand set for 1.5TR capacity Window type AC complete all as specified and as directed.
61Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed
62Supply & Fix PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types complete all as specified and directed
63Supply & Fix Bimetal 2 wire/3wire /4 wire complete all as specified and directed
64Supply & Fix Forst free fan motor SP 230 volts complete all as specified and directed
65Supply & Fix Sensor for cooling coil complete all as specified and directed
66Supply & Fix PCB timer of refrigerator 180-310ltrs required as per site complete all as specified and directed
67Supply & Fix Condenser coil for 165 to 200 Ltrs complete all as specified and directed
68Supply & Fix Condenser coil for 250 to 310 Ltrs complete all as specified and directed
69S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all as specified and directed
70Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Regrigerator of Capaicty 165/180 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely
71Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capaicty 285/310 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely
72Dismantling of defective water cooler storage type of 40/80/120/150 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed.
73Supply & Fix PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs complete all as specified and directed
74Supply & Fix Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 ltrs complete all as specified and directed
75Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 /120/150ltrs/hrs complete all as specified and directed
76Supply & Fix new compressor suitable for 40/80 ltr/hrs storage capacity including testing complete all as specified and directedNote:- (Recharging of gas will be measured and paid separately).
77Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make or type complete all as specified and directed.
78Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed
79Supply & Fix new deep freedge compressor for storage capacity of 200 ltrs deep freezer including testing all as specified and directed . Note:-(Recharging of gas will be measured and paid separately).
80Supply & Fix Relay for deep freezer of any size/capacity complete all as specified and directed
81Supply & Fix Overload for compressor of deep freezer of any size/capacity complete all as specified and directed
82Supply & Fix Thermostate for deep freezer complete al as specified and directed
83Supply & Fix 4\\" condenser fan motor 240 volt complete all as specified and directed
84Opening carefully of Voltage stabiliser of capacity 5 KVA, removing the old U/S, rewinding of the current transformer with stranded super enamelled copper winding wire as per existing size/gauge repairing the same with minor parts as required to make it functional complete all as specified and directed
85All as per item No- 187 above but Voltage stabiliser of capacity 3KVA
86All as per item No- 187 above but Voltage stabiliser of capacity 2.0 KVA
87All as per item No- 187 above but Voltage stabiliser of capacity 1.0 KVA
88S&F ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed.
89S&F ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed.
90S&F ceiling fan capacitor 4.0 mfd as per site requirement heavy duty with metal body including removal old existing unsv one complete all as specified and directed.
91Disconnecting and taking down ceiling Fan/Wall mounted/Exhaust Fan/Air Circulator of any Sweep by Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts,etc. Overhauling, Lubricating with approved Lubricants, re-assembling including, re-fixing in Original Positon checking smooth functioning and including electrically connected with Flexible Wire multi-stranded Copper conductor cable of size 23/0.0076 from ceiling rose to fan cleaning all dust etc after repair duly painted two coats as per existing colour over a coat s as per existing colour over a coat of primer and testing complete all as specified and as directed.
92M&L rewinding ceiling Fan 1200/1400mm Sweep of any Make and type with super enamelled copper winding wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/wornout Points for statisfactory running and testing, complete all as specified and directed.
93S&F Ball bearing No 6201 (as approved) suitable for ceiling fans complete all as specified and directed.
94S&F Ball Gun Metal Bush (as approved) suitable for ceiling fans 1200/1400 mm sweep complete all as specified and directed.
95M&L rewinding Exhaust Fan 300mm Sweep of any Make and type with super enamelled copper winding wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/wornout Points for statisfactory running and testing, complete all as specified and directed.
96S&F Ball bearing (as approved) suitable for Exhaust fans 300 mm sweep complete all as specified and directed.
97S&F Ball Gun Metal Bush (as approved) suitable for Exhaust fans 300 mm sweep complete all as specified and directed.
98M&L rewinding Exhaust Fan 380/450mm Sweep of any Make and type with super enamelled copper winding wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/wornout Points for statisfactory running and testing, complete all as specified and directed.
99S&F Ball bearing (as approved) suitable for Exhaust fans 380/450 mm sweep complete all as specified and directed.
100S&F Ball Gun Metal Bush (as approved) suitable for Exhaust fans 380/450 mm sweep complete all as specified and directed.
101M&L rewinding Air Circulator 450/600mm Sweep of any Make and type with super enamelled copper winding wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/wornout Points for statisfactory running and testing, complete all as specified and directed.
102S&F Ball bearing (as approved) suitable for Air Circulators complete all as specified and directed.
103S&F Ball Gun Metal Bush (as approved) suitable for Air Corculators 450/600 mm sweep complete all as specified and directed.
104S&F in replacement of unserviecalbe Armature core of Ceiling Fan 1200MM sweep of model as per site requirement complete all as specified and directed.
105S&F in replacement of unserviecalbe Armature core of Eahaust Fan 300MM sweep of model as per site requirement complete all as specified and directed.
106S&F in replacement of unserviecalbe Armature core of Heavy Duty Eahaust Fan 380mm to 450 mm sweep of wall mounted fan of model as per site requirement complete all as specified and directed.
107S&F in replacement of PVC fan blade of exhaust fan of 250mm sweep as per existing complete all as specified and directed.
108S&F in replacement of blower motor of PVC sturdy plastic fan of 250mm sweep as per existing complete all as specified and directed.
109S&F of PCB of BLDC ceiling fan 1200mm as per existing make complete all as specified and directed.
110S&F of remote of BLDC ceiling fan as per existing make complete all as specified and directed.
111S&F of CI fan hook any size any type required as per site in ceiling of any type complete all as specified and directed.
112S&F 1100 volts grade PVC insulated stranded Flexible Copper conductor twin core of 1.0 Sqmm complete all as specified and directed.
113S&F in replacement of clamps for hanging of ceiling fans with rubber nut bolts complete all as specified and directed.
114Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for taking out/laying of CI/DI/GI pipelines etc, forming bottom of trenches to the required level and gradient and getting out in soft/loose soil complete all as specified and as directed.
115Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
116Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
117Taking up or down GI steel tubing of 20mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
118Taking up or down GI steel tubing of 25/32mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
119Taking up or down GI steel tubing of 40mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
120Taking up or down GI steel tubing of 50mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
121Taking up or down GI steel tubing of 80mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
122Taking up or down GI steel tubing of 100mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
123Taking up or down GI steel tubing of 150mm bore including connections from trenches/walls/floors etc complete all as specified and as directed.
124Taking up cast iron water mains 80mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
125Taking up cast iron water mains 100mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
126Taking up cast iron water mains 150mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
127Taking up cast iron water mains 200mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
128Taking up cast iron water mains 250mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
129Taking up cast iron water mains 300mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.Note:- Serviceable pipe and Lead shall be kept in safe custody for reuse
130M&L 90mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
131M&L 63mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
132M&L 50mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
133M&L 40mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
134M&L 32mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
135M&L 25mm outer dia,3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
136Fixing only 20mm bore GI tubing with new fittings fixed to to walls and ceilings or laying in floors and making good to walls complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 4 here-in-before
137Fixing only 25mm bore GI tubing with new fittings fixed to to walls and ceilings or laying in floors and making good to walls complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 5 here-in-before
138Supply, Laying and testing Tubes, 'Medium Grade' galvanised 40mm bore with all fittings, laid in trenches,complete all as specified and directed.
139Supply, Laying and testing Tubes, 'Medium Grade' galvanised 50mm bore with all fittings, laid in trenches,complete all as specified and directed.
140Supply, Laying and testing Tubes, 'Medium Grade' galvanised 80mm bore with all fittings, laid in trenches,complete all as specified and directed.
141Supply, Laying and testing Tubes, 'Medium Grade' galvanised 100mm bore with all fittings, laid in trenches,complete all as specified and directed.
142Supply, Laying and testing Tubes, 'Medium Grade' galvanised 150mm bore with all fittings, laid in trenches,complete all as specified and directed.
143Supply only GI Flange 80mm bore complete all as specified and as directed.Note:- Mild steel nuts biolts, washers, rubber gasket etc as required shall be deemed to included in the UNIT RATE QUOTED
144Supply only GI Flange 100mm bore complete all as specified and as directed.Note:- Mild steel nuts biolts, washers, rubber gasket etc as required shall be deemed to included in the UNIT RATE QUOTED
145Supply only GI Flange 150mm bore complete all as specified and as directed.Note:- Mild steel nuts biolts, washers, rubber gasket etc as required shall be deemed to included in the UNIT RATE QUOTED
146Supply only Rubber/EPDM gasket 4mm thick complete all as specified and as directed
147S&F in repair, 63mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
148S&F in repair, 50mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
149S&F in repair, 40mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
150S&F in repair, 32mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
151S&F in repair, 25mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed.
152Making connection of PP-R distribution branch with PP-R main of size 16mm to 40mm outer dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed
153Making connection of PP-R distribution branch with PP-R main of size 50mm to 90mm outer dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed
154S&F in repair, 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
155S&F in repair, 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
156S&F in repair, 32mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
157S&F in repair, 40mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
158S&F in repair, 50mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
159Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 300mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
160Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 250mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
161Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 200mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
162Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 150mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
163Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 100mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
164Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 80mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. Note- Excavation,DI Specials shall be measured and paid separately .
165S&F DI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch. \\"Y\\" junction, double branch, cross collars, caps and plugs for Pipe upto 300mm bore complete all as specified and as directed.
166M&L Cast Iron Sluice Valve 80 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
167M&L Cast Iron Sluice Valve 100 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
168M&L Cast Iron Sluice Valve 150 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
169M&L Cast Iron Sluice Valve 200 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
170M&L Cast Iron Sluice Valve 250 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
171M&L Cast Iron Sluice Valve 300 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed.
172Supply and Fixing cast iron body and brass gate heavy duty non return valve ( NRV) 80 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceablenon return valve ( NRV), complete all as specified and as directed.
173Supply and Fixing cast iron body and brass gate heavy duty non return valve ( NRV) 100 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceablenon return valve ( NRV), complete all as specified and as directed.
174Supply and Fixing cast iron body and brass gate heavy duty non return valve ( NRV) 150 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceablenon return valve ( NRV), complete all as specified and as directed.
175Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 80 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
176Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 100 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
177Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 150 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
178Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 200 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
179Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 250 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
180Supply, laying and testing DI socket leak repairing clamp complete with nuts and EPDM gasket having bore /dia 300 mm for repair of leakage/ break down of DI pipes socket complete all as specified and as directed.
181Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 80mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
182Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 100mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
183Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 150mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
184Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 200mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
185Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 250mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
186Supply, laying and testing MS patch clamp or leak repairing clamp complete with accesories having bore/ dia 300mm for repair of leakage/ break down of DI pipes complete all as specified and as directed
187M&L Burning out lead joint in position,80mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
188M&L Burning out lead joint in position,100mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
189M&L Burning out lead joint in position,150mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
190M&L Burning out lead joint in position,200mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
191M&L Burning out lead joint in position,250mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
192M&L Burning out lead joint in position,300mm bore including recovering old lead, complete all as directed.Note- Excavation,wherever required shall be measured and paid separately under appropiate item.
193M&L run lead joints for pipes and fittings (spigot and socket ends) 80 mm bore (dia) and testing complete all as specified and as directed.
194M&L run lead joints for pipes and fittings (spigot and socket ends) 100 mm bore (dia) and testing complete all as specified and as directed.
195M&L run lead joints for pipes and fittings (spigot and socket ends) 150 mm bore (dia) and testing complete all as specified and as directed.
196M&L run lead joints for pipes and fittings (spigot and socket ends) 200 mm bore (dia) and testing complete all as specified and as directed.
197M&L run lead joints for pipes and fittings (spigot and socket ends) 250 mm bore (dia) and testing complete all as specified and as directed.
198M&L run lead joints for pipes and fittings (spigot and socket ends) 300 mm bore (dia) and testing complete all as specified and as directed.
199Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 80mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
200Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 100mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
201Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 150mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
202Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 200mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
203Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 250mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
204Labour only Run Lead Joint for Pipes and Fittings (Spigot and Socket Ends) 300mm bore (dia) (Serviceable Lead obtained from burning of joints) and Testing, complete all as specified and as directed. NOTE : Serviceable lead retrived from burning out of lead joints to be reused.
205M&L Construction Brick Masonry Valve Pit of size 900x900x900 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and as directed.
206M&L Construction Brick Masonry Valve Pit of size 750x750x900 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and as directed.
207M&L Construction Brick Masonry Valve Pit of size 600x600x600 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and as directed.
208S&F in repair Rolled mild steel as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410W(Gde 250,Quality A) for erection of path all around the water tank at 40 to 60 Feet height MS staging including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified and directed.
209Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 150 mm bore (dia) for passing of pipes, complete all as specified and as directed.Note:- GI pipe will be measured and paid seperately under appropiate item
210M&L fabrication of MS clamp of size 50x4 mm and min total length 1.0 mtr using 4 nos nut, bolt and washers for supporting lead joints for CI pipes of dia 80 mm to 300 mm including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified and directed.
211S&F in repair, Rolled mild steel as in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe-410W(Gde 250,Quality A) for erection of path all around the water tank at 40 to 60 Feet height MS staging including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified and directed.
212M&L S. G. Iron Butterfly Valve 100 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, with ss disc lever operated , nitrile/EPDM rubber lining with all necessary fixing Arrangements such as and testing including taking down unserviceable butterfly Valve, complete all as specified and as directed.
213M&L S. G. Iron Butterfly Valve 80 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, with ss disc lever operated , nitrile/EPDM rubber lining with all necessary fixing Arrangements such as and testing including taking down unserviceable butterfly Valve, complete all as specified and as directed.
214Supply and Fixing cast iron body Air release valve 150 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceableair release valves, complete all as specified and as directed.
215Supply and Fixing cast iron body Air release valve 200 mm bore with flanged end all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceableair release valves, complete all as specified and as directed.
216M&L PCC Type B2 1:2:4(40mm graded aggregate) as in foundations/filling in mass concrete including necessary formwork as required, complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073295
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Summer Appliance And Repairs To Ci/Gi/Di Pipe Line At North Of Railway Line And At Af Stn Missamari Under Ge Missamari
Basic Detail
Tender No 8702/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 21 Oct 2026
Submission Date 29 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 88500
Exemption Available
Document List
789dd95d-a0ac-4c58-bdde-afb27f58f23e.html
BOQ_890747.xls
Tender8702.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

789dd95d-a0ac-4c58-bdde-afb27f58f23e.html

xls

BOQ_890747.xls

rar

Tender8702.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender