Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58073285

Tender For Provn Of Dsa At Mgr And Environmental Controllers And Dehumidifier Alongwith Electric Panel And Wiring Against Existing Deficiency For Critical Electrical Equipments Of Heron Mk-Ii Rpa Of Rfa Flt Under Ge Missamari

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Oct 2026
3 days left
EMD
80926
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Dsa At Mgr And Environmental Controllers And Dehumidifier Alongwith Electric Panel And Wiring Against Existing Deficiency For Critical Electrical Equipments Of Heron Mk-Ii Rpa Of Rfa Flt Under Ge Missamari

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Oct-2026 BOQ CORRIGENDUM BOQ 29-Oct-2026

BOQ

Name of Work:- PROVN OF DSA AT MGR AND ENVIRONMENTAL CONTROLLERS AND DEHUMIDIFIER ALONGWITH ELECTRIC PANEL AND WIRING AGAINST EXISTING DEFICIENCY FOR CRITICAL ELECTRICAL EQUIPMENTS OF HERON MK-II RPA OF RFA FLT UNDER GE MISSAMARI
Sl. No. Item Description
1Excavation in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Foundation, laying of cable etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed.
2Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed.
3Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
4M&L for hardcore of gauge n.exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed.
5M&l For Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
6M&L Cement concrete in foundations, filling and mass concreteType D2 1:4:8 (40 mm graded Stone aggregate), complete all as specified and directed
7M&L for RCC design mix M25 using 20 mm graded aggrgate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass co, complete all as specified and directed.
8M&L RCC design mix M25 using 20 mm graded aggregate for Columns, pillars, piers, posts and struts complete all as specified and directed.
9M&L RCC design mix M25 using 20 mm graded aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span complete ,complete all as specified and directed
10M&L RCC design mix M25 using 20 mm graded aggregate for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
11M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed.
12M&L Formwork to sides of pillars,posts, struts, piers, columns and stanchions. Square,rectangular or polygonal, roughed finished surfaces, complete all as specified and as directed.
13M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc flat, rought finished surfaces of concerete complete all as specified and directed.
14M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat, rought finished surfaces of concerete complete all as specified and directed.
15Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
16M&L TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
17All as per item no 16 but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
18M&L brick work with sub class 'B' bricks, old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
19M&L Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
20M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth, without using extra cement, complete all as specified and directed.
21M&L rendering 20mm thick with cement mortar 1:4 on fair faces of brick work in two layers (10mm and 10mm) sperately mixed with and including water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and fair complete all as specified and directed.
22Supply only Integral water proofing compound complete all as specified and directed.
23M&L preperation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
24M&L for preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specificationover new surface over 1 mm thick acrylic wall care putty,complete all as specified and directed.
25M&L preperation of new surfaces of ceilings and applying two coat of white wash,complete all as specified and as directed
26M&L 100mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as sub base of floor finished even and fair complete all as specified and directed.
27M&L 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed.
28M&L Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed.
29M&LRendering 5mm thick in ceiling surface cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed.
30Supply and fixing factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall dimension of 2.3± 0.2 mm and single glazing bead / double glazing bead of appropraite dimension (Area dooe upto 2.00 sqmm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension., EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle of each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fastners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent ober backer rod of required size and of appropriate size and of approved quality incl glass complete all as specified and directed by Engineer-in-Charge.Note: for uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
31S&F factory made uPVC white colour sliding window two track made of extruded profiles with wall thickness of 2.3( ± 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 62 mm) sash (42mm x 67mm), sliding interlock (one vertical length 1 each shutter) (45.5 mm x 28mm). Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. Making arrangement for fixing of hardware. EPDM gasket 1.2 ± 0.2 mm thick galvanised steel frame (30mm x 21.5mm), sash (30 mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware [touch lock of zinc allowed (white powder coated), steel roller system including 5 mm thick glazing with selected quality glass, aluminium track bottom rail for two track sliding frame wool pine for sliding sash and interlock]Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories. Net opening will be measured for payment purposeArea not exceeding 2.00 sqm each
32M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification complete all as specified and as directed:-(i) Applying one coat of bituminous primer @0.40 Ltr/Sqm.(ii) Laying of 3mm thick APP based polymeric membrane of approved manufacturer with weight not less than 3.50 Kg/Sqm, reinforced with non-woven polyster fabric weight not less than 160 gm/Sqm. Polymeric membrane shall be taken to a height of 30 cm(minimum) and then inserted inside the groove of parapet wall and wall shall be finished by a membrane plastering.(iii) Two coats of solar reflective bituminous aluminium paint of approved approved based to provided over APP membrane as per manufaturer instruction. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.
33M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. Please Enable Macros to View BoQ information
34M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073285
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Dsa At Mgr And Environmental Controllers And Dehumidifier Alongwith Electric Panel And Wiring Against Existing Deficiency For Critical Electrical Equipments Of Heron Mk-Ii Rpa Of Rfa Flt Under Ge Missamari
Basic Detail
Tender No 8745/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 21 Oct 2026
Submission Date 29 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80926
Exemption Available
Document List
05aca94b-3b9c-4558-bdf0-98cf71681773.html
BOQ_890743.xls
Tender8745.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

05aca94b-3b9c-4558-bdf0-98cf71681773.html

xls

BOQ_890743.xls

rar

Tender8745.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender