Tender for Addition / Alteration Of Icv Abhay Workshop (Building No. P-264) Specialist Garage P-201 & Tank Garage P-202 At Vrde, Ahmednagar

BOQ

Name of Work:- ADDITION / ALTERATION OF ICV ABHAY WORKSHOP (BUILDING No. P-264) SPECIALIST GARAGE P-201 & TANK GARAGE P-202 AT VRDE, AHMEDNAGAR
Sl. No. Item Description
1=B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: ADDITION / ALTERATION OF ICV ABHAY WORKSHOP (BUILDING No. P-264) SPECIALIST GARAGE P-201 & TANK GARAGE P-202 AT VRDE, AHMEDNAGAR Contract No: CERD/GIR/TOKEN/40 OF 2026-2027 Bidder Name : PRICE SCHEDULE( This BoQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words
2Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sq.metres and below complete all as specified and directed.
3Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area beyond 3 sq.metres complete all as specified and directed.
4Providing and fixing frame size 45 x 70mm factory made single extruded WPC (Wood Polymer Composite) solid door / window / clerestory windows & other frames / chowkhat comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of
558 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position with M.S hold fast / lugs / SS dash fasteners of required dia and length complete all as specified and directed.
6Providing and fixing frame size 65 x 125mm factory made single extruded WPC (Wood Polymer Composite) solid door / window / clerestory windows & other frames / chowkhat comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum
7compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position with M.S hold fast / lugs / SS dash fasteners of required dia and length complete all as specified and directed.
8Providing and fixing factory made 30mm thick single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture
9proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directed.
10S&F, rolling shutters 80 x 1.25mm M.S. laths with 1.25mm thick top cover of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 - Part 1 and M.S. top cover of required thickness for rolling shutters. (Electrically operated rolling shutter).
11Supply & erect motor capacity 800 kgs over head type for rolling shutter of 550 W complete all as specified and directed.
12Dismantling of any type steel rolling shutters any description complete all as specified and directed.
13Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10sqm on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m in all kinds of soil complete all as specified and directed.
14Hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
15M&L for 75mm thick cement concrete type C2, 1:3:6 (40mm graded aggregate) complete all as specified and directed.
16M&L for 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) internal plaster complete all as specified and directed.
17Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
18Complete removal of exiting surfaces and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New / old work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre complete all as specified and directed.
19M&L for finishing walls with acrylic smooth exterior paint of required shade, new / old work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) complete all as specified and directed.
20M&L for wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour one coat complete all as specified and directed.
21Painting steel work with deluxe multi surface paint to give an even shade two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture complete all as specified and directed.
22Painting on wooden surface (new/old) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade complete all as specified and directed.
23Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead complete all as specified and directed.
24M&L for floor treatment in following method.Surface preparation: Providing and cleaning all floor surface to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants. Mechanical surface profiling to be provided grinding.
25Priming: Providing and applying Apcoflor HFP 120/Apcoflor HFP 130, solvent free epoxy primer 150-200 gms/SqM in two coats using a brush or short / medium pile roller at a time gap of 8 hrs by ensuring a uniform coating is achieved and compensated the differences in surface porosity, allowing second coat to dry for 24 Hrs, as per manufacturer's specification.All cracks and construction joints should be either filled with epoxyputty or mortar.
26Epoxy screed: Providing and installing, Apcoflor LSC3 XL high performance, epoxy resin flooring screed by mixing all 3 component susing heavy duty slow speed drilling machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel at 4.5mm thickness at consumption of 7.4 - 7.6 Kg/SqM. Gently rolling the surface of Apcoflor LSC3 XL using bubble roller for uniform spreading followed by spike roller to remove the entrapped air, as per manufacturer's specification.
27Epoxy Top Coat: Providing and installing, Apcoflor SL1TC high performance, electrostatic dissipative epoxy resin flooring system having excellent compressive strength, flexibility and tensile strength by mixing all components including pigment, using heavy duty slow speed drilling machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel at 1.5mm thickness at consumption of 3 Kg/SqM. Gently rolling the surface of Apcoflor SL1TC using bubble roller for uniform spreading followed
28by spike roller to remove the entrapped air, as per manufacturer's specification.Note: Equivalent construction chemical of other specification makes can also be used.
29Providing and laying matt finished vitrified tile of size exceeding 0.18 sqm but not exceeding 0.36 sqm and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments complete all as specified and directed.
30Providing and laying 600 x 600mm vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make in all colours and shades over and including on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments complete all as specified and directed.
31Providing and fixing 1st quality ceramic glazed wall tiles size 300 x 450mm / 450 x 600mm conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over and including 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
32Providing & fixing long pattern W.C pan of size 580 x 440mm white vitreous china water closet squatting pan (Indian type) alongwith 'S' or 'P' trap including dismantling of old WC seat and 'S' or 'P' trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba complete all as specified and directed.
33Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white PVC flushing cistern & PVC flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : with plastic seat cover including two way angle valve with CP health faucet complete all as specified and directed.
34Dismantling of flushing cistern of all types (C.I. / PVC / Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead complete all as specified and directed.
35Providing and fixing P.V.C. low level flushing cistern with manually controlled device (dual type) conforming to IS:7231, with all fittings and fixtures complete 10 litre (full flush) capacity-white complete all as specified and directed.
36Providing and fixing white vitreous china wash basin including making all connections, flat back wash basin of size 630 x 450mm complete all as specified and directed.
37Providing and fixing chromium plated bib cock of approved quality and colour 15mm nominal bore, 90mm long, weighing not less than 93 gms complete all as specified and directed.
38Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore complete all as specified and directed.
39Providing and fixing uplasticised PVC connection pipe with brass unions 15mm bore 45cm long complete all as specified and directed.
40Providing and fixing CP waste coupling for wash basin and sink of approved quality and colour waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60 gms complete all as specified and directed.
41Providing and fixing chromium plated pillar cock of approved quality and colour 15mm nominal bore, 125mm long foam flow, weighing not less than 120 gms complete all as specified and directed.
42Providing and fixing stone slab with table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite stone of approved shade complete all as specified and directed.
43Providing and fixing vitreous China half stall urinals with standerd flush pipe and CP brass spreader with brass union complete all as specified and directed.
44Dismantling 15 to 40mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed.
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 15mm nominal dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25mm nominal dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 40mm nominal dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
48Providing and fixing CVPC 25mm nominal bore gate valve of approved quality complete all as specified and directed.
49Providing and fixing CVPC 40mm nominal bore gate valve of approved quality complete all as specified and directed.
50Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with PVC float valve with fittings and the base support for tank capacity 1000 ltr complete all as specified and directed.
51Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with PVC float valve with fittings and the base support for tank capacity 500 ltr complete all as specified and directed.
52Providing and fixing S.S towel ring trapezoidal shape 215mm long, 200mm wide with minimum distance of 37mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms complete all as specified and directed.
53600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
54Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 & IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc., aluminium sections shall be smooth, rust free,
55straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws complete all as specified and directed.
56Power coated aluminium window and ventilator shutters sliding type, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium including fittings complete all as specified and directed.
57Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions with EPDM rubber / neoprene gasket complete as per the architectural drawings and the directions of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) : with float glass panes of 4mm thickness (weight not less than 10kg/sqm) complete all as specified and directed.
58Providing and fixing fly proof galvanized S.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63mm with 12mm mild steel U beading complete all as specified and directed.
59M&L for cement concrete work in pavement / hardstanding of flexural strength 40kg/per Sq.cm in field using 400 kgs of cement per cubic metre, thickness of concrete 25cm or less complete all as specified and directed.
60Providing and fixing ISI marked oxidised S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (copper oxidised as per IS 1378) 250 x 10mm complete all as specified and directed.
61M&L for 100mm thick cement concrete 1:4:8 type C2 (using 40mm graded stone aggregate complete all as specified and directed.
62Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%) complete all as specified and directed.
636mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of R.C.C. slabs and beam complete all as specified and directed.
64Pre-painted galvalume aluminum zinc coating profiled steel sheet 0.50mm thick (total coated thickness as per IS 15965) of an colour having tensile strength of 550 Mpa as in roofing including vertical / curved surfaces covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
65Note: It shall be coated with hot dip alloy of 55% aluminium 43.5% zinc 1.5% silicon and finished with resin coat on both surfaces @ 150gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self-tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voilds between sheets, sheet & fasteners etc., fixing system shall be as per manufacturer's instructions and shall be safe against effects of wind velocity.
66Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position complete all as specified and directed.
67Provinding and fixing framed work such as grills, gratings with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
68Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m all kind of soil complete all as specified and directed.
69Providing and laying RCC M-30 grade with minimum cement content of 350 kg/cum for all works above plinth level complete all as specified and directed.
70Providing and fixing centering and shuttering including strutting, propping and removal of form work for columns, piers, abutments, pillars, posts and struts complete all as specified and directed.
71M&L for steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed.
72Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand complete all as specified and directed.
73M&L for precast cement concrete block masonry with solid blocks, exceeding 10cm in width and setting in mortar, complete set in cement mortar 1:6, type C1, 1:3:6 complete all as specified and directed.
74Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing, wall pannels and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead complete all as specified and directed.
75Providing and fixing tiled false ceiling of specified materials of size 595 x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length and of size 24 x 38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross 'T' of size 24 x 25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main 'T' at 600mm
76center to center to form a grid of 1200 x 600mm and secondary cross 'T' of length 600mm and size 24 x 25mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200 x 600mm panel to form grids of 600 x 600mm and wall angle of size 24 x 24 x 0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors. Main 'T' runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners,
774mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge. GI metal ceiling lay in perforated tegular edge global white color tiles of size 595 x 595mm and 0.5mm thick with 8mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC (Noise
78Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black glass fiber acoustical fleece complete all as specified and directed.
79Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws complete as per architectural drawings and directions of Engineer-in-Charge.Pre-laminated particle board with decorative lamination on both sides.
80Providing and fixing ISI marked oxidised S.S. sliding door bolts with nuts and screws complete (copper oxidised as per IS:1378) 300 x 16mm complete all as specified and directed.
81Providing and fixing ISI marked oxidised S.S. handles conforming to IS:4992 with necessary screws complete (copper oxidised as 125mm length) complete all as specified and directed.
82Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embossed on the body, door weight upto 36 kgs to 80 kgs and door width from 701mm to 1000mm), with double speed adjustment with necessary accessories and screws complete all as specified and directed.
83Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
84Demolishing of existing washing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed.
85Roof treatmentSurface preparation: Providing and cleaning all roof surface to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants, complete as per manufacturer's specification.All cracks and construction joints should be either filled with epoxy putty or mortar. Supplying and applying High build elastomeric waterproofing coating. Supplying and applying waterproofing treatment to sound, moisture free concrete surface. System includes(i) Proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc.
86(ii) Carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-plasticised or equivalent expansive grout admixture supplied in 225 gm pouch, treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR Latex or equivalent.
87(iii) Application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP-2 Non-shrink cementitious grout or equivalent.(iv) Any undulated surface and pot holes shall be filled with epoxy mortar to obtain sound / levelled surface. Application of epoxy primer Nitoproof WB primer or equivalent on sound mother slab surface.
88(v) Followed by application of two coats of Nitoproof 600PF-Liquid applied single componet pitch free polyurethane coating supplied in 25 kg drum coverage of min @ 2.3 kg/m2 to achieve 1.5mm dry film thickness in two coats placing glass fabric reinforcement min 225 gsm between 1st coat and second coats complete including all tools and tackles as per manufacturer's specifications.
89(vi) Coating shall be having crack bridging of 2mm, elongation (ASTMD 412) > Min 500%, Tensile Strength (ASTM D412) - 2.5 N/mm2, Recover from elongation (ASTM D412) - 95%, Min 80% solid content, Tear resistance (ASTM D624) - 15 Kn/m, Shore A Hardness (ASTM D2240) - 50, water vapour transmission not more than 1g/m2/hr, water permeability (DIN 1048) - Nil, Service temperature -40oC to 70oC, Flash point > 70oC.
90HSE Guidelines: It is recommended to provide adequate general and local exhaust ventilation, provide protection to eye, face, hand and other skin by wearing appropriate gloves, goggles, face shields, respiratory protection etc., as directed in SDS of the product.Note: Work should be executed only through authorised company applicator and company as well as contractor should give written guarantee for 10 years for roof treatment to the department and if any leakage or seepage during guarantee period. Contractor as well as company are responsible for the same and rectified without no extra cost.
91Supplying and applying Nitocote PU Aliphatic or equivalent shall be applied to a dry surface in two coats at wet film thickness between 250 and 300 microns per coat which will cure to give a finished dry film thickness of between 150 and 180 microns per coat. Additional coats may be required for extreme exposure conditions. Nitocote PU Aliphatic is supplied in white colour in 20 litre pails. Nitocote PU Aliphatic, a polyurethane, protective coating. The coating shall possess excellent chemical and UV resistance properties. It shall be compatible with concrete, specific gravity @ 25oC : 1.40 Tensile strength : 15 N/mm2 (ASTM D412)
92elongation @ break : 165% (ASTM D412) Tear resistance : 50 N/mm2 (ASTM D624) Hardness : 85 (ASTM D2240) Tack free time @ 25oC.Note: Equivalent construction chemical of other specification makes can also be used.
93M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate complete all as specified and directed.
94M&L for 10mm thick cement plaster in CM 1:3 with a mixture of water proofing liquid @ 3% by weight of cement on dried concrete surfaces finished fair and even without using extra cement complete all as specified and directed.Note: Water proofing liquid shall be measured and paid seperately.
95Supply only integral water proofing in liquid complete all as specified and directed.
96Dismantling of old S.W. pipes 150mm dia including breaking of joints and bed concrete stacking of useful materials near the site within 50m lead and disposal of unserviceable materials into municipal dumps complete all as specified and directed.
97Dismantling of old S.W. pipes 200mm dia including breaking of joints and bed concrete stacking of useful materials near the site within 50m lead and disposal of unserviceable materials into municipal dumps complete all as specified and directed.
98Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes 150mm dia with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints complete all as specified and directed.
99Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes 200mm dia with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints complete all as specified and directed.
100Providing and laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) all-round S.W. pipes 150mm dia including bed concrete as per standard design complete all as specified and directed.
101Providing and laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) all-round S.W. pipes 250mm dia including bed concrete as per standard design complete all as specified and directed.
102Constructing soak pit 1.20 x 1.20 x 1.20m filled with brick bats including NP2 drain pipe 100mm diameter and 1.20m long complete as per standard design complete all as specified and directed.
103Precast RCC HUME PIPE SEPTIC TANKS on site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete for 25 users complete all as specified and directed.
104Providing and laying polished granite stone flooring / skirting window cills in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing complete all as specified and directed.
105M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
106M&L for providing edge moulding to 18-20mm thick granite stone any description of counters vanities including machine polishing to edge to give high gloss finish complete all as specified and directed.
107Providing and fixing SS curtain rods of wall thickness 1.25mm with two SS brackets fixed with screws and wooden plugs wherever necessary complete 25mm dia complete all as specified and directed.
108Scarifying the existing bituminous road surface to a depth of 50mm and disposal of scarified material within all lifts and lead upto 1km (by mechanical means) complete all as specified and directed.
109Providing and applying prime coat using hot straight run bitumen of grade VG-10 on existing surface @ 0.5kg/sqm including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specification complete all as specified and directed.
110Providing and applying tack coat using hot straight run bitumen of grade VG-10 on existing surface @ 0.25kg/sqm including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specification complete all as specified and directed.
111Providing and laying Bituminous macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment, including preparation and consolidation of Bituminous concrete rolling with power road roller of 8-12 tonne capacity with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, 50mm compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of
112total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity, complete all as specified and directed.Notes: (a) BM shall be as per MORTH specifications including minimum binder content mention therein and as detailed in Particular Specifications.b) Supply and mixing of hydrated lime or cement or both in case TSR is less than 80% is deemed to be included rate quoted.
113Providing and laying Semi-dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment, including preparation and consolidation of Semi-dense bituminous concrete rolling with power road roller of 8-12 tonne capacity rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, 40mm compacted thickness with bitumen of grade VG-
11430 @ 5.5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity, complete all as specified and directed.Notes: (i) Thickness of semi dense asphaltic concrete and quantities of materials as mentioned in Particular Specifications / SSR are the minimum. The quoted rate shall also be deemed to include for provision of more materials in comparison to those mentioned / specified in the item, if required, to achieve the required level, gradient, camber and shape all as directed by the GE.
115(ii) Hot mix plant of adequate capacity shall be used for heating and mixing stone and fine aggregate and binder (bitumen) and semi dense asphaltic concrete shall be laid in single layer with self propelled mechanical paver all as directed by the GE.
116Providing and applying 2.5mm thick road marking strips (retroreflective) of specified shade / colour using hot thermoplastic material by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc, complete all as specified and directed.
117Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed.
118Dismantling of stone pitching laid in cement mortar including stacking of serviceabe material and disposal of unserviceabe material to contractors store complete all as specified and directed.Note: The stone retrived from this item shall not be allowed for reuse in the work.
119Supply, installation, commissioning of water cooler electric driven (single phase) having approx storage capacity of 150 litres including water purifier system and nominal cooling capacity of 150 litres per hour including provisioning of water supply connection from nearest water point complete all as specified and directed.
120Supply, install & commissioning for high wall split unit air conditioner of capacity 1.5 TR indoor / outdoor complete with cordless remote control unit and within built air ionizer for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity complete all as specified and directed.
121Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors complete all as specified and directed.
122Taking down unserviceable DBs / switch fuse units any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed.
123Taking down old aluminium unserviceable sub main wiring any type complete all as specified and directed.
124S&F, wiring for light point / fan point / exhaust fan point / call bell / point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in recessed / concealed in brick / concrete / stone wall medium class PVC conduit with modular switch, modular plate suitable size GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed.
125All as per Sl item No. 101 above, but for single pole and neutral with a two pin and earth plug and socket outlet on independent board with other circuit with the cable of 4 sqmm size and earth continuity conductor of 4 sqmm size PVC insulated copper stranded conductor cable (sheet metal enclosure with plug & socket shall be paid separately).
126S&F, wiring for circuit of 15 A power point alongwith earth wire 2 x 2.5 sqmm + 1 x 2.5 sqmm of FRLS PVC insulated copper conductor, single core cable in recessed / concealed type medium class PVC conduit as required complete all as specified and directed.Note: Two runs of cable, one run of earth continuity conductor and one non PVC conduit will be measured as unit length.
127S&F, suitable size GI box with modular plate or cover in front of surface in recess or in wall including providing and fixing 3 pin 5/6A modular sockets outlet and modular switch connections as required complete all as specified and directed.
128All as per Sl item No. 104 above but for 15/16 Amps switch & socket modular type.
129S&F, ceiling rose surface, backlite 3 terminals 65mm x 50mm complete all as specified and directed.
130S&F, stepped type electronic fan regulator complete all as specified and directed.
131S&F, sheet metal enclosure (for ACs / equipment) SPN two pin and earth plug and socket metal clad complete with one MCB SP 20 Amps 240 volts complete all as specified and directed.
132M&L for sub main wiring with two single core PVC insualted unsheathed stranded FRLS copper conductor cable 2.5 sqmm size drawn through in and including surface PVC conduit / flexible conduit wherever required medium grade with all accessories including continuous earth wire PVC insualted unsheathed cable 2.5 sqmm copper stranded conductor and connection to common earth and earth dolly including connecting to main board complete and cutting chases of suitable girth where required on brick / concrete surface & making good disturbed surface as per existing surface complete all as specified and directed.
133All as per Sl item No. 109 above, but for 2 x 4 sqmm + 1 x 4 sqmm as earth wire.
134All as per Sl item No. 109 above, but 2 x 6.0 sq.mm + 1 x 6.0 sq.mm as earth wire.Note for Sl item No. 109 to 111: Two runs of cable, one run of earth continuity conductor and one non PVC conduit will be measured as unit length.
135All as per Sl item No. 109 above, but for 4 x 6 sqmm + 2 x 6 sqmm as earth wire.
136All as per Sl item No. 109 above, but for 4 x 10 sqmm + 2 x 10 sqmm as earth wire.Note for Sl item No. 112 & 113: Four runs of cable, two runs of earth continuity conductor and one non PVC conduit will be measured as unit length.
137S&F, LED lights fitting 1 x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
138S&F, energy saving surface mounting 2' x 2' LED 36 watt low glare luminaries with all accessories pre-wired complete all as specified and directed.
139S&F, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
140S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
141S&F in replacement of energy saving, enviromental friendly highbay fitting with high power COM LED as light source of 110-120 W complete all as specified and directed.
142S&F, MCB 'C' curve single pole 6 Amps to 32A 240 volts complete all as specified and directed.
143S&F, MCB 'C' curve SPN 40 to 63 Amps, 240 volts complete all as specified and directed.
144S&F, MCB TPN 63Amps, 240 volts complete all as specified and directed.
145S&F, MCB TP 40 Amps, 240 volts complete all as specified and directed.
146S&F, MCCB TP 63 Amps, 240 volts 16 KA complete all as specified and directed.
147S&F, MCCB TPN 125 Amps, 240 volts 16 KA complete all as specified and directed.
148S&F, sheet steel enclosure MCB DBs factory fabricated phosphatised powder painted, single pole & neutral with 200 Amps rated bus-bar, 240 volt, AC 8 ways, double door type complete all as specified and directed.
149S&F, sheet steel enclosure MCB DBs factory fabricated phosphatised powder painted, single pole & neutral with 200 Amps rated bus-bar, 240 volt, AC 12 ways, double door type complete all as specified and directed.
150S&F, sheet steel enclosure MCB DBs factory fabricated phosphatised powder painted, triple pole & neutral with 200 Amps rated bus-bar, 240 volt, AC 4 ways, double door type with fixing arrangement of MCCB as incomer complete all as specified and directed.
151S&F, sheet steel enclosure MCB DBs factory fabricated phosphatised powder painted, triple pole & neutral with 200 Amps rated bus-bar, 240 volt, AC 8 ways, double door type with fixing arrangement of MCCB as incomer complete all as specified and directed.
152S&F, vertical TPN distribution board for housing MCCB & MCB triple pole 12 way complete and including with incomer MCCB 100 Amps 3 pole, breaking capacity 18 kA - 01 No complete all as specifed and directed.Note: MCB's will be measured and paid as separate item.
153Taking down existing ceiling / wall fan / exhaust fan of 300 to 600mm sweep cleaning, servicing, rewinding, replacing bearing, painting and refixing complete all as specified and directed.
154S&F, ding dong bell of 230V complete all as specified and directed.
155S&F, ceiling fans complete with blades, down rods, electronic remote regulator and accessories, 230 V, 1200mm sweep minimum air delivery 210 CFM with service value 6.00 BEE five star rated with Brushless Direct Current motor (BLDC) complete all as specified and directed.
156S&F, exhaust fan steel body AC single phase 230V of size 300mm sweep with blades, frame and louvers complete all as specified and directed.
157S&F, air termination single pointed aluminium rod single pointed at top and properly threaded at bottom end 300mm long 12mm dia complete all as specified and directed.
158M&L for providing test terminal point block, made out of gun metal or phosphors bronze of size 75mm x 75mm x 25mm, drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and directed.
159S&F, aluminium strip 25 x 3.15mm with saddles, screws, porcelain insulators and PCC blocks etc., for roof conductors and down conductors above ground complete all as specified and directed.
160M&L for earthing complete with galvanized steel plate electrode 60cm x 60cm x 6mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron, connected to machinery / equipment installed at power house / substation including necessary excavation & earth work.
161The rate also include charcoal and salt in alternate layers 20mm dia pipe (light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete 1:3:6 type C1, 40mm thick RCC 1:2:4 type B1 cover and CI frame all as shown in electrical plate No. 3 of SSR-2009 Part I.
162Making connection of G.I. distribution branch with G.I. main of 50 to 80mm nominal bore sizes by providing and fixing tee including cutting and threading the pipe complete all as specified and directed.
163M&L for cutting existing steel / G.I. tubing of upto 40mm dia for alteration or addition including insertion of tee complete all as specified and directed.
164Supply and laying for providing and fixing, GI pipes conforming to IS-1239 (medium grade of size 80mm complete with GI fittings including laying in trenches and refilling complete all as specified and directed.
165Supply and laying for providing and fixing, GI pipes conforming to IS-1239 (medium grade of size 40mm complete with GI fittings including laying in trenches and refilling complete all as specified and directed.
166Supply and laying for providing and fixing, GI pipes conforming to IS-1239 (medium grade of size 25mm complete with GI fittings including laying in trenches and refilling complete all as specified and directed.
167S&F, gun metal sluice valves class PN 1.6 80mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
168S&F, gun metal globe or gate valves 40mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
169S&F, gun metal globe or gate valves 25mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
170Excavation for GI pipe trenches in any type of soil, depth upto 1.2m including dressing of sides lift upto 1.5mtr including getting out the excavated soil, refilling with sand or good soil after laying of pipe etc., in layers of 20cm ramming, watering and disposal of surplus excavated soil as directed within a lead of 50m in all kinds of soil complete all as specified and directed.
171Constructing masonry chamber 60 x 60 x 75cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as specified and directed.
172Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with PVC float valve with fittings and the base support for tank capacity 2000 ltr complete all as specified and directed.
173Taking down old unserviceable pipe of any type any size including all connected items like bends, tees, fixtures complete all as specified and directed.
174Taking down old UG cable of any size, any type upto 400 Sqmm from the ducts / wall / trench complete all as specified and directed.
175Supply, laying, jointing & testing (in trench / on wall surface / in duct / through pipe / tray) of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conuctor (confirming to IS-7098) of 400 Sqmm 3.5 core (T/F to Panel 1) cross sectional area as under alongwith suitable size HDPE PIPE complete all as specified and directed.
176Supply, laying, jointing & testing (in trench / on wall surface / in duct / through pipe / tray) of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conuctor (confirming to IS-7098) of 300 Sqmm 3.5 core (Panel 1 to Abhay shop panel) cross sectional area as under alongwith suitable size HDPE PIPE complete all as specified and directed.
177Supply, laying, jointing & testing (in trench / on wall surface / in duct / through pipe / tray) of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conuctor (confirming to IS-7098) of 70 Sqmm 3.5 core cross sectional area as under alongwith suitable size HDPE PIPE complete all as specified and directed.
178Supply, laying, jointing & testing (in trench / on wall surface / in duct / through pipe / tray) of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conuctor (confirming to IS-7098) of 50 Sqmm 3.5 core (cranes DB / compressor / washing points) cross sectional area as under alongwith suitable size HDPE PIPE complete all as specified and directed.
179Supply, laying, jointing & testing (in trench / on wall surface / in duct / through pipe / tray) of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conuctor (confirming to IS-7098) of 35 Sqmm 3.5 core (P203 DBs) cross sectional area as under alongwith suitable size HDPE PIPE complete all as specified and directed.
180Taking out / dismantling of old unserviceable LT panel board, disconnecting all cable connections and demolition of panel concrete / brick foundation, MCCBs MCBs of any size and remove from side complete all as specified and directed.
181Supplying, installation, testing & commissioning of cubical type LT panel outdoor type (IP 65) conforming to IS/IEC 61439, ATT certified suitable for 415 V, 3 phase, 4 wire, 50 HZ AC supply, comprising of the following:-
182(a) Enclosure (IP 65 protection) fabricated in compartmentalized design from CRCA sheet steel of 3.15mm thick for frame work and 4mm thick covers for gland plates, including cleaning & finishing complete with 7 tank process for powder coating in approved shade having 750 Amps capacity extensible type TPN aluminium bus bars of high condutivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec, bottom base channel of MS not less than 100mm x 50mm x 5mm fabrication shall be done in
183transpotable sections, entire enclosure shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 02 Nos earth studs, solid connection from main bus bar to swich gears with required size of aluminium bus bars and control wiring with minimum 2.5 sq.mm PVC insulated copper conductor single core, cable alleys, cable gland plates in two half complete as required.(b) Bus chamber: 750 Amps rated aluminium busbar - 04 Nos.(c) Incoming: MCCB 500 Amps, 4 pole, 415 volt, 36 kA with thermal magnetic release - 01 No.
184(d) Outgoing: MCCB 350 Amps, 4 pole, 415 volt, 36 kA with fixed thermal megnetic release (for shop) - 01 No.MCCB 100 Amps, 3 pole, 415 volt, 25 kA with fixed thermal megnetic release (for bldg 201 - 02 Nos, 202 & washing plant - 01 No, air compressor - 02 Nos) - 05 Nos.MCCB 63 Amps, 3 pole, 415 volt, 25 kA with thermal megnetic release (security lights) - 01 No.Digital multifunction voltmeter / Ammeter / Frequancy / PF meter, cl 0.5 with RS485 - 01 No.Indication LED set of three - 01 No.
185(e) ON LOAD CHANGE OVER SWITCH: 415V, 4 pole of capacity 630 Amps capacity - 01 No.Note: Cost of cable glands, MCCB spreader terminals, cable lugs etc shall deemed to be included in the quoted rate. Panel should be spacious for easy maintenance and cable connection.
186Supplying, installation, testing & commissioning of cubical type LT panel indoor type (conforming to IS/IEC 61439, ATT certified) suitable for 415 V, 3 phase, 4 wire, 50 HZ AC supply comprising of the following:-
187(a) Enclosure conforming to IS/IEC 61439, fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and 4mm thick covers for gland plates, including cleaning & finishing complete with 7 tank process for powder coating in approved shade having 600 Amps capacity extensible type TPN copper bus bars of high condutivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec, bottom base channel of MS not less than 100mm x 50mm x 5mm fabrication shall be done in transpotable sections,
188entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 02 Nos earth studs, solid connection from main bus bar to swich gears with required size of aluminium bus bars and control wiring with minimum 2.5 sq.mm PVC insulated copper conductor single core, cable alleys, cable gland plates in two half complete as required.(b) Incoming: MCCB 315 Amps, 4 pole, 415 volt, 36 kA with thermal magnetic release - 01 No.(c) Outgoing: MCCB 160 Amps, 3 pole, 415 volt, 36 kA with fixed thermal megnetic release - 03 Nos.
189MCCB 100 Amps, 3 pole, 415 volt, 25 kA with fixed thermal magnetic release - 03 Nos.MCCB 63 Amps, 3 pole, 415 volt, 25 kA with thermal magnetic release - 02 Nos.Digital multifunction voltmeter / Ammeter / Frequancy / PF meter, cl 0.5 with RS485 - 01 No.Indication LED set of three - 01 No.Sheet metal enclosure complete including necessary wiring - 01 No.Aluminium bus bar 600 Amps, 3 phase and neutral - 01 No.Note: Cost of cable glands, MCCB spreader terminals, cable lugs shall deemed to be included in the quoted rate. Panel should be spacious for easy maintenance and cable connection.
190Supply, installation, testing & commissioning of outdoor type, step down, transformer double copper wound 22KV/0.433 KV, 200 KVA capacity, energy efficient, conforming to std & tolerance as per IS-1180 (Part-I 2014). BIS level-II, ONAN cooled, oil immersed, complete with first filling of IS:335, ISI marked, filtered & dehydrated transformer oil and other standard fittings / accessories and off load Tap Changer: -
191(i) Lifting lugs, top cover lugs.(ii) Earthing Terminals.(iii) Conservator with oil gauge glass, oil filing hole plug and drain plug.(iv) Transformer drain valve.(v) Bi directional rollers.(vi) Explosion vent with diaphragm.(vii) Thermometer pocket.(viii) Air vent plug.(ix) Silica gel breather.(x) Rating & diagram plate inspection cover terminal marking plate.(xi) Cooling radiators.(xii) LV neutral bushing brought out for external for earthing.(xiii) First fill of EHV grade transformer oil as per IS:335.
192(xiv) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temperature reading pointer, max temperature indicator and resetting device.Note: The transformer mush have BIS certification, BEE star labelling and a valid type test report issued by NABL accredited BIS approved lab.
193Supplying, transporting to site, erecting & fixing in position, steel tubular swaged and welded poles of overall height 11 metres, type 410 SP-55, IS-2713 marked with mild steel base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting 05 Nos band / strips with fluorescent, PO box red synthetic enamel paint (30cm wide each) at a distance of 30cm from
194plinth block of colour black and green with numbering of poles, complete all as specified and directed.Note: Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted.
195Supply, fabricating & fixing mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections such as angle iron, channel, plate and flats including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
196S&F, HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators and mild steel frame with operating mechanism worked from ground level including operating rod for current rating upto 400 Amps, 11000 volts complete with 6 lever pad locking arrangements, MS clamps, nuts, bolts and washers etc; including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
197S&F, lightning arrestor HT 11 KV station class complete with all fittings, transmission class, discharge capacity 65 kilo Amp complete all as specified and directed.
198Supply, laying & testing cable XLPE insulated earthed screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sqmm complete all as specified and directed.
199Excavation for cable trenches in any type of soil, depth upto 1.2m including dressing of sides lift upto 1.5mtr, including getting out the excavated soil, refilling with sand or good soil after laying of cable / pipe etc., in layers of 20cm, ramming, watering and and disposal of surplus excavated soil as directed, within a lead of 50m in all kinds of soil within a lead of 50 metres complete all as specified and directed.
200Supplying and laying, unreinforced precast concrete, class LV, type I, flat size 250mm x 150mm x 40mm cable cover ISI marked laid transverse to the LT cable complete all as specified and directed.
201S&F, cable path indicator made of cast iron plate of size 150mm dia and 4mm thick indicating cable size and voltage. Cast iron path indicator shall be fixed on MS angle iron of size 30mm x 30mm x 5mm and 900mm long with 02 Nos nuts and bolts of suitable size complete all as specified and directed.
202M&L for cutting / horizontal boring across bituminous road / floor for laying of pipe / cables not exceeding 20cm wide and not exceeding 45cm deep including refilling with material and watering well ramming / compacting and making good with premixed bituminous macadam 150mm thick complete all as specified and directed.
203M&L for GI pipe light grade 50mm dia fixed to pole with MS clamps of suitable size nut & bolts / laid in trenches complete all as specified and directed.
204M&L for GI pipe light grade 80mm dia fixed to pole with MS clamps of suitable size nut & bolts / laid in trenches complete all as specified and directed.
205M&L for GI pipe light grade 100mm dia fixed to pole with MS clamps of suitable size nut & bolts / laid in trenches complete all as specified and directed.
206M&L for GI pipe light grade 150mm dia fixed to pole with MS clamps of suitable size nut & bolts / laid in trenches complete all as specified and directed.
207Supply, installation, testing & commissioning of silent Diesel Engine driven factory assembled generating set of capacity 200 KVA, 3 phase, 4 wire, 50 Hz, 1500 RPM complete with Engine and alternator mounted on a common frame with AVM pads, acoustic enclosure, relay panel for automatic starting on mains failure safety control and metering equipment mounted on & including common base frame and installed on PCC/RCC foundtaion as recommended by manufacturer and approved by GE and suitable for ambient conditions at Pune, environmental eco-friendly as per CPCB-IV plus norms including the following all as specified and directed.
208Note: PCC foundation work as per manufacture instructions, anti-vibration pads and other standard accessories and comprising of the following: -
209Diesel EngineNo. Of cyclinders as per OEM standard, inline arrangement with standard gross Engine power to drive alternator to deliver minimum 200KVA) at atmospheric conditions of Pune, water cooled turbocharged with after cooled, rated output 1500 RPM and overspeed trip 1650 RPM, Engine with electric start, compression ignition, stroke cycle designed to run continuously at 1500 RPM conforming to IS 2002, ISO-3046, BS 5514 standards. Diesel engine should comply with CCB P-IV plus norms.
210The Diesel Engineer are comprising of following:-(i) Radiator with fan.(ii) Fuel injection equipment with Electronic Governor having CRS (Common Rail System) and DG performance class G3.(iii) Dry type air cleaner.(iv) Exhaust silencer type NA, max allowable backpressure (kPa) 17, exhasut temperature (deg C) 550.(v) Lub oil filter (spin on type).(vi) Fuel oil filter (spin on type).(vii) 24V electric starting system.(viii) Battery charging alternator.(ix) Stop solenoid.(x) Lube oil pressure gauge.(xi) Water temperature gauge.(xii) Lube oil temperature gauge.(xiii) Battery voltage voltmeter.
211(xiv) Extended life coolant.(xv) First fill lube oil.AlternatorAlternator type 4P, rotating field, automatic voltage regulaor and voltage regulation +1%, suitable for continuous duty operations rated at 1500 RPM, 415V, 0.8 PF, 50 Hz, current (3P) self-excited & self-regulated, brushless, 'H' class insulation, temperature rise (Deg C) 125, coupling type Fle Disc, unbalanced load capability 25% of rated Amps, floor mounted with anti-friction sealed ball bearing on end. The alternator conforms to SI:13364 (Part-II) suitable for tropical condition including marking cable connection.
212Accoustic enclosure:-(a) Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA@1 mtr at 75% Load under free field conditions.(b) The folloiwng are some technical features of Acoustic Enclosure:(i) The enclosure is modular in construction.(ii) Base frame is made of structural steel.(iii) Durable industrial locking system is provided on doors.(iv) Door gaskets are made of high quality EPDM material.(c) Corrosion Resistance: To make the enclosure weather proof:-
213(i) All sheet metal parts / components are hot dipped in minimum seven tanks process, pretreated and passivated.(ii) Sheet metal components are with pretreated and passivated base powder coated.(iii) Base frame is epoxy coated / powder coated.(iv) Zinc passivated hardwares are used to avoid rusting.Acoustic insulation: (i) Sound proofing of the enclosure is done with quality rockwool confirming to IS-8183 Standard.(ii) Acoustic foam shall be fire retardant and fire resistant.
214(iii) Attenuates are provided to control sound at entry and exit of container.(iv) Specially designed residential silencer is provided.(d) Ventilation and Air Circulation: Exhaust pipe inside enclosure is thoroughly insulated by cladding of rock wool aluminium sheet.(e) Electrical: Neutral body earthing points at the sides of enclosure are isolated through moulded compound.
215(f) Safety: Emergency push button to stop the DG set from outside, low fuel oil level, low lube oil pressure, low coolant level, high engine temperature. The canopies being offered are for output of noise level<75 dbA at a distance of 1 meter average as per the CPCB IV norms.Batteries: 02 Nos 12V 180Ah batteries with leads for electric starting.
216Paint: DG set and panel package will be painted with powder coated type paint.STANDARD GENSET CONTROLLER UNIT WITH CONTROL PANEL:Genset controller unit with totally enclosed, steel construction control panel suitable for indoor floor / wall mounting installation having standard safeties and display parameters.
217AMF PANEL: Supply, install, testing & commissioning of AMF panel for 200 KVA DG set factory made, outdoor cubical type as per IE/CPRI rules with IP-65 protection, dust and vermin proof, compartmentalised, made of 3.15mm thick CRCA sheet, fixed on MS angle iron frame of 50 x 50 x 6mm thick of required type for supporting double door both sides open type with necessary locking arrangement with slope roof on top duly painted with two coats of powder coated paint with seven tank process complete and having separate doors inside for accommodating all incoming / outgoing cables and other relevant
218standards mounted on and including provision of necessary plinth in PCC 1:3:6, type C1 for foundation and PCC pillars with suitable size of nut, bolts & washers grouted as required at site and as per manufacturers instructions including provision of the following items: -
219(a) Bus bar with electrolytic aluminium bus bar (for mains and DG supply incoming and outgoing) suitable for 400 Amps capacity for 3 phase and neutral (TPN) (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrink insulating sleeves.
220(b) Three phase 4 pole, power contractor, 315 Amps, AC 3 duty for ON-OFF the DG and mains supply-02 Nos.(c) MCCB 315, 35KA for ON-OFF the DG and mains supply - 02 Nos.(d) On load change over switch 315 Amps for Bypass AMF panel in case of power contractor faulty - 01 No.(e) Automatic generator controller unit with total control wiring with necessary relays and control fuses, auxiliary contacts - 01 No.
221(f) Digital type voltmeter panel mounted flush type of size 96 x 96 sqmm 3 phase class 1.0 within built selector switch complete - 02 Nos.(g) Digital type Ammeter panel mounted flush type of size 96 x 96 sqmm 3 phase class 1.0 within built selector switch and suitable CTs complete - 02 Nos.(h) RYB phase indicators LED type with control fuses - 02 Sets.
222(j) Digital energy meter panel mounted 96 x 96mm with necessary CTs - 01 No.Note: Drawing of panel board and connections shall be got approved by GE before manufacture of panel board.
223Design, supply, installation, testing & commissioning, electrically operated 15 Ton capacity double girder flame proof EOT crane with floor operated pendant push button as specified below:(a) Capacity of crane -15 Ton.(b) Span 16.80 Mtr (Approx).(c) Hook height-10 Mtr (Approx).(d) Bay length-48 Mtr Approx.(e) Speed-Hoist speed-03 mtr/min. (f) Cross travel speed-15mtr/min.(g) Long travel speed-15 Mtr/Min.
224Note: (i) Electrically operated cranes shall be got executed through specialist agency having minimum 05 years experience in execution of EOT cranes and the agency shall be got approved by GE/GE(I).(ii) Actual available span & other dimension are required to be checked by contractor before quoting.(iii) Cranes shall be executed (installed and commissioned) with the authorised representative of the manufacturer.(iv) The 15 Ton EOT crane shall be installed on the existing runway beam and RCC column by providing rail all as directed by Engineer-in-Charge.
225Supply, installation, testing & commissioning of vehicle washing plant complete with pressure filter of 100 bar capacity & vehicle washing facility alongwith its distribution hose pipe of length 10m with flow rate 12 LPM alongwith built in controls & electrical panels with & including FRP 5000 gallons water storage tank including RCC foundation of suitable capacity complete all as specified and directed.
226Supply, installation, testing & commissioning of air compressor with 20hp motor with canopy alongwith air receiver tank, max pressure 10 bar, air delivery 500-600 L/min complete connected items viz, compressed air pneumatic pipe line system comprising 30 RM of 1 inch dia GI pipe and 150 RM of 3/4 inch dia GI pipe complete with fittings, clamps, supports, valves and connected accessories with 06 Nos outlet points, each outlet point comprising ball valve, FRL unit (Filter-Regulator-Lubricator / moisture separator), quick release coupling, house nipple, male / female plug, 10mm dia flexible high-pressure air hose pipe and pneumatic air blow gun, controls & electrical panels and installation complete all as specified and directed.
227S&F, ultra-thin nylon netting of adequate tensile strength fixed with reusable hooks to facilitate painting fixed to structural members of hanger ceiling to provide complete bird proofing inside hanger including PVC made to shape bird landing arrester 120mm height complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073271
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.65 Crore
LAST DATE 12-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition / Alteration Of Icv Abhay Workshop (Building No. P-264) Specialist Garage P-201 & Tank Garage P-202 At Vrde, Ahmednagar
Basic Detail
Tender No 85344
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 15 Oct 2026
Submission Date 12 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 4.65 Crore
Tender Fee 2000
EMD 5.40 Lakhs
Exemption Available
Document List
2cf6dd6d-9a0a-443f-9cd8-2498c63ed897.html
85344_Tender.pdf
BOQ_890621.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

2cf6dd6d-9a0a-443f-9cd8-2498c63ed897.html

pdf

85344_Tender.pdf

xls

BOQ_890621.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender