Tender For Repair/ Maintenance Of All Types Of Fans, Geysers, And Other Connected Items At Ahrr Complex Under Ge E/M repair renovation Hospital Delhi Cantt-10
Tender Value
30 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
17 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of All Types Of Fans, Geysers, And Other Connected Items At Ahrr Complex Under Ge E/M repair renovation Hospital Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down Old U/S Ceiling fan of Sweep, any make, 1200 mm, 230 volts of any make from any height of the building for depositing to MES store all as specified and as directed by Engineer in charge. |
| 2 | Taking down Old U/S Ceiling fan of Sweep, any make, 1400 mm, 230 volts of any make from any height of the building for depositing to MES store all as specified and as directed by Engineer in charge. |
| 3 | Taking down Ceiling fan of Sweep, any make, 1200/1400mm, 230 volts of any make & size from any height of the building for finding out the defects such as Capacitor, bearing etc and servicing / overhauling the same, including replacing minor accessories like locking pins, rubber real, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to included in the unit rate quoted. |
| 4 | Taking down Exhaust fans heavy duty of Sweep 200 to 600mm, 230 volts of any make & size from walls/ trusts for finding out the defects such as Capacitor, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc or depositing to MES store if irrepairable all as specified and as directed by Engineer in charge. Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to included in the unit rate quoted. |
| 5 | Taking down Wall mounted/Air circulator/Pedestal fans of Sweep upto 630 mm, 230 volts of any make & size from walls/floors for finding out the defects such as Capacitor, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.. Note for Item Sl No 3 to 5 : (i). Cost of Bearing, Capacitor and rewinding will be measured and paid separately under the respective item of the Schedule. (ii) Labour element for removing and refixing the Bearing and removing and rewinding the winding will be measured in the respective of the schedule. (iii) Misc items such as nut & bolts, Rubber bush & locking pin etc required for satisfactory completion of job deemed to be inclusive of the unit rate. |
| 6 | Rewinding of fan motor and rewinding the same with single strand fine enamel copper conductor of same guage weight and turns and keeping the windings into hot air oven till the moisture evaporates including testing and commissioning complete. Note : (1) All the misc items such as impregranted paper, warnising, cotton tape and other misc items required for satisfactory completion of job deemed to be included in the unit rate.(2) The above repairs are considered to meet the anticipated requirement if any and based on the site requirement the scope will be handed over to the Contractor. |
| 7 | All as per item No 6.00 here in above but for Exhaust fan 200 to 380 mm sweep. |
| 8 | All as per item No 6.00 here in above but for Exhaust fan 450 mm sweep. |
| 9 | All as per item No 6.00 here in above but for Pedestal /Air circulator/ Wall mounted fan upto 630 mm sweep. |
| 10 | Supply only ball bearing suitable for ceiling / exhuast fan/ Pedestal fan/ Wall fan of any type / size / make, complete all as specified and directed. |
| 11 | Supply only capacitor of 2.5 mfd, 440V, 50 Hz suitable for ceiling / exhaust / cabin / air-circulator / Padestal fan of any type / make / size, complete all as specified and directed by Engr-in-Charge. |
| 12 | All as per item no 11.00 here-in-before but of 3.15/4 mfd capacity. |
| 13 | All as per item no 11.00 here-in-before but of 6/8.0 mfd capacity. |
| 14 | Supply only metallic fan blades (Set of 3 or 4 blades) of existing pattern & colour scheme including screws suitable for ceiling fan of any make / model / sweep size, complete all as directed. |
| 15 | All as per item no 14.00 here-in-before but for Exhaust fan of 225 to 380 mm sweep size. |
| 16 | All as per item no 14.00 here-in-before but for Exhaust of 450 mm sweep size. |
| 17 | All as per item no 14.00 here-in-before but for Wall fan/Air circulated fan of upto 630 mm sweep size. |
| 18 | Supply only factory made ceiling fan down rod 0.45 m long, made out of heavy grade MS conduit of 19/20 mm outer dia, with hole at both ends for passing cable, cut at one end for fixing of fan, hole at other end for fixing fan clamp, duly painted with white synthetic enemel paint of 1st quality, complete all as specified and directed. |
| 19 | All as srl item no 18.00 here-in-before but 0.6/0.75 m long complete all as specified and directed. |
| 20 | All as per item no 18.00 here-in-before but 0.9 m long complete all as specified and directed. |
| 21 | Supply and fix in replacement of fresh air fan of PVC body single phase, 240 volts, upto 1200 RPM of 200mm sweep, copper winding complete all as specified and directed by Engr-in-Charge. |
| 22 | All as per sl item No 21.00 But 250 mm Sweep complete all as specified and directed by Engr-in-Charge. |
| 23 | All as per sl item No 21.00 But 300 mm Sweep complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in repair cuboid type ceiling fan ready to fix in the ceiling of 2ft x 2ft sizewith integrated LED light complete with all fixing accessories complete all as specified and directed. |
| 25 | S&F ceiling fans complete with blades, down rods, electronic regulator, 230V, 1200 mm sweep min. air delivery 210 CFM with service value BEE, Five Star with BLDC Motor with remote control for speed control against irrepairable fans to be declared BER as per policy complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F ceiling fans complete with blades, down rods, electronic regulator, 230V, 1400 mm sweep min. air delivery 245 CFM with service value BEE, Five Star with BLDC Motor with remote control for speed control against irrepairable fans to be declared BER as per policy complete all as specified and directed by Engr-in-Charge. |
| 27 | S&f in repair PVC canopy suitable for 1200/1400 mm sweep fan complete all as specified and as directed by Engineer-in-charge. |
| 28 | Supply only gun metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified and directed by Engr-in-Charge. |
| 29 | Supply only ceiling fan clamp assembly along with rubber reel for any type and any description complete all as specified and directed by Engr-in-Charge. |
| 30 | Preparation of surface and painting the Ceiling fan unit of sweep 1200/1400 mm (consisting of Fan motor, blades, canopy and downrod) with one coat of synthetic enamel paint of existing colour and marking the MES number on the fan motor with suitable paints all as directed by the Engr-in-Charge. |
| 31 | Taking down defective BLDC Ceiling fan of any Sweep, any make, 1200/1400 mm, 230 volts of any make & size from any height of the building for finding out the defects and replaced the defective parts like as BLDC Circuit plate,diode,AC convertor including servicing / overhauling the same, including replacing minor accessories like locking pins, rubber real, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge. |
| 32 | Supply only BLDC ceiling fan remote control for any size of and capacity as per existing make and model , totally compatible, with speed control offering multiple speed settings and other standard controls like turning fan ON/OFF,setting timers etc. all as specified and directed by Engineer in charge. |
| 33 | M&L for lathe work to any type of fan for taking fan stator shaft from bush/ball bearing, welding shaft and grinding shaft on lathe machine to exact size required to fix on bush/ball bearing with necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge. Note : - Supply & fixing to Bearing shall be measured and paid separately under respective item of this Schedule. |
| 34 | Supply and fixing in repair PVC exhaust fan 200 mm seeep single phase 240 volts, 50 Hz connecting up including provision of PVC in repair insulated unsheathed copper conductor flexible cable 3 cores 23/0.0076 and fixed on wall by using 4 Nos 100 mm long 12 mm dia bolt nuts and washers and grouted in wall in cm (1:3) including opening in wall of suitable) size for exhaust fan & making good to disturbed surface of wall with PCC (1:2:4) Type-B-1 or cement mortar CM (1:3) against irrepairable fans to be declared BER as per policy complete all as specified and as directed by Engineer-in-Charge. |
| 35 | All as per item no 34.00 here-in-before but 250 mm sweep complete all as specified and directed by Engr-in-Charge. |
| 36 | All as per item no 34.00 here-in-before but 300 mm sweep complete all as specified and directed by Engr-in-Charge. |
| 37 | Replacement of exhaust fan motor 450 mm sweep Cooper wound 50Hzs 230 Volt complete all as specified and directed by Engr-in-Charge. |
| 38 | Replacement of exhaust fan motor 300 mm sweep Cooper wound 50Hzs 230 Volt complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply and fix in repair metal body louvers heavy duty including fixing accesoories of size 230 mm sweep to 380 mm sweep complete all as specified and directed. |
| 40 | Supply and fix in repair metal body louvers heavy duty including fixing accesoories of size 450 mm sweep complete all as specified and directed. |
| 41 | Replacement of exhaust fan clamps with legs(Brackets) suitable for 450 mm sweep exhaust fan complete. |
| 42 | Replacement of exhaust fan clamps with legs(Brackets) suitable for 300 mm sweep exhaust fan complete. Please Enable Macros to View BoQ information |
| 43 | Replacement of exhaust fan clamps with legs(Brackets) suitable for 300 mm sweep exhaust fan complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender