Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58073218

Tender For special Repair To Bldg No P-06, P-25 At Station Wksp Eme, Addn/Altn Of Jali Cover And Hightening Of Sintex At Mt Line Area For Jcos/Or Md Accn And Wksp Area Of Station Wksp Eme In The Area Of Age B/R (Project) Salaria Under Ge (West) Delhi

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
32.71 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
18 days left
EMD
65420
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Bldg No P-06, P-25 At Station Wksp Eme, Addn/Altn Of Jali Cover And Hightening Of Sintex At Mt Line Area For Jcos/Or Md Accn And Wksp Area Of Station Wksp Eme In The Area Of Age B/R (Project) Salaria Under Ge (West) Delhi Cantt-10

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-06, P-25 AT STATION WKSP EME, ADDN/ALTN OF JALI COVER AND HIGHTENING OF SINTEX AT MT LINE AREA FOR JCOS/OR MD ACCN AND WKSP AREA OF STATION WKSP EME IN THE AREA OF AGE B/R (PROJECT) SALARIA UNDER GE (WEST) DELHI CANTT-10
Sl. No. Item Description
1M&L for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde-E-250) quality 'A' including necessary welding complete all as specified and as directed.
2S&F Welded steel wire fabric weight n. exc 4kg per sqm complete to wood or steel members including cutting, welding, notching etc. complete all as specified and as direceted.
3Demolition of cement concrete (unreinforced) / sunken floor in ground floor and paving not exc. 15cm thickness (below or above ground level), removal of rubbish beyond MOD land complete all as specified and as directed.
4M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof padding/kerb, mud slopes, rounded or chamfered edge complete all as specified and directed
5Taking up or down 15 mm bore dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed
6S&F 15mm bore dia Tube medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. complete all as specified and directed
7All as per Srl item No 6.00 here-in-before but except GI steel tubing.complete all as specified and directed
8Taking up or down 20mm bore dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed
9S&F 20mm bore dia Tube medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors. complete all as specified and directed
10All as per Srl item No 9.00 here-in-before but except GI steel tubing.complete all as specified and directed
11S&F in repair 15 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.complete all as specified and directed
12S&F in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.complete all as specified and directed
13S&F in repairs 20mm GI nipple suitable for HDPE water tank complete all as specified and directed.
14S&F in repairs water tank lid for 500 ltr capacity complete all as specified and directed.
15S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, including dismantling water tank complete all as specified and directed.
16All as per Srl item No 15.00 here-in-before but except Tank. complete all as specified and directed
17S&F 1000 ltrs capacity rotational molded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, including dismantling water tank complete all as specified and directed.
18All as per Srl item No 17.00 here-in-before but except Tank.
19Demolition of brick work built in cement mortar including all quoins, arches, pillars etc including rubbish off the premises beyond MOD land complete all as specified and directed.
20M&L for brick work with sub class 'B' old size, burnt brick straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and directed.
21All as per srl item No 20 above but except brick.complete all as specified and directed
22M&L for 15mm thick rendering with WPC in cm 1:4 on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc and applying two coat of of cement base paint over and including a coat of priming all as directed, rubbish of the premises complete all as specified and directed.
23Dismantling of brick tiles or terracing tiles single layer on roof , mumty and removal of debrish beyond MOD land complete all as specified and directed
24Demolition of mud phuska on roof slabs, any thickness including cleaning of roof surfaces and removing the debris upto the distance exc 1.00 Km but not n.exc 1. 5 Km complete all as specified and directed.
25M&L for wire brushing and cleaning top surface of existing roof surface, and including taking down old APP membrane flashings and junction of parapets, etc. complete all as sepcified and directed.
26M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof padding/kerb, mud slopes, rounded or chamfered edge complete all as specified and directed
27M&L for 10mm thick screed bed in cement mortar 1:4 with water proofing liquid as per manufacturer instructions when concrete is a still green etc complete alll as specified and directed.(Note:- Water proofing liquid shall be measured and separately)
28M&L for applying a coat of bitumen primer confirming @0.50 ltr/ Sqm on prepared surface of plaster and applying a coat of hot blown bitumen 85/25 gde @1.2 kg/sqm and applying APP based Polymeric membrane minimum weighting 3.0kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt.not less than 150 grm/ sqm) and sealing joints by torched application complete all as specified and as directed. (Note: Work be done through approved applicator of the manufacturer only)
29Supply and fixing Heat Resistant cement based Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet wallsin the same manner. complete all as specified and as directed.
30Supply only liquid water proofing compound of approved make complete all as specified and as directed.
31S&F 1000 ltrs capacity rotational molded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, including dismantling water tank complete all as specified and directed.
32S&F 16 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings including all fitting on walls/ceiling or laying in floors complete all as specified.
33S&F 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings including all fitting on walls/ceiling or laying in floors complete all as specified.
34S&F 110mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps (as per sample) fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls and including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings viz. heads, shoes, bends, swan-necks etc, removal rubbish beyond MOD land complete all as specified and directed.
35All as per Item 34 but 75mm bore complete all as specified and directed
36S&F 110mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed.
37All as per item 36 but 75mm bore complete all as specified and directed
38M&L preparation of old decorated plastered surfaces by complete removal of existing treatment & applying two coats of cement base paint on walls complete all as specified & directed.
39M&L for preparation of old decorated plastered surfaces of walls etc by complete removal of existing treatment including washing, rubbing down and stopping of surface and applying two coats of oil emulsion distemper over and including a coat of primer on wall surfaces complete all as specified and dircted.
40M&L preparation old plastered surfaces of ceiling and applying two coats of white wash all as specified and directed.
41M&L for 15mm thick rendering of ready mix plaster of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc all as specified and directed .
42M&L for 10mm thick rendering of ready mix plaster of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down old plaster and taking out rubbish off the premises complete all as specified and directed.
43M&L for 5mm thick rendering of ready mix plaster of approved make on soffit of Rcc slab/ceiling/beams, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster and taking off the rubbish of the premises complete all as specified and directed.
44M&L preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistance primer on external surfaces of walls complete all as specified and directed.
45M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of alkali resistance primer complete all as specified and directed.
46M&L preparation of newly plastered surfaces of ceiling and applying two coats of white wash all as specified and directed.
47M&L for applying wall care putty 1mm thick on wall/ ceiling even and fair surface complete all as specified and directed.
48Dismantling of Loose concrete cover from celing surface/chajja (including staicase ceiling) are exc 1.50 sqm including derusting of steel reinforcement,(reinforcing the reinforcement by providing TMT steel bar of required dia welded to the existing reinforcement) preparing the surface by cleaning dirt etc, applying chemical admixture over reinforcement,provided chicken wire mesh (before applying first layer). Apply a rendering coat of cement plaster upto surface of existing thickness of concrete in CM 1:3 and second layer 10mm thick rendering in CM 1:3, three coats of whitewash to match with existing surface complete all as specified and directed.Note : Rate quoted shall be inclusive of all scaffolding, props and shuttering, chicken wire mesh, steel reinforcement, chemical admixture and other T&P etc.
49M&L for Preparation of existing surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed.
50Demolition of cement concrete (unreinforced) floor in ground floor and paving not exc. 15cm thickness (below or above ground level), removal of rubbish beyond MOD land complete all as specified and as directed.
51M&L 75mm thick PCC (1:3:6) type C2 (using 20mm stone aggregate) as in floors/pavings /plinth protection etc, finished even and fair with using extra cement grooves filled with bitumen mastic filling of mix (1:2) (bitumen and sand) complete all as specified and directed.
52M&L for 18 mm thick 100% Solid WPC (Wood Polymer Composite) Laminated Board of required size comprising of virgin PVC resin of K Valve 57-60 (Suspension Grade),Calcium Carbonate and natural fibers ( Wood powders/rice husk/Wheat husk) and non toxic additives, made from Extrusion process WPC foam sheet Single Extruded (Inner) with density not less than 650 kg/cbm having good screw holding capacity (Screw Withdrawal strength of 2000 N (Face) & 1100 N (Edge), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850 N/mm2 and resistance of spread of flame of Class A category with property of being Termite/Borer Free, Water/Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter complete all as per specified and directed.Note : Material test certificate and authentication should be provided by the manufacturing company.
53S&F of stainless steel handles 100 mm size for kitchen cabinet shutters complete all as per specified and directed.
54S&F of Stainless steel auto closing hinges openable at 0 degree for kitchen cabinet shutters complete all as per specified and directed.
55S & F of chrome plated stainless steel wire basket (storage / Plain basket) pull out type, size 380 x 500 mm with necessary fixing clips etc. complete all as per specified and directed.
56S & F of chrome plated telescopic channel size 450mmx20mmx1.5mm with necessary fixing clips etc. complete all as per specified and directed.
57Taking down door/window/ventilator frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) complete all as specified and directed.
58Taking down door/window/ventilator frames with shutters exc 1.50 sqm but not exc 4.00 sqm each.(without taking off shutters from frame) complete all as specified and directed.
59S&F in opening Solid PVC door frame (Factory made) of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as per specification and as per drawing on Sl page 150 of SSR (Part II) complete all as specified and directed.
60S & F Solid panel PVC door shutter (Factory made) 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded prelam PVC sheet having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail, bottom rail on either side & as gap insert for top rail & bottom rail, panelling of Prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement and provision of partially louvred frames, Supply & Fixing in the frame at site, complete all as per specifications & as per drawing on Sl page 146 of SSR (Part-II) complete all as specified and directed.
61S&F flush shutter 35mm thick solid core construction with block board core and plywood face panels,comercial type on both sides complete all as specified and directed.
62S & F 35 mm thick hardwood glazed and skelton shutters, open rebated & prepared to receive glass ,gauge etc. (with or without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified complete all as specified and directed.
63S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed.
64M&L Mild steel frame work as in door chowkhats with angle iron welded toghether ends of angle shouldered and fixed to opening, confirming to Fe-410-W (Gde-E-250) quality 'B' complete all as specified and directed.
65S&F 150mm long aluminium anodised tower bolt of extruded section complete all as specified and directed.
66S&F 100 mm long Butt hinges medium weight cold rolled miled steel, and fixed as specified.
67S&F 150 mm long extruded aluminum alloy handles, febricated typed, anodised complete all as specified and directed.
68S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
69S&F Aluminium door single leaf with powder coated aluminium frame of section 62.5x37x1.5mm thick, shutter with bottom & middle rail of section 112.50x 37x1.5mm thick and styles & top rail of section 83x37x1.5mm thick with centrally locking arrangement with lock lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5mm thick frosted glass including necessary fittings, fixtures & aluminium snap beads, complete all as specified and directed.
70S&F anodised aluminium ventilator with aluminium anodised frame of aluminium section 62.50 mm x 37 mm x 1.5mm thick and with top hung shutter having style and rails of aluminium section 47.62 mm x 44.45 mm x 1.5 mm thick and shutter wire gauzed and bottom half portion of shutter fixed type and glazed glass pane without sash bars including necessary joining cleats,glazing clips,rubber packing, anodized, aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long, handles and 100mm long SS hinges etc complete all as specified and directed.
71S&F powder coated aluminum sliding windows three track section (size 92mm x 31075mmx 2.00mm) weight not less than 1.864 Kg/m and shutter size 14.70mmx43mm with aluminium anodised frame (chowkhat) of aluminium section 104.00mmx44.45mmx1.80mm thick and two shutter having 14.80 nn thick tinteg glass and one shutter stainless steel wire of dia 0.36 mm and average width of aperture 1.40 mm complete all as specified and directed.
72S&F in repair stainless steel kitchen plate rack made out of stainless steel sheets 1mm thick overall size 900mm x 900mm x 250mm complete all as specificed and directed.
73S&F in repairs stainless steel sink of thickness of sheet not less than 0.8mm for kitchen or loboaratory with plug, washer and wastes, including bedding in cement morter to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size of bowl size 495mmX420mm bowl size 410mmX330mmX160mm complete all as specified and directed.
74Demolition of reinforced cement concrete as in Chajja, RCC parapet, Kitchen slab, Chullah hood, chimney portion and similar work concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
75M&L Formwork to soffits of suspended slabs such as kitchen slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surfaces of concerete all as specified and directed.
76M&L for reinforced cement concrete Nominal Mix using type B-1, 1:2:4 (20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like concerete all as specified and directed. (Note :- Steel reinforcement bars shall be measured and paid separately under relevant items)
77M&L for mild steel TMT bars upto 10mm dia and over cut to length,bent to shape required including cranking, biniding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
78M&L Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms over & including 15mm thick screed in cement mortar (1:4) with pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
79M&L for Cutting holes havin superficial area n. exc. 150 but n. exc 400 sqm into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
80M&L Glazed ceramic coloured joint free tiles of size 450mmx300mm, 300X600 mm and 450X600 mm 6 to 7mm thick on vertical surfaces of walls such as skirting dado etc and jointed in neat cement slurry and pointed in white cement to match laid over and including 10mm thick backing coat in CM 1:4 and including dismantling floor, hearth or wall tiling including cement mortor bedding (including backing) removing of rubbish beyond MOD land complete all as specified and as directed.
81M&L Non skid ceramic coloured joint free tiles 600mm x 600mm, 7 to 8mm thick (square/ rectangular), in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including cement screed bed 15mm thick in cement mortar (1:6) and including dismantling floor, hearth or wall tiling including cement mortor bedding (including backing)removing of rubbish beyond MOD land complete all as specified and directed.
82All as per item 81.00 here-in-before but size 400mm x 400mm, 6 to 7mm thick. complete all as specified and directed
83S&F in repair 15mm bore dia bib taps chromium plated cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule & fixed for 15mm bore GI/CPVC pipe complete all as specified and directed.
84S&F in repair 15mm bore dia Pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shank and fly-nuts screwed for iron pipes and fixed all as directed.
85S&F in repair 15mm bore dia stop valves cast copper alloys, screwed down high pressure chromium plated (Angle valve) with crutch, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
86S&F in repairs 600mm long tubular towel rails 20mm dia, D type between flanges of brass chromium plated complete all as specified and directed.
87M&L in repair for looking mirror size 600x450 selected qualaity mounted on 6mm commercial plywood and fixed with brass screw and cup washer including aluminium frame, complete all as specified and directed.
88S&F in repairs 15mm size PVC connection 450mm long with PTMT nuts complete all as specified and directed.
89S&F in repairs Vitreous China wash hand basin, white, flat back, size 550X400mm excluding excluding taps, waste, chain and plug and porcelain stopper but including brackets and PVC Connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
90S&F in repair 32mm dia CP waste coupling and 32mm dia flexible waste pipe 1.20 m long suitable for wash hand basin and sink complete all as specified and directed.
91S&F in repair 32mm dia PVC waste pipe suitable for sink, wash basin, urinal as require complete all as specified and directed.
92S&F in repairs Vitreous China squatting pan, ‘Orissa’ pattern' size 580 x 440 mm white with integral foot rests (excluding flushing cistern), including flush pipe of polyethylene of low or high density, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete trap set in concrete and including CI 'P' Trap & 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed.
93S&F in repair Vitreous China urinals, Half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) including PVC Connection 15mm size 450mm length complete all as specified and as directed.
94S&F in repairs 10 Ltrs capacity PVC low level flushing cistern complete with syphone handle lever including connecting to WC and fixing on walls with rawl plug, screws and including PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
95S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
96S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
97M&L for false ceiling with 600mmx600mmx4mm thick 'E' board classic of M/S Eternit Everest Ltd or Charminar make as approved by GE, fixed with and including galvanized iron powder coated inverted 'Tee\\" or 'L' sections (concealed GI/aluminium frame work) of 'Cicage' metallic or equivalent suspended from ceiling with provision of galvanized iron wire 45 mm dia and self tapping screws including butterfly clips, hold down clips for fixing the boards to frame complete all as pe manufacturer's instructions and all as directed including two coats of oil bound distember on one side of the board.(a) Size of Main Tee- 39x24.7x0.8mm (b) Size of Cross Tee- 29x24.7x0.8mm(c) Size of wall angle - 22.2x22.2x0.65mm (d) Butter fly clip (e) Hold down clip (f) Size of grid 1.22mx0.61m
98S&F curtain rods of stainless steel 25mm dia with and including SS decorative finials and SS brackets suitable for SS curtain rod fixed on wall etc complete all as specified & directed. Note : -(a) Only length of SS curtain rod shall be measured and paid.(b) SS decorative finisals and brackets shall be provided for each curtain rod and rate shall be incuded with SS curtain rod.
99M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed.
100M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including demolition of old paver block or stone slab laid dry complete all as specified and as directed.
101M&L for 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
102M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 20mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment over and including demolition of old chequered tiles all as specified and as directed.
103Dismantling of asbestos cement (corrugated semi corrugated sheet & ridge in roof covering complete all as specified and directed.
104M & L for pre-painted galvalume aluminium zinc coating (150 GSM) GI based corrugated steel sheet o.50 mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws as specified.
105M & L for pre-painted galvalume aluminium zinc coating (150 GSM) GI based plain steel sheet o.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
106Dismantling timber scantlings unframed work 40 sq. cm and over in section, in any position complete all as specified and directed.
107M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
108Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and making good disturbed surfaces of walls, floors, etc
109Taking down old MCCB , TPN DBs , SPN DBs, sp mcb & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
110Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
111Disconnecting elect connection and taking down of ceiling fan/ Exhaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
112M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
113(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
114(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
115(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
116M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified
117Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls all as specified and as directed.
118M&L switch Modular type 6 Amp SP one way ISI marked complete all as specified
119M&L switch Modular type type 16 Amp SP one way, ISI marked complete all as specified
120M&LModular type socket outlet 5 pin 6 Amp flush type, ISI marked complete all as specified
121M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified
122M&L ceiling rose 3 phase PVC polycorbonate,isolated body, complete all as specified
123S & F Modular electronic fan regulator step type,1 module ,360 degree rotation complete all as specified and directed by engr-in charge.
124M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on completion all as specified and directed.
125Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one VTPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
126M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting.
127Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
128M&L MCB SPN 40 Amp \\"B\\" curve, 10 kA complete all as specified.
129M&L MCB SP 6 to 32 Amp \\"B\\" curve ,10 kA. complete all as specified.
130Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 105 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete...
131Supply and fix in replacement 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary - is >100lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%,THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
132S & F in replacement pressure die cast aluminium housing LED street light luminaires with IP66 deg. of protection suitable for 60 watt LED fitting duly fixed on 40 mm dia GI mast including 50X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : The Contractor quoated the rates incl all accessories like suitable GI pipe mast, 50x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire.
133Supply and fixing new BLDC fan against old ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator.
134Provn of modular box type metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed.
135S &F Wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site.complete all as specified and directed
136Provn of water heater storage type Geyser vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet water connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073218
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32.71 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No P-06, P-25 At Station Wksp Eme, Addn/Altn Of Jali Cover And Hightening Of Sintex At Mt Line Area For Jcos/Or Md Accn And Wksp Area Of Station Wksp Eme In The Area Of Age B/R (Project) Salaria Under Ge (West) Delhi Cantt-10
Basic Detail
Tender No GE/DW/TOKEN/106 OF 26-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 15 Oct 2026
Submission Date 05 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 32.71 Lakhs
Tender Fee 500
EMD 65420
Exemption Available
Document List
6dc4bb34-bfdc-4a4e-8252-794cfb99808b.html
BOQ_890703.xls
PS106.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

6dc4bb34-bfdc-4a4e-8252-794cfb99808b.html

xls

BOQ_890703.xls

pdf

PS106.pdf

pdf

Tendernotice_1.pdf

Disclaimer