Tender For Demolition Of T-6 (Guard House, Armoury And Saa Store) And Construction Of Guard House And Station Armoury At Air Force Station Jaipur
Tender Value
1.56 Crore
Estimated cost
Bid Submission
17 Nov 2026
27 days left
EMD
2.31 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Demolition Of T-6 (Guard House, Armoury And Saa Store) And Construction Of Guard House And Station Armoury At Air Force Station Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 2.00 to 14.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I. |
| 3 | Lump sum price worked out for Demolition/ Excavation / Earthwork & Site Clearance as listed in Sch `A’ Part II |
| 4 | Lump sum price worked out for Internal Electric Supply as listed in Sch `A’ Part III |
| 5 | Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part IV |
| 6 | Lump sum price worked out for Fire Fighting System as listed in Sch `A’ Part V |
| 7 | Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part VI |
| 8 | Lump sum price worked out for Air Conditioning as listed in Sch `A’ Part VII |
| 9 | Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part VIII |
| 10 | Lump sum price worked out for External Water Supply as listed in Sch `A’ Part IX |
| 11 | Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part X |
| 12 | Lump sum price worked out for Area Drainage as listed in Sch `A’ Part XI |
| 13 | Lump sum price worked out for Fencing & Gate as listed in Sch `A’ Part XII |
| 14 | Lump sum price worked out for Road path/Culvert/Hardstanding as listed in Sch `A’ Part XIII |
| 15 | Lump sum price worked out for Flame Proof as listed in Sch `A’ Part XIV |
| 16 | SCHEDULE 'A' PART - XV Misc Items is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 17 | Taking down carefully copper/ aluminium Sub main wiring of any size from surface/ concealed /existing conduit of any height and removing materials at site complete all as specified and directed. |
| 18 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and carrying to MES store yard complete all as specified and directed. |
| 19 | Taking out/down u/s LT UG cable of size 3.5 core x 50 sqmm size from trenches/ pipe/ ducts/ pole complete all as specified and directed. |
| 20 | S & F for Flame proof brass unions suitable for 20 mm ERW conduit duly certified by CMRI complete all as specified.. |
| 21 | S & F for Flame proof brass bends suitable for 20 mm ERW conduit duly certified by CMRI complete all as specified. |
| 22 | S & F for Flame proof closing plugs suitable for ERW 20 mm dia conduit duly certified by CMRI complete all as specified. |
| 23 | S&F flame proof /Weatherproof 4 way junction box with 4 Nos terminal for looping in and looping out connections, duly certified by CMRI Dhanbad complete all as directed |
| 24 | Supply and fix flame proof/weather proof exhaust fan of 300 mm (12\\") sweep with 0.25HP motor, 230 volts single phase, 50 Hz, with provn pf louvers and bolts nuts and washers including flame proof flexible metallic conduit with necesary electrical connections complete all as specified and as directed. |
| 25 | S&F flame proof Sheet steel metal enclosure with distribution box ,SPN 4 Way 240 Volts with MCB 2 Pole, 25 Amps-1 No, Outgoing MCB SPN, 240 Volts 5-32 Amps- 01 Nos complete with internal Bus Bar & wiring upto terminal, duly certified by CMRI Dhanbad complete all as directed |
| 26 | S&F Addressable panel single loop extandable to 3 loop microprocessor controlled fire control panel suitable for wall/floor mounting fabricated from 18 SWG CRCA sheet as per specification complete with power supply and battery charger , including interconnections of all zones and supply etc. |
| 27 | M&L for control console complete all as specified and directed. |
| 28 | M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable of size 2 core x 1.5 Sq mm, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 Volts, drawn through and including concealed MS ERW conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the engineer-in-charge. Please Enable Macros to View BoQ information |
| 29 | M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable of size 2 core x 1.5 Sq mm, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 Volts, drawn through and including concealed MS ERW conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender