Tender For Repair/Maint To Feeder Pillar Box, Busbar, Lt Panel, Flood Lights And Allied Works At Mffr Under Age (I) Mffr
Tender Value
30 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint To Feeder Pillar Box, Busbar, Lt Panel, Flood Lights And Allied Works At Mffr Under Age (I) Mffr
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Excavating in trenches, not exc 1.5 metre wide and exc 1.5 metre but not exc 3.0 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 4 | Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. |
| 5 | M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. |
| 6 | M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of formwork (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. |
| 7 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed.Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment. |
| 8 | Supply and fixing for Pre-stressed concrete pole 9 metre long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, including taking out old unserviceable pole complete all as specified & as directedNote :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid for separately. |
| 9 | S&F Stay assembly complete with 20mm dia, 1800mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanized clamps made out of 40mmx6mm flat iron including MS galvanized nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanized stay plate, stay bow and stay clamp, with & including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, all as shown in electrical plate No 1 of MES Schedule Part-I, including taking out old unserviceable stay assembly, complete all as specified and as directed.Note : Excavation & earthwork, PCC, insulator and stay wire shall be measured & paid for separately under respective items of this Schedule. |
| 10 | S&F Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90mm x 140 mm and clearance hole 25.5 mm, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed. |
| 11 | Supply and Fixing in replacement GI wire 4mm and stranded 7/1.6mm dia fixing for cradle in road crossing and stay wire, complete all as specified and as directed. |
| 12 | Supply and erecting of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) with 2 coats of aluminium anti corrosive paint of first quality and painting to pole upto 1.5 mtr height from top of PCC coping with synthetic enamel paint 2 coats in black and white alternative strip including numbering in 8 cm height of number with white paint, both paints (aluminium/synthetic as approved) including numbering of poles complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply and fixing in replacement SITC CPRI approved outdoor cubical type LT feeder pillar box, with bus bar chamber having 4 wire 415 Volts, 50Hz, AC supply system fabricated from 3mm thick outer shell of stainless steel (SS 316) with MS angle 50mm x 50mm x 6mm frame totally enclosed front and back openable, single door system lockable by key from both sides with flush pattern fancy locks with louvers & air vent gasket for natural air flow, dust, weather & vermin proof, bottom of the outer shell contains a detachable plate having provision for entry of cables with gland and 50mm space between outer shell and inner shell all round and same shall be easily taken out on requirement and dangar notice plate also be fixed on outer shell and the INNER SHELL shall be made of 2mm thick stainless steel (SS 316) compartmentalized for each control gear, front openable single door system lockable having TPN copper busbars of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of mild steel section not less than 100mm x 50mm x 5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with minimum 2.5sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two haif including tamper proof digital energy meter to measure voltage, current, PF, KWH, KVAH, KVARH and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation with following detailed specifications & control: - |
| 14 | (i) TPN copper bus bars insulated with colour coded heat shrinkable sleeves and shall mounted on suitable size F class insulators made of nonhygroscopic, noncombustible, track resistant, high strength SMC material at suitable interval throughout the length, computer cut self adhesive vinyl dangar notice plate having conventional symbol of bone & skull be provided on bus bar chamber. (ii) All control wire shall be not less than 1.5sqmm multistranded copper conductors and shall properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coating.(iii) Detachable predrilled gland plate of thickness 3.15mm zinc metal coated.(iv) Indicating lamp with 11 Watt LED shall be fited on top and inner shell.(v) Degree of protection for inner shell shall be IP-42.(vi) INCOMING: MCCB, 4 pole, 63 Amps, Ics 25 KA, 415 Volts, 50 Hz with thaermal magnetic fixed type- 01 No. (vi) OUTGOING: MCB two pole, 40 Amp - 04 Nos, Provision of 5 Nos outgoing through busbars. |
| 15 | S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on 1100 Volt LT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed.Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code. |
| 16 | Material and labour for disconnecting the cable of size 10 to 35 Sqmm 2/4/3.5 core from feeder pillar box/DBs/Bus bar chamber/OH lines etc for replacing the thimbles or cutting the cable by taking out cable from loop/trenche/pole and reconnecting the cable in same position complete all as reqd at site and as directed by Engineer in Charge. Note: One end of cable to be measured as one Job. |
| 17 | Material and labour for disconnecting the cable of size 35 to 185 Sqmm 4/3.5 core from feeder pillar box/DBs/Bus bar chamber/OH lines etc for replacing the thimbles or cutting the cable by taking out cable from loop/trenche/pole and reconnecting the cable in same position complete all as reqd at site and as directed by Engineer in Charge. Note: One end of cable to be measured as one Job. |
| 18 | Material and labour for repairing of broken ACSR vessal/ squarel /ferrot/ mink conductor after proper shutdown of electric supply and jumpring / cut points changing the damaged/ burned conductor, cable ends, changeover MCCBs condutor broken due to wind/storm and binding with the aluminium wire etc and changing the damaged pin/disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and as directed by engineer-in-charge.Note:- cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted item.(ii) Cost of items that is pin insulator,disc insulator etc. shall be measured and paid seprately under respective items. (iii) Contrator take complaints from complaints cell (JE E/M) and rectify the same day and duly signed by the users and deposited the same. one down breakdown/coplaint by attended shall be the Each Job. |
| 19 | S&F Pin type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed. |
| 20 | S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed. |
| 21 | Supply and fixing in replacement of extended terminals of MCCBs upto 160 Amp complete all as specified and dircected. |
| 22 | Supply and fixing in replacement of extended terminals of MCCBs upto 200 Amp complete all as specified and dircected. |
| 23 | Supply and fixing in replacement of extended terminals of MCCBs upto 400 Amp complete all as specified and dircected. |
| 24 | S&F in replacement of MCCB 4 Pole 63 Amps, adjustable thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 25 | S&F in replacement of MCCB 4 Pole 100 Amps, adjustable thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 26 | S&F in replacement of MCCB 4 Pole 125 Amps, adjustable thermal magnetic having, breaking capacity 25 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 27 | S&F in replacement of MCCB 4 Pole 160 Amps, adjustable thermal magnetic having, breaking capacity 36 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 28 | S&F in replacement of MCCB 4 Pole 200 Amps, adjustable thermal magnetic having, breaking capacity 36 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 29 | S&F in replacement of MCCB 4 Pole 400 Amps, adjustable thermal magnetic having, breaking capacity 36 KA, 415 Volt in the existing LT control panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as required at system complete all as specified and directed. |
| 30 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. |
| 31 | M&L for Earthing to equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified and as directed.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. Please Enable Macros to View BoQ information |
| 32 | M&L for Earthing to equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified and as directed.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender