Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58073179

Tender For Repair And Maintenance Of Internal With Connected Items Incl Solar Water Heater And Geyser At Otm Accn 3 Eme Centre, Engr Regt, 5221 Asc Mt, 4021 Fd Hospital, 194 Wksp, Hrdc, Mdc And 21 Cgsr At Bairagarh Under Ge Bhopal.

Issued by Statutory Bodies & Commissions/Committees · Bhopal, Madhya Pradesh
Tender Value
37 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
20 days left
EMD
74000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Internal With Connected Items Incl Solar Water Heater And Geyser At Otm Accn 3 Eme Centre, Engr Regt, 5221 Asc Mt, 4021 Fd Hospital, 194 Wksp, Hrdc, Mdc And 21 Cgsr At Bairagarh Under Ge Bhopal.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF INTERNAL WITH CONNECTED ITEMS INCL SOLAR WATER HEATER AND GEYSER AT OTM ACCN 3 EME CENTRE, ENGR REGT, 5221 ASC MT, 4021 FD HOSPITAL, 194 WKSP, HRDC, MDC AND 21 CGSR AT BAIRAGARH UNDER GE BHOPAL.
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline
2Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc.complete all as specified and directed.
3M&L for point wiring for one light / fan / bell point with one run of 1.50 sqmm (nominal area) FRLS PVC insulated, multi-stranded copper conductor cable, 1100 volts grade, controlled by one-way switch, drawn in and including non metallic rigid PVC casing capping, medium grade, ISI marked, not less than 25mm base with all fitting and fixing accessories including additional run of FRLS PVC insulated multistranded 1.5 sqmm copper conductor cable as earth continuity wire, sunken sheet steel terminal box for mounting of fittings like switches, sockets, fan regulators, etc. with 2.8 mm thick laminated hylum sheet cover complete all as specified and directed.
4All as per item No 2.00 here-in-before but for one light point controlled by two way switches complete all as specified and directed .
5All as per item No 2.00 here-in-before but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
6All as per item No 2.00 here-in-before one 3 pin 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
7All as per item No 2.00 here-in-before but wiring with 2.5 Sq mm FRLS PVC insulated multistranded copper cable for 5/15 amp socket outlet on independent board and provision of additional FRLS PVC insulated multi-stranded 2.5 sq mm copper cable as earth wire for earth continuity, complete all as specified and directed.
8All as per item No 2.00 above, but wiring with one run of FRLS PVC insulated multistranded 4 Sq mm copper cable for 15 amp socket outlet on independent board and provision of additional FRLS PVC insulated multi-stranded 4 sq mm copper cable as earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
9M&L for Point wiring using colour coding as per IS, for one light point/bell point/fan point with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, PVC insulated FRLS cable 1100 volts grade, and including medium grade, PVC concealed conduit and conduit accessories in wall/roof/floor etc, ISI marked, with sheel metal MS flushed box, white cover plate with frame for fixing modular switches, sockets and fan regulators etc, including additional PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area, FRLS cable as earth continuity conductor complete all as specified and directed at site.
10All as per item No 8.00 here-in-before but for one light point controlled by two way switches complete all as specified and directed .
11All as per item No 8.00 here-in-before but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
12All as per item No 8.00 here-in-before one 3 pin socket outlet 5 Amps on same board all as specified and directed.
13All as per item No 8.00 here-in-before but 3 pin socket outlet 15 amps on independent board elect wiring 2.5 sq mm complete all as specified and directed.
14All as per item No 8.00 here-in-before but wiring with one run of PVC insulated FRLS 1100 volts grade multistranded copper conductor cable of 4 Sq mm for 15 amp socket for 3 pin socket outlet on independent board and provision of additional 4 Sqmm, FRLS insulated multi-stranded copper cable as earth wire for earth continuity, complete all as specified and directed.
15S&F in repairs switch piano, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, complete all as specified and as directed.
16S&F switch piano, one way, single pole, 16 Amp, 240 volt, 50Hz, complete all as specified and as directed.
17S&F in repairs Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp, 240 volt AC, ISI Mark complete all as specified and as directed.
18S&F in repairs socket outlet 2 in 1, 3 pin 6/16 Amp, 240 volt AC complete all as specified and as directed.
19S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, complete all as specified and as directed.
20S&F in repair LED tube light fitting, surface mounted lumanaires, 1 x 20 W, 230V, AC , square profile, with polycarbonate housing, complete with all accessories including connecting up with PVC insulated multistranded copper cable of 1.5sqmm 3 core, complete all as specified and directed.
21S&F in repair LED tube light fitting, surface mounted lumanaires, 1 x 10 W, 230V, AC, mirror type, square profile, with polycarbonate housing, complete with all accessories including connecting up with PVC insulated multistranded copper cable of 1.5sqmm 3 core, complete all as specified and directed.
22S&F in repairs ceiling fan regulator electronic step type 230 V, AC 50 Hz single pole, 100 watts complete all as specified and as directed.
23S&F in repairs modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
24Supply and fixing in repairs modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 230 volts, complete all as specified and directed.
25Supply and fixing in repairs modular fan regulator, 5 step, 230 volts AC, 2 module, 100 W complete all as specified and directed.
26S & F in repairs modular switch, one way, 6 Amp, one module, 230 volts AC, complete all as specified and directed.
27S&F in repairs modular switch, one way, 16 Amp, one module, 230 Volts AC, complete all as specified and directed.
28Taking down old unserviceable sub main wiring including service connections, of any size and any description including conduit pipe all as specified and directed.
29M&L for sub main wiring with colour coding as per IS, with two single core PVC insulated FRLS cable 1100V with multistranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. with 20mm external diameter and additional PVC insulated FRLS multistranded copper conductor cable of 4 sqmm nominal cross section area as earth wire complete all as specified and directed.Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
30M&L for sub main wiring with colour coding as per IS, with two single core PVC insulated FRLS cable 1100V with multistranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. with 20mm external diameter and additional PVC insulated FRLS multistranded copper conductor cable of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed.Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
31Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
32S&F in repairs sheet metal enclosure for MCB, DB, TPN ( triple pole and neutral), 415 Volts, 200 Amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, powder coated, IP 43, surface mounted/flushed in wall complete all as specified and as directed.
33Supply and fixing in repairs factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) double door, and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and flushed to wall, suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.
34S&F in repairs sheet metal enclosure for SPN DB ( single pole and neutral) double door type surface mounted concealed in wall 8 ways, 240 Volts, IP 43, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed.
35S&F in repairs sheet metal enclosure for SPN DB ( single pole and neutral) double door type, surface mounted/flushed in wall 12 ways, 240 Volts, IP 43, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed.
36Taking down of old unserviceable MCB SP/SPN /TPN /MCCB/ sheet metal earth plug socket with MCB of any capacity all as specified and directed.
37S&F in repairs MCCB 63 Amp, 4 Pole, breaking capacity 16 KA with complete electrical connections by appropriate size of copper/aluminium lugs, complete all as specified and directed.
38S&F in repairs MCCB 100 Amp, 4 Pole, breaking capacity 16 KA with complete electrical connections by appropriate size of copper/aluminium lugs, complete all as specified and directed.
39S&F in repairs MCB SP, 230 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size copper lugs complete all as specified and directed.
40S&F in repairs MCB SP suitable for 230 volts, AC, B curve, 40 to 63 Amps, with rupturing capacity not less than 10KA complete all as specified and directed.
41S&F in repairs MCB SPN suitable for 230 volts, B Curve, AC supply 32 Amps, with rupturing capacity not less than 10KA, complete all as specified and directed.
42S & F in repairs MCB SPN suitable for 230 volts, B curve, AC supply 40 to 63 Amps, with rupturing capacity not less than 10KA complete all as specified and directed.
43S & F in repairs MCB TPN suitable for 415 volts, AC, C curve, 40 to 100 Amps, with rupturing capacity not less than 10KA complete all as specified and directed.
44S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1 no. of single pole MCB 20 Amps 230 volts complete all as specified and directed
45S&F in replacement PVC insulated, PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 230 V including taking down old unserviceable cable ,complete all as specified and directed.
46Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 230 V AC recessed type with glare free light complete with driver, suitable for roof ceiling including connecting up with three core PVC insulated flexible copper conductor cable of 1.5 sqmm nominal size, complete complete all as specified and directed
47Supply and fix in repairs post top lantern fitting 25 Watt, IP-65, with complete accessories, including taking down old unserviceable Post top lantern fitting and connecting of new fitting with 3 core PVC insulated multistranded copper cable of 1.5 sqmm all as specified and directed by Engineer in charge.
48S&F in repairs building security light fitting 30 Watt made up of pressure die cast alluminium housing with high efficient LED as lighting source with IP-66 Protection and impact resistance of IK07 including 32/44 mm dia galvanized iron pipe \\"light grade\\" brackets 1 mtr length bent to required shape including clamps, nuts/bolts/washers etc including connecting with 3 core PVC insulated multistranded copper cable of size 1.5 sqmm complete, including taking down of old unserviceable fitting all as specified and directed.
49S&F in replacement flexible wire three core copper conductor of size 23/0.0076 for light fittings etc complete, including taking down old/unserviceable wire all as specified and directed.
50M&L for earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth wire of 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 SSR including earth pit in any soil char coal common salt ,15 mm all around earth plate PCC (1:3:6) type with 40 x40x6 mm angle iron frame and RCC cover (1:2:4) type B1 of thickness 50 mm, including 6mm TMT bar 50 mm centre to centre spacing with 20 mm stone aggregate, water pipe made of light grade GI pipe 20 mm bore, MS funnel, wire mesh, handle made with MS bar of 10 mm dia and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel upto 7.5 m all as specified and directed.
51Taking down of Solar water heating system any make of 200 ltrs per day capacity from its position after disconnecting water connections, and re - fixing /reassembling in position after repair and testing, complete all as specified and as directed.Note:- (a) Rate quoted by the contractor deemed to have been included making good of missing Nuts, Bolts and washers, unions, sockets, flanges, screws etc to make it fully functional,(b) Descalling/desludging, cleaning and washing of solar panels,hot water pipes,copper tubes,hot and cold water Tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required.(c) Painting of staging, solar panel frames,hot water tank frame using one coat of synthetic enamel paint including necessary preparation of surfaces complete.(d) Any other materials/Parts need to be replaced(to be measured and paid as supplied only).
52All as per item No.50.00 here-in-above but 100 Litre per day capacity.
53S&F in replacement of Stainless steel, Water heater tank, suitable for 100 LPD to match with existng SS tank specifications, with all arrangements, complete all as specified and directedNote:- (i) Thickess of new tank to be matched with existing tank. (ii) The work should be executed at the top of 20m height building.
54S&F in replacement of Stainless steel, Water heater tank suitable for 200 LPD , to match with existng SS tank specifications, with all arrangements, complete all as specified and directedNote:- (i) Thickess of new tank to be matched with existing tank. (ii) The work should be executed at the top of 20m height building.
55S & F Solar energy collector panel made of Aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 litres per day as per existing make complete all as specified & directed.
56S & F Solar energy collector panel gasket made out of Superior quality Rubber to make system air tight,dust and water proof complete of capacity 200 litres per day as per existing make complete all as specified & directed.
57S & F compressed Glass wool(insulation materials) 48mm thick between Solar energy collector panel copper tubes frame and Aluminium body panel including securing it on panel by means of necessary adhessive complete all as specified & directed.
58S & F Solar energy collector panel manifold 1.40 mtr long, made out of 20mm dia copper tube having 1 No MS flange,74mm dia welded at each end duly drilled for Nuts,Bolts and washers as per existing make including welding of solar collector tubes with manifold complete all as specified & directed.
59S&F in repair of rotational moulded, 3 layer HDPE water storage tank of 500 ltrs capacity (Cylindrical vertical with closed top), ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball including fixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
60S&F in repair of rotational moulded, 3 layer HDPE water storage tank of 1000 ltrs capacity (Cylindrical vertical with closed top), ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball including fixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
61Taking down of Geyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the ineer tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed by Engr-in-charge.
62Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new geyser element of 1.5 KW, 230 volts to match with the existing system complete all as specified & directed.
63Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new geyser element of 2.0 KW, 230 volts to match with the existing system complete all as specified & directed.
64Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30 C to 80 C suitable for 230 volts AC electric supply. complete all as specified & directed.
65Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new indication lamp (set of two) complete all as specified & directed.
66Disconnecting & taking up or down existing unserviceable PVC connections of any description from geyser installed at site and supplying and fixing new braided connection for geyser inlet and outlet of length 450mm including rubber washers complete all as specified & directed.
67M&L for painting of the Geyser 25/50 Ltrs capacity and in any position, by applying two coats of paint (DUCO) white by spray machine including preparation of existing decorated surfaces all as specified and directed.
68Supply & Fix in replacement of Geyser vent assembly suitable for 25 ltr capacity ISI marked including dismantling of old unserviceable geyser vent assembly complete all as specified & directed.
69Supply & replacement of inner tank made of steel suitable for 25 Ltr geyser including dismantling of old unserviceable inner tank complete all as specified & directed.
70Supply & replacement outer body made of steel suitable for 25 Ltr Geyser including dismantling of old unserviceable body complete all as specified & directed.
71Supply & replacement bottom cover suitable for 25 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
72Supply & replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
73S&F in repairs of 3 pin plug top AC-230 V, 15 Amp, complete including taking down old pin top all as specified and directed.
74M&L for Sub main wiring with 4 runs (3P+N) three phase of single core PVC insulated cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in and including non metallic medium grade rigid PVC conduit of 25 mm dia, ISI marked including one additional run of PVC insulated, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable including cutting of wall and making good of disturbed surface complete all as specified and directed.Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Three runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
75Supply, laying, connecting and testing multistranded copper conductor cable, PVC insulated, FRLSH, PVC sheathed 3 core round flexible cable of 10 sq mm for working upto voltage upto and including 1100 volts complete all as specified and directed.
76Supply, installation, testing and commissioning of wall mounted indoor type LT distribution panel, fabricated from 2 mm thick CRCA sheet steel, dust and vermin proof, suitable for 415 V,3-phase, 4-wire, 50 Hz supply, complete with hinged and lockable front door, powder coated finish, cable entry arrangements, gland plates, internal wiring, comprising of the following: (i) 1 no. 200 A, 4-pole MCCB as incoming device, suitable for 415 V AC, complete with thermal magnetic over current and short circuit protection. (ii) 3 Phase + Neutral Aluminium busbars rated 300A, electrolytic grade high conductivity copper, adequately supported on suitable insulated supports and fully shrouded/protected against accidental contact. (iii) 14 Nos. 40A, 4-pole TPN MCBs \\"B\\" curve as outgoing, suitable for 415V AC, of approved make, complete with necessary busbar connections and outgoing terminals. (iv) 1 No. of digital voltmeter and ammeter suitable for 3 phase, 4 wire system, complete with suitable selector arrangement, and necessary CTs, fuses and wiring for measurement of phase to phase/phase to neutral voltage and current of all three phases. (v) 3 Nos. phase indicating lamps, R-Y-B, LED type, complete with suitable fuses and internal wiring, mounted on the front door of the panel (vi) 1 No of voltmeter selector switch and 1 no. of ammeter selector switch, suitable for the above metering arrangement. Panel shall also be complete with Aluminium earth bar of length equal to width of panel, control fuses/MCBs, terminal blocks, internal interconnections, cable termination arrangements, gland plates, phase identification, circuit identification labels, danger notice plate, and mounting on wall with MS nuts and bolts all as specified and directed.
77Supply, installation, testing and commissioning of wall mounted indoor type LT distribution panel, fabricated from 2 mm thick CRCA sheet steel, dust and vermin proof, suitable for 415 V,3-phase, 4-wire, 50 Hz supply, complete with hinged and lockable front door, powder coated finish, cable entry arrangements, gland plates, internal wiring and all necessary hardware, comprising of the following: (i) 1 no. 125 A, 4-pole MCCB as incoming device, suitable for 415 V AC, complete with thermal magnetic over current and short circuit protection. (ii) 3 Phase + Neutral Aluminium busbars rated 200A, electrolytic grade high conductivity copper, adequately supported on suitable insulated supports and fully shrouded/protected against accidental contact. (iii) 3 Nos. 40A, TP MCBs, \\"C\\" curve, 4 Nos of 20A, TP MCBs \\"C\\" curve as outgoing suitable for 415V AC, of approved make, complete with necessary busbar connections and outgoing terminals. (iv) 1 No. of digital voltmeter and ammeter suitable for 3 phase, 4 wire system, complete with suitable selector arrangement, and necessary CTs, fuses and wiring for measurement of phase to phase/phase to neutral voltage and current of all three phases. (v) 3 Nos. phase indicating lamps, R-Y-B, LED type, complete with suitable fuses and internal wiring, mounted on the front door of the panel (vi) 1 No of voltmeter selector switch and 1 no. of ammeter selector switch, suitable for the above metering arrangement. Panel shall also be complete with Aluminium earth bar of length equal to width of panel, control fuses/MCBs, terminal blocks, internal interconnections, cable termination arrangements, gland plates, phase identification, circuit identification labels, danger notice plate, and mounting on wall with MS nuts and bolts all as specified and directed.
78Deduct Schedule of credit (calculation will be done off line) Rs. 72858.00 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58073179
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 37 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Internal With Connected Items Incl Solar Water Heater And Geyser At Otm Accn 3 Eme Centre, Engr Regt, 5221 Asc Mt, 4021 Fd Hospital, 194 Wksp, Hrdc, Mdc And 21 Cgsr At Bairagarh Under Ge Bhopal.
Basic Detail
Tender No 8722/E8
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 15 Oct 2026
Submission Date 05 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 37 Lakhs
Tender Fee 500
EMD 74000
Exemption Available
Document List
033d1a5f-da3e-4dc5-86b8-0730df431e40.html
BOQ_890706.xls
credit8722.pdf
Tendernotice_1.pdf
TENDER_DOCU_8722.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

033d1a5f-da3e-4dc5-86b8-0730df431e40.html

xls

BOQ_890706.xls

pdf

credit8722.pdf

pdf

Tendernotice_1.pdf

pdf

TENDER_DOCU_8722.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender